| 1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(Make - KEI/RR/havells/Polycab) |
| 2 | 3 X 1.5 sq mm |
| 3 | 4 x 1.5 sq mm |
| 4 | 5 X 1.5 sq mm |
| 5 | 7 X 1.5 sq mm |
| 6 | 3 X 4 sq mm |
| 7 | Supplying and drawing following sizes of 1.1 Kv FRLS PVC insulated and PVC sheathed copper conductor, single/multi core unarmouredround cable in the existing GI bracket on pole and making joint connections from overhead line/Junction Box to light fittingas required with appropriate size thimbles. of make Polycab / Finolex / Havells/KEI. |
| 8 | 3 X 1.5 sq mm |
| 9 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. and dismantling old panel as required. (But without MCB/RCCB/ Isolator) 4 way (4 + 12 ), Double Door(Make - L&T/ABB/Legrand) |
| 10 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator), 8 way , Double Door(Make - L&T/ABB/Legrand) |
| 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make - L&T/ABB/Legrand) |
| 12 | Single Pole |
| 13 | Single Pole and Neutral |
| 14 | Triple Pole and Neutral |
| 15 | Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.(Make - Anchor/Cona). |
| 16 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.180 mm X 100 mm X 60 mm deep |
| 17 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 A switch.(Make - Anchor/Cona). |
| 18 | Supply of XLPE/ PVC insulated PVC sheathed LT power cable of 1100 V. grade confrming to IS : 7098 (Part-1) 1988 with upto date amendment of the following sizes.Make - Havells/ skytone/ Polycab/Grandlay. |
| 19 | 2 x 6 sq.mm- Aluminium Armoured |
| 20 | 4*16 sq mm - Aluminium Armoured |
| 21 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface/iron channel of platforms channel as required.Upto 35 sq. mm (clamped with metal saddle clamps) |
| 22 | Provision forlaying DWC pipe of suitable size through manual moling technique under Road and RCC crossings. |
| 23 | Supplying and laying 63 mm dia HDPE DWC pipe ISI marked along with all accessories confirming to IS 14930 part II , complete with fitting and cutting , jointing etc in the existing trench complete as required |
| 24 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq mm |
| 25 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 meter length along the pole for protection of under ground cable as required. |
| 26 | S/I/T/C ofLED Lights of following wattageon existing brackets of suitable size on pole/wallincluding dismounting old fitting. Crompton/Havells/Philips make with Specifications given in Tender Documents. (Manufacturer Warranty mandatory) |
| 27 | 45 W - Street Light |
| 28 | 30 W - Street Light |
| 29 | 100 W - Flood Light |
| 30 | 50 W - Flood Light |
| 31 | SITC of 20 W retro T-8 LED tube lamp with AL body with box type industrial batten made of CRCA steel housinglumens >=1950, pf >0.9, CRI>75,Operating voltage range 140 V -270 V with internal driveras required of Havells/Crompton/Philips make.(Manufacturer Warranty mandatory) |
| 32 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. .(Make - Anchor/Cona/Parcos). |
| 33 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required |
| 34 | Supplying and fixing of atleast 32 mm dia(min.) X 2.00 metres(dia as per light fitting) long G.I. pipe (medium class) bracket for mounting of LED street light fitting including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. and dismounting smaller size Pipe as required. |
| 35 | Supplying and fixing MS/SMC 1 phase Junction Box (with hinged door)of Sintex/Hensel or equivalent make on existing Pole/wall with provision for mounting 10 A SP MCB (Havells/L&T/Legrand) with Neutral Link and earth bolt , 415V AC, 50 Hzconfirming to (Conforms to IS/IEC:60947-1 & 3) with suitableglands, thimbles , nuts and boltsincluding making connections and dismantling old boxes as required (240 * 130* 110 mm dimension) |
| 36 | Supply and fixing of flexible GI-PVC coated conduitof 16 mm size as required |
| 37 | S/I/T&C street light control panel in powder coated CRCAsheet, outdoor type, three phase, 415 Volts consisted of suitable rating contactor, TPN MCB 40 Amp, 24 Hrs Digital/Astronomical time switch for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF,Auto) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status suitable for 3 output (1 output per phase) with cable glandsincluding making all the required cable connections and dismantling old u/s switch units. Make - Havells (Product ID -IHXTS0306A)/Fabricated(panel box only) with 14 SWG CRCA sheet with L&T/ABB/Legrand switchgears as mentioned. |
| 38 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 39 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |