Selection Of System Integrator For Capacity Enhancement Of West Bengal State Data Centre ( Wb - Sdc ) And Setting Up Its Dr Site At Remote Location.- 1 Hpe Storage Dc ( Primera 650 ) - 450Tb Upgrade To 650Tb ( +100Tb Ssd + 100Tb Sas ) 2 Netap, As per NIT-West Bengal

Webel Technology Limited-WTL has published Selection Of System Integrator For Capacity Enhancement Of West Bengal State Data Centre ( Wb - Sdc ) And Setting Up Its Dr Site At Remote Location.- 1 Hpe Storage Dc ( Primera 650 ) - 450Tb Upgrade To 650Tb ( +100Tb Ssd + 100Tb Sas ) 2 Netap. Submission Date for this Tender is 09-03-2022. Wrenches and Drivers Tenders in As per NIT West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

30171341
Corrigendum : Selection Of System Integrator For Capacity Enhancement Of West Bengal State Data Centre ( Wb - Sdc ) And Setting Up Its Dr Site At Remote Location.- 1 Hpe Storage Dc ( Primera 650 ) - 450Tb Upgrade To 650Tb ( +100Tb Ssd + 100Tb Sas ) 2 Netap
Open Tender
Indian
West Bengal
As per NIT
09-03-2022

Tender Details

Selection Of System Integrator For Capacity Enhancement Of West Bengal State Data Centre ( Wb - Sdc ) And Setting Up Its Dr Site At Remote Location.- 1 Hpe Storage Dc ( Primera 650 ) - 450Tb Upgrade To 650Tb ( +100Tb Ssd + 100Tb Sas ) 2 Netapp Storage Dc ( Aff-A700 ) - 170Tb Upgrade To 430Tb ( +260Tb Ssd ) 3 Blade Server With 2 X Intel 6238R 2.2Ghz / 165W 28C / 38.5Mb, 1536Gb Ddr4 2933Mhz Mem, 2X960gb 12G Sas 10K Rpm Sff Hdd, 12G Sas Raid Controller With Drive Bays 4 Blade Chasis With Converged Network Connectivity For 4X32gb Fc, 4X10g Fcoe And 2X40g Connectivity, Redundant 2500W Platinum Ac Hot Plug Power Supply 5 Rack Server With 2 Xintel Latest Generation Xeon® Gold Ice Lake Processors With Minimum 2.0 Ghz & 32Coreper Socket And 48 Mb Cache., 768Gb Ddr4 2933Mhz Mem, 4X1.2Tb 12G Sas 10K Rpm Sff Hdd 6 Red Hat Cloud Infrastructure, Premium ( 2-Sockets ) With Support For 3 Years 7 High Availability For Unlimited Guests With Support For 3 Years 8 Dco, Capacity & Ito Software License For Dcim - 20 Each 9 Edb Postgres Enterprise Unicore Per Year License - Production Db Support Plan For 3 Years 10 Edb Postgres Enterprise Unicore Per Year License - Replica Db Support Plan For 3 Years 11 Ems Software Per Device For 3 Years ( As Per Technical Spec. ) 12 Red Hat Enterprise Linux Standard For Virtual Datacenters With 1 Yr Standard Subscription For 3 Years 13 Red Hat Openshift Container Platform ( Bare Metal Node ) With Run Time, Premium, 1-2 Nodes Upto 64 Cores For 3 Years 14 Version Control Software With Functional Test Automation - 10 Concurrent User, Load Runner Professional Foundation - Qty 1 ( 500 Virtual Users ) And Application Life Cycle Manager - 10 Concurrent User License With Support For 2 Years 15 Ms Sql Standard Latest Version 16 My Sql Enterprise Version ( 3 Years ) 17 Lotus Domino Email Softeare With 500 User Mail Box 18 Ddos First 2 Years - Boq - Ddos Protector Appliance With Sme Dual Power Supply Dc 19 10Gbps Pluggable Optics ( Xfp ) Multimode Sr For Ddos 20 Deployment Of Ddos Protector In Basic Configuration At The Customer Site, Including Configuration, Testing And Tuning 21 Ddos Management Va2 Virtual Appliance For Management Of 2 Ddos Protector Physical Devices For 2Y 22 Soar ( Security Orchestration Automation Response ) - Simplify Platform Base Package Premium. Includes: 2 Years License For Platform, 3 Analyst Seats, 5 Advanced Reporting Users, 24X7 Premium Support For 2 Years Incuding Implementation & Training 23 Deep Security Software - Deep Security - Enterprise - Per Server ( Vm ) 24 Ddan-Deep Discovery Analyzer 25 Vtl System, Dd4200, Ctl, Nfs, Cifs - Capacity Upgrade To 75Tb 26 Integration Of Vtl With Commvault Tape Library 27 Ups 80 Kvawith 30 Mins Battery Backup For Uninterrupted Power Supply To Active Tiles With Necessary Electrical Cabling 28 Lto 7 Tapes For Data Backup 29 Rack Containment Zone Net Work And Server Racks- Supply, Installation, Testing & Commissioning Of 42U Server Cabinet With Extruded Aluminium Profile Based Frame With Top Panel; Having Static Load Bearing Capacity Of 1300 Kg As Per Tender Specifications. . Dimensions: 2100Mm X 750Mm X 1200Mm All Complete As Requiured And As Per Detailed Specifications. Racks, Pdus, Containment Should Be From Same Oem. 30 Active Tiles For 2Nd, 3Rd & 4Th Containment 31 Perforated Tiles For 3Rd & 4Th Containment 32 Supply, Installation, Integration With Existing Infra, Testing & Commissioning Of 42U Server Cabinet Extruded Aluminium Profile Frame With Top Panel;Having Static Load Bearing Capacity Of 1300 Kg As Per Tender Specifications. . Dimensions: 2200Mm X 800Mm X 1200Mm All Complete As Required And As Per Detailed Specifications. Racks, Pdus, Containment Should Be From Same Oem 33 Supply, Installation, Testing And Intregation With Existing Infra, Commissioning & Intregation Of Single Phase 32 A , 7 Kw Zero U Vertical Rack Ipdu With Combination Of C 13 And C 19 Sockets Of Total 36 Nos. Vde Certified & Rohs Compliant As Per Technical Specifications 34 Supply, Installation, Testing Andintregation With Existing Infra, Commissioning Of Universal Cold Aisle Containment Including Wall Beams, End-Of-Row Frames, Dual Sliding Doors With Provision For Cctv Cameras , Fas Detectors ( Width - 1200Mm ) , Necessary Passive Cabling, All Complete As Required And As Per Detailed Specifications. ( For Existing And New Containment ) 35 Supply, Installation, Testing Andintregation With Existing Infra, Commissioning Of Cctv Camera Near Bms Corridor, 4Kl Ug Fuel Tank, First Floor Entry, Landing Room 36 Dismantling Of Existing False Celing And Existing Electrical Wiring, Dbs, Fire Fighting System And Modification Of Ac Duct And Opening Of Exit Door At Dr Site 37 Mineral Fiber Ceilingfalse Ceiling Of Mineral Fiber Board At Appropriateheight Should Be Installed Concealing Any Cabling Tray And Electrical Lighting Wiring In All Areas Except Server / Network Room.The False Ceiling Tile Should Be Dust Free Type And Of Noncombustible Material. 1200 Mmcross Tee At Every 600 Mm C / C And 600Mmcross Tee At Every 1200Mm C / C Max And Wall Angle All Around The Wall To Form A Grid Of 600 Mm X 600 Mm And Suspending The Grid Using 2Mm Gi Rod And 6 Mm Raw Plug At Every 1200 Mm Intervals At The Main Tee And Laying The Ceiling Tiles Of Size 595 Mm X 595 Mm X 15 Mm Over The Formed Grid Having Fire Rating Of 60 Minutes As Per Bs 476 / 23 Of 1987, Noise Reduction Coefficient ( Nrc ) Of 0.50-0.60, To Resist Temperature And Humidity Conditions Up To 40Degree ( 104Deg. F ) And Humidity Of 99% Rh Should Be Installed.All Overhead Cable Trays Will Be Secured To A Rigid Frame That Carries The Load Either To The Roof Structure Or To The Floor Slab. 38 Metalceiling For Server Room False Ceiling Of Metalboard At Appropriateheight Should Be Installed Concealing Any Cabling Tray And Electrical Lighting Wiring In All Areas Except Server / Network Room.The False Ceiling Tile Should Be Dust Free Type And Of Noncombustible Material. 1200 Mmcross Tee At Every 600 Mm C / C And 600Mmcross Tee At Every 1200Mm C / C Max And Wall Angle All Around The Wall To Form A Grid Of 600 Mm X 600 Mm And Suspending The Grid Using 2Mm Gi Rod And 6 Mm Raw Plug At Every 1200 Mm Intervals At The Main Tee And Laying The Ceiling Tiles Of Size 595 Mm X 595 Mm X 15 Mm Over The Formed Grid Having Fire Rating Of 60 Minutes As Per Bs 476 / 23 Of 1987, Noise Reduction Coefficient ( Nrc ) Of 0.50-0.60, To Resist Temperature And Humidity Conditions Up To 40Degree ( 104Deg. F ) And Humidity Of 99% Rh Should Be Installed.All Overhead Cable Trays Will Be Secured To A Rigid Frame That Carries The Load Either To The Roof Structure Or To The Floor Slab. 39 Raised Floor- Supply & Installation Of Stepped Raised Floor .The Floor Panels Shall Be Of Size 600Mm X 600Mm Fabricated Entirely From Non-Combustible Component Which Shall Be 100% Interchangeable And Shall Consist Of Flat Steel Top Sheet, Resistance Welded To Steel Bottom Section Finished With Anti Corrosive And Conductive Paint. Pedestal Assembling: Consisting Of 100X100x2 Mm Thick Galvanized Ms Base Plate Die-Pressed Fully Welded To 1.6Mm Thick Galvanized Ms Pipe To Engage The Pedestal Head Assembly. The Pedestal Head Shall Be 90X90mm, 4Mm Thk Assembly Consisting Of An Embossed Steel Plate Having 4 Holes With 6Mm Thk Taping For Fastening Of Stringer And Locating Of Tile. Care To Be Taken To Achieve The Zero Levelling. 40 Double Cup Tile Puller 41 Ramp: Its Sub Floor Elements Must Be Sufficient To Support Fully Loaded Heavy Equipment Weighing At Least 1600 Kilograms.Ramp Will Be Having Lines With Non-Skid Type Mats On Lining. The Angle Of Inclination For Ramp Should Not Be More Than 10 Degree. 42 Steps: Providing Steps At The Location Shown In Layout To Match Raised Floor Level To True Floor Level. The Steps Will Be Having Lines With Non-Skid Type Mats On Liningthe Height Of Single Step Should Not Be More Than 250 Mm And Width Should Not Be Less Than 250 Mm. 43 Tharmal Insulation With 19 Mm Nitrel Rubber 44 Providing And Applying Approved Emulsion Low Voc Paint In Three Or More Coats Of Approved Brand And Shade To Internal Sufaces ( Walls / Partitions / Ceiling Or Any Other Location As Directed ) , To Give An Even Shade To The Approval Of The Engineer, Including Putty & Horoughly Brushing The Surface Free From Foreign Matter, Sand Papering Smooth, Filling In All Holes And Cracks , Applying Lambi / Palti And Rubbing Down The Surface, Lambi / Palti Sandwitched With Two Coats Of Approved Primer, Rate To Include All Tools, Labour, Scaffolding, Primer As Required Completed As Directed By The Engineer. 45 Fire Rated Paint With Putty Work For Server Room And Electrical Room 46 Fire Rated Partition : Providing And Fixing In Position Full Height Partition Wall Of 100 Mm Thick Fire Line Gyp-Board Partition Using 12.5 Mm Thick Double Fire Line Gypboard On Both Sides With Gi Steel Metal Vertical Stud Frame Of Size 50 Mm Fixed In The Floor And Ceiling Channels Of 50 Mm Wide To Provide A Strong Partition. Glass Wool Insulation Inside Shall Be Provided As Required. Fixing Is By Self-Tapping Screw With Vertical Studs Being At 610 Mm Intervals. The Same Should Be Inclusive Of Making Cut-Outs For Switch Board, Sockets, Grill Etc. It Shall Also Include Preparing The Surface Smoothly And All As Per Manufacture’S Specification Etc. Finally Finishing With One Coat Of Approved Brand Of Fire Resistant Coating. ( Server Room And Electrical Room ) 47 Non Fire Rated Partition : Providing And Fixing In Position Full Height Partition Wall Of 100 Mm Thickgyp-Board Partition Using 12.5 Mm Thick Double Fire Line Gypboard On Both Sides With Gi Steel Metal Vertical Stud Frame Of Size 50 Mm Fixed In The Floor And Ceiling Channels Of 50 Mm Wide To Provide A Strong Partition. Glass Wool Insulation Inside Shall Be Provided As Required. Fixing Is By Self-Tapping Screw With Vertical Studs Being At 610 Mm Intervals. The Same Should Be Inclusive Of Making Cut-Outs For Switch Board, Sockets, Grill Etc. It Shall Also Include Preparing The Surface Smoothly And All As Per Manufacture’S Specification Etc. Finally Finishing With One Coat Of Approved Brand Of Fire Resistant Coating. 48 Fire Rated Door 2400 X 1500 Double Leaf In Equal Door 49 Panic Bar For Fire Exit Door 50 Fire Rated Door 2400 X 1000 Single Leaf 51 Main Flash Door At Data Centre Entrance Double Leaf 1500 X 2400 52 Bms And Manager Room Flash Door Single Leaf 1000 X 2400 Mm 53 Liner Work Station 54 Hydrolic Lo Back Chair 55 Cleanning & House Keeping Till Hand Over The Project Including Debrise Cleanning And Out From Site. 56 Sinages As Required Considering All Rooms, Danger Plat, Push, Pull, Fire Exit, Emergency Exit, 57 Drawing & Design Cost 58 Strutural Steel With Stair Case 59 Main Power Distribution Panel : Supply Installation Testing Commissioning For Main Data Centre Panel. Making Of Crca Powder Coated Sheet, Having Incommer 200 A 4 Pole Mccb With 36 Ka. Out Going : 100 A 4 Pole Mccb 3 Nos, 63 A 4 Pole Mccb 4 Nos, 32 A 4 Pole Mcb 6 Nos, With Multifunction Meter With Communication Port ( Rs 485 ) & R, Y, B, On, Off, Trip Indication Led Lamps & 500 A Rated Aluminium Bus Bar. 60 Ups Output Panel : Incomer 2 Nos 100A 4 Pole Mccb With Metering ( Mfm With Rs 485 Port , Indication Lamp And Control Mcbs ) Outgoing 32A Dp 18 Nos 61 Lighting Dbs, Bms Dbs And Raw Power Dbs 62 4 Run X 25 Sq.Mm. Copper Flexible Cable For 40 Kva Ups Input And Output Cable 63 4 Core 240 Sq.Mm. Al. Armured Cable Incomer Supply 64 4 Run X 10 Sq.Mm. Copper Flexible Cable For Lighting Db, Power Db , Bms Dbs And Pac 65 50 Sq.Mm. Copper Flexible Cable For Earthing. 66 3 Corex 4 Sq.Mm. Copper Flexible Cable For Server Rack 67 Supply Laying And Commissioning Of Power Points By 25 Mm Pvc Conduit And 2.5 Sqmm Copper Wire For Power Points And 1.5 Sq.Mm Copper Wire For Lights Points Includingmodular Switch Sockets & All Accessories. 68 Supply Fixing And Commissioning Of Power Points For Server Racks Including 32 A 3 Pin Industrial Socket 69 Supply Installation Testing Commissionong Of Chemical Earthing With 17.5 Sq.Mm. Copper Bonded Pipe For Electrod, Chemical Compund As Per Isi, Chamber High Duty Polycarbonet Cover Etc. 70 Supply And Fixing Of 25 X 6 Mm G.I Strip For 71 Earh Bus Bar Box With Copper Strip 72 10 Sqmm Single Core Cable For Dgs Earthing, Ups Earting And Server Rack Earthing 73 Light Point Wiring With 3 X 1.5 Sqmm Copper Flexible Wire And Pvc Conduit With Modular Switch & Accessories 74 Light Fixture 36W 2Ft X 2 Ft Led Tupe 75 Occupency Sensor 76 Cable Tray And Raceway : 77 300 X 50 Mm Ladder G.I Cable Tray With Support Arrangement 78 200 X 50 Mm G.I Perforated Cable Tray With Support Arrangement ( Power ) 79 200 X 50 Mm G.I Perforated Cable Tray With Support Arrangement ( Data ) 80 Ms Structural Steel For Cable Tray Support And Panel Base Frame 81 Supply & Laying Of Anti Static Rubber Mate 1.1 Kv Tested For Electrical Room As Per Isi 82 Shock Treatment Chart 83 First Aid Box 84 Cost For Devloping Of All Gfc & As Built Drawings As Per Recomendated Size Encluding Design . 85 Ups 3X20 Kva Modulerups With 30 Mins Battery Backup And All Accessaries ( Expandable Upto 4X20 Kva ) 86 Precision Ac For Server Room - Supply Of Variable Speed Dc Brushless Inverter Compressor Based Precision Air Conditioning Units; With Totallydouble Skin Side Panels With Min 15Mm 32 Kg / Cum Pu Sheet Internal Insulation , Bottom Discharge Type Complete With Dynamically Balanced Fan Driven By Electronically Commutated ( Ec ) Motor, Hydrophilic Coated Slant / Flat Cooling Coil. The Unit Shallbe Equipped With High Efficiency Filters ( G4 ) Of Minimum 100Mm Thick, Micro Processor Based Programmable Logic Controller, Liquid Receiver, Oil Separator, Llsv, Nrv, Ss Drain Tray With Nitrile Rubber Insulation , Al Strip Heater & Modulating Electrode Steam Humidifier Etc. Factory Performance Testing ( Fat ) Shall Be Carried In Presence Of Customer’S Representative. Pac Should Have Provision For Connecting Separate Input Power Of Ups Power For Fans And Controller; Raw Power For Other Components. 10.5Tr Net Sensible Capacity@ 7000 Cfm At 25 Pa Esp ; Based On Returnair Conditions: 35 + / -1 Deg. C, Rh 25% And Ambient Temperature 87 G I Hard Drawn Drain Piping 88 Supply, Installation, Testing & Commissioning Of Gi Class ‘B’ Cut To Required Lengths And Installed With All Screwed Joints, And Providing And Fixing In Position With The Necessary Elbows, Tees And Reducers As Per Specifications. It Shall Be Insulated With 9 Mm Thk Nitrile Rubber Insulation. Humidifier Piping ( Assumption Of 40 Rmt / Unit ) 25Mm Dia All Complete As Required. 89 Supply, Lifting, Shifting, & Installation Ofms Stands For Indoor Pac Units With Rubber Pads. The Frame Shall Be Painted With One Coat Of Metal Primertwo Coats Rust Proof Epoxy Paint. The Stand Shall Be Height Adjustable Type ± 25Mm For Server Room Stands All Complete As Required. 90 Refrigerant Piping: Hard Copper Piping ( 7 / 8 Liquid + 1 1 / 8 Gas ) Along With Closed Cell Elastomeric Nitrile Rubber Insulation. Refrigerant Pipe Cost Shall Incude Required Neccessary Supporting Arrangement Of Hanging , Wall Fixed Type. Cost Of Wall Chasing / Breaking And Finish, Etc All Complete As Required. 91 Refrigerant Gas R410a All Complete. 92 Refrigerant Oil All Complete As Required. 93 Supply, Laying, Installation, Testing & Commissioning Of Interconnection Cable ( 3C X2.5 Sq Mm, Armoured Cable ) Between Indoor & Outdoor Unitsall Complete. 94 Seq Cat6 Cable For Multiple Indoor Units All Complete. 95 Supply & Installation Of Ms Stands For Outdoor Pac Condenser Units With Rubber Pads. The Frame Shall Be Painted With One Coat Of Metal Primer And Two Coats Rust Proof Epoxy Paint All Complete. 96 Providing And Fixing Of Fire Sealant To Close The Cut-Outs Of Cables, Refrigerant Pipes And Tray All Complete As Required. 97 Copper Piping With Electrical Wirings For The Above 98 It Hardware Requirement At Dr Site: Blade Server Ac2 Chassis With Fans ( As Per Details Specification Shared Seperately 99 Blade With 02 Cpu, 1Tb Memory, 2*960Gb Ssd 100 San Switch : 16G Fc Switch, W / 48 Active Ports + 16G Sw Sfps 101 Certificate Server / Rack Server 102 Desktop Computer Set 103 L3 Switch 48 Port 104 L2 Switch 105 Router 106 It Software Requirement At Dr Site: Red Hat Cloud Infrastructure, Premium ( 2-Sockets With Guest Os ) Open Stack With Smart Management 107 High Availability For Unlimited Guests 108 Vmware Vcloud Suite Subscription- Per Cpu Per Year Commitment Plan - 60 Month Prepaid + Vcentre 1 Nos 109 Ems Software Per Device / Vm For 5 Years 110 Deep Security - Enterprise - Per Server ( Vm ) For 5 Years 111 Redhat Enterprise Linux Standard For Virtual Datacentres With 1 Yr Standard Subscription For 5 Years 112 San Storage Capacity Requirement At Dr Site: Hpe San Storage ( Primera 650 ) With 650 Tb ( Nl Sas ) + 50 Tb Ssd 113 Netapp San Storage ( Aff-A700 ) With 430 Tb ( Nl Sas ) + 100 Tb Ssd Features Mentioned Below 114 Enterprise Firewall As Per Specification Mentioned / Equivalent 115 24 Port ( All ) Poe+ ( 190W ) Switch With 2 Sfp Uplink Ports For Cctv 116 10M Hdmi Cable. 117 Performance Lite 2 Mp Ip Eyeball Camera Fixed Lens. 118 Cat 6 Cable 119 Performance Lite 2 Mp Ip Bullet Camera Fixed Lens. 120 H265 4K 32Ch Nvr No Poe. 121 Conduit 25 Mmm Pvc 122 49 Colour Monitor Industrial Duty 123 9 U Network Rack 124 2 Door Access Controller 125 Supply Of Smps For Door Controller. 126 Supply & Installation Of Door Controller Enclosour. 127 Biometric Reader 128 Card Reader 129 Supply Of L And U Bracket. 130 Double Door Em Lock 600 Lbs With Led 131 Z Bracket For 600Lbs Em Lock. 132 600Lbs Electromagnetic Lock Unmonitored Type 12V Led Lamp Only For Singleleafe Door. 133 Magnetic Contact 2 Wire. 134 Supply Of Acs Workstation Intel® Quad Core, 2.8Ghz Or Higher, 8 Gb Ram, 100 Gb Free Disk Space, Dual Ethernet 10 / 100Mbs, Software Requirements:* Microsoft Windows 10 ( Enterprise ) 64-Bits* Microsoft .Net Framework V4.0 135 Exit Button 3 Inches X 1 Inch. 136 Smart Access Card 137 Access Control Software 138 Supply Installation Testing & Commissioning Of Addressable Optical Smoke Detector, Smoke Detection By : Photo-Electric Light Scattering. 139 Supply Installation Testing & Commissioning Of Addressable Heat Detector, Detection Technology : Thermistor / Ror 140 Supply Installation Testing & Commissioning Of Addressable Manualcall Point With Built In Isolator And Dil Switch For Address Setting 141 Supply Installation Testing & Commissioning Of The Loop Powered 100 Db Sounder Base With Beacon 142 Supply Installation Testing & Commissioning Ofaddressable Control Module 143 Supply Installation Testing & Commissioning Ofaddressable Monitor Module 144 Supply Installation Testing & Commissioning Ofaddressable Isolator Module 145 Supply Installation Testing & Commissioning Of 2 Loop Fire Alarm Panel With 126 Addresses Per Loop, Battery And Accessories As Per Requirement. Battery Back-Up 146 2 Core X 1 Sqmm Copper Flexible Frls Cable 147 20 Mm Pvc Conduit 148 Abc Type Fire Extingusher 5 Kg 149 Sitc Of Short Wavelength Laser Based Ultra High Sensitive Aspiration Smoke Detector With Resolution Of 0.00006% Obs / Ft ( 0.0002% Obs / M, ) , 4 Pipe Inlets, Shall Support Minimum 100 Meters Pipe Length Per Pipe Inlet With Cumulative Pipe Length Up To 550 Meters For One Single Detector, 4 Alarm Levels, Optional Auto Cleaning Mechanism For Detection Chamber, On-Board Dual Stage Filter With Memory, Built-In Event Memory Of 20000 Events, Pipe Wise 4 Stage Flow Monitoring, Led Indications For Alarm And Fault Conditons. Detector Shall Support As An Inbuilt Colour Touch Screen 3.5 Display For Status Monitoring Including Smoke Level Bar Graph, Analytics To Determine Nature Of Sampled Airborne Particles ( Dust, Diesel & Pvc Wire Burning ) , Connectivity Using Rs485 & Tcp / Ip, Wi-Fi Support For Monitoring Using Smart Phones, Connection Of Additional Displays For Remote Monitoring. 150 Sitc Of Power Supply Units - Power Supply Unit With 110 / 230Vac Input And 18 To 29Vdc Output. The Power Supply Unit Has The Following Indications:Ok - Green Led And Fault - Yellow Led Power Supply Unit Should Have Capacity To Operate On Battery Backup In Case Of Ac Mains Failure & Should Have Built In Charging Circuit For Batterys. 151 Sitc Of Trunk Adaptor, Capillary Tube Connector, Capillary Tube, Capillary Sampling Point, Sampling Point Label Red ( Complete Set ) For Air Sampling In Room Voids For Area Having False Ceilings. 152 Sitc Of Sampling Pipe Having Smooth Bore Pvc Pipe 25Mm Outer Dia & 19 To 21Mm Inner Dia With All Required Accessories. 153 Supply, Installation, Testing And Commissioning Of 2 Zone Water Leak Detection Panel ( For Server Room And Electrical Room ) 154 Water Leak Detection Cable Sensor – 25 Mtrs 155 Electronic Hooter 156 Sitc Of 2 X 1.0 Sq Mm Screened Copper Flexible Cable 157 Sitc Of Main Rodent Controller Suitable To Connect 24 Satelites @ 300Sft At Room Area And 150 At Ceiling And Floor Area.Server Room 158 Sitc Of Satellite Stations / Transducers Covering 159 Cable And Conduits 160 2 Core 1 Sq.Mm Cu. Flexible Shielded Cable @ 275 Meter Each Coil 161 20 Mm Pvc Conduit 162 Console 163 Stand Brackets 164 120 Ltrs Tank And Valve Assembly With Solenoidactuator, Straps Empty ( Fill 60 - 100 Kgs. ) 165 Fire Suppression Fluid Novec1230, Oem Factory Fill Per Kg 166 Cylender Accessories 167 Cylinder Strap 168 Pneumatic Actuator Shipping Assembly 169 Local Manual Actuator 170 Flexible Discharge Hose -49 Mm / Swivel Adaptor 171 Flexible Actuation Hose / Pilot Hose 172 Nozzles, Brass Drilled -360 / 180 Deg Throw Selection 173 Led Type Display Sign Board Flashing With Inbuilt Sounder “Evacuate Gas Released” & “Do Not Enter” 174 49 Mm Manifold Check Valve 175 Pressure Switch - Dpst 176 Manual Relelase Switch 177 Abort Switch 178 M.S. Seamless Pipes As Per Astm A 106 Gr. B, Schedule 40 With Necessary Fittings & Hangers. 179 2 Way Manifold 180 Ms Channel Support 181 Gass Release Panel 182 Cross Zoning Detector 183 Hooter With Strobe 100 Db 184 Building Management System Application 185 6Kva Online Ups With 20 Minutes Backup 186 Structured Cabling & Server Racks: 10 M Cat 6 Cable 187 15 M Cat 6 Cable 188 25 M Cat 6 Cable 189 Cat-6 Utp Cable Roll Of 305 Mtrs 190 12Mtp / F-12Mtp / F Trunk Cable, Om4, Lszh, 15M, Polarity Reversed, Low-Loss 191 12Mtp / F-12Mtp / F Trunk Cable, Om4, Lszh, 25M, Polarity Reversed, Low-Loss 192 Lc-Lc Fiber Duplex Patch Cord Om4 Multimode-3 Meter 193 Lc-Lc Fiber Duplex Patch Cord Om4 Multimode-5 Meter 194 24 Core Fiber Cassette ( Mpo ) Ab / Ba Pair Flipped 24 Core Fiber Mpo Lc Cassette, Pair Flipped Ab / Ba, Multi-Mode 195 Trunk Cable ( Mpo-Mpo ) 25Meter Mpo-Mpo Trunk Male Cable, 12 Fiber Straight, 50.125 Om4 Lszh Multimode 196 Trunk Cable ( Mpo-Mpo ) 15Meter Mpo-Mpo Trunk Male Cable, 12 Fiber Straight, 50.125 Om4 Lszh Multimode 197 Dr Site Installation, Commissioning & System Integration Charges 198 Server Rack - Supply, Installation, Testing & Commissioning Of 42U Server Cabinet Extruded Aluminium Profile Frame With Top Panel;Having Static Load Bearing Capacity Of 1300 Kg As Per Tender Specifications. . Dimensions: 2200Mm X 800Mm X 1200Mm All Complete As Required And As Per Detailed Specifications. Racks, Pdus, Containment Should Be From Same Oem 199 Network Rack With Pdu 200 Manpower Requirement For 24X7 Support: Bms Person -3 Persons For 5 Years 201 It - L1 / L2- 2 Persons For 5 Years 202 Dedicated Dc-Dr Link & Ill - 500 Mbps Dc-Dr Lc With 1 Year Arc 203 100 Mbps Ill For With 1 Year Arc 204 Providing Of 2 Nos Physical Security For Sdc.Fy-23-24 205 Providing Of 2 Nos Physical Security For Sdc.Fy-24-25 206 Providing Of 2 Nos Physical Security For Sdc.Fy-25-26 207 Fm Cost For 5 Years As Per Requirement Mentioned In Existing Dco Terms & Conditionsfy-23-24 208 Fm Cost For 5 Years As Per Requirement Mentioned In Existing Dco Terms & Conditionsfy-24-25 209 Fm Cost For 5 Years As Per Requirement Mentioned In Existing Dco Terms & Conditionsfy-25-26 210 Amc / Support Cost For Lt ( Software And Hardware ) Equipmentfy-23-24 211 Amc / Support Cost For Lt ( Software And Hardware ) Equipmentfy-24-25 212 Amc / Support Cost For Lt ( Software And Hardware ) Equipmentfy-25-26 213 Amc / Support Cost For Non-Lt Equipment ( 2Nd Floor ) Fy-23-24 214 Amc / Support Cost For Non-Lt Equipment ( 2Nd Floor ) Fy-24-25 215 Amc / Support Cost For Non-Lt Equipment ( 2Nd Floor ) Fy-25-26 216 Amc / Support Cost For Non-Lt Equipment ( 1St Floor ) Fy-23-24 217 Amc / Support Cost For Non-Lt Equipment ( 1St Floor ) Fy-24-25 218 Amc / Support Cost For Non-Lt Equipment ( 1St Floor ) Fy-25-26 219 Amc / Support Cost For Pac, Ups, Panel & Dg. ( 1St Floor ) ) Fy-23-24 220 Amc / Support Cost For Pac, Ups, Panel & Dg. ( 1St Floor ) ) Fy-24-25 221 Amc / Support Cost For Pac, Ups, Panel & Dg. ( 1St Floor ) ) Fy-25-26 222 Cost Of Dedicated Operation And Amc Support For Rsa Siem For Wbsdc Through L2 Level Engineerfy-22-23 223 Cost Of Dedicated Operation And Amc Support For Rsa Siem For Wbsdc Through L2 Level Engineerfy-23-24 224 Cost Of Dedicated Operation And Amc Support For Rsa Siem For Wbsdc Through L2 Level Engineerfy-24-25 225 Cost Of Dedicated Operation And Amc Support For Rsa Siem For Wbsdc Through L2 Level Engineerfy-25-26 226 Amc / Support Cost For Ups Batteries For 2 Years ( 4Th & 5Th Years ) , Post Initial 3 Years Warranty Period For 204 Cells Of 2V / 357Ahfy-23-24 227 Amc / Support Cost For Ups Batteries For 2 Years ( 4Th & 5Th Years ) , Post Initial 3 Years Warranty Period For 204 Cells Of 2V / 357Ahfy-24-25 228 Amc / Support Cost For Ups Batteries For 2 Years ( 4Th & 5Th Years ) , Post Initial 3 Years Warranty Period For 204 Cells Of 2V / 357Ahfy-25-26 229 Professional Support Services For One Database And One System Administrators With Effect From 1.4.2022Fy-22-23 230 Professional Support Services For Two Database And Two System Administrators With Effect From 1.4.2022Fy-23-24 231 Professional Support Services For Three Database And Three System Administrators With Effect From 1.4.2022Fy-24-25 232 Professional Support Services For Three Database And Three System Administrators With Effect From 1.4.2022Fy-25-26 233 Vodafone / Other Isp 1000 Mbps Ill For Wbsdc For 1 Year Upto 31.03.2022Fy-21-22 234 Vodafone / Other Isp 1000 Mbps Ill For Wbsdc For 1 Year Upto 31.03.2023Fy-22-23 235 Vodafone / Other Isp 1000 Mbps Ill For Wbsdc For 1 Year Upto 31.03.2024Fy-23-24 236 Vodafone / Other Isp 1000 Mbps Ill For Wbsdc For 1 Year Upto 31.03.2025Fy-24-25 237 Vodafone / Other Isp 1000 Mbps Ill For Wbsdc For 1 Year Upto 31.03.2026Fy-25-26 238 Amc & Upgrade Of Old Sdc Cloud Servers ( 4 ) Fy-22-23 239 Amc & Upgrade Of Old Sdc Cloud Servers ( 4 ) Fy-23-24 240 Amc & Upgrade ( 30 To 75Tb ) Of Dell Vtl Of Old Sdc Cloud System Period From 1 / 4 / 2022 To 31 / 3 / 2023Fy-22-23 241 Amc Of Upgraded Dell Vtl Of Old Sdc Cloud System Period From 1 / 4 / 2023 To 31 / 3 / 2024Fy-23-24 242 Amc & Upgrade ( 75 To 100Tb ) Of Dell Vtl Of Old Sdc Cloud System Period From 1 / 4 / 2024 To 31 / 3 / 2025Fy-24-25 243 Amc Of Upgraded Dell Vtl Of Old Sdc Cloud System Period From 1 / 4 / 2025 To 31 / 3 / 2026Fy-25-26 244 Amc / Ats & Upgrade ( From 40 To 60Tb ) Of Commvault Backup System From 2023Fy-23-24 245 Amc / Ats ( 60Tb ) Of Commvault Backup System From 2023Fy-24-25 246 Amc / Ats ( 60Tb ) Of Commvault Backup System From 2023Fy-25-26 247 Amc Of Wbsdc New Cloud ( Blade ) Servers - Lot Onefy-23-24 248 Amc Of Wbsdc New Cloud ( Blade ) Servers - Lot Onefy-24-25 249 Amc Of Wbsdc New Cloud ( Blade ) Servers - Lot Onefy-25-26 250 Amc Of Netapp San Storage ( 430 Tb ) For The Period From 2023Fy-23-24 251 Amc Of Netapp San Storage ( 430 Tb ) For The Period From 2023Fy-24-25 252 Amc Of Netapp San Storage ( 430 Tb ) For The Period From 2023Fy-25-26 253 Amc Of Wbsdc New Network ( Sdn ) Infrastructurefy-23-24 254 Amc Of Wbsdc New Network ( Sdn ) Infrastructurefy-24-25 255 Amc Of Wbsdc New Network ( Sdn ) Infrastructurefy-25-26 256 Amc & Upgrade Of Redhatopenstack Cloud Software License Sa For Fy-23-24 257 Amc & Upgrade Of Redhatopenstack Cloud Software License Sa For Fy-24-25 258 Amc & Upgrade Of Redhatopenstack Cloud Software License Sa For Fy-25-26 259 Renewal Of Rsa Software Product Licenses With Oem Support For 1 Yearfy-22-23 260 Renewal Of Rsa Software Product Licenses With Oem Support For 1 Yearfy-23-24 261 Renewal Of Rsa Software Product Licenses With Oem Support For 1 Yearfy-24-25 262 Renewal Of Rsa Software Product Licenses With Oem Support For 1 Yearfy-25-26 263 Soar ( Security Orchestration Automation Response ) Software License Renewalfy-24-25 264 Soar ( Security Orchestration Automation Response ) Software License Renewalfy-25-26 265 Ddos 10Gbps Additional 1 Years Subscriptionfy-24-25 266 Ddos 10Gbps Additional 1 Years Subscriptionfy-25-26 267 Dc Augmentation - Installation, Commissioning & System Integration Charges 268 Deep Security Enterprise Software License - Additional 150 Vms For 2 Years During Fy-21-22 269 Deep Security Enterprise Software License - Additional 50 Vms For 1 Years & License Renewals For All Existing Licenses During Fy-22-23 270 Deep Security Enterprise Software License - Additional 50 Vms For 1 Years & License Renewals For All Existing Licenses For Yearfy-23-24 271 Deep Security Enterprise Software License - Additional 50 Vms For 1 Years & License Renewals For All Existing Licenses For Yearfy-24-25 272 Deep Security Enterprise Software License - Additional 50 Vms For 1 Years & License Renewals For All Existing Licenses For Yearfy-25-26 273 Edb Postgres Enterprise License Cpu Core Support Renewal / Upgrade - Production Support ( Including Replica Db Servers ) Fy-21-22 274 Edb Postgres Enterprise License Cpu Core Support Renewal / Upgrade - Production Support ( Including Replica Db Servers ) Fy-22-23 275 Edb Postgres Enterprise License Cpu Core Support Renewal / Upgrade - Production Support ( Including Replica Db Servers ) Fy-23-24 276 Edb Postgres Enterprise License Cpu Core Support Renewal / Upgrade - Production Support ( Including Replica Db Servers ) Fy-24-25 277 Edb Postgres Enterprise License Cpu Core Support Renewal / Upgrade - Production Support ( Including Replica Db Servers ) Fy-25-26 278 Vmware Vcloud Suite Subscriptionper Cpu 20 Cpus Commitment Plan - 12 Month Prepaid With Supportfy-22-23 279 Vmware Vcloud Suite Subscriptionper Cpu 20 Cpus Commitment Plan - 12 Month Prepaid With Supportfy-23-24 280 Vmware Vcloud Suite Subscriptionper Cpu 20 Cpus Commitment Plan - 12 Month Prepaid With Supportfy-24-25 281 Vmware Vcloud Suite Subscriptionper Cpu 20 Cpus Commitment Plan - 12 Month Prepaid With Supportfy-25-26 282 Dc-Dr Lc & Ill Arc For Dr Sitefy-22-23 283 Dc-Dr Lc & Ill Arc For Dr Sitefy-23-24 284 Dc-Dr Lc & Ill Arc For Dr Sitefy-24-25 285 Dc-Dr Lc & Ill Arc For Dr Sitefy-25-26 286 Capacitor Bank Change Of Old Upsfy-21-22 287 Capacitor Bank Change Of Old Upsfy-24-25 288 Electrical Earth Pit Repair / Reconstructionfy-22-23 289 Dg Repair / Replacement Due To Aging / Obsolescencefy-22-23 290 Dg Repair / Replacement Due To Aging / Obsolescencefy-24-25

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Dec-2021 CORRIGENDUM1 Technical Bid 27-12-2021
2 20-Dec-2021 CORRIGENDUM2 Date 14-01-2022
3 24-Dec-2021 CORRIGENDUM 3 Technical Bid 14-01-2022
4 24-Dec-2021 CORRIGENDUM 4 BOQ 14-01-2022
5 10-Jan-2022 CORRIGENDUM5 Date 21-01-2022
6 14-Jan-2022 CORRIGENDUM7 BOQ 21-01-2022
7 14-Jan-2022 CORRIGENDUM6 Technical Bid 21-01-2022
8 21-Jan-2022 CORRIGENDUM8 Date 21-02-2022
9 31-Jan-2022 CORRIGENDUM 9 Other 21-02-2022
10 07-Feb-2022 CORRIGENDUM10 Technical Bid 21-02-2022
11 16-Feb-2022 CORRIGENDUM11 Technical Bid 21-02-2022
12 21-Feb-2022 CORRIGENDUM12 Date 09-03-2022

Key Value

Document Fees
INR 10000 /-
EMD
INR 12000000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Selection of System Integrator for Capacity Enhancement of West Bengal State Data Centre (WB - SDC) and setting up its DR site at Remote Location.
Sl. No. Item Description
1HPE Storage DC (Primera 650) - 450TB upgrade to 650TB (+100TB SSD + 100TB SAS)
2Netapp Storage DC (AFF-A700) - 170TB upgrade to 430TB (+260TB SSD)
3Blade server with 2 x Intel 6238R 2.2GHz/165W 28C/38.5MB,1536GB DDR4 2933MHz mem, 2x960GB 12G SAS 10K RPM SFF HDD, 12G SAS RAID controller with Drive bays
4Blade Chasis with converged network connectivity for 4x32GB FC, 4x10G FCOE and 2x40G connectivity, Redundant 2500W Platinum AC Hot Plug Power Supply
5Rack Server with 2 xIntel latest generation Xeon® Gold Ice Lake Processors with minimum 2.0 Ghz & 32Coreper socket and 48 MB Cache., 768GB DDR4 2933MHz mem, 4x1.2TB 12G SAS 10K RPM SFF HDD
6Red Hat Cloud Infrastructure, Premium (2-sockets) with support for 3 years
7High Availability for Unlimited Guests with support for 3 years
8DCO, Capacity & ITO Software License for DCIM - 20 Each
9EDB Postgres Enterprise Unicore per year license - Production DB Support Plan for 3 years
10EDB Postgres Enterprise Unicore per year license - Replica DB Support Plan for 3 years
11EMS Software per device for 3 years (as per technical spec.)
12Red hat Enterprise Linux Standard for virtual Datacenters with 1 Yr Standard Subscription for 3 years
13Red hat Openshift Container Platform (Bare Metal Node) with run time, Premium, 1-2 Nodes upto 64 Cores for 3 years
14Version Control Software with Functional test automation - 10 Concurrent User, Load runner professional foundation - qty 1 (500 virtual users) and Application Life Cycle Manager - 10 concurrent user license with support for 2 years
15MS SQL Standard Latest version
16My SQL enterprise version (3 years)
17Lotus Domino Email softeare with 500 user mail box
18DDOS First 2 Years - BOQ - DDoS Protector appliance with SME Dual Power Supply DC
1910Gbps Pluggable Optics (XFP) Multimode SR for DDOS
20Deployment of DDoS Protector in basic configuration at the customer site, including configuration, testing and tuning
21DDoS Management VA2 Virtual Appliance for management of 2 DDoS Protector physical devices for 2Y
22SOAR (Security Orchestration Automation Response) - Simplify Platform Base Package Premium. Includes: 2 years License for Platform, 3 analyst seats, 5 Advanced Reporting Users, 24x7 Premium support for 2 Years incuding implementation & training
23Deep Security Software - Deep Security - Enterprise - per Server (VM)
24DDAN-Deep Discovery Analyzer
25VTL SYSTEM,DD4200,CTL,NFS,CIFS - CAPACITY UPGRADE to 75TB
26Integration of VTL with Commvault Tape Library
27UPS 80 KVAwith 30 mins battery backup for uninterrupted power supply to active tiles with necessary electrical cabling
28LTO 7 Tapes for Data Backup
29Rack Containment Zone Net Work and Server Racks- Supply, Installation, Testing & Commissioning of 42U Server Cabinet with Extruded Aluminium Profile based frame with top panel; having Static load bearing capacity of 1300 Kg as per Tender specifications. . Dimensions: 2100mm x 750mm x 1200mm all complete as requiured and as per detailed specifications. Racks, PDUs, containment should be from same OEM.
30Active tiles for 2nd,3rd & 4th containment
31Perforated tiles for 3rd & 4th containment
32Supply, Installation, Integration with existing infra, Testing & Commissioning of 42U Server Cabinet Extruded Aluminium Profile frame with top panel;having static load bearing capacity of 1300 Kg as per Tender specifications. . Dimensions: 2200mm x 800mm x 1200mm all complete as required and as per detailed specifications. Racks, PDUs, containment should be from same OEM
33Supply, Installation, testing and intregation with existing infra, Commissioning & Intregation of Single Phase 32 A , 7 kW Zero U Vertical Rack IPDU with combination of C 13 and C 19 sockets of total 36 Nos. VDE Certified & ROHS Compliant as per technical specifications
34Supply, Installation, Testing andintregation with existing infra, Commissioning of Universal Cold Aisle Containment including wall beams, end-of-row frames, dual sliding doors with provision for CCTV Cameras , FAS detectors (Width - 1200mm), necessary passive cabling, all complete as required and as per detailed specifications.( for existing and new containment)
35Supply, Installation, Testing andintregation with existing infra, Commissioning of CCTV camera near BMS corridor, 4kl UG Fuel tank, First floor entry, Landing room
36Dismantling of existing false celing and existing electrical wiring, DBs, Fire fighting system and Modification of AC duct and opening of Exit Door at DR Site
37Mineral Fiber Ceiling False Ceiling of Mineral fiber board at appropriateheight should be installed concealing any cabling tray and electrical lighting wiring in all areas except server/network room. The False Ceiling tile should be Dust free type and of Noncombustible material. 1200 mmcross tee at every 600 mm c/c and 600mmcross tee at every 1200mm c/c max and wall angle all around the wall to form a grid of 600 mm x 600 mm and suspending the grid using 2mm GI rod and 6 mm raw plug at every 1200 mm intervals at the main tee and laying the Ceiling tiles of size 595 mm x 595 mm x 15 mm over the formed grid having fire rating of 60 minutes as per BS 476/23 of 1987, Noise reduction Coefficient (NRC) of 0.50-0.60, to resist temperature and humidity conditions up to 40degree (104deg. F) and humidity of 99% RH should be installed. All overhead cable trays will be secured to a rigid frame that carries the load either to the roof structure or to the floor slab.
38MetalCeiling for Server Room False Ceiling of Metalboard at appropriateheight should be installed concealing any cabling tray and electrical lighting wiring in all areas except server/network room. The False Ceiling tile should be Dust free type and of Noncombustible material. 1200 mmcross tee at every 600 mm c/c and 600mmcross tee at every 1200mm c/c max and wall angle all around the wall to form a grid of 600 mm x 600 mm and suspending the grid using 2mm GI rod and 6 mm raw plug at every 1200 mm intervals at the main tee and laying the Ceiling tiles of size 595 mm x 595 mm x 15 mm over the formed grid having fire rating of 60 minutes as per BS 476/23 of 1987, Noise reduction Coefficient (NRC) of 0.50-0.60, to resist temperature and humidity conditions up to 40degree (104deg. F) and humidity of 99% RH should be installed. All overhead cable trays will be secured to a rigid frame that carries the load either to the roof structure or to the floor slab.
39Raised Floor- Supply & Installation of stepped raised floor .The floor panels shall be of size 600mm x 600mm fabricated entirely from non-combustible component which shall be 100% interchangeable and shall consist of flat steel top sheet, resistance welded to steel bottom section finished with anti corrosive and conductive paint. Pedestal assembling: Consisting of 100x100x2 mm thick galvanized MS base plate die-pressed fully welded to 1.6mm thick galvanized MS pipe to engage the Pedestal head assembly. The Pedestal head shall be 90x90mm, 4mm thk assembly consisting of an embossed steel plate having 4 holes with 6mm thk taping for fastening of stringer and locating of Tile. Care to be taken to achieve the zero levelling.
40Double Cup Tile Puller
41Ramp: Its sub floor elements must be sufficient to support fully loaded heavy equipment weighing at least 1600 kilograms. Ramp will be having lines with non-skid type mats on lining. The angle of inclination for ramp should not be more than 10 degree.
42Steps: Providing steps at the location shown in layout to match raised floor level to true floor level. The steps will be having lines with non-skid type mats on liningThe height of single step should not be more than 250 mm and width should not be less than 250 mm.
43Tharmal insulation with 19 mm Nitrel rubber
44Providing and Applying approved Emulsion Low VOC paint in three or more coats of approved brand and shade to internal sufaces (walls / partitions/ ceiling or any other location as directed),to give an even shade to the approval of the engineer, including Putty & horoughly brushing the surface free from foreign matter, sand papering smooth, filling in all holes and cracks , applying lambi / palti and rubbing down the surface, lambi/palti sandwitched with two coats of approved primer, rate to include all tools, labour, scaffolding, primer as required completed as directed by the engineer.
45Fire Rated Paint with putty work for Server Room and Electrical Room
46Fire Rated Partition : Providing and fixing in position full height partition wall of 100 mm thick fire line gyp-board partition using 12.5 mm thick double fire line gypboard on both sides with GI steel metal vertical stud frame of size 50 mm fixed in the floor and ceiling channels of 50 mm wide to provide a strong partition. Glass wool insulation inside shall be provided as required. Fixing is by self-tapping screw with vertical studs being at 610 mm intervals. The same should be inclusive of making cut-outs for switch board, sockets, grill etc. It shall also include preparing the surface smoothly and all as per manufacture’s specification etc. finally finishing with one coat of approved brand of fire resistant coating. ( Server Room and Electrical Room )
47Non Fire Rated Partition : Providing and fixing in position full height partition wall of 100 mm thickgyp-board partition using 12.5 mm thick double fire line gypboard on both sides with GI steel metal vertical stud frame of size 50 mm fixed in the floor and ceiling channels of 50 mm wide to provide a strong partition. Glass wool insulation inside shall be provided as required. Fixing is by self-tapping screw with vertical studs being at 610 mm intervals. The same should be inclusive of making cut-outs for switch board, sockets, grill etc. It shall also include preparing the surface smoothly and all as per manufacture’s specification etc. finally finishing with one coat of approved brand of fire resistant coating.
48Fire rated door 2400 x 1500 double leaf in equal door
49Panic bar for fire exit door
50Fire rated door 2400 x 1000 single leaf
51Main Flash Door at Data Centre Entrance double leaf 1500 x 2400
52BMS and Manager Room Flash Door single leaf 1000 x 2400 mm
53Liner work station
54Hydrolic lo back chair
55Cleanning & house keeping till hand over the project including debrise cleanning and out from site.
56Sinages as required considering all rooms, Danger plat, Push, Pull, Fire exit, Emergency exit,
57Drawing & Design cost
58Strutural Steel with Stair case
59Main Power Distribution Panel : Supply Installation testing commissioning for Main Data Centre Panel. making of CRCA powder coated sheet, Having Incommer 200 A 4 pole MCCB with 36 KA. Out Going : 100 A 4 pole MCCB 3 nos, 63 A 4 pole MCCB 4 Nos, 32 A 4 pole MCB 6 nos, with multifunction meter with communication port ( RS 485) & R,Y, B, ON, OFF, Trip Indication LED lamps & 500 A rated Aluminium bus bar.
60UPS Output Panel : Incomer 2 Nos 100A 4 Pole MCCB with Metering ( MFM with RS 485 Port , Indication lamp and control MCBs ) Outgoing 32A DP 18 Nos
61Lighting DBs, BMS DBs and Raw Power DBs
624 Run X 25 sq.mm. copper flexible cable for 40 KVA UPS Input and Output cable
634 Core 240 sq.mm. AL. Armured cable Incomer Supply
644 Run X 10 sq.mm. copper flexible cable for Lighting DB, Power DB , BMS DBs and PAC
6550 sq.mm. copper flexible cable for earthing.
663 CoreX 4 sq.mm. copper flexible cable for server rack
67Supply laying and commissioning of power points by 25 mm PVC conduit and 2.5 sqmm copper wire for power points and 1.5 sq.mm copper wire for lights points includingmodular switch sockets & all accessories.
68Supply fixing and commissioning of power points for server racks including 32 A 3 pin industrial socket
69Supply Installation testing commissionong of chemical earthing with 17.5 sq.mm. copper bonded pipe for electrod, chemical compund as per ISI, Chamber High duty Polycarbonet cover etc.
70Supply and fixing of 25 x 6 mm G.I Strip for
71Earh Bus bar box with copper strip
7210 sqmm single core cable for DGs earthing, UPS earting and server Rack earthing
73Light Point wiring with 3 x 1.5 sqmm copper flexible wire and PVC conduit with modular switch & accessories
74Light fixture 36W 2ft x 2 Ft LED tupe
75Occupency Sensor
76Cable tray and raceway :
77300 x 50 mm Ladder G.I cable tray with support arrangement
78200 x 50 mm G.I perforated cable tray with support arrangement ( Power )
79200 x 50 mm G.I perforated cable tray with support arrangement ( Data)
80MS structural Steel for cable tray support and Panel Base Frame
81Supply & Laying of Anti static rubber mate 1.1 kv tested for electrical room as per ISI
82Shock Treatment chart
83First Aid Box
84Cost for devloping of all GFC & As built drawings as per recomendated size encluding design .
85UPS 3x20 KVA ModulerUPS with 30 mins battery backup and all accessaries (expandable upto 4x20 kva)
86Precision AC for Server Room - Supply of Variable speed DC brushless Inverter compressor based Precision Air Conditioning Units; with totallyDouble skin side panels with min 15mm 32 Kg/ cum PU sheet internal insulation , Bottom discharge type complete with dynamically balanced fan driven by Electronically Commutated (EC) motor, hydrophilic coated slant/flat cooling coil. The unit shallbe equipped with high efficiency filters(G4) of minimum 100mm thick, micro processor based programmable logic controller,Liquid receiver, Oil Separator, LLSV, NRV, SS drain tray with nitrile rubber insulation ,AL strip Heater & modulating Electrode steam Humidifier etc. Factory performance Testing (FAT) shall be carried in presence of Customer’s Representative. PAC should have provision for connecting separate input power of UPS power for fans and controller; Raw power for other components. 10.5TR NET Sensible Capacity@ 7000 CFM at 25 Pa ESP ; based on Returnair conditions: 35 +/-1 Deg. C, RH 25% and ambient temperature
87G I hard drawn drain piping
88Supply, installation, testing & commissioning of GI class ‘B’ cut to required lengths and installed with all screwed joints, and providing and fixing in position with the necessary elbows, tees and reducers as per specifications. It shall be insulated with 9 mm thk nitrile rubber insulation. Humidifier Piping (assumption of 40 RMT/unit) 25mm dia all complete as required.
89Supply, Lifting, shifting, & Installation ofMS Stands for indoor PAC units with rubber pads. The frame shall be painted with one coat of metal primertwo coats rust proof Epoxy Paint. The stand shall be Height adjustable type ± 25mm for Server Room stands all complete as required.
90REFRIGERANT PIPING: Hard copper piping (7/8" Liquid + 1 1/8" Gas) along with closed cell elastomeric nitrile rubber insulation. Refrigerant pipe cost shall incude required neccessary supporting arrangement of hanging , wall fixed type. cost of wall chasing/ breaking and finish, etc all complete as required.
91Refrigerant gas R410A all complete.
92Refrigerant Oil all complete as required.
93Supply, Laying, installation, Testing & Commissioning of Interconnection cable(3C X2.5 SQ MM, Armoured Cable) between Indoor & Outdoor unitsall complete.
94Seq CAT6 cable for multiple Indoor units all complete.
95Supply & Installation of MS Stands for outdoor PAC condenser units with rubber pads. The frame shall be painted with one coat of metal primer and two coats rust proof Epoxy Paint all complete.
96Providing and Fixing of Fire Sealant to close the cut-outs of Cables, refrigerant pipes and tray all complete as required.
97Copper piping with electrical wirings for the above
98IT Hardware Requirement at DR Site: Blade Server AC2 Chassis with fans (As per details specification shared seperately
99Blade With 02 CPU, 1TB Memory, 2*960GB SSD
100SAN Switch : 16G FC switch, w/ 48 active ports + 16G SW SFPs
101Certificate Server/Rack Server
102Desktop Computer set
103L3 Switch 48 port
104L2 Switch
105Router
106IT Software Requirement at DR Site: Red Hat Cloud Infrastructure, Premium (2-sockets with guest OS) open Stack with Smart Management
107High Availability for Unlimited Guests
108VMware vCloud Suite Subscription- per CPU per year Commitment Plan - 60 month Prepaid + Vcentre 1 Nos
109EMS Software per device/VM for 5 years
110Deep Security - Enterprise - per Server (VM) for 5 years
111Redhat Enterprise Linux Standard for virtual Datacentres with 1 Yr Standard Subscription for 5 years
112SAN Storage Capacity Requirement at DR Site: HPE SAN Storage( Primera 650) with 650 TB (NL SAS)+ 50 TB SSD
113NetApp SAN Storage (AFF-A700) with 430 TB (NL SAS) + 100 TB SSD features mentioned below
114Enterprise Firewall as per specification mentioned/Equivalent
11524 Port (all) PoE+(190W) switch with 2 SFP uplink ports for CCTV
11610M HDMI CABLE.
117Performance Lite 2 MP IP Eyeball Camera Fixed lens.
118CAT 6 Cable
119Performance Lite 2 MP IP Bullet Camera Fixed lens.
120H265 4K 32CH NVR NO POE.
121Conduit 25 mmm PVC
12249" Colour Monitor Industrial duty
1239 U Network Rack
1242 door access Controller
125Supply of SMPS for Door Controller.
126Supply & Installation of Door controller Enclosour.
127Biometric Reader
128Card Reader
129Supply of "L" and "U" Bracket.
130Double Door EM Lock 600 lbs with LED
131Z bracket for 600lbs EM Lock.
132600lbs electromagnetic lock unmonitored type 12V LED Lamp Only for Singleleafe door.
133MAGNETIC CONTACT 2 WIRE.
134Supply of ACS Workstation Intel® Quad Core, 2.8GHz or higher, 8 GB RAM, 100 GB free disk space, Dual Ethernet 10/100MBs, Software Requirements: * Microsoft Windows 10 (Enterprise) 64-bits * Microsoft .NET Framework v4.0
135Exit Button 3 inches X 1 inch.
136Smart Access Card
137Access Control software
138Supply Installation Testing & Commissioning of addressable Optical Smoke Detector, Smoke Detection by : Photo-electric light scattering.
139Supply Installation Testing & Commissioning of addressable Heat Detector, Detection Technology : Thermistor / ROR
140Supply Installation Testing & Commissioning of Addressable Manualcall point with built in isolator and DIL switch for Address Setting
141Supply Installation Testing & Commissioning of The Loop Powered 100 dB Sounder Base with Beacon
142Supply Installation Testing & Commissioning ofAddressable Control Module
143Supply Installation Testing & Commissioning ofAddressable Monitor Module
144Supply Installation Testing & Commissioning ofAddressable Isolator module
145Supply Installation Testing & Commissioning of 2 Loop Fire Alarm Panel with 126 Addresses per Loop, Battery and accessories as per requirement. Battery Back-up
1462 core x 1 sqmm Copper Flexible FRLS Cable
14720 mm PVC Conduit
148ABC Type Fire Extingusher 5 Kg
149SITC of short wavelength laser based ultra high sensitive aspiration smoke  detector with resolution of 0.00006% obs/ft (0.0002% obs/m,), 4 pipe inlets, shall support minimum 100 meters pipe length per pipe inlet with cumulative pipe length up to 550 meters for one single detector, 4 alarm levels, optional auto cleaning mechanism for detection chamber, on-board dual stage filter with memory, built-in event memory of 20000 events, pipe wise 4 stage flow monitoring, LED indications for alarm and  fault conditons. Detector shall support as an inbuilt colour touch screen 3.5" display for status monitoring including smoke  level bar graph,  analytics to determine nature of sampled airborne particles (dust, diesel & PVC wire burning), connectivity using RS485 & TCP/IP, Wi-Fi support for monitoring using  smart phones, connection of additional displays for remote monitoring.
150SITC of Power Supply units -  Power supply unit with 110/230VAC input and 18 to 29VDC output. The power supply unit has the following indications: OK - Green LED and Fault - Yellow LED Power supply unit should have capacity to operate on battery backup in case of AC mains failure & should have built in charging circuit for batterys.
151SITC of Trunk Adaptor, Capillary Tube Connector, Capillary Tube, Capillary Sampling Point,  Sampling point label red (complete set) for air sampling in room voids for area having false ceilings.
152SITC of Sampling Pipe having Smooth bore PVC Pipe 25mm Outer Dia & 19 to 21mm Inner Dia with all required accessories.
153Supply, Installation,Testing and Commissioning of 2 ZONE Water Leak Detection Panel (for server Room and Electrical Room)
154Water Leak detection Cable Sensor – 25 mtrs
155Electronic Hooter
156SITC of 2 x 1.0 sq mm screened copper flexible cable
157SITC of Main Rodent Controller suitable to connect 24 Satelites @ 300sft at room area and 150 at ceiling and floor area.Server Room
158SITC of Satellite Stations / Transducers covering
159Cable and Conduits
1602 core 1 sq.mm Cu. Flexible Shielded cable @ 275 meter each coil
16120 mm PVC Conduit
162Console
163Stand Brackets
164120 ltrs Tank and valve assembly with solenoid actuator, straps Empty (fill 60 - 100 Kgs.)
165Fire Suppression Fluid Novec1230, OEM Factory Fill per KG
166Cylender Accessories
167Cylinder strap
168Pneumatic Actuator Shipping assembly
169Local Manual actuator
170Flexible discharge Hose -49 mm / SWIVEL ADAPTOR
171Flexible Actuation Hose / Pilot hose
172Nozzles, Brass drilled -360/180 deg throw selection
173LED type display sign board flashing with inbuilt Sounder “EVACUATE GAS RELEASED” & “DO NOT ENTER”
17449 mm MANIFOLD CHECK VALVE
175PRESSURE SWITCH - DPST
176MANUAL RELELASE SWITCH
177ABORT SWITCH
178M.S. Seamless pipes as per ASTM A 106 Gr. B, schedule 40 with necessary Fittings & Hangers.
1792 WAY MANIFOLD
180MS Channel support
181Gass Release Panel
182Cross Zoning Detector
183Hooter with strobe 100 DB
184BUILDING MANAGEMENT SYSTEM APPLICATION
1856KVA online UPS with 20 minutes backup
186Structured cabling & Server racks: 10 M Cat 6 Cable
18715 M Cat 6 Cable
18825 M Cat 6 Cable
189Cat-6 UTP Cable Roll of 305 Mtrs
19012MTP/F-12MTP/F Trunk Cable, OM4, LSZH, 15m, polarity Reversed, Low-Loss
19112MTP/F-12MTP/F Trunk Cable, OM4, LSZH, 25m, polarity Reversed, Low-Loss
192LC-LC Fiber Duplex Patch Cord OM4 Multimode-3 Meter
193LC-LC Fiber Duplex Patch Cord OM4 Multimode-5 Meter
19424 Core Fiber Cassette (MPO) AB/BA Pair Flipped 24 Core fiber MPO LC Cassette, Pair Flipped AB/BA, Multi-Mode
195Trunk Cable (MPO-MPO) 25Meter MPO-MPO Trunk Male cable, 12 Fiber straight, 50.125 OM4 LSZH Multimode
196Trunk Cable (MPO-MPO) 15Meter MPO-MPO Trunk Male cable, 12 Fiber straight, 50.125 OM4 LSZH Multimode
197DR Site Installation, Commissioning & System Integration Charges
198Server Rack - Supply, Installation, Testing & Commissioning of 42U Server Cabinet Extruded Aluminium Profile frame with top panel;having static load bearing capacity of 1300 Kg as per Tender specifications. . Dimensions: 2200mm x 800mm x 1200mm all complete as required and as per detailed specifications. Racks, PDUs, containment should be from same OEM
199Network Rack with PDU
200Manpower Requirement for 24x7 Support: BMS Person -3 persons for 5 years
201IT - L1/L2- 2 persons for 5 years
202Dedicated DC-DR Link & ILL - 500 Mbps DC-DR LC with 1 Year ARC
203100 Mbps ILL for with 1 Year ARC
204Providing of 2 Nos physical security for SDC.FY-23-24
205Providing of 2 Nos physical security for SDC.FY-24-25
206Providing of 2 Nos physical security for SDC.FY-25-26
207FM Cost for 5 Years as per requirement mentioned in existing DCO terms & conditionsFY-23-24
208FM Cost for 5 Years as per requirement mentioned in existing DCO terms & conditionsFY-24-25
209FM Cost for 5 Years as per requirement mentioned in existing DCO terms & conditionsFY-25-26
210AMC/Support Cost for lT (software and hardware) equipmentFY-23-24
211AMC/Support Cost for lT (software and hardware) equipmentFY-24-25
212AMC/Support Cost for lT (software and hardware) equipmentFY-25-26
213AMC/Support Cost for Non-lT Equipment (2nd Floor)FY-23-24
214AMC/Support Cost for Non-lT Equipment (2nd Floor)FY-24-25
215AMC/Support Cost for Non-lT Equipment (2nd Floor)FY-25-26
216AMC/Support Cost for Non-lT Equipment (1st Floor)FY-23-24
217AMC/Support Cost for Non-lT Equipment (1st Floor)FY-24-25
218AMC/Support Cost for Non-lT Equipment (1st Floor)FY-25-26
219AMC/Support Cost for PAC, UPS, Panel & DG. (1st Floor))FY-23-24
220AMC/Support Cost for PAC, UPS, Panel & DG. (1st Floor))FY-24-25
221AMC/Support Cost for PAC, UPS, Panel & DG. (1st Floor))FY-25-26
222Cost of dedicated Operation and AMC Support for RSA SIEM for WBSDC through L2 Level EngineerFY-22-23
223Cost of dedicated Operation and AMC Support for RSA SIEM for WBSDC through L2 Level EngineerFY-23-24
224Cost of dedicated Operation and AMC Support for RSA SIEM for WBSDC through L2 Level EngineerFY-24-25
225Cost of dedicated Operation and AMC Support for RSA SIEM for WBSDC through L2 Level EngineerFY-25-26
226AMC/Support Cost for UPS batteries for 2 years (4th & 5th years), post initial 3 years warranty period for 204 cells of 2v/357ahFY-23-24
227AMC/Support Cost for UPS batteries for 2 years (4th & 5th years), post initial 3 years warranty period for 204 cells of 2v/357ahFY-24-25
228AMC/Support Cost for UPS batteries for 2 years (4th & 5th years), post initial 3 years warranty period for 204 cells of 2v/357ahFY-25-26
229Professional Support Services for one Database and one System Administrators with effect from 1.4.2022FY-22-23
230Professional Support Services for two Database and two System Administrators with effect from 1.4.2022FY-23-24
231Professional Support Services for three Database and three System Administrators with effect from 1.4.2022FY-24-25
232Professional Support Services for three Database and three System Administrators with effect from 1.4.2022FY-25-26
233Vodafone/other ISP 1000 Mbps ILL for WBSDC for 1 year upto 31.03.2022FY-21-22
234Vodafone/other ISP 1000 Mbps ILL for WBSDC for 1 year upto 31.03.2023FY-22-23
235Vodafone/other ISP 1000 Mbps ILL for WBSDC for 1 year upto 31.03.2024FY-23-24
236Vodafone/other ISP 1000 Mbps ILL for WBSDC for 1 year upto 31.03.2025FY-24-25
237Vodafone/other ISP 1000 Mbps ILL for WBSDC for 1 year upto 31.03.2026FY-25-26
238AMC & UPGRADE of old SDC cloud servers (4)FY-22-23
239AMC & UPGRADE of old SDC cloud servers (4)FY-23-24
240AMC & UPGRADE (30 to 75TB) of Dell VTL of old SDC cloud system period from 1/4/2022 to 31/3/2023FY-22-23
241AMC of upgraded Dell VTL of old SDC cloud system period from 1/4/2023 to 31/3/2024FY-23-24
242AMC & UPGRADE (75 to 100TB) of Dell VTL of old SDC cloud system period from 1/4/2024 to 31/3/2025FY-24-25
243AMC of upgraded Dell VTL of old SDC cloud system period from 1/4/2025 to 31/3/2026FY-25-26
244AMC / ATS & UPGRADE (from 40 to 60TB) of Commvault Backup System from 2023FY-23-24
245AMC / ATS (60TB) of Commvault Backup System from 2023FY-24-25
246AMC / ATS (60TB) of Commvault Backup System from 2023FY-25-26
247AMC of WBSDC new cloud (blade) servers - lot oneFY-23-24
248AMC of WBSDC new cloud (blade) servers - lot oneFY-24-25
249AMC of WBSDC new cloud (blade) servers - lot oneFY-25-26
250AMC of Netapp SAN storage (430 TB) for the period from 2023FY-23-24
251AMC of Netapp SAN storage (430 TB) for the period from 2023FY-24-25
252AMC of Netapp SAN storage (430 TB) for the period from 2023FY-25-26
253AMC of WBSDC new network (SDN) infrastructureFY-23-24
254AMC of WBSDC new network (SDN) infrastructureFY-24-25
255AMC of WBSDC new network (SDN) infrastructureFY-25-26
256AMC & UPGRADE of RedhatOpenstack Cloud Software License SA for FY-23-24
257AMC & UPGRADE of RedhatOpenstack Cloud Software License SA for FY-24-25
258AMC & UPGRADE of RedhatOpenstack Cloud Software License SA for FY-25-26
259Renewal of RSA Software Product Licenses with OEM support for 1 yearFY-22-23
260Renewal of RSA Software Product Licenses with OEM support for 1 yearFY-23-24
261Renewal of RSA Software Product Licenses with OEM support for 1 yearFY-24-25
262Renewal of RSA Software Product Licenses with OEM support for 1 yearFY-25-26
263SOAR (Security Orchestration Automation Response) Software License RenewalFY-24-25
264SOAR (Security Orchestration Automation Response) Software License RenewalFY-25-26
265DDOS 10Gbps additional 1 Years subscriptionFY-24-25
266DDOS 10Gbps additional 1 Years subscriptionFY-25-26
267DC Augmentation - Installation, Commissioning & System Integration Charges
268Deep Security Enterprise Software License - additional 150 VMs for 2 years during FY-21-22
269Deep Security Enterprise Software License - additional 50 VMs for 1 years & License renewals for all existing licenses during FY-22-23
270Deep Security Enterprise Software License - additional 50 VMs for 1 years & License renewals for all existing licenses for yearFY-23-24
271Deep Security Enterprise Software License - additional 50 VMs for 1 years & License renewals for all existing licenses for yearFY-24-25
272Deep Security Enterprise Software License - additional 50 VMs for 1 years & License renewals for all existing licenses for yearFY-25-26
273EDB Postgres Enterprise License CPU Core support renewal / upgrade - Production Support (including Replica DB servers)FY-21-22
274EDB Postgres Enterprise License CPU Core support renewal / upgrade - Production Support (including Replica DB servers)FY-22-23
275EDB Postgres Enterprise License CPU Core support renewal / upgrade - Production Support (including Replica DB servers)FY-23-24
276EDB Postgres Enterprise License CPU Core support renewal / upgrade - Production Support (including Replica DB servers)FY-24-25
277EDB Postgres Enterprise License CPU Core support renewal / upgrade - Production Support (including Replica DB servers)FY-25-26
278VMware vCloud Suite Subscriptionper CPU 20 CPUs Commitment Plan - 12 month Prepaid with supportFY-22-23
279VMware vCloud Suite Subscriptionper CPU 20 CPUs Commitment Plan - 12 month Prepaid with supportFY-23-24
280VMware vCloud Suite Subscriptionper CPU 20 CPUs Commitment Plan - 12 month Prepaid with supportFY-24-25
281VMware vCloud Suite Subscriptionper CPU 20 CPUs Commitment Plan - 12 month Prepaid with supportFY-25-26
282DC-DR LC & ILL ARC for DR SiteFY-22-23
283DC-DR LC & ILL ARC for DR SiteFY-23-24
284DC-DR LC & ILL ARC for DR SiteFY-24-25
285DC-DR LC & ILL ARC for DR SiteFY-25-26
286Capacitor Bank change of old UPSFY-21-22
287Capacitor Bank change of old UPSFY-24-25
288Electrical Earth Pit Repair / ReconstructionFY-22-23
289DG Repair / Replacement due to aging / obsolescenceFY-22-23
290DG Repair / Replacement due to aging / obsolescenceFY-24-25
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail