Tourism Department has published Providing Illumination Facility To Newly Constructed Arched Structure By Way Of Facade Lighting And Balance Electric Works Of Abolution Block At Jamai Masjid Srinagar. Providing Illumination Facility To Newly Constructed Arched Structure By Way Of Facade . Submission Date for this Tender is 13-12-2021. Electrification Work Tenders in SRINAGAR Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply installation testing and commissioningof 15 watt outdoor type decorative UP-down Luminaire with wall surface mounting using COB LED as light source. Preferred make: Philips/ Havell/ Crompton |
2 | Supply, installation, testing and commissioning of100 Watt ( system lumen 14000 lumens, wide beam ) Energy saving, environment friendlyHighbay LED IP65 luminaire Aluminum alloy pressure die casted housing with Buit In, electronic driver with APFC, lower THD, Open Circuit Protection, Surge Voltage Protection upto 10 kV with Built In SPD & other safety test as per IS 15885 Part-2/ Sec 13.the steel chain of suitable length is to be provided for its suspension.Preferred make: Philips/ Havell/ Crompton |
3 | Providing and fitting ofM.S. junction box by making adequate space in the brick work with suitable size clamp.The junction box shall be fitted with 4 pole 63 amp backelite connectorand 6-10 amp MCB 1 No. schinider/Legrandmake. Also asuitable clamp to be provided with junction box for proper fixing of junction box. |
4 | Providing of service connection and earthings to luminaire from the junction boxin 1.5 mmPVC insulated, multicore copper wire . |
5 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting of road / concrete,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench with cement concrete but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
6 | S/L , testing and commissioning of PVC alluminium armoured/unarmoured cable1100 volt grade Al. cable Havell/Eq. standardmake a) 10 sq.mm 2 core unarmoured |
7 | b) 10 sq.mm 4 core unarmoured |
8 | c) 35 sq. mm 4 core ( armoured) |
9 | Supply installation testing and comm. Ofmain control pannel, outdoor type ,double door( 4"x3"x1")sheet steel16 SWG powder coated phosphatised fitted with following accessories Legrand/Havells make MCB"S ,and shall have angle iron stand to be grouted in the cement concrete. |
10 | a) 63 amp TPNMCB 2 No. Legrand/L&T/Schinidermake |
11 | b) 200 amp 4 strip bus 1 No., A/V meter, indicator |
12 | c)space for 12 way MCB"s |
13 | d) Astronomical timer with suitable contactor |
14 | e) 160 Amp TPN MCCB 36 K Legrand/L&T/Schinidermake |
15 | S/I testing and comm. Of three phase 20 KVA 50HZ oil cooled(Transformeroil is to be provided with stabilizer conforming to IS 335,IEC296)) unbalanced type servo voltage stabilizer(A.E / Cosco/ Electricfield make) having an inputvoltage ranging from 156V to 415 V ( phase to phase)and balanced output voltage of 415V, +/- 1%.( Test certificate to be provided by the manufacturer) The unit incorporate |
16 | a) 0-500V moving iron type voltmeter with selector switch. |
17 | b) A three phase change over switch to read voltage on incoming and output side |
18 | c) indicating lights 6 No two numbers for each of the motorised units, one for lower limit and other for higher limit. |
19 | d) six push button control for movement operation of three motorised dimmer units two for each unit i.e one for raise operation and one for lower operation under the conditions of adjustment of auto/mannual selector switch (DPDT) |
20 | e) Single phase Preventer ( contactor Switch 200 amp) Legrand make. |
21 | f) six potential meter resistance with lock meter two for each phase control, one for sensitivity and other for level control. |
22 | g) two sets of indication lamps three numbers each to indicate output and input indication |
23 | h) 20 % over load bearing capacity for one hour. |
24 | P/F of sheet steel Kiosk suitable to houseservo stabilizer of following capacities fabricated out of 16 SWG M.S sheet having front door with locking arrangements and duly powder coated. |
25 | a) 20 KVA |
26 | Providing and fixing of Al.thimble 10 mm sq. to 35 mm sq.including its crimping , taping etc. |
27 | Supply fixing testing and comm. Of MCB"sLegrand /Schenieder/Hager/Crabtreemake. |
28 | a) 40-63 amp. DP MCB. |
29 | b) 16-32 amp. SP MCB |
30 | c) 40-63 amp TPN MCB |
31 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Anchor/ Eq. make), single core cable in surface/ recessed medium class PVC conduit as required. |
32 | (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
33 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
34 | (c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
35 | ( C ) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
36 | Supplying and fixing of following sizes of medium class PVCpipe along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.the job includes cutting the brick work/ concrete for laying of PVC pipe and finishing the same with chuna surkhee/ concrete where required. |
37 | 25mm |
38 | 50 mm |
39 | Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block. |
40 | Carrying out foundation of PCC type,cement concrete to be carried in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)in foundation of Servo stabilizer and other allied works etc including form work etc as required the job also includes supply and carriageetc of the requsite material upto thesite. |
41 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Anchor/ Eq. make) single core cable in surface / recessed medium class PVC conduit ( Anchor/ Alba make), with modular switch ( Anchor roma urban/ Eq. make), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
42 | Supplying and fixing of following sizes of medium class PVC conduit ( Anchor/ Alba/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
43 | 25mm |
44 | Supply and fixing of 6/16 amp/230 V AC 6 pin sockets with cover plateAnchor Roma urban/SSK NV/ Eq. make. |
45 | Supply and fixing of 16/20 amp/230 V AC one way switch with cover plateAnchor Roma urban/SSK NV/ Eq. make. |
46 | Supply and fixing of 6 amp/230 V AC 5 pin socketswith cover plate Anchor Roma urban/SSK NV/ Eq. make. |
47 | S/F testing and comm. Of recessed/ surface mounted ceiling 12 WattLED down lighters making adequate space in the ceiling ( commercial series of approved make) philips / Havell/Crompton make of eq. standard. |
48 | S/F testing and comm. Of recessed/ surface mounted ceiling 7 WattLED down lighters making adequate space in the ceiling ( commercial series of approved make) philips / Havell/Crompton make of eq. standard. |
49 | Supply installation testing and comm. of distribution Board 16way double door Horizontal Distribution Board Legrand/ Eq. make. |
50 | Supply,Installation of 9" sweep exhaust fan Shutter type of havell /Bajaj/Crompton make.in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
51 | Supply installation testing and comm. Of 1200 mm ceiling fan ModeloysterMetallicHavell make/ Bajaj/Crompton(Flavia) of eq. standard( strictly as per approved sample) |
52 | Supply installation testing and comm. Of2"x3"x1" control pannel outdoor typesheet steel 16SWGpowder coated phosphatised having angle iron stand fitted with following accessories to be grouted in the cement concrete, complete job |
53 | a) 200 amp 4 strip bus 1 No. |
54 | b) A/V meters set/indicators |
55 | c) space for 12 way MCB"s |
56 | d) 100 TPN MCCB Legrand make 1 No. |
57 | Providing of earthing using G.I plateearthingand G.I strip risers along with associated material as per I.S standards |
58 | Supply installation testing and comm.of50 lit. geyserHindware/venus/Recold make includingmaking good the damage, C.Pconnection, geyser boltsetc. plumbing and civil woks as required. |