Indian Institute Of Technology-IITB has published Zonal Contract For Air Conditioning Works Related To Ac Plant Ahu Fcu Units And Any Other Associated Works In Zone Vii Viii And Fume Exhaust System In Hostel Area. Submission Date for this Tender is 17-12-2021. Air Conditioner Tenders in IIT Kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply, laying /fixing, testing and commissioning of MS Heavy "C" class pipe ( IS :1239 up 150mm & IS :3589 above 150mm ) of following sizes for chilled/ condenser water piping on surface / underground (including fabrication of bends / elbows, tees, reducers, sockets, unions etc) with wooden / PUf block, masonry support/MS angle-clamp two coats primer/ enamel paint, vibration isolatorsand fittings as per standard specification complete as required. |
2 | 25 mm |
3 | 32 mm |
4 | 40 mm |
5 | 50 mm |
6 | 65 mm |
7 | 80 mm |
8 | 100 mm |
9 | 125 mm |
10 | 150 mm |
11 | 200 mm (6.35mm th) |
12 | 250 mm (6.35mm th) |
13 | 300 mm (6.35mm th) |
14 | Laying /fixing, testing and commissioning of MS Heavy "C" class pipe ( IS :1239 up 150mm & IS :3589 above 150mm) of following sizes for chilled/ condenser water piping on surface / underground ( including fabrication of bends / elbows, tees, reducers, sockets, unions etc) with wooden / PUf block, masonry support / MS angle-clamp two coats primer/ enamel paint, vibration isolatorsand fittings as per standard specification complete as required. (Pipe will be provided by the institute free of cost). |
15 | 25 mm |
16 | 32 mm |
17 | 40 mm |
18 | 50 mm |
19 | 65 mm |
20 | 80 mm |
21 | 100 mm |
22 | 125 mm |
23 | 150 mm |
24 | 200 mm6.35mm thick |
25 | 250 mm6.35mm thick |
26 | 300 mm6.35mm thick |
27 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall. |
28 | 20 mm |
29 | 25 mm |
30 | 32 mm |
31 | 40 mm |
32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
33 | 20 mm nominal outer dia Pipes |
34 | 25 mm nominal outer dia Pipes |
35 | 32 mm nominal outer dia Pipes |
36 | 40 mm nominal outer dia Pipes |
37 | Providing, fixing, testing & commissioning of 2-way Motorized valve with actuator in FCU of following Capacity including dismantling of old if any etc. complete as reqd. |
38 | 20 mm |
39 | 25 mm |
40 | SITC of Butterfly valves CI body with SS DiscNitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water with hand lever operated including nut, bolt, flanges, gasket and insulation of valveas kind of existing pipe etc. complete as reqd. |
41 | 40 mm |
42 | 50 mm |
43 | 65 mm |
44 | 80 mm |
45 | 100 mm |
46 | 125 mm |
47 | 150 mm |
48 | 200 mm |
49 | 250 mm |
50 | 300 mm |
51 | Supplying, fixing, testing and commissioningBalancing Valve with built in measuring facilitywith C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. (A-DSR 18) |
52 | 40 mm |
53 | 50 mm |
54 | Supplying & fixing insulation on existing MS "C" class pipe over exposed surface/underground of following sizes with 50 mm thick fire retardant thermocole ( polystrene) moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with500g polythene faced hessain cloth, wiremesh, sand-cement plaster &enamel painting two or more coat to give even shade after applying one coat of ordinary paint etc complete as required. |
55 | 25 mm |
56 | 32 mm |
57 | 40 mm |
58 | 50 mm |
59 | 65 mm |
60 | 80 mm |
61 | 100 mm |
62 | 125 mm |
63 | 150 mm |
64 | 200 mm |
65 | 250 mm |
66 | 300 mm |
67 | Supplying, laying/ fixing of 30 mm thickness polyurethane foam (PUF) insulation with fire retardant quality on existing pipe of following sizeswith ,moulded pipe sectionof density of 32±2 kg/m³ with adhesive CPRX/ bitumen, tagged with GI wire, joints wrapping with PVC tape and peripheral wrapping the insulation with tarfelt etc.complete as reqd. |
68 | 25 mm |
69 | 32 mm |
70 | 40 mm |
71 | 50 mm |
72 | 65 mm |
73 | 80 mm |
74 | 100 mm |
75 | Providing & fixing of thermal insulationwith aluminium foil faced nitrile rubber Class "O" sheet of following thicknesson existing surface of duct with dentrite/adhesive etc.The joints shall be sealed with 50 mm wide andselfadhesivePVC/Aluminumtape complete as required. |
76 | 6 mm |
77 | 9 mm |
78 | 13 mm |
79 | 16 mm |
80 | 19 mm |
81 | 25 mm |
82 | Providing & fixing of thermal insulationwithout aluminium foil faced nitrile rubber Class "O" sheet of following thicknesson existing surface of duct with dentrite/adhesive etc.The joints shall be sealed with 50 mm wide andselfadhesivePVC/Aluminumtape complete as required. |
83 | 6 mm |
84 | 9 mm |
85 | 13 mm |
86 | 16 mm |
87 | 19 mm |
88 | 25 mm |
89 | Supplying & fixing, insulation on existingpipe overhead offollowing sizeswith 25 mm thick Aluminium faced nitrial rubber / XLPE foam pipe section fixing with dentride and tightening of insulation sectionPVC tape to be wrapped all around the joints. of insulation etc complete as required. |
90 | 25 mm |
91 | 32 mm |
92 | 40 mm |
93 | 50 mm |
94 | Supplying & fixing, insulation on existingpipe overhead/underground offollowing sizeswithout 25 mm thick Aluminium faced nitrilel rubber / XLPE foam pipe section fixing with dentride and tightening of insulation sectionPVC tape to be wrapped all around the joints. of insulation etc complete as required. |
95 | 25 mm |
96 | 32 mm |
97 | 40 mm |
98 | 50 mm |
99 | Cutting and dismantling of damaged and defective MS"C" class pipe of size as mentioned below ( exposed over the surface/ underground ) i/c shifting the same to sectional store or desired location i/c cartage. |
100 | 20 mm to 100 mm dia. |
101 | 125 mm to 200 mm dia |
102 | 250 mm to 400 mm dia |
103 | Cutting & dismantling of damaged and defective insulation, removing the thermocole , nitrile, PUF insulation or clading from chilled water MS pipe line of size mentioned belowincluding hessian cloth, wire mesh, sand, cement, plaster, cleaning of pipe and shiftingthe waste material outside the permises of I.I.T. K. campus or desired location as reqd.. |
104 | 20 mm to 100 mm dia. |
105 | 125 mm to 200 mm dia |
106 | 250 mm to 400 mm dia |
107 | Cutting & dismantling of condenser / chilled water pipe line for drain out the water from supply and return pipe line and making good i/c re-filling of water inpipe line size from 20 mm to 400 mm dia including testing & commissioning etc as required. |
108 | 20 mm to 100 mm dia. |
109 | 125 mm to 200 mm dia |
110 | 250 mm to 400 mm dia |
111 | Rewinding of burnt three phase electric motor (AHU/Pump/cooling tower Motor/ fume exhaust / air washer) including dismantaling & re-fixing from position, the supply of copper winding wire (Milan make ) old burnt wire shall be retained by the contactor, varnishing using Dr. Beack"s varnish, testing, assembling and commissioning as required. |
112 | upto 1.9 HP |
113 | 2 to 4.5 HP |
114 | 5 to 10 HP |
115 | 12 to 19 HP |
116 | 20 to 30 HP |
117 | Drain out the water from supply & return pipe line andmaking good i/c re-filling of water inpipe line ,testing & commissioning complete as required. |
118 | 20 mm to 100 mm dia. |
119 | 125 mm to 400 mm dia |
120 | Complete Overhauling, descaling ,oiling and greasing of any type valve including dismantling, refitting in position with nut,bolts and washer etc. complete as requird. |
121 | Size up to 80 mm |
122 | Size 100 mm to200mm |
123 | Size 250 mm to 350 mm |
124 | Providing and fixing aluminium clading made of 26 swg thick aluminium sheet i/c band, reducer, tee, dead end etc complete as required. |
125 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. |
126 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with lowers but withoutaluminium volume control dampers as reqd |
127 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. |
128 | Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. |
129 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. |
130 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
131 | 1 x 1.5 sq. mm |
132 | 2 x 1.5 sq. mm |
133 | 3 x 1.5 sq. mm |
134 | 2 x 4 sq. mm |
135 | 3 x 4 sq. mm |
136 | 4 x 4 sq. mm |
137 | 2 x 6 sq. mm |
138 | 3 x 6 sq. mm |
139 | 4 x 6 sq. mm |
140 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required |
141 | 20 mm |
142 | 25 mm |
143 | 32 mm |
144 | 40 mm |
145 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
146 | 20 mm |
147 | 25 mm |
148 | 32 mm |
149 | 40 mm |
150 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
151 | 100 mm X 100 mm X 60 mm deep |
152 | 180 mm X 100 mm X 60 mm deep |
153 | 200 mm X 150 mm X 60 mm deep |
154 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. |
155 | 5/6 A switch |
156 | 2 way 5/6 A switch |
157 | 15/16 A switch |
158 | 3 pin 5/6 A socket outlet |
159 | 6 pin 15/16 A socket outlet |
160 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
161 | Single pole |
162 | Single pole and neutral |
163 | Triple pole |
164 | Triple pole and neutral |
165 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade , Upto 35 sq. mm |
166 | direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required |
167 | in pipe |
168 | In open duct |
169 | on surface with MS clamp |
170 | Supplying fixing connectingcommissioning and testing of the following luminaries light fixtures complete with all accessories and with clamp as required. |
171 | LED tubelightfitting ( 1 X 18/20 watt LED) surface mount |
172 | LED tubelightfitting ( 2 X 18/20 watt LED) surface mount |
173 | 48 watt LED streetlight make of pressure Die aluminum fixture ( suitable for outdoor installation) |
174 | Providing & fixing of three phase DOL startar Suitable for following size motor, 415 Volts, with single phase preventer, wideband coil, ammeter, ON-OFF indicatoretc. complete as required. |
175 | Upto 5 H.P |
176 | 7.5 H.P |
177 | Providing and fixing of Single Phase Plug topISI Marked forAC (FCU) unitetc i/c dismentling old plug top if any complete as required.(Make:- Anchor or Equvilant) |
178 | 3 pin- 6 Amp. |
179 | 3 pin- 16 Amp. |
180 | Providing,laying & fixing of rainforced fiber flexible/softPVC pipe of size given below etc. complete as reqd. |
181 | 20 mm |
182 | 25 mm |
183 | 32 mm |
184 | Supply & fixing of copper piping 5/8" or 6/8" with 19 mm thick Class "O" Nitrile insulation on surface / recessed with flair nut, clamps etc.complete as reqd. |
185 | Dismantling and overhauling ofany type strainers of sizesmentioned belowincluding cleaning, refixing and replacement of defective strainer mesh (SS) with new one, gasket,nut, bolts, painting, welding work as required. |
186 | up to 80 mm |
187 | 100 mm to 200 mm |
188 | 250 mm to 350 mm |
189 | Servicing, cleaning, discaling, overhauling, lubricating, testing and re-commissioning of AHU floor mounted/ ceiling suspended/ LLD blower cooling coils & filtersincluding with proper chemicals, soap etc and neutralizing the same complete asrequired |
190 | AHU up to 2500 CFM,4-6 R cooling coil. |
191 | AHU 2501 CFM to 6000CFM/4-6 R cooling coil. |
192 | AHU 6001 CFM to 12000 CFM/LLD blower 3, 4-6 R cooling coil. |
193 | AHU 12001 CFM and above /LLD blower 3.5, 4-6 R cooling coil |
194 | Dismantling of any type of AHU blower / LLD blower shaft, remetaling, straightening machining, matching with bearing size, reassembling, dynamic balancing, along with blower testing and commissioning at site including cartage asper siterequirement . |
195 | Up to 8000 CFM |
196 | 8001 to 12000 CFM |
197 | Above 12000 CFM |
198 | Dismantling & removing of Air handling unit (Floor/ceiling type) with associated parts and disconnecting from CHW line & ducting etc. complete as reqd. |
199 | AHU up to 2500 CFM,4-6 R cooling coil. |
200 | AHU 2501 CFM to 6000CFM/4-6 R cooling coil. |
201 | AHU 6001 CFM to 12000 CFM/LLD blower 3, 4-6 R cooling coil. |
202 | AHU 12001 CFM and above /LLDblower 3.5, 4-6 R cooling coil |
203 | Installation of Air Handling unit (floor/ceiling type) with connecting from CHW line & ducting balancing of shaft fixing of blower, pulley and other associated parts etc. complete as reqd. |
204 | AHU up to 2500 CFM,4-6 R cooling coil. |
205 | AHU 2501 CFM to 6000CFM/4-6 R cooling coil. |
206 | AHU 6001 CFM to 12000 CFM/LLD blower 3, 4-6 R cooling coil. |
207 | AHU 12001 CFM and above /LLDblower 3.5, 4-6 R cooling coil |
208 | Dismantling and removing of existing old ducts of any size, i/c removing of hangers , flanges , damper, diffuser, grill and depositing in the sectional store complete as reqd. |
209 | Dismantling & re-fixing of same (Modified) existing old ducts of any size i/c removing of hangers , flanges , damper, diffuser, grillcomplete as reqd.. |
210 | Supply,installation, balancing and commissioning offabricated at siteGSSsheet metal rectangular/roundducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
211 | 0.63 mm (24 G) thick |
212 | 0.80 mm (22 G) thick |
213 | Supplying and Fixing of " V " belts size as mentioned below of approved make. |
214 | A-21 |
215 | A-23 |
216 | A-25 |
217 | A-26 |
218 | A-28 |
219 | A-29 |
220 | A-30 |
221 | A-31 |
222 | A-32 |
223 | A-33 |
224 | A-35 |
225 | A-37 |
226 | A-38 |
227 | A-40 |
228 | A-47 |
229 | A-48 |
230 | A-51 |
231 | A-53 |
232 | A-54 |
233 | A-56 |
234 | A-59 |
235 | A-62 |
236 | A-63 |
237 | A-65 |
238 | A-66 |
239 | A-73 |
240 | A-82 |
241 | A-83 |
242 | A-90 |
243 | Supplying and Fixing of " V " belts size as mentioned below of approved make. |
244 | B-44 |
245 | B-45 |
246 | B-52 |
247 | B-58 |
248 | B-62 |
249 | B-65 |
250 | B-68 |
251 | B-69 |
252 | B-72 |
253 | B-73 |
254 | B-74 |
255 | B-75 |
256 | B-76 |
257 | B-78 |
258 | B-79 |
259 | B-80 |
260 | B-81 |
261 | B-82 |
262 | B-83 |
263 | B-84 |
264 | B-85 |
265 | B-86 |
266 | B-87 |
267 | B-89 |
268 | B-90 |
269 | B-93 |
270 | B-97 |
271 | B-102 |
272 | B-108 |
273 | B-128 |
274 | B-130 |
275 | B-132 |
276 | Supplying and fixing following size ball bearing NBC make complete in all respect including dismantling the existing defective bearing and depositing the same sectional store. |
277 | 6205 (2RS1/C3) |
278 | 6206 (2RS1/C4) |
279 | 6305 (2RS1/C3) |
280 | 6306 (2RS1/C3) |
281 | 6307 (2RS1/C3) |
282 | 6308 (21/C3) |
283 | 6309 (2RS1/C3) |
284 | 6310 (2RS1/C3) |
285 | 6312 (2RS1/C3) |
286 | LE-20 |
287 | LE-30 |
288 | 6205 ZZ |
289 | 6206 ZZ |
290 | Supplying, fixing, testing and commissioning ofCI body and S.S Screen type Y-strainer of following sizewith compatible to MSpipei/c all necessary support /hangers, including old dismantling if any complete as reqd. |
291 | 40 mm |
292 | 50 mm |
293 | 65 mm |
294 | 80 mm |
295 | 100 mm |
296 | Supplying and fixing of syphon with ballvalve complete set of following size. |
297 | Size 3/8" |
298 | Size 1/2" |
299 | Supplying and fixing of MS Nipple of size of following size length etc. complete as reqd. |
300 | Size 15 mm up to 2" length |
301 | Size 20 mm up to 2" length |
302 | Size 25 mm up to 2" length |
303 | Size 32 mm up to 2" length |
304 | Supplying and fixing of MS bend of following size complete as required. |
305 | Size 15 mm up to 2" length |
306 | Size 20 mm up to 2" length |
307 | Size 25 mm up to 2" length |
308 | Size 32 mm up to 2" length |
309 | Supplying and installation of Plumber block bearing including dismantling of existing bearing as per specification. |
310 | UCP 206 |
311 | UCP 207 |
312 | UCP 208 |
313 | UCP 209 |
314 | UCP 210 |
315 | UC-207 NTN |
316 | P & F " Vibration Isolation Pad of size as mentioned below ofapproved make i/c dismantling old one if any complete as required. |
317 | 4"x 4" |
318 | 6"x 6" |
319 | Providing and fixing of MS sheet cover 16 SWG on existing chamber of suitable size with angle iron frame size 35 x 35 x 5 mm,having MS handleincluding cutting, grouting, welding and paintingcomplete as required. |
320 | size for1.5 sqm |
321 | size for 1.6 to 2.5 sqm |
322 | Making a brick masonry chambers 1.50(L) x 1.00(W) x 1.00 mtr deep in side with first class designation brick work in cement mortar 1:6 coarse sand with frame of angle iron 35mmx35mm x6mm with top cover 2mm thick ms sheet fixed with top of the slab with handle i/c two coat painting complete as required. |
323 | Making a brick masonry chambers 1.0(L) x 1.0(W) x 1.0 mtr deep in side with first class designation brick work in cement mortar 1:6 coarse sand with frame of angle iron 35mmx35mm x6mm with top cover 2mm thick ms sheet fixed with top of the slab with handle i/c two coat painting complete as required. |
324 | Supply & fixing of fire retardant double cloth canvass made (up to 300 mm vide) with heavy clothes and suitable frame with G.I washer, nuts & bolts in suitable size. i/c jointing both sides with suitable gaskets complete as reqd. |
325 | Supply & fixing of fire retardant single layer canvass made (up to 300 mm vide) with heavy clothes and suitable frame with G.I washer, nuts & bolts in suitable size. i/c jointing both sides with suitable gaskets complete as reqd. |
326 | Applying one coat of water thinnable cement / wall exterior primer of approved brand and manufacture on wall surface : 13.43.1 water thinnable cement primer |
327 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on new work. |
328 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) |
329 | Demolishing brick work i/c stacking of serviceable mat. with in 50 mtrs lead. In cement mortar.(15.7.4) dsr code |
330 | Pointing on brick flooring with cement mortar 1:3 ( 1 cement : 3 fine sand ) Ruled pointing.(13.31.1) dsr code |
331 | Brick on edge flooring with bricks of class designation 75 i/c cement slurry etc complete in cement mortar with F.P.S bricks 1:6 (1 cement:6 coarse sand.)(11.1.2) dsr |
332 | Cutting road and making good the same i/c supply of extra quantities of materials i.e. egg., mooram screening, red bajri and labour req.Bituminious portion.(16.13.1) dsr |
333 | Excavating trenches of requiredwith for pipes, cables etc including excavation for sockets, dressings of sides, bottoms, depth up to 1.5 mtr including getting out the excavated ramming of soil, and then returning the soil as required in layers not excavated. |
334 | Pipes, cables, etc exceeding 80 mm dia.but not exceeding 300 mm dia. |
335 | Pipes, cables, etc exceeding 300 mm dia.but not exceeding 600 mm dia. |
336 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc.complete as per directions and approval of Engineer-in-charge. |
337 | Servicing of AHU/TFA/Pump/cooling tower motor of following capacity including opening from position, dismantling fan hub/pump coupling/Pully, cleaning, re-varnishing, epoxy coating, heating, assembly fitting alignment & commissioning ofmotor etc. complete as reqd. |
338 | Up to 5 HP motor |
339 | 5.1 to 12.5 HP motor |
340 | SITC of Fan Coil Unit (Hi-Wall), The unit shall be complete with insulated enclosure, comprising of blower, 2/3 speed motor with fan speed controller, 2/3 row copper coil section, washable filter section, 2 way motorized valve with actuator, remote controller (Thermostate) andbrass flair fitting for copper pipe connection, i/c all necessary support /hangers, vibration isolators etc. complete as reqd. |
341 | 1.5 TR |
342 | 2.0 TR |
343 | 2.5 TR |
344 | SITC of modular type Fan Coil Unit (floor/wall-mounted) , The unit shall be complete with grills, insulated enclosure, drain tray, comprising of blower, 2/3 speed motor with fan speed controller, 2/3 row copper coil section, washable filter section, 2 way motorised valve with actuator, andbrass flair fitting for copper pipe connection, i/c all necessary support /hangers, vibration isolators etc. complete as reqd. |
345 | 1.5 TR |
346 | 2.0 TR |
347 | 2.25 TR |
348 | Providing and fixing Digital type thermostat for FCUs/AHUs commissioning i/cdismantling old if anyetc. complete as reqd. |
349 | Providing & fixing ofBrass ball valve with flare-nut of following sizewith compatible to proportioning Copper/MSpipei/c all necessary accessories, support /hangers, including old dismantling if any complete as reqd. |
350 | 20 mm |
351 | 25 mm |
352 | Providing & fixing ofBrass Ball valve with Y-strainer i/c flare-nut of following sizewith compatible to proportioning Copper/MSpipei/c all necessary support /hangers & dismantling old if any complete as reqd. |
353 | 20 mm |
354 | 25 mm |
355 | Providing & fixing ofBrass ball valve of following sizewith compatible to proportioning Copper/MSpipei/c all necessary accessories, support /hangers, including old dismantling if any complete as reqd. |
356 | 20 mm |
357 | 25 mm |
358 | Providing & fixing ofSS ball valve of following sizewith compatible to proportioning Copper/MSpipei/c all necessary accessories, support /hangers, including old dismantling if any complete as reqd. |
359 | 20 mm |
360 | 25 mm |
361 | 32 mm |
362 | 40 mm |
363 | Providing & fixing in position the mercury in glass industrial type thermometers. |
364 | Providing and fixing in position the 0-150 PSIG industrial type pressure gauges with gun metal / brass petcock valves & MS nipple, socket etc complete as required |
365 | Providing & fixing ofBrass Air-Vent of following sizewith compatible Copper/MSpipei/c all necessary accessories & dismantling old if any complete as reqd. |
366 | 20 mm |
367 | 25 mm |
368 | Providing and fixing, testing & commissioningthe Capacitor of following capacity in the existing FCUi/c all necessary accessories & dismantling old if any complete as reqd. |
369 | 2.5 mfd |
370 | 4.0 mfd |
371 | Providing & fixing 20 Swg GI Drain tray with 9/13 mm nitrile/XLPE insulation of suitable size for FCU (1.5 to 3.5 TR) capacity i/c fabricating, cutting, moulding drain nozzle duly painted/epoxy coating & dismantling old if any, complete as reqd. |
372 | Providing and fixing remote control with PCB & Handset in fan coil units of following Capacity re-commissioning i/cdismantling old if anyetc. complete as reqd. |
373 | Up to 1.5 TR Capacity |
374 | 2.0 TR to 3.5 TR Capacity |
375 | Providing and fixing of Air-blower in fan coil units of following Capacity re-commissioning i/cdismantling old if anyetc. complete as reqd. |
376 | Up to 2 TR Capacity |
377 | 2.1 TR to 3.0 TR Capacity |
378 | Servicing,descaling,overhauling,testing and commissioning of FCU (wall/floor/ceiling mounted type) of following capacity including Dismantling , motor oiling, cleanig fans,filter,descaling cooling coil,valves and removing leakage, painting of rusted parts etc. as complete required. |
379 | Up to 2.0 TR Capacity |
380 | 2.1 TR to 3.5 TR Capacity |
381 | Rewinding of burnt single phase FCU fan motor of following capacitywith material(i.e.-copper wire, varnish and associated insulation material ) as per original design of standard manufacturer, including dismantling and refixing of motor with accessories in existingFCU along withconnecting , testing and commissioning as reqd. |
382 | Up to 2.0 TR Capacity |
383 | 2.1 TR to 3.5 TR Capacity |
384 | Dismantling and refixing of old grill and diffuser, VCD after cleaning as reqd. |
385 | Supply & fixing ofwashable nylon/synthetic/wooven fiber pre Air-filter with Al. frame etc complete of any size FCU complete as reqd. |
386 | Up to 2.0 TR Capacity |
387 | Above 2.0 TR to 3.5 TR Capacity |
388 | Dismantling of Fan coil unit of Hi-wall/wall/floor mounted or ceiling suspended type up to 3.5 TR capacity including filter and valves etc. Complete as required. |
389 | Installation, testing & commissioning of FCU (Hi-wall/Floor/Wall mounted or ceiling suspended type of following size at new location including fashner, hengers, supports etc. complete as reqd. (Labour with supports) |
390 | Up to 2.0 TR Capacity with accessories |
391 | 2.1 TR to 3.5 TR Capacitywith accessories |
392 | Installation, testing & commissioning of FCU (Hi-wall/Floor/Wall mounted or ceiling suspended type of following size at new location including fashner, hengers, supports etc. complete as reqd. (Labour without supports) |
393 | Up to 2.0 TR Capacity with accessories |
394 | 2.1 TR to 3.5 TR Capacitywith accessories |
395 | Servicing, Overhauling, oiling, greasing, & re-installation of FCUs fan motor of single phase as per original design with replacement of required materials including Dismantling & refixing of motor & accessories(Bush/Bearing)in existingFCU. complete as reqd. |
396 | Up to 3.5 TR Capacity fan motor |
397 | Supply and fixing of high carbon steel shaft approved make for fan motor of FCU of following capacity (length of shaft and rpm shall be as original i.c. old dismantling if any complete as reqd. |
398 | Up to 2.0 TR Capacity |
399 | Above 2.1 TR to 3.5 TR capacity |
400 | Removing & cleaning old paint and Repainting of FCU with acrylic emulsion paint of approved brand and manufacture to give an even shade complete as reqd. |
401 | Up to 2.0 TR Capacity |
402 | Above 2.1 TR to 3.5 TR capacity |
403 | Providing & fixing ofThermal protecting layer(double coat ) painting over exposed MS/copper pipe insulation outer surface with aapproved make chemical, shade and glass clothc as per standared specification compete as required. |
404 | 20 mm |
405 | 25 mm |
406 | 32 mm |
407 | 40 mm |
408 | 50 mm |
409 | 65 mm |
410 | 80 mm |
411 | Making wall opening upto 750 mm dia/Suitable in any type / thickof wall for pipe/duct etc and re-closing the opening with brick, sand, cementandplaster upto 20 mm i/c re-painting as per existing desigine/shape complete as required. |
412 | Supplying and fixingtaper-lock Pulleys including bush & key for AHU motor & blowers of following size including dismantling of defective pulleycomplete as required.( Make-Fenner/skf ) |
413 | Upto 71 x 2 SPA |
414 | 75/80/85 x 2 SPA |
415 | 90/95 x 2 SPA |
416 | 100 /106x 2 SPA |
417 | 112/118 x 2 SPA |
418 | 125 x 2 SPA |
419 | 132 x 2 SPA |
420 | 140 x 2 SPA |
421 | 150 x 2 SPA |
422 | 170 x 2 SPA |
423 | 190 x 2 SPA |
424 | 224 x 2 SPA |
425 | Dismantling of cooling tower for removing of existing fills and depositing at the required placeinstructed by Engineer Incharge complete as reqd (upto 150 TR CT) |
426 | Complete cleaning of FRP Basin & cooling tower by chemical etc complete as reqd. (upto 150 TR CT) |
427 | Providing & Fixing of PVC fillsof size 600x300x150mm as in existing cooling tower capable required capacity, Bell make, Model No.FD2018Scomplete as reqd. (Mihir Make or equivalent). |
428 | Providing & Fixing of PVC drift eleminator in existing cooling tower as per required capacity, Bell make, Model No. FD2018S complete as reqd. |
429 | Complete Re-assembling of cooling tower i/c testing & re- commissioning with painting on the rusted parts. (upto 150 TR CT) |
430 | Supply installation testing and commissioning of water strainer for softener distributionof make Ion Exchange or its equivalent. Including replacement of old and defective water strainer compleate as required. |
431 | Tube size 4 inch |
432 | Drainout water from spray pond, removing mud from sump, scrapping of dried silt by , brushing & cleaning floor/walls, repair of cracks and refilling water complete as reqd. |
433 | Servicing and cleaning of water spray nozzles i/c opening & re-filling i/c replacement of gasket etc. complete as reqd. |
434 | Dismantaling and Cleaning of FRP type twin cellwater softner i/cconnecting pipes and valves etc. |
435 | Re-assembling ofFRP type twin cellwater softner i/c testing & re- commissioning with necessary fittings. |
436 | Overhauling of centrifugal blowers of following size motor dismantling complete unit, checking and replacing damaged parts (extra cost will be paid against used new parts after submitted bill) cleaning with suitable powder & chemical, oiling, painting on reusted parts, greasing of bearing or movable parts, and reassembling, connecting testing and commissioning the complete unit as required. |
437 | Up to 3.0 HP motor direct coupled centrifugal SISW blower |
438 | Above 3.0 HP-5.0 HP motor belt driven centrifugal SISW blower |
439 | Above 5.0 HP- 7.5 HP motor belt driven centrifugal SISW blower |
440 | Above 7.5 HP -10.0 HP motot belt driven centrifugal SISW blower |
441 | Above 10 HP -12.5 HP motot belt driven centrifugal SISW blower |
442 | Dismantling of any type fume exhaust blower ( Belt Driven) shaft i/c remetalling, straightening machining, matching with bearing size, reassembling,l dynamic balancing, along with blowertesting and commissioning at site including cartage complete as required. |
443 | Upto 7.5 HPmotor capacityfume exhaust blower |
444 | Above 7.5 HP - 10 HPmotor capacity fume exhaust blower |
445 | Above 10 HPmotor capacity fume exhaust blower |
446 | Dismantling andrefixing of duct any gauge for cleaning and Cleaning & degreasing of kitchen/ canteen hoods, ducts (vertical & horizontal) i/c inside of blower and exhaust fan unit with blowerwith suitable powder & chemical and providing & reconnecting with G.I. washer, nut & bolts, 6 mm foam gaskets between joints etc. complete as reqd. |
447 | Providing & fixing of Anti vibration (cushy foot mount) mounting pad for bolwers etc. complete as reqd. |
448 | Providing & fixing of SS bird screen guard for fume exhaust hood with GI framecomplete as reqd. |