}

Widening Of Road Adjacent To Proposed Oxygen Building And Widening Of Road Adjacent To Proposed Oxygen Building And Construction Of One Retaining Wall Alongwith Extension Of Existing Cross Drain At District Hospital Complex , Tepania During The Year 2021, Udaipur-Tripura

Public Works Department-PWD has published Widening Of Road Adjacent To Proposed Oxygen Building And Widening Of Road Adjacent To Proposed Oxygen Building And Construction Of One Retaining Wall Alongwith Extension Of Existing Cross Drain At District Hospital Complex , Tepania During The Year 2021. Submission Date for this Tender is 20-12-2021. Road Work Tenders in Udaipur Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

30153483
Widening Of Road Adjacent To Proposed Oxygen Building And Widening Of Road Adjacent To Proposed Oxygen Building And Construction Of One Retaining Wall Alongwith Extension Of Existing Cross Drain At District Hospital Complex , Tepania During The Year 2021
Open Tender
Indian
Tripura
Udaipur
20-12-2021

Tender Details

Widening Of Road Adjacent To Proposed Oxygen Building And Widening Of Road Adjacent To Proposed Oxygen Building And Construction Of One Retaining Wall Alongwith Extension Of Existing Cross Drain At District Hospital Complex , Tepania During The Year 2021-2022

Key Value

Document Fees
INR 1000 /-
EMD
INR 24107.0 /-
Tender Value
INR 24.10 Lakhs /-

BOQ Items

Name of Work:Widening of road adjacent to proposed Oxygen building and construction of one retaining wall alongwith extension of existing cross drain at District Hospital complex , Tepania during the year 2021-2022.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan)including dressing of sides and ramming of bottoms, liftupto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a leadof 50 m. All Kinds of Soil.
2Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts includingspreading in horizontal layers, watering, grading torequired slope, ramming, consolidating and compactingeach layer by using plate compactor or by any suitablemethod complete.
3Providing and laying in position cement concrete ofspecified grade excluding the cost of centring andshuttering - All work upto Plinth Level. a)1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burntbrick aggregate 20 mm nominal size)
4a)1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burntbrick aggregate 20 mm nominal size)
5Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work upto Plinth Level. a) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
6Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing. a) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
7Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. a) Thermo-Mechanically Treated bars of grade Fe-500D or more
8Providing structural steel work riveted, bolted or weldedin built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all required.complete as
9Providing and fixing MS bolts including nuts and washers complete as per standard design:- a) Above 300 mm Length
10Providing structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required.
11Direction and place identification signs with size more than 0.90 sqm sign board. Providing and erecting direction and place identification retro-reflectorised sign as per irc; 67 made of encapsulated lens type reflective sheeting vide MoRD technical specification clause1701.2.3 fixed over aluminium sheeting , 2 mm thick with area 0.9 sqm
12Painting on concrete / Steel Surfaces with epoxy Painting twocoats including prime coat with epoxy paint of approved brand on concrete / steel surfaces after through cleaning of surface to give an even shade as per drawing and moRD technical specification clause 1701.
13Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. a) Thermo-Mechanically Treated bars of grade Fe-500D or more
14Half brick masonry work with first class bricks in foundation and plinth including cost of all materials as required complete:-a)In cement mortar 1:4 ( 1 cement : 4 fine sand ).
15First class brick work in foundation and plinth including cost of all materials as required complete.a)1:4(1 Cement:4 Fine sand).
1612 mm cement plaster of mix. a)Cement mortar 1:4 (1 cement : 4 fine sand)
17Neat Cement Punning
18Providing and fixing on wall face unplasticised rigid UPVC rain water pipes (working pressure 4 Kg/cm^2) conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion: a) Single Socketed Pipe 75 mm OD
19b) Single socketed Pipe
2060 mm thick factory made CC interlocking paver Block of M 30 Grade Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of sand, filling the joints with fine sand etc. all complete as per specification and approval/ direction of the Engineer-in-charge.
21Providing and laying filter media with jhamma brick aggregate as per specifications to a thickness not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall , return wall to the full height compacted to firm condition as per drawing and MoRT & H technical specification clause 2540.2.2
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail