Hansi Lab Strengthening Of Public Health Engineering Sub-Division Water Testing Laboratory Hansi Supplying Of Ph Meter, Conductivity Meter Tds Meter, Turbidity Meter, Benchtop , Distillation Plant, Hot Air Oven, Autoclave Vertical, Hygrometer, The, PHED HANSI-Haryana

Public Health Engineering Department-PHED has published Hansi Lab Strengthening Of Public Health Engineering Sub-Division Water Testing Laboratory Hansi Supplying Of Ph Meter, Conductivity Meter Tds Meter, Turbidity Meter, Benchtop , Distillation Plant, Hot Air Oven, Autoclave Vertical, Hygrometer, The. Submission Date for this Tender is 10-12-2021. Water Testing Accessories Tenders in PHED HANSI Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

30152779
Hansi Lab Strengthening Of Public Health Engineering Sub-Division Water Testing Laboratory Hansi Supplying Of Ph Meter, Conductivity Meter Tds Meter, Turbidity Meter, Benchtop , Distillation Plant, Hot Air Oven, Autoclave Vertical, Hygrometer, The
Open Tender
Indian
Haryana
PHED HANSI
10-12-2021

Tender Details

Hansi Lab Strengthening Of Public Health Engineering Sub-Division Water Testing Laboratory Hansi Supplying Of Ph Meter, Conductivity Meter Tds Meter, Turbidity Meter, Benchtop , Distillation Plant, Hot Air Oven, Autoclave Vertical, Hygrometer, Thermometer Simple And With Probe, Analytical Balance, Calibrated Weights, Dessicator, Bac

Key Value

Document Fees
INR 1000 /-
EMD
INR 18860.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : Hansi Lab :- Strengthening of Public Health Engineering Sub-Division Water Testing Laboratory Hansi"Supplying of pH meter, Conductivity meter /TDS METER, Turbidity meter (Benchtop)/ (Portable), Distillation plant, Hot Air Oven, Autoclave Vertical, Hygrometer, Thermometer simple and with probe, Analytical Balance, Calibrated Weights, Dessicator, Bacteriological incubator etc for Sub-Division Lab at Public Health Engineering Division Hansi and all other works contingent thereto
Sl. No. Item Description
1Works Details
2pH meter (with 5 years AMC) Lovibond, EUTECH, WTW, OAKTON, Metrohm pH Range -2.00 to 16.00 pH Resolution/Accuracy 0.01 pH/± 0.01 pH ORP Range ± 2000 mV Resolution/Accuracy 1.1 (± 199.9 mV) / 1 mV (beyond) 1.2 ± 0.2(± 199.9 mV) /± 2 mV (beyond) Temp.range 0.0 to 100.00 C (32.0 to 212.00 F) Resolution/Accuracy 0.1 0 C(0.1 0 F)/±0.3 ºC / ±0.5 ºF (0 to 70 ºC) ATC Yes (0 to 100 0 C) Buffer Options USA: pH 1.68, 4.01, 7.00, 10.01,12.45 NIST pH 1.68, 4.01, 6.86, 9.18 ,12.45 No.of pH Calibration Points 5points Built-in Electrode Arm Yes Memory 100data sets Electrode Included ECFC7252101B,single junction pH electrode. Temp.Probe Included LCD DISPLAY CUSTOM dual-display LCD(5.6X7.5cm) Power Requirements Included, 100 /240VAC SMPS Power Adapter with US/UK/EUR/Japan plug ,9V,6W, CENTRE
3Conductivity meter /TDS METER(with AMC for 5years) Lovibond, EUTECH, OAKTON, WTW, Hach, Metrohm Conductivity Range 0.01 to 200.0 mS/cm Resolution/Accuracy 0.01 / 0.1 ìS ; 1 / 0.01mS / 0.1 mS ±1 % full scale Resistivity Range 2.000 Ù to 20.0 MÙ Resolution/Accuracy 0.01 / 0.1 Ù ; 0.001 / 0.1 kÙ ; 0.01 MÙ ±1 % full scale Salinity Range 0.0 to 80.0 ppt Resolution/Accuracy 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt ±1 % full scale TDS Range 0.050 ppm to 500 ppt (@ TDS factor 1.00) Resolution/Accuracy 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt Resolution/Accuracy 0.10 C (0.1 0 F); ±0.3 0 C(± 0.5 0 F) Temp. Coefficient Linear & pure ; 0.000 to 10.000 % Normalization Temperature 15.0 to 30.0 0 C (59.0 to 86.0 0 F) Built-in Electrode Arm Yes Compensation ATC / MTC Memory 100 data sets electrode Included, 2 cell epoxy body Conductivity electrode, K=1.0, Power Requirements Included, 100 /240VAC SMPS Power Adapter , 9V,6W
4Turbidity meter (Benchtop)/ (Portable)(with amc for 5 years) Eutech, WTW, Hach,Oakton Accuracy: ±2% of reading plus 0.01 FNU/NTU from 0 - 1000 FNU/NTU Certifications: CE, KC, RCM Communication: USB Compliance: ISO Data logging: 2000 total logs, includes reading log, verification log and calibration log Display: 17.8 mm colour touch screen Interface: 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner Light source: Light-emitting diode (IR LED) at 860 ± 30 nm Measurement method: Nephelometric Operating temperature range: 0 - 40 °C Power requirements (Voltage): 100 - 240 VAC Range: 0 - 1000 NTU , NTU/FNU: 0 - 1000 , Reading modes: Single, continuous, Rapidly Settling Turbidity, signal averaging on or off Regulatory: Meets ISO 7027, DIN EN 27027, DIN 38404 and NFT 9033, Repeatability: ±1% of reading or 0.01 FNU/NTU, whichever is greater (under reference conditions) Response time: Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average) Sample cell compatibility: Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used. Sample requirements: 25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F) Source Lamp: LED Stabilisation time: Immediately Storage conditions: -20 to 60 °C Units: FNU and NTU
5Distillation plant Make Borosil, Glassco, All Quartz Double Distillation Unit Demountable Boiler Panel Series, Vertical Model with Distillation Apparatus Power Supply Capacity 2.5 Ltr/hr
6Hot Air Oven Make NST,OPTICS TECHNOLOGY, AMBASSADORSIZE:-18X18 X18 / 18x24x18 Double walled inside Aluminum/Stainless Steel 304 qty. Outside made of Mild steel and painted in Epoxy Powder Coating. Insulation of 75rnm by mineral Wool. Double walled inside Aluminum/Stainless Steel 304 qty. good stoving enamel with adjustable wire mesh nichol plated trays Heating Elements are on three sides" bottom LHS & RHS. ribs. With air ventilators on two sides. Microprocessed Electronic Digital Controller cum Indicator from few "C above ambient to 300" C ±0.5* C having two windows display SV & PV, auto tuning, timer up 999 mts (selectable) low & high temp. accuracy alarm, cycle, timer with buzzer. Outside made of Mild steel and painted in Epoxy Powder Coating. Insulation of 75rnm by mineral wool. Double walled inside Aluminum/Stainless Steel 304 qty. Heating Elements are on three sides" bottom LHS & RHS. ribs. With air ventilators on two sides. Steel stand should be provided along with tyres on which instrument has to kept .Traceabilitycalibration certificate of controller should be providedInstrument should be calibrated from NABL calibration laboratory. Includes AMC for 5 years
7Autoclave Vertical Make POPULAR ,NST, AMBASSDOR Size-78 ltr/ 98 ltr • It should have double wall construction with boiler made of Stainless Steel 16 gauge sheet. Outer shall is also made of Stainless Steel Sheet/ Mild Steel. Boiler and outer shell is provided with air insulation. Lid is made of Stainless Steel Sheet and tightened all-round by radial locking . Joint less gaskets are made of Neoprene rubber. These sterilizers are hydraulically tested upto 40 PSI. • Should have fully automatic PID Controller • Automatic timer electronic 999 mts • Sterilizers are fitted with water level arrangement to indicate water position inside the boiler. Pressure gauge, Air/Steam release cock two safety valve are also provided. The autoclave is fitted with indfoss pizzostat and can be set between 10 to 20 PSI. • Immersion type heating element heats the water and steam to desired temp. and pressure are attained. We have provided all autoclaves to cut-off automatically when the autoclave is dry. Supplied complete with S.S. basket, cord and plug to work on 220 Volts 50 cycles A.C. supply • Traceabilitycalibration certificate of controller should be provided • Instrument should be calibrated from NABL calibration laboratory. • Includes AMC for 5 years
8Hygrometer Make HTC, Temp.Range -500C ~ +700C Temp. Measuring Accuracy: ± 10C Temp. Resolution: 0.10C Humidity Meas.Range: 10% RH ~ 99% Humidity Accuracy: ±5% RH Humidity Resolution: 1%
9Thermometer simple and with probe Make LT(Type k), Thomassci, Hanna Digital LCD Thermometer with sensor probe
10Analytical Balance (with 5 years AMC) Radwag, Mettler Toledo, Sartorius, shimazhu Analytical Balance Capacity 220 gm Accuracy 0.01 mg with internal calibration Pan Size Ø 90 mm
11Calibrated Weights Radwag, Mettler Toledo, Sartorius, denver, wensar Standard Weight Box Class F1 capacity 1 mg to 200 gm with NABL Accredited Lab Calibration Certificate (Set of 23 wire weights)
12Dessicator Make Borosil, Glassco, Thermo 250 mm along with 1 kg silia gel (Qualigen)
13Bacteriological incubator Make NST,AMBASSADOR,OPTICS TECHNOLOGY Size 18x24x18.The incubator should havedouble door outer is metal door and inside is glass door in stainless steel frame. There will be glass window outside .Two adjustable  air ventilators are placed near the  top of the sides.The temperature is controlled by an Electronic microprocessed Temperature Controller cum Indicator from few °C  above ambient to 70 deg. C  with sensitivity of plus minus 0.5 deg. C  supplied complete with two pilot lamps,  aircirculating fan   perforated shelves adjustable at any level, having  arrangement to fit the automatic timer to work on 220/230 volts A.C. only with cord and plug.Double walled inside Aluminum/Stainless Steel 304 qty.Steel stand should be provided along with tyres on which instrument has to kept .Good stoving enamel with adjustable wire mesh nichol plated traysTraceabilitycalibration certificate of controller should be provided Instrument should be calibrated from NABL calibration laboratory.Includes AMC for 5 years