Supply Of ( 1 ) Peritoneal Dialysis Items ( Drugs & Consumables For Peritoneal Dialysis ) And Related Services.- Peritoneal Dialysis Solution With 4.25% To 4.5% Dextrose In Twin Bag Container: With Colour Coding Connectors For Quick Recognition
Tender Overview
Project Description
Supply Of ( 1 ) Peritoneal Dialysis Items ( Drugs & Consumables For Peritoneal Dialysis ) And Related Services.- Peritoneal Dialysis Solution With 4.25% To 4.5% Dextrose In Twin Bag Container: With Colour Coding Connectors For Quick Recognition Of Glucose Strengths Each 1000 Ml Contains: ) Sodium 132 -135 Calcium 1.75 Magnesium 0.25-0.5 Chloride 96 - 105 Lactate 35 - 40 Ph 5.0 -6.0 Sterile Non-Pyrogenic Shelf Life 2 Years Storage-Not Above 25-30 Degree Celsius Bag Material: Pvc Or Pvc-Free And Plasticizer-Free Bags, Peritoneal Dialysis Solution With Icodextrin 7.5% In Twin Bag Container: With Colour Coding Connectors For Quick Recognition Of Glucose Strengths Each 1000 Ml Contains: ) Sodium 132 -135 Calcium 1.75 Magnesium 0.25-0.5 Chloride 96 - 105 Lactate 35 - 40 Ph 5.0 -6.0 Sterile Non-Pyrogenic Shelf Life 2 Years Storage-Not Above 25-30 Degree Celsius Bag Material: Pvc Or Pvc-Free And Plasticizer-Free Bags, Peritoneal Dialysis Solution With 1.5% Dextrose ( Specification As Per Item No.:1 - Packing Size Change ) , Peritoneal Dialysis Solution With 2.3% -2.5% Dextrose ( Specification As Per Item No.:2 - Packing Size Change ) , Dextrose 1.5%, 2.5%, 3.5% Monohydratate Peritoneal Dialysis Solution 2000 Ml, Tenckhoff Catheter Kits- Should Have Two Cuff Should Have A Pre-Formed 180&Deg; Angle Designed To Keep Both The Internal And External Portions Of The Catheter Positioned Downward Should Have 18G ( 1.27 Mm ) *7 Cm Introducer Needle, 0.038€ ( 0.965 Mm ) *70 Cm J / Straight Stainless Steel Guide Wire, 12Ml Syringe, 16 Fr Pull Apart Sheath / Dilator , Tunneling Stylet, Adaptor, Clamp, Cap Catheter Length-42 / 43 Cm Catheter Style- Tenckhoff Catheter Should Be Made Up Of Silicon Material Catheter Should Be Usfda Or Ce Certified, Curl Cath Catheter Kits- Should Have Two Cuff Should Have A Pre-Formed 180&Deg; Angle Designed To Keep Both The Internal And External Portions Of The Catheter Positioned Downward Should Have 18G ( 1.27 Mm ) *7 Cm Introducer Needle, 0.038€ ( 0.965 Mm ) *70 Cm J / Straight Stainless Steel Guide Wire, 12Ml Syringe, 16 Fr Pull Apart Sheath / Dilator , Tunneling Stylet, Adaptor, Clamp, Cap Catheter Length-62 / 63 Cm Catheter Style- Curl Cath Catheter Should Be Made Up Of Silicon Material Catheter Should Be Usfda Or Ce Certified, Swan Neck Tenckhoff Catheter, Left Should Have Two Cuff Should Have A Pre-Formed 180&Deg; Angle Designed To Keep Both The Internal And External Portions Of The Catheter Positioned Downward Catheter Length 43 Cm Catheter Style Swan Neck, Tenckhoff Catheter Should Be Made Up Of Silicon Material Catheter Should Be Usfda Or Ce Certified, Swan Neck Tenckhoff Catheter, Right Should Have Two Cuff Should Have A Pre-Formed 180&Deg; Angle Designed To Keep Both The Internal And External Portions Of The Catheter Positioned Downward Catheter Length 43 Cm Catheter Style Swan Neck, Tenckhoff Catheter Should Be Made Up Of Silicon Material Catheter Should Be Usfda Or Ce Certified, Pediatric Swan Neck Tenckhoff Catheter, Left Should Have Two Cuff Should Have A Pre-Formed 180&Deg; Angle Designed To Keep Both The Internal And External Portions Of The Catheter Positioned Downward Catheter Length 37.5 Cm Catheter Style Swan Neck, Tenckhoff Catheter Should Be Made Up Of Silicon Material Catheter Should Be Usfda Or Ce Certified, Pediatric Swan Neck Tenckhoff Catheter, Right Should Have Two Cuff Should Have A Pre-Formed 180&Deg; Angle Designed To Keep Both The Internal And External Portions Of The Catheter Positioned Downward Catheter Length 37.5 Cm Catheter Style Swan Neck, Tenckhoff Catheter Should Be Made Up Of Silicon Material Catheter Should Be Usfda Or Ce Certified, Pediatric Tenckhoff Catheter- Should Have Two Cuff Should Have A Pre-Formed 180&Deg; Angle Designed To Keep Both The Internal And External Portions Of The Catheter Positioned Downward Pediatric Tenckhoff Catheter Length-31Cm Catheter Should Be Made Up Of Silicon Material Catheter Should Be Usfda Or Ce Certified, Neonatal Tenckhoff Peritoneal Dialysis Catheter- Should Have Two Cuff Should Have A Pre-Formed 180&Deg; Angle Designed To Keep Both The Internal And External Portions Of The Catheter Positioned Downward Neonatal Tenckhoff Catheter Length-37Cm Catheter Should Be Made Up Of Silicon Material Catheter Should Be Usfda Or Ce Certified
BOQ
| Sl. No. | Item Title | Packing unit |
| 1 | Peritoneal Dialysis solution with 4.25% TO 4.5% Dextrose in twin bag container: With colour coding connectors for quick recognition of glucose strengths Each 1000 ml contains:)Sodium 132 -135Calcium 1.75magnesium 0.25-0.5 chloride 96 - 105Lactate 35 - 40pH 5.0 -6.0Sterile Non-pyrogenicShelf life 2 YearsStorage-Not Above 25-30 Degree CelsiusBag material: PVC or PVC-free and plasticizer-free bags | 2000 ML X 1 Bag |
| 2 | Peritoneal Dialysis solution with Icodextrin 7.5% in twin bag container: With colour coding connectors for quick recognition of glucose strengths Each 1000 ml contains:)Sodium 132 -135Calcium 1.75magnesium 0.25-0.5 chloride 96 - 105Lactate 35 - 40pH 5.0 -6.0Sterile Non-pyrogenicShelf life 2 YearsStorage-Not Above 25-30 Degree CelsiusBag material: PVC or PVC-free and plasticizer-free bags | 2000 ML X 1 Bag |
| 3 | Peritoneal Dialysis solution with 1.5% Dextrose (Specification as per item no.:1 - Packing Size Change) | 1000 ML X 1 Bag |
| 4 | Peritoneal Dialysis solution with 2.3% -2.5% Dextrose (Specification as per item no.:2 - Packing Size Change) | 1000 ML X 1 Bag |
| 5 | Dextrose 1.5%, 2.5%, 3.5% Monohydratate Peritoneal Dialysis Solution 2000 ml | 2000 ML X 1 Bag |
| 6 | Tenckhoff Catheter Kits-Should have two CuffShould have a pre-formed 180° angle designed to keep both the internal and external portions of the catheter positioned downwardShould have 18G(1.27 mm)*7 cm Introducer Needle, 0.038â€(0.965 mm) *70 cm J/Straight Stainless Steel Guide wire, 12ml Syringe, 16 Fr Pull Apart Sheath/ Dilator ,Tunneling Stylet, Adaptor, Clamp, CapCatheter Length-42/43 cmCatheter Style- TenckhoffCatheter should be made up of silicon Material Catheter should be USFDA or CE Certified | 1 Unit |
| 7 | Curl Cath Catheter Kits-Should have two CuffShould have a pre-formed 180° angle designed to keep both the internal and external portions of the catheter positioned downwardShould have 18G(1.27 mm)*7 cm Introducer Needle, 0.038â€(0.965 mm) *70 cm J/Straight Stainless Steel Guide wire, 12ml Syringe, 16 Fr Pull Apart Sheath/ Dilator ,Tunneling Stylet, Adaptor, Clamp, CapCatheter Length-62/63 cmCatheter Style- Curl CathCatheter should be made up of silicon Material Catheter should be USFDA or CE Certified | 1 Unit |
| 8 | Swan Neck Tenckhoff Catheter, LeftShould have two Cuff Should have a pre-formed 180° angle designed to keep both the internal and external portions of the catheter positioned downwardCatheter Length 43 cmCatheter Style Swan Neck, TenckhoffCatheter should be made up of silicon Material Catheter should be USFDA or CE Certified | 1 Unit |
| 9 | Swan Neck Tenckhoff Catheter, RightShould have two Cuff Should have a pre-formed 180° angle designed to keep both the internal and external portions of the catheter positioned downwardCatheter Length 43 cmCatheter Style Swan Neck, TenckhoffCatheter should be made up of silicon Material Catheter should be USFDA or CE Certified | 1 Unit |
| 10 | Pediatric Swan Neck Tenckhoff Catheter, LeftShould have two CuffShould have a pre-formed 180° angle designed to keep both the internal and external portions of the catheter positioned downwardCatheter Length 37.5 cmCatheter Style Swan Neck, TenckhoffCatheter should be made up of silicon Material Catheter should be USFDA or CE Certified | 1 Unit |
| 11 | Pediatric Swan Neck Tenckhoff Catheter, RightShould have two CuffShould have a pre-formed 180° angle designed to keep both the internal and external portions of the catheter positioned downwardCatheter Length 37.5 cmCatheter Style Swan Neck, TenckhoffCatheter should be made up of silicon Material Catheter should be USFDA or CE Certified | 1 Unit |
| 12 | Pediatric Tenckhoff Catheter-Should have two CuffShould have a pre-formed 180° angle designed to keep both the internal and external portions of the catheter positioned downwardPediatric Tenckhoff CatheterLength-31cmCatheter should be made up of silicon Material Catheter should be USFDA or CE Certified | 1 Unit |
| 13 | Neonatal Tenckhoff Peritoneal Dialysis Catheter-Should have two CuffShould have a pre-formed 180° angle designed to keep both the internal and external portions of the catheter positioned downwardNeonatal Tenckhoff CatheterLength-37cmCatheter should be made up of silicon Material Catheter should be USFDA or CE Certified | 1 Unit |