Jjm Aloor Grama Panchayath Appendix 1 Supply And Erection Of Pumps Motors Jjm Aloor Grama Panchayath Appendix 1 Supply And Erection Of Pumps Motors
Tender Overview
Project Description
Jjm Aloor Grama Panchayath Appendix 1 Supply And Erection Of Pumps Motors Jjm Aloor Grama Panchayath Appendix 1 Supply And Erection Of Pumps Motors
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Dec-2021 | corrigendum | Date | 17-Dec-2021 |
BOQ
| Sl. No. | Item Description |
| 1 | Pumps and Motors |
| 2 | Supply ,erection,testing and commissioning of KWA pre- qualified reputed make Centrifugal motorpumpsets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate withcoupling ,coupling guard foundation bolts and nuts etc.complete suitable for coupling the pump and motorabove the base plate etc. complete including providing suitable concrete foundation including cost ofcement sand and metal etc.complete.The pumpset shall be coupled with the motor specified in item no.1(b) given below.Make-(as per KWA approved list), Discharge:- 25 LPS, Total Head ----- 70m , Efficiency----- 75% ,Pump Speed ---1500 RPM, suction pipe-10m.Minimum thickness for MS pipes thickness 10mmminimum thickness.2) Motor:-Supply ,erection,testing and commissioning of KWA pre- qualified reputedmake horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pumpworking 3 phase 50Hz AC supply, working voltage 415V/3300V ( select the suitable).The motor shallconfirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement , sandand metal etc.complete.Flexible coupling shall be used for coupling of pumps and motors.3) Starter :-Supply ,erection,testing and commissioning of suitable rating(Fully automatic starter with air breakcontact for less than 100HP and for above 100HP FCMA starters to be used)starter suitable for the above motor with over voltage and under voltage protection ,single phase preventer over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practiceetc.complete.4. Panel board (suitable for operating two pump sets but one pump set at a time) - Supply,erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proofcommon control panel board consisting of 1 no. suitable capacity MCCB as incomer and 2 Nos ofsuitable capacity MCCB as outgoing ( the two MCCB s are interlocking with each other) providingsuitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps,1 no . volt meter with selector switch, 1 no. Ammeter with selector switch etc. Complete and provided witha common earth bus for the entire panel and inter connect with the MCCBS as per IE rules and code ofpractice. The panel shall be fitted on a common base frame on suitable foundation. 5. Cabling work -Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set frompanel board to starter and from starter to motor considering energy conservation.6.Earthing - Supply of allmaterials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buriedin ground and giving double earthing to motor, starter, panel board etc.as per IE standards.7. Capacitor -Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a powerfactor above 0.95 . The capacitor shall confirm to IS 2834 8. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating.Fitting of valves shall include proper RCC support, fitting of valves shall include proper RCC support especially for Non return valves. 9. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe for a total length of 10 m. suitable for the above pump set and suitable sizefoot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc.complete and connecting the delivery side of the pump with the valves and suitable specials to connectwith the pumping main 10. Supply of reputed make pressure guage ( minimum 150mm size) cock and allother accessories suitable for the pump set 11.Erection and commissioning of the motor pump set with allaccessories detailed above including civil, electrical and mechanical works, suitable concrete foundation ,including fixing the starter , motor, panel board, etc, installing all electrical items, wiring, earthing. givingconnection etc as directed by departmental officers as per IEI rules and IS specification, interconnection with existing pumping main , fitting suction and delivery pipe and specials, sluice valve, reflux valves, etccomplete and trial run for a period of 72 hours as per the specification including all cost of cement and all other materials with two years guarantee etc complete. |
| 3 | Supply and Erecting at site, brand new Bore well submersible motor pumpsets, slow speed with open type bronze impeller(LTB2), stainless steel pump shaft(SS 316), stainless steel column (intermediate)shaft, water lubricated type,sleeve (SS410) column assembly,suitable column pipe etc.neck ring(bronzeLTB2),sleeve(SS410),spider bush, strainers and all accessories conforming to relevent IS. The pumpsetshall be coupled with the motor specified in item no. 1(b) given below. Make ------ (as per KWA approvedlist)Capacity 3.5 LPS Total Head ----- 75m Efficiency ----- 70% Pump Speed ---1500 RPM-Slow speed.Minimum thickness for MS pipes minimum thickness 10mm. .2) Motor :-Supply ,erection,testing andcommissioning of KWA pre- qualified reputed make horizontal solid shaft foot mounted TEFC squirrelcage induction motor suitable for the above pump working 3 phase 50Hz AC supply, working voltage415V/3300V ( select the suitable).The motor shall confirm to EEFI/IS 325 including providing suitableconcrete foundation including cost of cement , sand and metal etc.complete.For 3300volts motors, digitalmotor protection relay shall be included in starter as per present IE rules.Flexible coupling shall be usedfor coupling of pumps and motors.3) Starter:- Supply ,erection,testing and commissioning of suitablerating(Fully automatic starter with air break contact for less than 100HP and for above 100HP FCMAstarters to be used)starter suitable for the above motor with over voltage and under voltage protectionsingle phase preventer over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc.complete.4) Panel board (suitable for operating two pump sets but one pump set at a time) - Supply, erection, testing and commissioning of cubical type floormounted MS fabricated dust and vermin proof common control panel board consisting of 1 no. suitablecapacity MCCB as incomer and 2 Nos of suitable capacity MCCB as outgoing ( the two MCCB s areinterlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBsand fitted with 3 Nos of indicator lamps, 1 no . volt meter with selector switch, 1 no. Ammeter withselector switch etc. Complete and provided with a common earth bus for the entire panel and interconnect with the MCCBS as per IE rules and code of practice. The panel shall be fitted on a commonbase frame on suitable foundation. 5) Cabling work - Supply, laying, testing and commissioning ofsuitable size XLPE cables for the above pump set from panel board to starter and from starter to motorconsidering energy conservation.6)Earthing - Supply of all materials and providing suitable earthing byusing suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing tomotor, starter, panel board etc.as per IE standards.7.)Capacitor - Supply, erection, testing andcommissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95 . Thecapacitor shall confirm to IS 2834 8) Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shallinclude proper RCC support especially for Non return valves 9) delivery pipe connections - Supply andfitting of suitable size best quality MS pipe for a total length of 10 m. suitable for the above pump set andvalve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and valve with suitable flanges,nut and bolts IR sheet etc. complete andconnecting the delivery side of the pump with the valves and suitable specials to connect with thepumping main 10. Supply of reputed make pressure guage ( minimum 150mm size) cock and all otheraccessories suitable for the pump set 11.Erection and commissioning of the motor pump set with all accessories detailed above including civil, electrical and mechanical works, suitable concrete foundation ,including fixing the starter , motor, panel board, etc, installing all electrical items, wiring, earthing. givingconnection etc as directed by departmental officers as per IEI rules and IS specification, interconnectionwith existing pumping main , fitting suction and delivery pipe and specials, sluice valve, reflux valves, etccomplete and trial run for a period of 72 hours as per the specification including all cost of cement and allother materials with two years guarantee etc complete. |
| 4 | Supply, erection, testing and commissioning of KWA pre-qualified reputed make vertical turbine pumpsets with stainless steel shaft SS 316,bronze LTB2 impeller, Cast iron casing, Bronze LTB2 neckring, SS 410 sleeve, (column pipe thickness 10mm) (minimum), flanged column pipe with SS strainer anddelivery pipe and all other accessories confirmed to ISS with folowing specification. The pumpset shall becoupled with motor specified.The duty condition is as follows Capacity 111 LPS Total Head ----- 19mEfficiency ----- 70% Pump Speed ---1500 RPM 2. Motor -Supply, erection, testing and commissioning ofKWA prequalified reputed make squirrel cage induction motor suitable for the above pump set working 3phase, HP, 50 Hz , 415 V working in AC supply with 1500 rpm speed. The motor shall confirm to ELFI/IS325 including suitable size FRLS 3 core flexible cable etc complete.3.Starter - Supply erection, testingand commissioning of suitable rating (Fully automatic starter with air break contact for less than 100HPand for above 100HP FCMA starters to be used) starter for the above motor with over voltage and undervoltage protection , single phase preventer , over load relay with motor protection relay with mainconductor and bypass conductor as per IE rules and code of practice etc, complete 4.Panel board (suitable for operating two pump sets bunt one pumpset at a time ) - Supply, erection and commissioningof cubical type MS fabricated dust and vermin proof common control panel board consisting of 1 no.suitable capacity MCCB as incomer and 2 nos of suitable capacity MCCB as out going , providingsuitable size Aluminium bus bar , 3 nos of indicator lamps , 1 no Volt meter with selector switch ,Ammeter with selector switch etc complete and provide with a common earth bus bar for the entire paneland inter connect with the MCCBs as per IE rules and code of practice.The panel shall be fitted on acommon baseframe on suitable foundation .5.Cabling work-Supply,laying ,testing and commission ofsuitable size XLPE cable for the above pump set from panel board to starter and from starter to motorconsidering energy conservation.6.Earthing- Supplying of all materials and providing suitable earthing byusing suitable size pipe/ plate earthing GI / copper strip buried in ground and giving double earthing tomotor, starter, panel board etc as per IE standards. 7.Capacitor- Supply ,erection testing andcommissioning duty APP capacitor for the motor get a power factor above 0.95 . The capacitor shallconfirm to IS 2834.8.Valves- Supply of suitable size best quality heavy duty ISI marked double flangedsluice and Non return valves with suitable pressure rating. Fitting of valves shall include proper RCCsupport especially for Non return valve. 9.delivery pipe connections-Supply and fitting of suitable sizebest quality GI/MS pipe of thickness not less than 8mm for a total length of 10 meter suitable for theabove pump set by using suitable flanges,nut and bolts, IR sheet etc complete.10. Supply of reputedmake pressure guage ( minimum 150mm size) cock and all other accessories suitable for the pump set11.Erection and commissioning of the motor pump set with all accessories detailed above including civil,electrical and mechanical works, suitable concrete foundation , including fixing the starter , motor, panelboard, etc, installing all electrical items, wiring, earthing. giving connection etc as directed bydepartmental officers as per IEI rules and IS specification, interconnection with existing pumping main ,fitting suction and delivery pipe and specials, sluice valve, reflux valves, etc complete and trial run for aperiod of 72 hours as per the specification including all cost of cement and all other materials with twoyears guarantee etc complete |
| 5 | Supply and Erecting at site, brand new Bore well submersible motor pumpsets, slow speed with opentype bronze impeller(LTB2), stainless steel pump shaft(SS 316), stainless steel column (intermediate)shaft, water lubricated type,sleeve (SS410) column assembly,suitable column pipe etc.neck ring(bronzeLTB2),sleeve(SS410),spider bush, strainers and all accessories conforming to relevent IS. The pumpsetshall becoupled with the motor specified in item no. 1(b) given below. Make ------ (as per KWA approvedlist) Capacity 2.5 LPS Total Head ----- 112m Efficiency ----- 70% Pump Speed ---1500 RPM-Slow speed.Minimum thickness for MS pipes minimum thickness 10mm. .2) Motor :-Supply ,erection,testing andcommissioning of KWA pre- qualified reputed make horizontal solid shaft foot mounted TEFC squirrelcage induction motor suitable for the above pump working 3 phase 50Hz AC supply,working voltage415V/3300V ( select the suitable).The motor shall confirm to EEFI/IS 325 including providing suitableconcrete foundation including cost of cement , sand and metal etc.complete.For 3300volts motors, digitalmotor protection relay shall be included in starter as per present IE rules.Flexible coupling shall be usedfor coupling of pumps and motors.3) Starter:- Supply ,erection,testing and commissioning of suitablerating(Fully automatic starter with air break contact for less than 100HP and for above 100HP FCMAstarters to be used)starter suitable for the above motor with over voltage and under voltage protectionsingle phase preventer over load relay with motor protection relay with main contactor and bypasscontactor as per IE rules and code of practice etc.complete.4) Panel board (suitable for operating twopump sets but one pump set at a time) - Supply, erection, testing and commissioning of cubical type floormounted MS fabricated dust and vermin proof common control panel board consisting of 1 no. suitablecapacity MCCB as incomer and 2 Nos of suitable capacity MCCB as outgoing ( the two MCCB s areinterlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBsand fitted with 3 Nos of indicator lamps, 1 no . volt meter with selector switch, 1 no. Ammeter withselector switch etc. Complete and provided with a common earth bus for the entire panel and interconnect with the MCCBS as per IE rules and code of practice. The panel shall be fitted on a commonbase frame on suitable foundation. 5) Cabling work - Supply, laying, testing and commissioning ofsuitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation.6)Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing tomotor, starter, panel board etc.as per IE standards.7.)Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95 . Thecapacitor shall confirm to IS 2834 8) Valves - Supply of suitable size best quality heavy duty ISI markedCI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shallinclude proper RCC support especially for Non return valves 9) delivery pipe connections - Supply andfitting of suitable size best quality MS pipe for a total length of 10 m. suitable for the above pump set andvalve with suitable flanges, nutand bolts IR sheet etc. complete and connecting the delivery side of thepump with the valves and valve with suitable flanges, nut and bolts IR sheet etc. complete andconnecting the delivery side of the pump with the valves and suitable specials to connect with thepumping main 10. Supply of reputed make pressure guage ( minimum 150mm size) cock and all otheraccessories suitable for the pump set 11.Erection and commissioning of the motor pump set with allaccessories detailed above including civil, electrical and mechanical works, suitable concrete foundation ,including fixing the starter , motor, panel board, etc, installing all electrical items, wiring, earthing. givingconnection etc as directed by departmental officers as per IEI rules and IS specification, interconnectionwith existing pumping main , fitting suction and delivery pipe and specials, sluice valve, reflux valves, etccomplete and trial run for a period of 72 hours as per the specification including all cost of cement and allother materials with two years guarantee etc complete. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender