Ge / Sp / Token-43 / 2021-22 Repair / Replacement And Maint Of Unsv Ug Cable , Acsr Conductor, Lt Panel, Feeder Pillar Box, Earthing Including Painting Of Rcc / Steel Poles Of Omq Sp Area, Wac Offrs Mess, Smc Wac Bldg Area, Wac Smqs And Airmen
Tender Overview
Project Description
Ge / Sp / Token-43 / 2021-22 Repair / Replacement And Maint Of Unsv Ug Cable , Acsr Conductor, Lt Panel, Feeder Pillar Box, Earthing Including Painting Of Rcc / Steel Poles Of Omq Sp Area, Wac Offrs Mess, Smc Wac Bldg Area, Wac Smqs And Airmen Billets / Mess Under Ge ( Af ) Subroto
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Dec-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-Dec-2021 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring( light ,fan, socket or power) complete,fitting such as switches, ceiling roses,pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc.Complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and acessories concealed in wall / ceiling or surface conduit wiring on ceiling /wall terminated in flush metal box alongwith outer cover plate for mounting modular switch, socket and electronic regulator along with provn ofearth wire of PVC insulated, unseathed,1100 V grade cable multi stranded FRLS ISI markedcopper conductor of size 1.5 sqmm for One light point/c fan/ Exh fan controlled by one switch one way. Complete all as specified and directed by Engineer-in-Charge. |
| 3 | All as per srl item2 above but for one C/ fan/Exhaust fan point controlled by one switch regulator. |
| 4 | All as per item No 2 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs. |
| 5 | All as per item No 2 above but for one 3 pin 5 amps socket outlet on the same board with other switchs. |
| 6 | All as per item No 2 above but for one light point controlled by two way switches. |
| 7 | All as per item No 2 above but for Call bell controled by one push button on indipendent board . |
| 8 | All as per item No 2 above but with 2.5 Sq mm cable for Independent one 3 pin 15 Amps socket outlet In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire. |
| 9 | M&L for point wiring for one light fitting / one fan point controled by one switch with 1.5 Sq mm PVC insulated copper conductor cable drawing in and including PVC Casing/capping with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly with 3mm thick plastic laminated sheet cover completefor one light point controlled by one switch complete all as specified and directed by Engineer in Charge. |
| 10 | All as per srl item9 above but for one fan point controlled by one switch through regulator. |
| 11 | All as per srl item 9 above but for one 5 pin 5 amps socket outlet on the independent board. |
| 12 | All as per item No 9 above but for one 3 pin 5 amps socket outlet on the same board with other switchs. |
| 13 | All as per item No 9 above but for Call bell point. |
| 14 | All as per item No 9 above but with 2.5 Sqmm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire. |
| 15 | M&L for point wiring with 1.5sqmm PVC insulated unsheathed multi stranded copper conductor cable drawing in existingsteel/PVC conduit with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly excluding 3mm sheet metal box and hylam sheet completefor one light/fan point controlled by one switch complete all as specified and directed by Engineer in Charge. |
| 16 | All as per srl item15 above but for one fan point controlled by one switch through regulator. |
| 17 | All as per srl item 15 above but for one 5 pin 5 amps socket outlet on the independent board. |
| 18 | All as per item No 15 above but for one 3 pin 5 amps socket outlet on the same board with other switchs. |
| 19 | All as per item No 15 above but for one light point controlled by two way switches. |
| 20 | All as per item No 15 above but for Call bell point. |
| 21 | All as per item No 15 above but with 2.5 Sq mm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire. |
| 22 | S&Fin replacement switch piano, flush type single pole, one way, 5 Amps, 240 volts Complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&Fin replacementswitch piano, flush type single pole, one way, 15 Amps, 240 volts Complete all as specified and directed by Engineer-in-Charge. |
| 24 | S&Fin replacement switch piano, flush type single pole, two way, 5 Amps, 240 volts Complete all as specified and directed by Engineer-in-Charge. |
| 25 | S&Fin replacement socket outlet 3 pin 5 Amps Complete all as specified and directed by Engineer-in-Charge. |
| 26 | S&Fin replacement socket16 Amps, 2 in 1, flush type Complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply & fix in replacementbell push, flush type, 5 Amps, 240 volts Complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply & fix in replacement Fan Regulator step type 120 watt, 240 volt complete .Complete all as specified and directed by Engineer-in-Charge. |
| 29 | S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. |
| 30 | S & FModular Socket, 6A - 2/3 pin combined 2 module,suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. |
| 31 | S & F Modular switch 2 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&FModular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. |
| 33 | S & FModular Socket, 16A - 2/3 pin combined 2 module,suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and fixModular bell push 1 Module 5 Amps suitable for 240 volt Complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and fixModular electronic Fan Regulator rotary flush step type 120 watt, 240 volt complete |
| 36 | Supply and fix White cover plate with frame,2 module Complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and fix White cover plate with frame,3 module Complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and fix White cover plate with frame,4 module Complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and fix White cover plate with frame,6 module Complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and fix White cover plate with frame,8 module Complete all as specified and directed by Engineer-in-Charge. |
| 41 | S & FModular metal flush box 3 module Complete all as specified and directed by Engineer-in-Charge. |
| 42 | S & FModular metal flush box 4 module Complete all as specified and directed by Engineer-in-Charge. |
| 43 | S & FModular metal flush box 6 module Complete all as specified and directed by Engineer-in-Charge. |
| 44 | S&F in replacement Electric calling Bell Ding Ding Type suitable for 230 volts. Complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply and fixingin replacement ceiling roses, surface bakelite 65x50mm ,3 terminals3 phase, PVC/Polycarbonate, isolated body Complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply and fixing in replacementPVC gang box suitable for one switch 5 Amps complete with screw and necessary arrangement complete all as specified and directed by Engineer in Charge. |
| 47 | All as per srl item 46 above but for one 5 amps switch socket outlet. |
| 48 | All as per srl item 46 above but for one 15 amps switch socket outlet. |
| 49 | M & L in replacement sheet metal enclosure with double door category of protectiontype IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCB SPN 240 Volts, 2 way concealed in wall such as front cover shall be seen flush with the wall surface Complete all as specified and directed by Engineer-in-Charge. |
| 50 | Taking down the old white hylium sheet from the existing flash metal box and replacing new supper quality white hylium sheet of size 8\" x 10\" complete all as specified and as directed by Engineer-in-Charge. |
| 51 | All as per srl item 50 above but of size 5\" x 5\" complete all as specified and as directed by Engineer-in-Charge. |
| 52 | All as per srl item 50 above but of size 8\" x 5\" complete all as specified and as directed by Engineer-in-Charge. |
| 53 | All as per srl item 50 above but of size 9\" x 13\" complete all as specified and as directed by Engineer-in-Charge. |
| 54 | S&F in repair of sub main wiring with 2 single core 04 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigidnon- metallic PVC/metallic conduit 25 mm dia incl 4.0 Sq mm PVC insulated single core copper conductor cable forcontinuous earth wire. Note:- Three run of PVC cable measured as one unit length. |
| 55 | S&F in repair of sub main wiring with 2 single core 04 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in and incl rigidnon metallic PVC conduit 25 mm dia incl 4.0 Sq mm PVC insulated single core copper conductor cable forcontinuous earth wire. Note:- Three run of PVC cable and one run of PVC conduit measured as one unit length. |
| 56 | All as per Item No 55 but with 2 single core 06 Sq mmincl 6 Sq mm PVC insulated single core copper conductor cable forcontinuous earth wire. |
| 57 | All as per Item No 55 but with 2 single core 10 Sq mmincl 10 Sq mm PVC insulated single core copper conductor cable forcontinuous earth wire. |
| 58 | M & L for rigid non metalic PVC medium grade conduit including junction boxes, tee, bends, elbows, reducers bell mouth tube ends,fixing accessories such as couplers, lock Nuts, saddle pipe hook etc for 25 mm dia.ISI Marked. |
| 59 | Supply & fix in replacement of Casing capping double lock type supper qualitysize 20 mm width ISI marked with fixing accessoriesComplete all as specified and directed by Engineer in Charge. |
| 60 | Supply and fixingwall mounted LEDbatten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cablefrom ceiling rose to fitting,and testing complete Complete all as specified and directed by Engineer in Charge. |
| 61 | S&F ultra modern design architectural design 34 watt 2x2 recess LED, 6000 K luminaire having glare free symmetrical illumination Complete all as specified and directed by Engineer-in-Charge. |
| 62 | S&F in replacementtube rod 14 watt, T5, 6500 K cool white. |
| 63 | S&F in replacement LED Tube rod 20 watt Complete all as specified and directed by Engineer in Charge. |
| 64 | S&F LED Bulb9 watt retrofit type 2700K (Yellow/white colour) Complete all as specified and directed by Engineer in Charge. |
| 65 | Supply & fix in replacement Batten Holder PVC white suitable for retrofit type CFL/LED Lamp Complete all as specified and directed by Engineer in Charge. |
| 66 | Supply & fix in replacement of Fluorescent Tube Light rod28 watt. |
| 67 | S&F Non Retrofit CFL 11 watt two pin 2700K (Yellow colour) complete all as specified |
| 68 | S&F in replacement of fan capacitor with copper wire plastic body 2.5 mfd. |
| 69 | S&F in replacement of fan capacitor with copper wire plastic body 3.15 mfd. |
| 70 | S&F in replacement of ceiling fan heavy duty 1200 mm sweep including necessary fixing arrangement for proper fixingas per site requirement complete all as specified and as directed by Engineer-in-Charge. |
| 71 | Taking down old unsv MCCB /DB of any size. |
| 72 | Supply and fixing load line vertical distribution board \"A, frame made out of CRCA 2mm thick mild steel sheet,double door, surface mounting TPN 8 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP \"A\" frame MCCB of 125 Amps =01 No MCBfor outgoing comlete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately. |
| 73 | Supply and fixing load line vertical distribution board \"A\" frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP \"A\" frame MCCB of 125 Amps =01 No MCBfor outgoing. Complete all as specified and directed by Engineer in Charge.Note :- MCB shall be measured and paid seperately. |
| 74 | Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCAmild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately. |
| 75 | Supply and fixingMCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCAmild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type Complete all as specified and directed by Engineer in Charge.Note :- MCB shall be measured and paid seperately. |
| 76 | Supply and fixingMCCB four Pole 125 Amps, 415 volt thermal release bearing cap 16 KA suitable for the MCB DB above comlete all as specified and as directed by Engineer-in-Charge. |
| 77 | Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, 240 volts, 6 to 40amps C Curvecapacity. |
| 78 | Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, and neutral, 240 volts, 40/63amps C Curvecapacity. |
| 79 | S&F in replacement MCBTP 25 to 63 Amps 10 KA, 440 volt 50 Hz all as specified ans directed by engineer in- charge. |
| 80 | S&F in repair MCBTP 100 Amps 16 KA 440 volt 50 Hz all as specified ans directed by engineer in- charge. |
| 81 | Supply & fix in replacement of brass screw 3/18, long threaded suitable for fixing switch boards. ( 100 Nos in one packet) |
| 82 | Supply & fix in replacement of brass screw 9/11, long threaded suitable for fixing switch boards. ( 100 Nos in one packet) |
| 83 | Supply & fix in replacement of stainless steelscrew 1/2\" long. ( 200 Nos in one packet) |
| 84 | Supply & fix in replacement of stainless steelscrew 1\" long.( 200 Nos in one packet) |
| 85 | Supply and fix in replacement of flexible wire twin core 23/.076 complete all as specified and as directed by Engr-in- Charge. |
| 86 | Excavation in trenches in hard and dense soil n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipe,foundation for poles, stay, laying cables etc and getting out Complete all as specified and directed by Engineer in Charge. |
| 87 | Returning filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm in hard/dense soil Complete all as specified and directed by Engineer in Charge. |
| 88 | Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point. Complete all as specified and directed by Engineer in Charge. |
| 89 | M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable Complete all as specified and directed by Engineer in Charge. Note:- Only punned thickness will be measured. |
| 90 | Supply and layingwell burnt sub class ‘B’ bricks old size as mechanicalprotection to under ground cables laying across the cable incld taking down u/s Complete all as specified and directed by Engineer in Charge. |
| 91 | Supply and laying GI pipe light grade galvanizedwith all fittings laid in trenches or fix on wall for cable protection of 80 mm bore incld taking down Complete all as specified and directed by Engineer in Charge. |
| 92 | All as per srl item No 91 above but size 50 mm bore Complete all as specified and directed by Engineer in Charge. |
| 93 | All as per srl item No 91 above but size 40 mm bore Complete all as specified and directed by Engineer in Charge. |
| 94 | Disconnecting,removing & taking out faulty U/G cable off sizes from trenches,wall and ducts Complete all as specified and directed by Engineer in Charge. |
| 95 | Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 300 sqmm x 3.5 core Complete all as specified and directed by Engineer in Charge. |
| 96 | All as per srl item No 95 above but size 185 Sq mm x 3.5 core Complete all as specified and directed by Engineer in Charge. |
| 97 | All as per srl item No 95 above but size 95 Sq mm x 3.5 core Complete all as specified and directed by Engineer in Charge. |
| 98 | All as per srl item No 95 above but size 50 Sq mm x 3.5 core. Complete all as specified and directed by Engineer in Charge. |
| 99 | All as per srl item No 95 above but size 35 Sq mm x 3.5 core. Complete all as specified and directed by Engineer in Charge. |
| 100 | All as per srl item No 95 above but size 10 Sq mm x 2 core Complete all as specified and directed by Engineer in Charge. |
| 101 | Material and labour for cuttingof road/ hard standing up to a size not exceeding 20cm widthand not exceeding 60cm in depth for laying ofcable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level complete all as specified and as directed by Engineer-in-charge. |
| 102 | M&L for preparation of old painted surface of steel tubular swaged poles (9 to 11 meter long) with good neck brackets including junction box, GI pipe and light fittings i.e HPSV/HPMV any rating and painting with one coat of aluminium paint including cleaning the acrylic cover and painting with blackto 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 103 | M&L forearthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected togalvanized earth lead wire4 mm dia by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate& copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plateNO 5 of SSR Part I (1991)and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner and PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in lieu of CI). Complete all as specified and directed by Engineer in Charge. |
| 104 | All as per item sr no. 103 above but using galvanised iron strip 25x4mm as earthhing lead |
| 105 | Material and labour in repairs for galvanisediron strip 25 X 4 mm with saddles and fixing screws and connected as per site requirement Complete all as specified and directed by Engineer in Charge. |
| 106 | S&F in replacement of MCCB 400 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 36 KA. |
| 107 | S&F in replacement of MCCB 250 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity35 KA. |
| 108 | S&F in replacement of MCCB 200 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity35 KA. |
| 109 | S&F in replacement of MCCB 125 Amps 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 16 KA. |
| 110 | S&F in replacement of MCCB 100 Amps415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 16 KA. |
| 111 | Supply and fixingin replacement load line vertical distribution board \"A\" frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP \"A\" frame MCCB of 250 Amps for incomer and MCBsfor outgoing comlete all as specified and as directed by Engineer-in-Charge. Note :- MCCB/MCB shall be measured and paid seperately. |
| 112 | Disconnecting to worn out cable off size from main control panel /LT over head line cutting worn out portion and reconnecting including suitable size of aluminium lugs & thimbles ,nuts, bolts & washers comlpete (excavation of necessary earth work shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.) |
| 113 | M&L for taking down street light, garden light and flood light fitting etc complete all as specified and as directed by Engineer-in-Charge. |
| 114 | S&F powder coated aluminium dia castand spun aluminium with clear/opal diffuser suitable for landscape lighting post top fitting,energy saving, environment friendly, long life aesthetically designed with good indriect symmetrical light distribution, die - cast aluminium landscape luminiaire with 40 watt LED 5700 K. Complete all as specified and directed by Engineer in Charge. |
| 115 | S&F Highly efficient mid power LED street light 35 W with pressure die cast aluminium housing, reflector and enclosed with toughened glass IP65. with 2 single cable PVCinsulator unsheathed 2.5 Sq mm with stranded copperconductor fixed on pole/wall/building. Complete all as specified and directed by Engineer in Charge. |
| 116 | Supply and fixenergy saving and enviornmental friendly long life versatile pressure die cast aluminium IP 65 roadway luminaire with high power70 watt LED , 6000K , with electronic driver, general spread, all accessories pre-wired and electric connection using PVC insulated and sheathed 1100 volts grade cable with copper conductor of size 2.5 sqmm complete with provn ofnuts and bolts fixing on walls/poles etc. Complete all as specified and directed by Engineer in Charge. |
| 117 | Supply and fix energy saving and enviornmental friendly long life versatile pressure die cast aluminium IP 65 roadway luminaire with high power150 watt LED , 6000K , with electronic driver, general spread, all accessories pre-wired and electric connection using PVC insulated and sheathed 1100 volts grade cable with copper conductor of size 2.5 sqmm complete with provn ofnuts and bolts fixing on walls/poles etc.Complete all as specified and directed by Engineer in Charge. |
| 118 | S&F 210 watt LED 6000K energy saving, enviromental friendly, long life, exclusive innovative die- cast aluminium IP 65 flood light with high power LEDs as light source, suitable for highlighting architectural features or retail spaces. Complete all as specified and directed by Engineer in Charge. |
| 119 | S&F in replacement of street light bracket of 1.5mtr long made out of 40mm dia medium grade GI pipe bend to shape at 120 degree & welded at required end including 02 Nos MS clamps of Flat iron 40x6mm. Complete all as specified and directed by Engineer in Charge. |
| 120 | S&F in replacement of pin type,porcelain,vitreous,white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100 mm height,65 mm dia for 1100 volts grade Complete all as specified and directed by Engineer in Charge. |
| 121 | S&F in replacement of shackle type,porcelain,vitreous,white,brown or green insulator 1100 Volts LT of size 100 mm high and 115 mm dia including galvanised mild steel straps of size 31x5 mm,washers,insulator bolts 14 mm dia,washers and nuts etc Complete all as specified and directed by Engineer in Charge. |
| 122 | M&L for cutting/trimming of branches of tree tuching/aproaching LT over lines of various spans(having 40 to 45 mtr) up to 3 mtr width on each side from difrent site of grith up to 10 cm with cutting equipments hacksaw,axe,ladders,rope and safety measures etc including disposal of trimmed branches 100 mtr away inside the cantonment area and cleaning the ares complete all as specified and directed by Engineer-in-charge. |
| 123 | M&L for re-streaching of loose LT over head line,aluminium conductor,GI guard wires and credals etc complete at various location and difrent span of 2 to 7 conductors with the help of rope and pullar etc complete all as specified and directed by Engineer-in-charge. |
| 124 | Supply and fix in replacement of flexible conduit pipe of size 25 mm siutable for insertion of electric wires etc complete all as specified and as directed at site. |
| 125 | M&L for precast cement concrete block masonry with solid blocks,exceeding 10 cm in width and setting in mortar type B1, 1:2:4 using 20 mm graded aggrigate complete all as specified and as directed. |
| 126 | Supply and stretching in replacement ACSRconductor of any size as per site requirement on existing LT poles including binding on existing insulator with aluminium binding wire 2mm dia,Complete all as specified and directed by Engineer in Charge.(Note:-For measurement and payment purpose of ACSR the weight of binding wire shall not be considered) |
| 127 | Supply and fix tape insulation PVC 25 mm wide in various colours of standard length complete all as specified and as directed by Engineer-in-Charge. |
| 128 | Supply and fixing in repairs post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed by Engineer-in-Charge.. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender