| 1 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 2 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. Salwood |
| 3 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 4 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 5 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 6 | Polishing on wood work with ready made wax polish of approvedbrand and manufacture : Old work |
| 7 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 8 | Dismantling steel work manually/ by mechanical means in built upsections without dismembering and stacking within 50 metres leadas per direction of Engineer-in-charge. |
| 9 | Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: G.S. Sheet |
| 10 | Dismantling cement asbestos or other hard board ceiling or partitionwalls including stacking of serviceable materials and disposal ofunserviceable materials within 50 metres lead. |
| 11 | Providing and fixing plain 5 mm thickPVCboardwithbeading & suitable screws for PVC board in ceiling with pvc beading etc. complete as per direction of Engineer in charge. (frame work to be paid separately): |
| 12 | Credit for Dismantaled existing steel work (truss and accessories as and where is available (the actual quantity of the materials will be measured after the dismantling. |
| 13 | Credit for Dismantaled existing CGI for foofing including ridges, hips, valleys and gutters and accessories as and where is available (the actual quantity of the materials will be measured after the dismantaling). |
| 14 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductornsingle core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 15 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 16 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm |
| 17 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm |
| 18 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 19 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 20 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 21 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
| 22 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet |
| 23 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push |
| 24 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 25 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 1 or 2 Module (75mmX75mm) |
| 26 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 27 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 28 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 29 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 30 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 31 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 32 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 33 | Supplying and fixing following rating, four pole, (three phaseand neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 34 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 35 | Supply and fixingIndoor Commercial LED Luminaires Integra Grand/Neo 10 WINTEGRAGRANDDLR15WLED840MOD light fitting LED Downlighter with aluminium housing with 15 watt LED lamp duly wired for use on 240 volt, 50 Hz single Ceiling cutout: Ø 175 mm, height 92 mm. phase AC supply i/c connection etc e/c 10 watt LED lamp as recd as per the sample approved. as per Engineer in inchrge. |
| 36 | Supplying and Installation of230mm blade sweep/300mmexhaust faninincluding Cutting making good the damage, connection, testing, commissioning etc. as required. |
| 37 | Supplying and fixing of 4 feet long, universal batten for LED tube including providing of double sided maximum 20 watt 6500K suitable to provide minimum 2200 lumen output LED tube for surface of wall/celing including connection, testing and commissioning etc. completeas required at siteof work ( in case of product not available in same wattage then fitting with same lumen output will be preferable over wattage for consideration. |
| 38 | Supply and fixingIndoor Commercial LED Luminaires Integra Grand/Neo 15 WINTEGRAGRANDDLR15WLED840MOD light fitting LED Downlighter with aluminium housing with 15 watt LED lamp duly wired for use on 240 volt, 50 Hz single Ceiling cutout: Ø 175 mm, height 92 mm. phase AC supply i/c connection etc e/c 12 watt LED lamp as recd as per the sample approved. as per Engineer in inchrge. |
| 39 | Supply , Installation, testing and commissioning of VENUSNEOHE2X2R36WLED840PIRSENSOR Venus Neo HE PIR Fixture size: (LxWxH) in (595x595x65) mm mm LED lightcomplete with all accessories etc. directly on ceiling , including connection with 1.5 sq. mm FRLSPVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 40 | Supply and fixingoutdoor coloredflood light Commercial LED Luminaires Integra Grand/Neo 50WINTEGRAGRANDDLR15WLED840MOD light fitting LED Downlighter with aluminium housing with 50 watt LED lamp duly wired for use on 240 volt, 50 Hz single . phase AC supply i/c connection etc e/c 10 watt LED lamp as recd as per the sample approved. as per Engineer in inchrge. |