Provn Of Comn Complex At Panagarh Military Station Under Ge ( Project ) Panagarh Provn Of Comn Complex At Panagarh Military Station Under Ge ( Project ) Panagarh

Tender Notice

30132025
Corrigendum : Provn Of Comn Complex At Panagarh Military Station Under Ge ( Project ) Panagarh Provn Of Comn Complex At Panagarh Military Station Under Ge ( Project ) Panagarh
Indian
West Bengal
17-12-2021
24-12-2021
27-12-2021

Tender Details

Provn Of Comn Complex At Panagarh Military Station Under Ge ( Project ) Panagarh Provn Of Comn Complex At Panagarh Military Station Under Ge ( Project ) Panagarh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Dec-2021 Revised BOQ BOQ 17-12-2021
2 11-Dec-2021 Amendment2 Financial Bid 17-12-2021
3 17-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 84000.00 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVN OF COMN COMPLEX AT PANAGARH MILITARY STATION UNDER GE (PROJECT) PANAGARH
Sl. No. Item Description
1Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil all as specified and directed.
2Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil all as specified anddirected.
3Excavation in trenches not exceeding 1.50 m wide and exceeding 1.50 m but not exceeding 3.0m in depth and getting out in soft/loose soil all as specified anddirected.
4M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) all as specified anddirected.
5M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface all as specified anddirected.
6M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified anddirected.
7M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified anddirected.
8M&L for hard core of gauge n. exc 63 mm graded, deposited, spread and level in layers n. exc 15 cm thick, wateredand rammed to a true surface with broken stone or boulders all as specified and directed..
9Material and labour for providing Plain Cement Concrete (1:4:8) type D-2, (using 40 mm grade stone aggregate) as infoundation, filling and mass concrete complete, all as specified and directed.
10M&L Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in cement morter 1:6 all as specified and directed. .
11Material and labour for half brick work in cement mortar (1:4) straight or curved on plan to any radius with locally available Subclass ‘B’ old size best quality bricks all as specified and directed.
12Material and labour for Damp proof course 40mm thick to horizontal or vertical surface in cement concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate, and applying evenly a coat of blown bitumen @ 1.50/sqm and binding with clean dry sand @ 0.05 cum/sqm complete all as specified and directed.
13Returning Filling in,including spreading, levelling, watering and well ramming in layers, not exc 25 cm in soft/loose soil all as specified and directed.
14Removing excavated material n exc 50 m and depositing where directed at level n exc 1.5m above the starting point all as specified and directed.
15M & L Moorum filling , laid in paving layers n. Exc 15cm thick, spread, levelled and rammed including watering, complete all as specified and directed.
16M & L for RCCM-25 (Design mix) as in footings, foundation beams, plinth beams bases for columns, etc: under reamed piles and mass concrete, complete all as specified and directed.
17M & L for RCCM-25 (Design mix) as in Columns, pillars, piers, posts and struts, roof landing etc, complete all as specified and directed.
18M&L RCC M-25 (Design mix) as in beams , cantilevers, bressmummers, lintels over 1.5 m span all as specified and directed.
19Material and labour for providing RCC M-25 (Design mix) as in chajja all as specified and directed.
20M&L RCC M-25 Design mix as in slab supported on walls, beams and columns in floors , roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
21M & L for formwork to sides of concrete foundations, footings, bases of columns plinth beams rough finished flat surface rough finished, complete all as specified and directed.
22M & L for Formwork to sides of pillars, posts, struts, piers, columns, and stanchions etc, complete all as specified and directed.
23Use and waste for formwork to sides and soffits of floor or roof beams, beam haunchings, girder,bressummers, lintels, cantilevers, shelves including supports, overhangs etc, complete all as specified and directed.
24Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works, not exceeding 200 mm thick (Horizontal or slopping) for rough finished flat surfaces of concreteall as specified and directed
25M & L Rendering 15 mm thick in cement and sand mortar (1:4) on fair faces of brick work or concrete surface of wall , surface finished even and smooth without using extra cement, complete all as specified and directed.
26M&L Rendring 15mm thick in cement mortar (1:6) on fair faces of brick/concrete surfaces finished even and smooth without using extra cement all as specified and directed.
27Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives
28Material and labour for 10 mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.(Note:-The unitrate includes for fixing and for bracing, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it. Unit Rate also includes for straightening where reinforcement is supplied in rolls/coils).
29All as per item No 28 here in before5 mm and over upto 10 mm dia as in stirrups, spacers and binders.(Note:-The unitrate includes for fixing and for bracing, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it. Unit Rate also includes for straightening where reinforcement is supplied in rolls/coils).
30M&L 75mm thick PCC (1:3:6) type C-2(40mm graded stone aggregate)as in plinth protection finished even and fair without using extra cement all as specified and directed.
31Material and labour for providing 40mm thick cement concrete (1:2:4) type B1using 20mm graded aggregate as in flooring finished even and smooth without using extra cement all as specified and directed.
32Material and labour for providing 100 mm thick cement concrete (1:3:6) type C2using 40 mm graded aggregate as in sub base of floor all as specified and directed.
33Material and labour for preparation of newsurfaces and applying two coats of distemper oil emulsion over a coat of primer on 3mm thick layer of wall care putty on wall complete all as specified and directed.
34S&F 2nd class hard wood for Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints, supplied and fixedcomplete all as specified.
35S&F 35mm thick, 2nd class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats complete all as spd all as specified and directed.
36S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors ; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165including portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. complete all as specified and directed.
37Supply and fix,rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, brances, etc, complete, drilled for fixing of steel sheeting or other covering,door etc to be prepared for hanging or sliding either and including either hook and hinges orsteel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging, also fastening and fixing complete all as specified and directed.
38S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed .
39S&F 3mm thick sheet glass, ordinary quality fixed with pin &glazing with oil putty in square n exc 0.50 sqm in each pane all as specified and directed.
40S & F 5.5mm thick Sheet glass,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed.
41Supply and fix, powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed .
42Supply and fix, powder coated anodised aluminium window and ventilator shutters, side hung type without sash bar, aluminium section weighing 0.55 kg/m includingnecessary jointing cleats,glazing clips, rubber packing anodised aluminium snap beadings, incl necessary aluminium cutting existing floor and making good distlurbed surfaces and necessary fittings such as peg stays, hinges type B-21, handle etc all as specified and directed.
43Supply and fix, powder coated anodised aluminium door shutters, side hung type without sash bar, aluminium section weighing 0.55 kg/m includingnecessary jointing cleats,glazing clips, rubber packing anodised aluminium snap beadings, incl necessary aluminium cutting existing floor and making good distlurbed surfaces and necessary fittings such as peg stays, hinges type B-21, handle etc all as specified and directed.
44S&F rotational moulded polythylene water storage tanks (cylindrical, vertical with closed top) hoisted and fixed in position of 1000 Ltr capacity all as specified in SSR part Iall as specified and directed.
45M & L for preparation of painting to new steel & iron surface of description, over 10 cm in width or girth and applyingtwo coat of synthetic enamel paint over one coat of red oxide, complete all as specified and directed.
46Supplied & fixed Steel windows with side hung shutters of approved manufacturer including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded completeas per approved manufacturer"s instruction.
47S & F 300mm length of aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
48Material and labour APP based polymeric membrane minimum weighing 3.0 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application complete all as specifiedlaid over a coat of bituminous primer @ 0.30 ltr /Sqm & finished withapplying bitumen grade 85/25 coat @ 1.2 Kg /Sqm. APP membrane shall be laid by torching with 75mm overlap in longitudinal direction and 150mm overlap in transverse direction all as directed and finished withapplying one coat of aluminium paint as directed by Engineer-in-Charge and laid as perspecification all as specified and directed.
49M&L forsand filling under floor with clean dry sand complete all as specified and as directed.
50M & L Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thick M-35 grade with grey cement and pigment all as specified and directed.
51M&L screed bed or bedding layer 15 mm thick in cement mortar (1:6) on floors for laying floor finish complete all as specified and as directed.
52S&F Solid PVC door frame of size 50mm x47mm made out of 5mm plain clour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing all as specified and directed.
53S&F factory made solid PanelPVCdoor shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails.MS frame shall be covered with heat moulded plain colour PVC channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and gap insert for top and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, all as per specification and drawing.
54Supply and fix, 100 mm long butt hinges, medium weight, and cold rolled mild steel all as specified and directed.
55S&F Aluminiumhandles, cast type,anodised of size 100mm all as specified and directed.
56S&F Aluminium , anodised, barrel tower bolts of extruded section and fixed of 125 mm length,all as spd all as specified and directed.
57M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and joint free in neat cement slurry and pointed in white or coloured cement to match and incl 15 mm th Screed bed for laying floor finishes in cm (1:6)s as directed at site all as specified and directed.
58M&L for not less than 450 x 350 x7 mm thick glazed ceramic tiles colored as in dado/skirting and vertical surfaces set&jointedin neat cement slurry and pointed in colored cement 0ver and incl10 mm thick cement mortar 1:4 to match theShade, pattern, laying etc of tiles as directed at site all as specified and directed.
59S & F 80mm bore steel water tube, "medium grade",galvanised, with all fitting and fixed laid in trenches complete all as specified and directed.
60S & F 50mm bore steel water tube, "medium grade",galvanised, with all fitting and fixed laid in trenches complete all as specified and directed.
61S & F 25mm bore steel water tube, "medium grade",galvanised, with all fitting and fixed laid in trenches complete all as specified and directed.
62S & F 15mm bore steel water tube, "medium grade",galvanised, with all fitting and fixed laid in trenches complete all as specified and directed.
63S & F 25mm bore steel water tube,"medium grade",galvanised, with all fitting and fixedto walls and ceilings or laid in floors complete all as specified and directed.
64S & F 20mm bore steel water tube,"medium grade",galvanised, with all fitting and fixedto walls and ceilings or laid in floors complete all as specified and directed.
65S & F 15mm bore steel water tube,"medium grade",galvanised, with all fitting and fixedto walls and ceilings or laid in floors complete all as specified and directed.
66Supply and fix stop valves, cast copper alloy,fancy type, chromium plated with long shank and cup (concealed type) for 15mm dia of pipe complete all as specifiedand directed.
67S&F Bib taps, cast copper alloy, chromium plated, fancy typescrewed down, high pressure, screwed for iron pipe or for brass ferrule of 15mm dia all as specified and directed.
68Supply and fix, 15 mm bore pillar tap,fancy type cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe or for brass ferrule all as specified and directed.
69Supply and fix,15 mm dia 450 mm long connection pipe with two PVC PTMT nuts at each ends with rubber washer complete all as specified and directed.
70S&FPVC valve less, syphonic action type flushing cistern, low level with inlet, ball valve float and handle including brackets of capacity 10 ltrs incl PVC connection wih brass nut on both ends and PVC flush pipeall as specified and directed.
71Supply and fix Vitreous China bowl urinal angle back of size 430 x 370 x 340 mm (minimum), with grating and union for discharge pipeincluding providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe all as specified and directed.
72Supply and fixed Vitreous China wash basin white flat back size 630x450 mmincludingbracket, cutting for and pinningthe ends of brackets or erecting stands also including brass chromium plated waste coupling 32mm dia,PVC flexiblewastepipe of adequate length and dia and PVC connection 15mm size 450 mm length with brass CP nuts on both sides, all as spd all as specified and directed.
73Supply and fix in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including seat coverwhite closed type complete all as specifiedand directed.
74S&F 600mmx450mmx6mm bevelled edge mirror mounted in 40mm wide PVC frame of approved size and colouron 6mm thick AC building board or commercial plywood and fixed to wooden plugswith chromiumplated brass screws and cup washers complete all as specified and directed.
75S & Ffor sheetglass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracked guard and railing 60cm long complete all as directed.
76S & F soap dish, chromium plated, approximate size 160 x160x90 mm complete all as directed.
77S&F PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives fixed to walls with brackets etc of 110mm dia all as specified and directed.
78S&F PVC (SWR) bends/shoes any radius of 110mm dia all as specified and directed.
79S&F PVC (SWR) bends/shoes any radius of 75mm dia all as specified and directed.
80S&F Cast iron nahani trap 75 mm dia all as specified and directed.
81Supply and fix, PVC(SWR)gully trap 125/110 mm setting and jointing withsolvent cement all as specified and directed
82S&F 75 mm bore PVC (SWR) floor trap,plain withgrating including jointing to waste pipe, all as specified and directed.
83S&F gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of 50 mm dia completeall as specified and directed.
84S&F gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of 25 mm dia completeall as specified and directed.
85M&L cement concrete type B1 (1:2:4) (20mm graded stone aggregate) as in coping all as spd all as specified and directed.
86Supply and fixing GI protection pipe light grade for cable protection incl all fittings laid in trenches or fixed on pole all as specified for 50 mm dia complete all as specified and as directed.
87M & L for Construction of brick masonry Valve chamber of 60 cm x 60 cmx 60 cm [internal dimensions] suitable for 50mm/80 mm bore sluice valve with PCC [1:4:8] type D2 using 40 mm graded stone aggregate for foundationbrick wall with sub class ‘B’ brick, oldsize built in CM(1:6), PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MMthick including provision of MS sheet cover 3 mm thick with two coats of synthetic enamel paint over a coat ofred oxideprimer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified.
88M & L for Cutting, screwing existing steel tubing of size 50 or 80 mm for alterations or additions complete all as specified and as directed.
89Horizontal boring below pavement of road, in soft/lose soil for crossing 80 mm size G.I pipe lines including makingsurface good matching to the existing one or all as specified and directed.
90M&L forsand cushioning with clean dry sand for protection of under ground cable complete all as specified and as directed. Note :- Punned thickness of sand layer shall be measured and paid to contractor.
91Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core cpmplete all as specified and as directed.
92Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core cpmplete all as specified and as directed.
93Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core cpmplete all as specified and as directed.
94M&L for Best quality bricks locally available sub class "B" bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as directed.
95Supply, fixing, errecting in trully vertically position steel tubular swaged welded pole complete with cast iron base plate, finial taper plug, bolts, nuts, and screws as specified type 410 SP - 22 (8.5 mtr long) including one primer coat, one under coat, one finishing coat of aluminium paint, marking of pole numbers and making 3 Nos of black colour strip 30 cm wide on equal distance from coping including suitable size of PVC cable jointing box with nut bolts and MS clamps made out with 20 x 5 flat iron complete all as specified and as directed.
96Supply and fixing LED street light fittings on poles of capacity 45 watts, High pressure die cast aluminium, IP 66 Rating, front cover made of toughened Clear Glass, suitable for pole mounting with bracket arm 40mm dia, GI light grade pipe up to 1.4m long,bend to required shape, clamp 40mm x 6mm of required length including nuts & bolts fixed on street poles complete all as specified.
97Supply and fix Junction box with terminals of size 155 x 210 x 92mm or nearest higher size made of polycarbonate body with IP 66/67 degree of protection, dust proof, water tight, shock proof, fire retardant, with internally embedded gasket fitted with heat treated bakelite terminals block and PVC glands for cable entry complete all as directed.
98Supply , install, testing and commissioning of LT panel board outdoor type, CPRI approved, platform mounted factory made, totally enclosed dust and vermin proof openablefrom both front and rear side made out of 14 SWG (3.15 mm) thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paintover a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with copper strips of suitable size and necessary foundation workand comprisingfollowing:- (a) Copper Bus bar 250 A, 50 KA breaking capacity, IP 54, 04 Nos and accessories. (b) Incoming MCCB, 4 pole, 160 Amps, 415 Volt AC, 36 KA rupturing capacity --01 No. (c) Ougoing MCCB, 4 pole, 63 to 100 Amps, 415 Volt AC, 25 KA rupturing capacity --02Nos. (d) Outgoing MCB TPN 32 Amps, 10 kA, "C" series, 415 volts--02 Nos. (e) Time switches 415 V three Phase of 20 Amp rating with contactor--01 No. (f) Metering and accessories--01 Set withnecessary CTs.
99Supply , install, testing and commissioning of LT panel board outdoor type, CPRI approved, platform mounted factory made, totally enclosed dust and vermin proof openablefrom both front and rear side made out of 14 SWG (3.15 mm) thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paintover a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with copper strips of suitable size and necessary foundation workand comprisingfollowing:- (a) Aluminium Bus bar 250 A, 50 KA breaking capacity, IP 54, 04 Nos and accessories. (b) Incoming MCCB, 4 pole, 160 Amps, 415 Volt AC, 36 KA rupturing capacity --01 No.
100M & L for Point wiring in consealed conduit with 1.5 Sqmm PVC insulated and unsheatheed single core multi strandedcopperconductor ISI marked 1100 volts grade drawn through PVC conduit through walls (CONCEALED) for fixing of switches/sockets etc including 1.5 Sqmm PVC insulated unsheathedstranded copper conductor cable for earth continuity and connecting to common earth dolly complete all as specified and directed :-
101All as per item no 100 here in beforebutonelightpointcontrolled byoneswitch
102All as per item no 100 here in beforebutoneCeiling/Exhaust Fanpointcontrolledbyoneswtich
103All as per item no 100 here in beforebutonesocketpoint5Ampsontheindependentboard
104All as per item no 100 here in beforebutonesocketpoint5Amps on same board
105All as per item no 100 here in beforebut for One 5 pin multi, socket outlet, 15 Amps , independent, with cables 2.5 Sq mm of size complete all as specified and directed.
106M &L Socket outlet 2 in 1, 3 pin, 5A complete all as specified and as directed.
107S & F Switch socket combination 2 in 1,5 pin 15 Amps 5 in 1flush type with fuse and neon indicator complete all as specified and as directed.
108S & F Switch socket combination 2 in 1,3 pin 5 Amps 5 in 1flush type with fuse and neon indicator complete all as specified and as directed.
109Supply & fix switch piano flush type single pole, one way 5 Amps complete all as specified and as directed.
110S &F ceiling rose 3 pole/PVC/polycarbonate isoloted body complete all as specified and as directed.
111S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet, 240 V complete all as specified and as directed.
112Supply & fix LED tube light Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver along with fixture, not less than 20 W complete all as specified and directed.
113Supply & fix LED tube light Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver along with fixture, not less than 10 W complete all as specified and directed.
114Supply and fix LED street light 25 W IP 65 complete all as specified and as directed.
115Supply and fixing sheet metal enclouser distribution board forMCCBsto befixed 415 volts, 4 ways IPdouble door with hinged vertical type having 200 rated copper bus bar with neutral link, complete all as specified and directed.
116Supply and fix Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 Volts complete all as specified and as directed.
117Supply and fix Triple poleand earth sheet metal encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amp, 415 Volt complete all as specified and as directed.
118Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as directed.
119Supply and fix MCB TP 6 to 32 Amp, 240 Volt complete all as specified and as directed.
120Supply and fix MCB SP 6 to 32 Amp, 240 Volt complete all as specified and as directed.
121Supply and fixing exhaust fan of size not less than 380 mm sweep heavy duty, copper wound, steel body with louver energy saving single phase, 230 volts, 50 HZs completeall connecting accessoriesincluding making suitable size of hole in brick wall to be fitted louver of fan and all electric connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose complete all as specified and directed.
122Supply and fix, 5 star rated regular, 33% power saving over conventional ceiling fans aesthetics stylish with metallic body ring and trims ceiling fan, 1200 mm sweep Ivoryas per manufacturer"s instruction complete all asdirected.
123M&L for submain wiring with two single core PVC insulatedunsheathed stranded copper conductor 4.0 sqmm (nominal area) drawing through PVC conduit pipe and 4.0 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly Note:- (i) 2 runs of 4.0 sqmm cable and 1 run of 4.0 sqmm single core copper cable and 1 run of non metalic PVC conduit pipe shall be measured as single run.
124M&L for submain wiring with four single core PVC insulatedunsheathed stranded copper conductor 4.0 sqmm (nominal area) drawing through PVC conduit pipe and 4.0 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly Note:- (i) 4 runs of 4.0 sqmm cable and 2 run of 4.0 sqmm single core copper cable and 1 run of non metalic PVC conduit pipe shall be measured as single run.
125M&L for earthing complete with GI earth plate electronic 600 x 600x 6mm buried directly in ground vertically to a depth of not less than 2.25 m below ground level with the top edge of earth plate at a depth of not less than 1.5 mtr below ground level connected to GI earth lead 4 mm dia by means of nuts bolts washers etc made out of galvanized iron and GI wire connected to main switch/DB board including necessary excavation and earth work PCC (1:3:6) type C1 using 20mm graded stone aggregate earth chamber 40mm thick RCC cover type B1 (1:2:4 ) B1 using 20mm graded stone aggregate 20mm dia GI medium grade protection pipe upto main switch board etc complete including testing all as shown in electrical plate No 3 of MES Schedule Part I.
126Material and labour for earthing complete with galvanised earth plate electrode 600 x 600 x 3.15 mm buried directly in ground vertical to a depth not less then 2.25 mtr below ground level with the top edge of earth plate at a depth of not less then 1.5 mtr below normal ground level using GI earth strip in size 32 x 6 mm connecting to test pointby means of nuts bolts and washers etc. made including necessary excavation earth work PCC (1:3:6) type C1 using 20 mm graded stone aggregateearth chamber 40 mm thick RCC cover with PCC (1:2:4) type B1 using 20 mm graded stone aggregate 20 mm dia GI medium grade watering pipe and 40 mm for strip, funnel, protection pipe,adequate quantity of common salt, charcoal etc. and connectingcomplete all as specified and shown in electrical plate No. 3 of MES Sch Part - 1 complete including testing all specified and directed.
127Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2. of capacity 1.5 TR complete all as specified and as directed.
128Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2. of capacity 2.0 TR complete all as specified and as directed.
129Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA complete all as specified and as directed.
130Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and as directed.
131Material and labour for single pointed air termination aluminum rod 12mm dia, 300 mm long complete all as dpecified and as directed.
132Material and labour for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed.
133Material and labour for copper strip 32 mm x 6 mm buried in ground or fixed to wall or drawn in pipe or any other indicated situation for loop earthing etc. as required.
134Material & labour for test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mmm long hex head screw including box all as directed.
135Supply and fixing GI pipe medium grade 32 mm dia with anchor plate 3 mm thick 50x50 mm welded at the bottom grouted on bed block including 3 mm thick MS cap complete with 12 mm bore drilled on the MS cap and fixing of one GI nut duly welded on the inner surface of the cap suitable for fixing of the air termination rod. Note: Bed block will be measured and paid seperately all directed.
136Material & Labour for precast PCC type C1 1:3:6 (nominal mix) using 20 mm stone aggregate bed block of size 300x300x450mm height for fixing GI pipe 32 mm dia medium grade with air termination rod vertically all as specified.
137Material & labour for earthing complete with copper plate 60cm × 60cm × 3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as directed.
138Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as direceted.
139Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.