| 1 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (make- armstrong/ anuton) |
| 2 | The hermetically selead doors having size 2.6 m x 2.1 mwith single sliding. The cantroler should be capableof being operted by elbow switch / foot switch as well as touch less sensor, the track should be of stainless steel/ aluminium & the runningthe surface for the top roller should be sutabile angled to reduce resistence to movement. the door leaf should be hung by means of hard plastice rollers of high quality with double bearingat the top. the roller should be provided under the stainless steel / aluminium track to enable smooth and noiseless movement. Opening and clossing of the door should be micro processor controlled electornically movement. Door material should be of HPL (High Pressure liminated board) , colour should match the interior and care should taken to make the leaf strong and light. the door should be able to open and close the door effortlessly in case of failure of automatic macanism. The door opening handle should be strong and material should be strong and well finiushed of material SS ( Glass funished) should be provided with high quality cylindrical lock. The door leaf should be high quality synthtic ruber gasket with long life to insure hermatic sealing (to maintain air puressure differential). the air tightness 99.99% at a pressure of 100 Pa the finushed door on either side of the door should be perfectlly level ( maxumampermissible differnce + 1mm).The overall thichness of the finushed door should be 55mm to 60 mm.The inner part of thedoor should be filled with CFC free polyurethane foam thickness of 48mm or nearby. ( sealed airtight to preventfurther ingress of any microbial organism). The door and controll should be comply IEE regulations. All motors should be DC burshless motor with essential isolicaion from mains. The door should be with visble window pen of size 300mmx 300mm with double glassed panels and hermetically selead. Door movement should have minimum nosie. The starting time after receiving the signale should be adjustable between 0.5 to 20sec. Doorcontroller should be CE marked, test certificate for hermetically selead door frame ( factory test certificate should be enclosed with the pre dispatch documents. ( make- dorma, tata , metflex or equivalent) |
| 3 | The hermetically selead doors having size 1.5 m x 2.1 mwith double sliding. The cantroler should be capableof being operted by elbow switch / foot switch as well as touch less sensor, the track should be of stainless steel/ aluminium & the runningthe surface for the top roller should be sutabile angled to reduce resistence to movement. the door leaf should be hung by means of hard plastice rollers of high quality with double bearingat the top. the roller should be provided under the stainless steel / aluminium track to enable smooth and noiseless movement. Opening and clossing of the door should be micro processor controlled electornically movement. Door material should be of HPL (High Pressure liminated board) , colour should match the interior and care should taken to make the leaf strong and light. the door should be able to open and close the door effortlessly in case of failure of automatic macanism.and each pannel should be of 750 mm width minimum or as per site requirement and the as per direction of engineer I/c. The door opening handle should be strong and material should be strong and well finiushed of material SS ( Glass funished) should be provided with high quality cylindrical lock. The door leaf should be high quality synthtic ruber gasket with long life to insure hermatic sealing (to maintain air puressure differential). the air tightness 99.99% at a pressure of 100 Pa the finushed door on either side of the door should be perfectlly level ( maxumampermissible differnce + 1mm).The overall thichness of the finushed door should be 55mm to 60 mm.The inner part of thedoor should be filled with CFC free polyurethane foam thickness of 48mm or nearby. ( sealed airtight to preventfurther ingress of any microbial organism). The door and controll should be comply IEE regulations. All motors should be DC burshless motor with essential isolicaion from mains. The door should be with visble window pen of size 300mmx 300mm with double glassed panels and hermetically selead. Door movement should have minimum nosie. The starting time after receiving the signale should be adjustable between 0.5 to 20sec. Doorcontroller should be CE marked, test certificate for hermetically selead door frame ( factory test certificate should be enclosed with the pre dispatch documents. ( make- dorma, tata , metflex or equivalent) |
| 4 | The hermetically selead doors having size 1.5 m x 2.1 mwith single sliding. The cantroler should be capableof being operted by elbow switch / foot switch as well as touch less sensor, the track should be of stainless steel/ aluminium & the runningthe surface for the top roller should be sutabile angled to reduce resistence to movement. the door leaf should be hung by means of hard plastice rollers of high quality with double bearingat the top. the roller should be provided under the stainless steel / aluminium track to enable smooth and noiseless movement. Opening and clossing of the door should be micro processor controlled electornically movement. Door material should be of HPL (High Pressure liminated board) , colour should match the interior and care should taken to make the leaf strong and light. the door should be able to open and close the door effortlessly in case of failure of automatic macanism. The door opening handle should be strong and material should be strong and well finiushed of material SS ( Glass funished) should be provided with high quality cylindrical lock. The door leaf should be high quality synthtic ruber gasket with long life to insure hermatic sealing (to maintain air puressure differential). the air tightness 99.99% at a pressure of 100 Pa the finushed door on either side of the door should be perfectlly level ( maxumampermissible differnce + 1mm).The overall thichness of the finushed door should be 55mm to 60 mm.The inner part of thedoor should be filled with CFC free polyurethane foam thickness of 48mm or nearby. ( sealed airtight to preventfurther ingress of any microbial organism). The door and controll should be comply IEE regulations. All motors should be DC burshless motor with essential isolicaion from mains. The door should be with visble window pen of size 300mmx 300mm with double glassed panels and hermetically selead. Door movement should have minimum nosie. The starting time after receiving the signale should be adjustable between 0.5 to 20sec. Doorcontroller should be CE marked, test certificate for hermetically selead door frame ( factory test certificate should be enclosed with the pre dispatch documents. ( make- dorma, tata , metflex or equivalent) |
| 5 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). |
| 6 | Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. |
| 7 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). |