Rural Development Local Bodies Closing in 0 days TDR #30121246

Supply And Installation Of Dg Set 25 Kv For Mc Office In Palwal ( Retender ) Supply And Installation Of Dg Set 25 Kv For Mc Office In Palwal ( Retnder ) , Civil Work , Supply, Installation, Testing And Commissioning Of Load Bank With Digital Meter

Issued by Local Bodies · M C PALWAL, Haryana
Tender Value
5.43 Lakhs
Estimated cost
Bid Submission
09 Dec 2021
0 days left
EMD
11000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
M C PALWAL → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply And Installation Of Dg Set 25 Kv For Mc Office In Palwal ( Retender ) Supply And Installation Of Dg Set 25 Kv For Mc Office In Palwal ( Retnder ) , Civil Work , Supply, Installation, Testing And Commissioning Of Load Bank With Digital Meter Module Cost Of Digital Amp. I Volt Meter With Selector Switch Wiring ( But Exluding Cost Of Incoming And Outgoing Mccbs ) Etc.Suitable For Operation Of 240 / 415 Volts Ac. Supply With Both Side Cable Allay, Inter Connection And Fixing The Same In Existing Ms Pedestal / Wall Complete With All Labour And Material Required For The Same Up To The Entire Satisfaction Of Engineer-In-Charge Of Work.23.24.4.2 Load Bank 8 Way 250 Am , New Hsr 23.27.1Supply And Erection Of Godrej Almirah Typem.S. Pedestal Made Of 50 Mm X 50 Mm X 6 Mm Angle Iron Frame With 3.00 Mm Thick M.S. Sheet Covering Including Shutters With Suitable Hinges And Locking Arrangement With Godrej Type Handle Including Round Bars. The Top Covering Should Have Downward Overhang Of 75 Mm On All Sides Of Pedestal, Having Two Sets Of Water Proof Ventilation Holes Of Suitable Size On The Sides , At Top And Bottom , Each Set Containing Four Nos. Holes To Discharge The Heat Produced By The Current. The Shutters Fixed With Rubber Gasket Of Superior Quality And Of Suitable Size To Make It Water Proof . The Pedestal Duly Painted Both Inside And Outside With Two Coats Of Approved Paint And Primary Coat And Its Legs Are Embeded Upto The Entire Depth In 1 :2:4 Cement Concrete Block , Projected 75 Mm All Around The Pedestal And And 200 Mm Above The Ground Level Including The Cost Of All Labour And Material Required To Complete The Job In All Respect Upto The Entire Satisfaction Of The Engineer In-Charge Of The Work:Supply And Erection Of Godrej Almirah Typem.S. Pedestal Made Of 50 Mm X 50 Mm X 6 Mm Angle Iron Frame With 3.00 Mm Thick M.S. Sheet Covering Including Shutters With Suitable Hinges And Locking Arrangement With Godrej Type Handle Including Round Bars. The Top Covering Should Have Downward Overhang Of 75 Mm On All Sides Of Pedestal , Having Two Sets Of Water Proof Ventilation Holes Of Suitable Size On The Sides , At Top And Bottom , Each Set Containing Four Nos. Holes To Discharge The Heat Produced By The Current. The Shutters Fixed With Rubber Gasket Of Superior Quality And Of Suitable Size To Make It Water Proof . The Pedestal Duly Painted Both Inside And Outside With Two Coats Of Approved Paint And Primary Coat And Its Legs Are Embeded Upto The Entire Depth In 1 :2:4 Cement Concrete Block , Projected 75 Mm All Around The Pedestal And And 200 Mm Above The Ground Level Including The Cost Of All Labour And Material Required To Complete The Job In All Respect Upto The Entire Satisfaction Of The Engineer In-Charge Of The Work: M.S. Pedestal Of Size 600 Mm Wide , 750 Mm High , 300 Mm Deep And Each 5436 Bottom Totally Open , Duly Embeded In 1 :2:4 Cement Concrete Block Of Size 750 Mm X 450 Mm X 200 Mm Above Ground Level , Having A Base Of Size 900 Mm X 600 Mm X 250 Mm Below Ground Level. , New Hsr 24.2.2.3Laying Of Underground Cable 0. 75 Metre Below Ground Level Covered With Sand And Bricks Including Excavation And Refilling Of Trenches.:-16 Sq Mm To 35 Sqmm 2 To 4 Core 50 Sq Mm To 150 Sqmm 2 To 4 Cor , New Hsr 24.7.1 Providing Rcc Foundation Of M20 Grade ( 1 Cement:1.5 Stone Aggregate: 3 Coarse Sand ) I / C Excavation, Steel Reinforcement ( Fe 500 ) @ 50 Kg / Cum Of Concrete Contents, Concrete Cover 50Mm, Over A Bed Of 75Mm Thick Pcc 1:5:10, Of Required Dimensions As Per Oem Recommendations To Provide Levelled Surface For Placement Of The Dg Set Complete In All Respects And As Per Directions Of Engineer-In-Charge ( Size Of Foundation Assumed = 5.0X1 .Bx1 .Om ) 30 To 40 Kva Dg Set , New Hsr 20.89 -3 --Designing, Supply & Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 + ( - ) 1% Volts Ac Alternator Coupled Directly Through A Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over / Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover / Standard Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover / Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specifications And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. +A ) Diesel Engine B ) Alternator C ) Battery 24 V. D ) Base Plate. E ) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Metres. F ) Tools, Standard Panel G ) Metering Set 415 Vac-1 Set ( Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, Cts ) H ) Metering Set 60 / 5A / 11 Ov ( Amp. Meter, Volt Meter ) I ) Overload Protection For Dc-1 No. J ) Battery Charger 24V Dc K ) Copper Bus Bar Of Suitable Size I ) Kwh Meter 96 Sqmm Size M ) Starting Fuse Button And Key Switch9on / Off ) N ) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, De Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 25 Kv , Sitc Four Pole On Load Manual Change Over Switch In Ss Enclosure Of Hsr23.22.8.2 100 Amp 415 Volt

BOQ

Name of Work:Supply and installation of dg set 25 kv for MC Office in Palwal
Sl. No. Item Description
1CIVIL WORK
2Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. I volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCB\"s ) etc.suitable for operation of 240/415 volts AC. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work.23.24.4.2 Load Bank 8 way 250 am
3new hsr 23.27.1Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars. The top covering should have downward overhang of 75 mm on all sides of pedestal, having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current. The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1 :2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in-charge of the work:Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars. The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current. The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1 :2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in-charge of the work: M.S. pedestal of size 600 mm wide , 750 mm high ,300 mm deep and each 5436 bottom totally open , duly embeded in 1 :2:4 cement concrete block of size 750 mm x 450 mm x 200 mm above ground level , having a base of size900 mm x 600 mm x 250 mm below ground level.
4New HSR 24.2.2.3Laying of underground cable 0. 75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:-16 Sq mm to 35 sqmm 2 to 4 Core 50 Sq mm to 150 sqmm 2 to 4 Cor
5new hsr 24.7.1 Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarsesand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents,concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensionsas per OEM recommendations to provide levelled surface for placement of the DG setcomplete in all respects and as per directions of Engineer-in-charge(Size of foundation assumed = 5.0x1 .Bx1 .Om)30 to 40 KVA DG Set
6new hsr 20.89 -3 --Designing, Supply & erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. +a) Diesel Engineb) Alternatorc) Battery 24 v.d) Base Plate.e) suitable sq mm suitable core copper cable upto 40 metres.f) Tools, standard panelg) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator,control fuse, frequency meter, CT\"s)h) Metering set 60/5A/11 OV (Amp. Meter, Volt Meter)i) Overload protection for DC-1 No.j) Battery Charger 24V DCk)Copper bus bar of suitable sizeI) KWH meter 96 sqmm sizem) Starting fuse button and key switch9on/off)n) Indicating lamps for low lubricated oil pressure, high coolant temperature, setrunning, load on, De control and other required accessories complete in all respectsto the satisfaction of Engineer-in-charge 25 kv
7SITC Four pole ON LOAD Manual change over switch in SS enclosure of hsr23.22.8.2 100 amp 415 volt

AI Tender Summary

OUR REF NO 30121246
AUTHORITY Local Bodies
TENDER VALUE 5.43 Lakhs
LAST DATE 09-12-2021
Authority
Authority Name Urban Local Bodies
Work Description Supply And Installation Of Dg Set 25 Kv For Mc Office In Palwal ( Retender ) Supply And Installation Of Dg Set 25 Kv For Mc Office In Palwal ( Retnder ) , Civil Work , Supply, Installation, Testing And Commissioning Of Load Bank With Digital Meter Module Cost Of Digital Amp. I Volt Meter With Selector Switch Wiring ( But Exluding Cost Of Incoming And Outgoing Mccbs ) Etc.Suitable For Operation Of 240 / 415 Volts Ac. Supply With Both Side Cable Allay, Inter Connection And Fixing The Same In Existing Ms Pedestal / Wall Complete With All Labour And Material Required For The Same Up To The Entire Satisfaction Of Engineer-In-Charge Of Work.23.24.4.2 Load Bank 8 Way 250 Am , New Hsr 23.27.1Supply And Erection Of Godrej Almirah Typem.S. Pedestal Made Of 50 Mm X 50 Mm X 6 Mm Angle Iron Frame With 3.00 Mm Thick M.S. Sheet Covering Including Shutters With Suitable Hinges And Locking Arrangement With Godrej Type Handle Including Round Bars. The Top Covering Should Have Downward Overhang Of 75 Mm On All Sides Of Pedestal, Having Two Sets Of Water Proof Ventilation Holes Of Suitable Size On The Sides , At Top And Bottom , Each Set Containing Four Nos. Holes To Discharge The Heat Produced By The Current. The Shutters Fixed With Rubber Gasket Of Superior Quality And Of Suitable Size To Make It Water Proof . The Pedestal Duly Painted Both Inside And Outside With Two Coats Of Approved Paint And Primary Coat And Its Legs Are Embeded Upto The Entire Depth In 1 :2:4 Cement Concrete Block , Projected 75 Mm All Around The Pedestal And And 200 Mm Above The Ground Level Including The Cost Of All Labour And Material Required To Complete The Job In All Respect Upto The Entire Satisfaction Of The Engineer In-Charge Of The Work:Supply And Erection Of Godrej Almirah Typem.S. Pedestal Made Of 50 Mm X 50 Mm X 6 Mm Angle Iron Frame With 3.00 Mm Thick M.S. Sheet Covering Including Shutters With Suitable Hinges And Locking Arrangement With Godrej Type Handle Including Round Bars. The Top Covering Should Have Downward Overhang Of 75 Mm On All Sides Of Pedestal , Having Two Sets Of Water Proof Ventilation Holes Of Suitable Size On The Sides , At Top And Bottom , Each Set Containing Four Nos. Holes To Discharge The Heat Produced By The Current. The Shutters Fixed With Rubber Gasket Of Superior Quality And Of Suitable Size To Make It Water Proof . The Pedestal Duly Painted Both Inside And Outside With Two Coats Of Approved Paint And Primary Coat And Its Legs Are Embeded Upto The Entire Depth In 1 :2:4 Cement Concrete Block , Projected 75 Mm All Around The Pedestal And And 200 Mm Above The Ground Level Including The Cost Of All Labour And Material Required To Complete The Job In All Respect Upto The Entire Satisfaction Of The Engineer In-Charge Of The Work: M.S. Pedestal Of Size 600 Mm Wide , 750 Mm High , 300 Mm Deep And Each 5436 Bottom Totally Open , Duly Embeded In 1 :2:4 Cement Concrete Block Of Size 750 Mm X 450 Mm X 200 Mm Above Ground Level , Having A Base Of Size 900 Mm X 600 Mm X 250 Mm Below Ground Level. , New Hsr 24.2.2.3Laying Of Underground Cable 0. 75 Metre Below Ground Level Covered With Sand And Bricks Including Excavation And Refilling Of Trenches.:-16 Sq Mm To 35 Sqmm 2 To 4 Core 50 Sq Mm To 150 Sqmm 2 To 4 Cor , New Hsr 24.7.1 Providing Rcc Foundation Of M20 Grade ( 1 Cement:1.5 Stone Aggregate: 3 Coarse Sand ) I / C Excavation, Steel Reinforcement ( Fe 500 ) @ 50 Kg / Cum Of Concrete Contents, Concrete Cover 50Mm, Over A Bed Of 75Mm Thick Pcc 1:5:10, Of Required Dimensions As Per Oem Recommendations To Provide Levelled Surface For Placement Of The Dg Set Complete In All Respects And As Per Directions Of Engineer-In-Charge ( Size Of Foundation Assumed = 5.0X1 .Bx1 .Om ) 30 To 40 Kva Dg Set , New Hsr 20.89 -3 --Designing, Supply & Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 + ( - ) 1% Volts Ac Alternator Coupled Directly Through A Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over / Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover / Standard Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover / Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specifications And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. +A ) Diesel Engine B ) Alternator C ) Battery 24 V. D ) Base Plate. E ) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Metres. F ) Tools, Standard Panel G ) Metering Set 415 Vac-1 Set ( Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, Cts ) H ) Metering Set 60 / 5A / 11 Ov ( Amp. Meter, Volt Meter ) I ) Overload Protection For Dc-1 No. J ) Battery Charger 24V Dc K ) Copper Bus Bar Of Suitable Size I ) Kwh Meter 96 Sqmm Size M ) Starting Fuse Button And Key Switch9on / Off ) N ) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, De Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 25 Kv , Sitc Four Pole On Load Manual Change Over Switch In Ss Enclosure Of Hsr23.22.8.2 100 Amp 415 Volt
Basic Detail
Tender No PAL00720210831131118
Bidding Type Tender
Location
City M C PALWAL
State Haryana
Key Dates
Publish Date 02 Dec 2021
Submission Date 09 Dec 2021
Open Date 09 Dec 2021
Finance
Tender Value 5.43 Lakhs
Tender Fee 500
EMD 11000
Exemption Not Available
Document List
84a4bfec-97e2-4169-9d0c-6c7c6f4f9607.html
BOQ_261474.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 02, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 09, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

84a4bfec-97e2-4169-9d0c-6c7c6f4f9607.html

xls

BOQ_261474.xls

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders