| 1 | Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. |
| 2 | Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge. |
| 3 | Cement concrete (1:4:8) with 4cm size h.g.c.b. metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge. |
| 4 | Cement concrete (1:2:4) with 12mm size black h.g.c.b.chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge. |
| 5 | Dismantling of Lime concrete, cement concrete Grade M 10 from road crossing and existing civil structures and removing the debrises from the worksite etc complete. |
| 6 | R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 7 | Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge. |
| 8 | M.S. reinforcement for R.C.C. work including supplying, cutting, bending, binding & tying the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Still Bar (FE 415/ FE 500) |
| 9 | Brick work with Fly Ash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge. |
| 10 | 12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 11 | Filling the foundation and plinth with excavated material as directed by the Engineer-incharge. |
| 12 | White washing 3 coat with approve good stone lime including cost conveyance charges of materials including supply of labour, gum, indigo etc. required for the work complete as directed by the Engineer-incharge. |
| 13 | Labour charges for writting of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge. |
| 14 | Fitting of un-plasticised 200mm diaPVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge. |
| 15 | Supply of solvent cement of approve quality for joiniting of PVC Pipe with all cost and all tax etc. complete as per the direction of the Engineer-incharge. |
| 16 | Labour charges for Installation and delivery fitting including fitting of Sluice Valve, NR Valve, Air Release Valve, PVC Tee and lowering of pump and transportation etc complete. & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding etc. complete as per the direction of the Engineer-incharge. |
| 17 | Fabrication of special joint including cutting, welding of pipes, one end with other end suitable for connection to delivery pipeline of pumpset including cost of cutting, welding materials, and fitting it in proper alignment with delivery pipeline works,cutting & threading of pipe line etc. |
| 18 | Labour charges for connection of main switch to starter and starter to motor with connection ofother electrical fittings etc. complete as per direction of the Engineer-incharge. |
| 19 | Cost of 10HP Submerssible pump set total head of 20 Mtrs capable to discharge 1700 LPM withsquirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class \"F\" insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC Power Supply suction delivery= 100mmx100mm with BEE Star rated energy efficiency pump |& as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares. |
| 20 | Cost of 15HP Automatic Star delta Starter, sheetsteel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp &no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. |
| 21 | Cost of 63 Amp. Main Switch Triple pole & natural of voltage range 440 volt of re-wirable fuse and shall confirming to IS-4064(PT-I& ) with ISI markincluding all taxes etc. |
| 22 | Cost of 3 Phase Energy Meter tested by DISTCO. |
| 23 | Cost of Empty Irrigation Panel Board made out of 18 gauge CR Sheet with locking arrangements. |
| 24 | Cost of 4 KVR Power shunt capacitor including all taxes and royalities etc. |
| 25 | Cost of 2.5sqmm x 3 core Flat Cable for use in Tube well etc complete. |
| 26 | Cost of 100mm. dia nominal bore G.I.pipe having wall thickness 4.5mm.Elecrical resistance welded.Medium class confirming to IS 1239(Pt-1/2004) with socketed at one end the otherend protected with plastic thread protector.The socket confirming to IS-1239 ( pt-I/1992) with latest amendmewnts in random length of 4 to7 mtrs. Each pipe should bear ISI Certfication & manufacturers name/Trade mark including all taxes etc. with guarantee. |
| 27 | Cost of 150mm. dia nominal bore G.I.pipe having wall thickness 4.5mm.Elecrical resistance welded.Medium class confirming to IS 1239(Pt-1/2004) with socketed at one end the otherend protected with plastic thread protector.The socket confirming to IS-1239 ( pt-I/1992) with latest amendmewnts in random length of 4 to7 mtrs. Each pipe should bear ISI Certfication & manufacturers name/Trade mark including all taxes etc. with guarantee. |
| 28 | Cost of 200mm dia M.S. pipe with plain ends in random length of 4 to 7 mtrs. Confirming to BIS 3589 with minimum wall thickness of pipe should be 5.5mm & each pipe should bear ISI specifications & manufactures name/ Trade mark. Steel grade of pipe shoud be Fe-330. |
| 29 | Cost of 100mm dia G.I. Bend confirming to IS-1239(Pt-II 1992) including all taxes etc. |
| 30 | Cost of 100mm dia G.I.Flange confirming to IS-6392/1971 including all taxes etc. |
| 31 | Cost of 150mm dia G.I.Flange confirming to IS-6392/1971 including all taxes etc. |
| 32 | Cost of C I double flanged 200mm Sluice ValveFlanged type PN - 1.0 as per IS:5312 part-I with by-passarrangement |
| 33 | Cost of 100mm CI double flanged Non-Return Valve swing type PN-1.0 as per IS:5312 part-I with by pass arrangement. |
| 34 | Cost of 50mm dia Air release valve with saddle &Raiser pipe.The air release valve shall confirm to IS14845 with ISImark including all taxes &royality etc. |
| 35 | Cost of 200mm dia M.S.Flange |
| 36 | Supply of 200mm dia unplasticised riged UPVCpipe ivory in colour having specific gravity of 1.40 to1.46 gms/cc of straight length of 6(six) meter for portable water supplies conforming to IS-4985/2000 of BIS-Amendment-2 read with Table-1 of IS-specification bearingISImarks for working pressure CI-I UPVC pipe to withstand pressure of 2.5kgf/sqcm& the specification and manufacture name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transporation to work site in complete shape and handed over to Pani Panchayat President or Secretary. |
| 37 | Cost of 200mm dia PVCBend ( 90* W.P. 10 Kgf/cm2 ) conforming to IS - 4995/ 1988 with latest ammendment. |
| 38 | Cost of 200 mm x 200 mm x 200 mm Ø PVC Equal Tee(W.P. 4 kgf/cm2) confirming to IS-4995/1988 with latest ammendment |
| 39 | 200mm dia PVC Flange with Socket |
| 40 | Cost of200 mmØ PVC End Cap( W.P. 10 Kgf/cm2 ) conforming to IS - 4995/ 1988 with latest ammendment. |
| 41 | Cost of 100 mmx 150 mm G.I/M.S. Reducer |
| 42 | Cost of 150 mmx 200 mm G.I/M.S. Reducer |
| 43 | Cost of Laying & Fittings of 219mm dia M.S.Pipe |
| 44 | Cost of Laying & Fittings of 150mm dia G.I..Pipe |
| 45 | Cost of 200 mmØ PVCCoupler(4 Kgf/cm2 agricultural PVC fitting ) conforming to IS - 4995/ 1988 with latest ammendment. |
| 46 | Cost of 200mm x 200mmx110mm dia MS Tee with control arrangements. |
| 47 | Electrical Earthing including all materials as per the direction of the Engineer- incharge |
| 48 | Foundation Nut and Bolt, Rubber Insertion etc |
| 49 | Construction anderection of 11 /0.4 KV ,63 KVA Double Pole mounted Substation Star rated confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm M.S.Channel, Transformer belting on 2.80 M long 50 X 50 X 5 mm M.S.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75 X 40 X 6 mm M.S.Channel and supported by 1.0 M long 50 X 50 X 5 mm M.S.Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for25 KVA S/S, G.I.pipe earthingwith 25X5mm G.I.Flatsincluding cost of 25 KVA 11/0.4 K.V.Transformer , 35 Sqmm 3 1/2 Core PVC Cable - 40 mtr couping & padding of Poles, Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets, barbed fencing ( size (15\"x10\") with constn. of retaining wall, erection of RCC fencing post , sand filling and metal spreading ,fixing of iron grill gate etc as per cesu specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning. |
| 50 | Construction of 3 phase 11 KV line DP with A.B.switch arrangements-1no including cost of all materials, labour transportation,inspection & commissioning etc. complete. |
| 51 | Consturction of 3 Phase L.T.line as per REC standard confirming to RE rule 1956 with 200Kg BM long PSC pole support in 0.40M span with 3x35mm² +1x25 mm ² LT x LPE AB cable with coil earthing device, LT dead end clam, Suspension clamp with I hook , stay accessories such as wire insulator , clamp etc. nut bolts, alonwith concreting of poles and stay as per direction of Engineer in Charge. |