Repair Maintenance Of External Water Supply And Electricity , Dg Sets, Pump And Water Treatment Plant And Street Lights, Security Lights Etc And Summer And Cooling Appliances And Re-Wiring At Several Bldgs At Aizawl Under Ge Silchar Repair Maintenance , AIZAWL-Mizoram

Military Engineer Services-MES has published Repair Maintenance Of External Water Supply And Electricity , Dg Sets, Pump And Water Treatment Plant And Street Lights, Security Lights Etc And Summer And Cooling Appliances And Re-Wiring At Several Bldgs At Aizawl Under Ge Silchar Repair Maintenance . Submission Date for this Tender is 27-12-2021. Electrification Work Tenders in AIZAWL Mizoram. Bidders can get complete Tender details and download the document.




Tender Notice

30114097
Corrigendum : Repair Maintenance Of External Water Supply And Electricity , Dg Sets, Pump And Water Treatment Plant And Street Lights, Security Lights Etc And Summer And Cooling Appliances And Re-Wiring At Several Bldgs At Aizawl Under Ge Silchar Repair Maintenance
Open Tender
Indian
Mizoram
AIZAWL
27-12-2021

Tender Details

Repair Maintenance Of External Water Supply And Electricity , Dg Sets, Pump And Water Treatment Plant And Street Lights, Security Lights Etc And Summer And Cooling Appliances And Re-Wiring At Several Bldgs At Aizawl Under Ge Silchar Repair Maintenance Of External Water Supply And Electricity , Dg Sets, Pump And Water Treatment Plant And Street Lights, Security Lights Etc And Summer And Cooling Appliances And Re-Wiring At Several Bldgs At Aizawl Under Ge Silchar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Dec-2021 Revised BOQ BOQ 22-12-2021
2 13-Dec-2021 AMENDMENT IN TENDER DOCUMENTS Other 22-12-2021
3 13-Dec-2021 AMENDMENT IN CONTENT PAGE, NIT AND TENDER DOCUMENTS Other 22-12-2021
4 17-Dec-2021 change in critical dates Date 27-12-2021
5 17-Dec-2021 REVISED BOQ BOQ 27-12-2021
6 20-Dec-2021 CHANGE IN CRITICAL DATES Date 27-12-2021
7 20-Dec-2021 REVIISED BOQ BOQ 27-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 78900.0 /-
Tender Value
INR 39.43 Lakhs /-

BOQ Items

REPAIR/MAINTENANCE OF EXTERNAL WATER SUPPLY AND ELECTRICITY, DG SETS, PUMP AND WATER TREATMENT PLANT AND STREET LIGHTS, SECURITY LIGHTS ETC AND SUMMER AND COOLING APPLIANCES AND RE-WIRING AT SEVERAL BLDGS AT AIZAWL UNDER GE SILCHAR.
Sl. No. Item Description
1Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.5 metre in depth and getting out in hard/dense soil for errection of LT poles, laying of HT/LT UG cables, complete all as specified and directed.
2Returning, filling in with soil obtained from excavation including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard/dense soil, complete all as specified and directed.
3Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
4Taking down carefully copper/aluminum existing point wiring (light/fan/socket or power points) complete incl wooden battens/casing capping or conduit etc (without disturbing existing fittings point wiring etc) and all connected fittings such as switch, socket, ceiling rose, lamp holder, brackets ceiling fittings, bulk head fittings and fan regulator etc and making good to disturbed surfaces of wall floor etc complete all as specified and directed.
5Dismantling of old unserviceable main switches DBs, MCB enclosures, electric meter, PVC rectangular blocks etc and keeping in safe custody either for reuse or for disposal Including making good to the disturbed surface of wall complete all as specified and directed.
6M&L forPoint wiring using 1100 volt grade FRLSH PVC insulated unsheathed multi strand copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLSH PVC insulated unsheathed multi strand 1100 volt gradecopper conductorearth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box, connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etcfor one light/fan/bell point complete all as specified and directed.
7All as per item No.06 above but for5 Amps socket Point (Same board), complete all as specified and
8All as per item No.06above but for 5 Amps socket Point (Independent board), complete all as specified
9All as per item No. 06 here in beforebut for one three pin 15 Amps socket outlet on independent board with 1100V grade PVC insulated and unsheathed 2.5 Sqmm multi strand FRLSH copper conductor cable and PVC insulated and unsheathed copper conductor 2.5 Sqmm , 1100 volt grade as earth continuity conductordrawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box , connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etccomplete all as specified and directed.
10S & F switch piano, 5Amp single pole, flush type one way 230 volts complete all as specified and directed.
11S & F Socket outlet 2 in 1, 5 pin, 5 Amps flush type complete all as specified and directed.
12S & F Switch Socket combination outlet 2-in-1, 3pin 6/5 Amps flush type complete all as specified and directed .
13S & F Switch Socket combination outlet 2-in-1, 3pin 5 Amps & 3 pin 15 Ampflush type complete all as specified and directed .
14S&FBell push flush type 5 Amp, complete all as specified and directed.
15S & F stepped type electronic fan regulator flush type socket type complete all as specified and directed.
16S&F Modular switch 1 way 6A, 1 module fixed in repair, complete all as specified and directed.
17S&F Modular switch 1 way 16A, 1 module fixed in repair complete all as specified and directed.
18S&F Modular Bell push 6A 1 module fixed in repair complete all as specified and directed.
19Supply and fix Socket 6A - 5/6 pin combined 2 module fixed in repair complete with cover plate all as specified.
20Supply and fix Socket 6A/16Amp - 5/6 pin combined 2 modulefixed in repaircomplete with cover plate all as specified.
21Supply and fix Fan step regulator, 120W - 2 module fixed in repair complete with cover plate all as specified.
22S&F modular blank plate 01 module fixed in repair complete all as specified and directed.
23S&F modular Metal flush box alongwith 2 module White cover plate with frame fixed in repair,complete all as specified and directed.
24S&F modular Metal flush box alongwith 3 module White cover plate with frame fixed in repair,complete all as specified and directed.
25S&F modular Metal flush box alongwith 4 module White cover plate with frame fixed in repair,complete all as specified and directed.
26S&F modular Metal flush box alongwith 6 module White cover plate with frame fixed in repair,complete all as specified and directed.
27Supply and fixCeiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified anddirected
28S&F inBell ding dong type 6 amps 240 volts complete all as specified and directed.
29Taking downCeiling fan of any size/sweep for replacing bearing, bush includingrewinding after disconnecting the wire from existing ceiling rose and refixing the same after rewinding, minimum rewinding size 300 grade cleaning dust, oiling greasing, servicing and replacing bearing, gun metal bush, rubber reel with clamp and nut-bolt, washer, lock pin, excellation gear sytem, boby painting etc as existing including connecting flexible 3 core cable from ceiling rose to connector of fan completeall as specified and directed.
30S & F exhaust fan having PVC body of size 250 mm sweepAC single phase, 240 Volt of size with louvers connecting up including provision of fixing clamp, nut bolt and cable from ceiling rose or connector to fan, including taking down old UNSV plastic bodyfan completeall as specified and directed. Make: Bajaj Maxima DxI 250 mm White Dom Ex Fan
31Supply and fix sheet metal enclosure powder coated DB for fixing of MCBs, TPN 4 ways double door with 200 Amp rated bus bar, 415 Volts complete all as specified and directed.
32Supply and fix sheet metal enclosure powder coated DB for fixing of MCBs, SPN 8 ways double door with 200 Amp rated bus bar, 240 Volts complete all as specified and directed.
33Supply and fix sheet metal enclosure powder coated DB for fixing of MCBs, SPN 4 ways double door with 200 Amp rated bus bar, 240 Volts complete all as specified and directed.
34MCB TPN 63 Amp, C Curve type, 10KA,415 volts with over load and short circuit protection complete all as specified and directed.
35S&FMCB SP 6 to 32 Amp, C Curve type, 10kA, with over load and short circuit protection complete all as specified and directed.
36S&FMCB SPN 6 to 32 Amp, C Curve type, 10kA, with over load and short circuit protection complete all as specified and directed.
37M & L for sub main wiring with two single core 6 Sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC concealed conduit of suitable size with all fittings and fixing accessories on roof, walls, ceiling etc. including 1x 6 Sqmm PVC insulated unsheathedmulti strandcopper conductor earth wire FRLSH with proper colour coding connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including including taking down existing unserviceable one and removing from site complete all as specified and directed. Note:- Two run of single core cable and one run earth wire will be measured as one length.
38S&Flamp holder angular/batten/ Pendent insulated body with back plate for batten fittings, complete all as specified and directed.
39S&F for decorative bracket wall light fittings holder type made up of PVC/Polycarbonate suitable for 7 to 10 W LED lampone complete all as specified and directed.
40S&F of 7-10 W LED lamp/bulb suitable for lamp holder and decorative bracket wall light fittings, complete all as specified and directed.Make:- Havells Cat No. LHFOFWE1TZ1W012 or equivalent of Surya/Phillips/Bajaj/Crompton/Jaquar
41S&F LED light fitting 1x20Watt decorative box type with driver, holder including LED tube light/batten type connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose as applicable, complete all as specified and directed.
42S&F mirror light LED linear fitting including Tube rod 10 watts and fixed on wall surface with PVC square box for self aligning and connected with 3 core flexible FRLS copper cable PVC insulated of size 16/0.20 mm etc complete all as specified and directed.
43Supply and fix LED panel light size 2 x 2 designed by using latest technology, 36 watt, IP20 rating 180-220 volt cast colour for edge-lit ilumination, recess/surface mounted aesthetically designed for soft light and glare including accessories internally prewired suitable for surface ceiling/recessed mounting type including making connections with the existing supply complete all as specfied and directed.Make : HavellsCat Part No. ENDURASLIMPROPLUS2X2PLR28/36WLED840MOD or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/SSurya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
44Taking up and down steel tubing and connections, including cleaning for refixing or removal to store 80 mmbore pipe, complete all as specified and directed.
45All as per item no. 44 but of size 50 mm bore.
46All as per item no. 44 but of size 40 mm bore.
47All as per item no. 44 but of size 25 mm bore.
48All as per item no. 44 but of size 20 mm bore.
49Relaying & refixing old steel tube 80 mm bore after cleaning of all silts, dirts,mud,scaleswith new GI frittings and connection in new or old position with fittings in trenches/wall/floors, complete all as specified and directed.
50All as per item no. 49 but of size 50 mm bore.
51All as per item no. 49 but of size 40 mm bore.
52All as per item no. 49 but of size 25 mm bore.
53All as per item no. 49 but of size 20 mm bore.
54Supply and laying steel water tubing 80 mm bore of pipe, medium grade galvanised, ISI marked with all heavy duty fittings ISI marked laid in trenches/concealed wall/ceiling or laid in foors, complete all as specified and directed.
55All as per item no. 54 but of size 50 mm bore.
56All as per item no. 54 but of size 40 mm bore.
57All as per item no. 54 but of size 25 mm bore.
58All as per item no. 54 but of size 20 mm bore.
59Supply, installation and testing of Cast Iron Sluice valve, class PN 1.6, ISI marked conforming to IS-14846, complete suitable for 80 mm bore pipe with flanges ends duly drilled, brass spindle, CI gate with brass rings and iron wheel head , complete alkl as specified and directed.
60Supply and fix , as in repairs 50 mm bore Gun metal , globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed including dismantling the existing one, complete all as specified and directed.
61All as per item no. 60 but of size 40 mm bore Gate Valve.
62All as per item no. 60 but of size 25 mm bore Gate Valve.
63All as per item no. 60 but of size 20 mm bore Gate Valve.
64S&F PTMT ballvalves, high pressure, with polythene float Valves 25mmbore for GI pipes and all connected accessories including dismantling unserviceable valve and removing from site, complete all as specified and directed.
65All as per item no. 64 but of size 20 mm dia .
66M& L for supporting of pipe lines which is laying on ground level, brick work with sub class "B" old size bricks, straight or curved on plan exceeding 6 mtrs mean radius, built in CM 1:6 , complete all as specified and directed. Note: After preparing of bricks support, pipe will be fixed or locked with GI strip for pipe protection.
67Supply and fix PVC body Foot valve ISI mark of size 50-80 mm dia including taking out Unserviceable foot valve, complete all as specified and directed.
68M&L for Cleaning and removing all silt, dirt, mud, scales etc. from 50000 ltrs capacitysemi underground water storage sump by rubbing with brushes and throughly washing with bleaching powder and clean water complete includingwriting of date by preparing surface of size 45x30 cm and writing "TANK CLEANED ON DATE-MONTH-YEAR", complete all as specified and directed.
69All as per item No. 68 but 50000 ltrs PVC Tank/SMC Tank.
70All as per item No. 68 but 20000 ltrs Pressed steel Tank.
71All as per item No. 68 but 20000 ltrs Sedimentation Tank.
72All as per item No. 68 but 10000 ltrs RCC Tank.
73All as per item No. 68 but 5000 ltrs PVC Tank/SMC Tank.
74Material and labour for construction of valve pit of brick masonry of size 900 x900 x 900mm internal dimension complete with Angle Iron, 3.15mm thick MS sheet cover and locking arrangementincluding excavation and earth work and P.C.C1:3:6 type with provision of two coat of synthetic enamal paint over one coat of red oxide primer including demolition of existing valve pit, complete all as specified and directed.
75All as per item No. 74 butof size 750x750x750mm.
76All as per item No. 74 butof size 450x450x450mm.
77Material and labour for cutting of rusted MS sheet, cross arm, angle iron frame or tubular structure of pre-pressed steel OH tank at height of 3 to 11 mtrs replaced with new MS sheet, cross arm, angle iron frame or tubular stracture and welding the same at specified location to make to joint leak proof complete all as specified and directed.
78Supply and fix, fabricated with angle iron/sqaure bar/iron flats with MS hinge and latch for locking incl errection at proper position and applying two coats of synthetic enamel paint , complete all as specified and directed.
79M&L for steel work in tubular trusses for railing including welding, excavation, PCC, foundation for errection at proper position and applying two coats of synthetic enamel paint, complete all as specified and directed.
80M&L for preparation of surface by scrapping old painted surface and painting two coats of synthetic enamel paint on outer side of MS steel tank and sedimentation tank incl wiritng of water quantities, complete all as specified and directed.
81M&L for preparation of surface by scrapping old painted surface and painting one coat of bitumen paint or paint suitable for drinki9ng water tankon inside of MS steel tank 20,000 ltrs capacity, complete all as specified and directed.
82M&L for preparation of surface by scrapping old painted surface and finishing walls with Acrylic smooth exterior paint of required shade over RCC tank surface, complete all as specified and directed.
83Supply, Install, testing and commisioning of CPRI approved outdoor type LT feeder piller box of suitable size recommended by CPRI approved manufacturer cubical floor mounted type factory made totally enclosed, dust ad vermin proof made out of 3.00 mm thick MS sheet duly painted with powder coated both side in and out, having proper locking arrangment in both front and rear side aluminium bus bar of 200 amps ratingduly drilled holes for connections and mounted on epoxy based post insulatorsfor 3 phase, 4 wire, 500 volts, 50 HZ AC supply, hibling , cable entry boxes, cable gland incl iron angle frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I, complete all as specified and directed with the following:
84Incoming (a) MCCB 63 Amps, 4 pole, 25 KA, 415V - 01 Nos Outgoing (a) MCCB 32 Amps, 4 pole, 16 KA, 415V - 02 Nos (b) MCB TPN 63 Amps 10KA - 02 Nos (c) Contractor 3 pole 32 amp -01 Nos (d) Toggle switch 6 amp-01 Nos (e) Timer(analog) with battery backup-01 Nos (f) Overload relay 2/3.5A-01 Nos (g) Phase indicator lamps (RYB) set of 3 - 01 Set Note : (a) Excavation for grouting and PCC foundation for LT Panel shall be deemed incl in quated rate.
85Supply only Alumino Ferric( Ferric Alum) Grade -1 confirming to BIS 299-1984 (4th Version), complete all as specified and directed.
86Supply only Alumino Ferric( Ferric Alum) Grade -4 confirming to BIS 299-2012with additional requirements for purification of water, complete all as specified and directed.
87Supply only calcium based granular (calcium hypochlorite) disinfect for treatment of water, having chlorine content 65% to 70% in sealed drum (45 Kgs), complete all as specified and directed.
88Supply only of Poly aluminium chloride powder in 25 Kg bags conforming to IS-15573, complete all as specified and directed.
89Supply only bleaching powder of grade-1 confirming to IS-1065-1989 (2nd version) minimum markable chlorine 33.5% by mass packed in HDFC bag of 25 Kg capacity ISI marked, complete all as specified and directed.
90Supply only hydrated lime (eatable) Ca(OH)2 of purity 90%and conforming to IS-1514-1990(for water supply treatment), complete all as specified and directed.
91Supply only Non-Ferric Alum suitable for treatment for river water, complete all as specified and directed.
92Supply only Soda Ash suitable for treatment ofriver water , complete all as specified and directed.
93Supply only Polymer INDFLOC 238L suitable for treatment of river water, complete all as specified and directed.
94Taking out old unserviceable UG cables of any size from site, complete all as specified and directed.
95Supply and spread sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqdcover after punning down complete all as specified and directed. Note : Thickness of sand cushion after punning down will be measured and paid.
96Material and labour forlaying locally available sub-class "B" brick of size (old Size) laid flat and dryin trenches across the trench over the cable perpendiccular to the dirtection of cable for protection, complete all as specified and directed.
97Supply, fixing & testing of XLPE/PVC sheathed , armoured LT electric power cable (Heavy Duty) with aluminium conductor of size 95 Sqmm, 3.5 core 1100volts graded laid through duct/pipe/trench etc incl cable gland and lugs,complete all as specified and directed.
98All as per item No. 97 here in above but of size 70 Sqmm, 3.5 core.
99All as per item No. 97 here in above but of size 50 Sqmm, 3.5 core.
100All as per item No. 97 here in above but of size 25 Sqmm, 3.5 core.
101All as per item No. 97 here in above but of size 10 Sqmm,4 core.
102All as per item No. 97 here in above but of size 10 Sqmm,2 core.
103Supply and fix galvanised steel tubes of size 40 mm bore, light grade, with all fittingslaid to wall/ceiling/floor, complete all as specified and directed.
104Supply and fix galvanised steel tubes of size 80 mm bore, light grade, with all fittingslaid to wall/ceiling/floor, complete all as specified and directed.
105Material and labour for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (Over all length 9 metres long) confirming to IS-2713.Pole shall be painted with two coats of black bituminious paint throughout internally and externally up to planting depth, length from bottom and the remaining external protion shall be painted with two coats of aluminium paint over a coat ofred oxide primer andnumbering the pole with white paint alfa numaric letters on black patch fixed in repairs completeall as specified and directed. Note: Earthwork and PCC measured and paid separate Items.
106M&L for PCC 1:2:4 type B1 using 20 mm graded aggregate for coping the poles of any size, complete all as specified and directed.
107M&L for PCC 1:2:4 type B2 using 40 mm graded aggregate as in foundation, complete all as specified and directed.
108M&L for PCC 1:3:6 type C2 using 40 mm graded aggregate as in foundation, complete all as specified and directed.
109Supply and fix LED Solar street light fitting 35-40 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed. Make: Axxon/TATA Solcar/Bajaj/Havells/Crompton or equivalent.
110M&L for straight through joints (epoxy) including joint kits and labour complete for making joints suitable for 70-95 sqmm 3.5 core UG cables of the following sizes in joint kits, complete all as specified and directed.
111M&L for straight through joints (epoxy) including joint kits and labour complete for making joints suitable for 25-50 sqmm 3.5 core UG cables of the following sizes in joint kits, complete all as specified and directed.
112Supply, installation, testing and commissioning, CPRI approved factory made and tested, LT feeder pillar box, outdoor type of size 1000mm x 800mm x 300mm, CPRI approved, plateform mounted , the panel shall be dust and vermin proof, IP65 class protection and madeout of 3.15 mm thick CRCA MS Sheet and mounted on50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement, internal wiring with 2.5 sqmm PVC insulated, stranded copper conductor cable, IS-694 marked of adequate size and internal connection from MCCBs, MCBs and TPN aluminium bus bar and extension links of rating not less than 1.5 times the rated capacity of the respective MCCBs. The TPN bus bar and extension links shall be insulated with colour code heat shrinkable sleeve and shall be mounted epoxy regin insulator to contactor not less than 10 sqmm single core copper cable stranded copper conductor cable, IS-694 marked. The following items accommodated with this feeder pillar including 02 Nos danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white of size 25 x 20cm with letter figures and conventional skull bones in signal red colour and fixed nuts, bolts and washers etc with voltage and danger indicated in Hindi and English including taking down old rusted unsv feeder pillar, grouted by using PCC foundation 1:2:4 Type C1 with 20mm stone aggt, totally tested as per IEC 61439-1,complete all as specified and directed.
113The scope of work includes the following items accommodate the same panel:- Incoming (a) Load change over 32 Amps, 4 Pole, 415 V-01 Nos (b)MCCB 32 Amps, 4 Pole 10 KVA, 415 V-01 Nos OUTGOING (a) MCCB 125 Amps, 4 Pole , 16KA, 415 V-01 Nos (b) MCCB 100 Amps, 4 Pole , 16KA, 415 V-01 Nos (c) MCCB 63 Amps, 4 Pole , 16KA, 415 V-02 Nos (d) MCB TPN 63 Amps,4 Pole, 16 KA, 415 V-01Nos (e) MCB SPN 32 Amps, 10 KA, 415 V-03Nos (f) Digital multi function meter -01 Nos (g) Pahse indicator lamps (RYB) set of 3 -01 Set Note:-Excavation for grouting and PCC foundation for LT panel shall be deemed incl quoted rates.
114Supply, installation, testing and commissioning, CPRI approved factory made and tested, LT feeder pillar box, outdoor type of size 1000mm x 800mm x 300mm, CPRI approved, plateform mounted , the panel shall be dust and vermin proof, IP65 class protection and madeout of 3.15 mm thick CRCA MS Sheet and mounted on50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement, internal wiring with 2.5 sqmm PVC insulated, stranded copper conductor cable, IS-694 marked of adequate size and internal connection from MCCBs, MCBs and TPN aluminium bus bar and extension links of rating not less than 1.5 times the rated capacity of the respective MCCBs. The TPN bus bar and extension links shall be insulated with colour code heat shrinkable sleeve and shall be mounted epoxy regin insulator to contactor not less than 10 sqmm single core copper cable stranded copper conductor cable, IS-694 marked. The following items accommodated with this feeder pillar including 02 Nos danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white of size 25 x 20cm with letter figures and conventional skull bones in signal red colour and fixed nuts, bolts and washers etc with voltage and danger indicated in Hindi and English including taking down old rusted unsv feeder pillar, grouted by using PCC foundation 1:2:4 Type C1 with 20mm stone aggt, totally tested as per IEC 61439-1,complete all as specified and directed.
115The scope of work includes the following items accommodate the same panel:- Incoming (a)MCCB 100 Amps, 4 Pole, 36 KVA, 415 V-01 Nos OUTGOING (a) MCCB 63 Amps, 4 Pole , 16KA, 415 V-02Nos (c) MCCB 32 Amps, 4 Pole , 16KA, 415 V-02 Nos (d) MCB TPN 63 Amps,4 Pole, 16 KA, 415 V-01Nos (e) MCB SPN 32 Amps, 10 KA, 415 V-02Nos (f) Digital multi function meter -01 Nos (g) Pahse indicator lamps (RYB) set of 3 -01 Set Note:-Excavation for grouting and PCC foundation for LT panel shall be deemed incl quoted rates.
116Supply,install testing and commissioning CPRI approved outdoor Bus Bar Box of suitable size recoomended by CPRI approved manufacturer cubical floor mounted type factory made totally enclosed, dust and vermin proof made out of 3.00mm thuick MS sheet duly painted with powder coated both side in and out, having proper locking arrangement in both front and rear side aluminium bus barof 200 Amps rating duly drilled holes for connection and mounted on epoxy based post insulators for 3 phase, 415 Volts, 50 Hz AC supply, cable gland and iron angleframe (bottom portiuon of the panel), grouted byPCC foundation 1:2:4 type C1 with 20mm graded stone aggt totally tested as per IEC 64139-1, complete all as specifed and directed. Note:-Excavation for grouting and PCC foundation for LT panel shall be deemed incl quoted rates.
117M&L for shifting of LT panels from original position after disconnecting all electric connection distance not more than 50m including isntallation to ne w psoition and making allnecessary electric conmnection including PCC founndation and excavation, complete all as sepcified and directed.
118Material and labour for spray painting of transformers (any type power or distribution) of capacity upto and including 500 KVA ( in situ ) outdoor type, installed and located at different sites in scattered area under the AGE E/M Vairengte including the following: - (a) Preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete. (b) Painting with two coats of Duco paint (Grey) paint of approved make / quality all as directed at site. (c) Writing the SM MES No of transformer on MS body of transformer all as directed.
119Dehydration and filtration of existing transformer oil of transformer at different location with filtration machine and heating system to get the minimum di-electric strength of oil 50 KV minimum without disturbing the power supply system and refilling/ topping up /replacement of unserviceable transformer oil conforming IS-335-1993 complete all as specified and as directed. Note:- (a)Transformer oil required extra for filling/topping up shall be measured and paid separately under the relevant items of this schedule. (b) Cost of oil testing shall be deemed to be included in the unit rate quoted for this item and T&p Shall be aranged by contractor.
120Supply only new transformer oil of di-electric strength not be less than 60 KV and conforming to IS-335 of 1993 for filling/ topping up oil of transformer up to desired level complete all as specified.
121Supply and fix breather including silica gel, indicating type, 4 to 6 mm standard size of the particle, blue colour for transformer of capacity from 63KVA including removing of old breather complete all as specified.
122M&L in repairs for Danger Notice Plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional Skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 1100 Volts, 250mmx 200mm size, complete all as specified and directed.
123Dismantling of corroded/ rusted/defective cross arms of MS channel/angle of any section, complete all as specified and directed.
124Dismantling drop out expulsion fuse single pole complete all as specified and directed.
125Supply and fix drop out expulsion fuse unit suitable for 11KV of capacity up to 200 Amps mounted on MS channels complete with two post insulator 11KV including required hard ware like clamps nut bolts washers synthetic bonded fuse barrels etc all as specified.
126M&L for cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts,washers,welding, bending cold or hot, drilling holes for bolts, in any shape or sizes as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer, complete all as specified and directed.
127Dismantling of old UNSV air break gang operated switches, vertical/ horizontal, mounted on insulator/operating mechanism, complete all as specified and directed.
128M&L for triple pole, mechanically operated air break isolator (GOD),vertical mounting rotating type,mounted on insulator and steel frame, with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11KV grade with 9 insulators of rating upto200 amps, complete all as specified and directed.
129Dismantling of unserviceable insulators of any size/type complete all as specified and directed.
130S&F Disc type insulator, porcelain, vitreous, 155 mm high and 255mm dia ball and socket type, white, brown or green "Two in series" disc assembly including nuts, bolts as required for 11KV grade confirming to relevant IS, complete all as specified and directed.
131S&F as in repair for lightening arrester , expulsion type with all fittings, transmission class discharge capacity 65Kilo Amps suitable for 11KV, complete all as specified and directed.
132Material and labour for earthing complete with galvanised steel earth plate electrode600mmX60ommX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to Galvanised Iron strip 25 x 4 mm as earthing lead andprotected by 40 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR 2009 Part-I all as specified and directed.
133SF earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. , as required 25mmx4mm galvanised iron strip, complete all as specified and directed.
134Material and labour for servicing of Air conditoner Split/window type of capacity 1.5/2.0 ton split type in position or at workshop comprising of cleaning agent and water, tightening all electricals contacts, clips, bolts, nuts etc greasing/oiling blower motor assy, testing the serviceability of rubber bushes, connector, clips, bolts,nuts, washer etc, including checking the compressor unit and repalcing unserviceable spare parts etc., complete all as specified. Note:- (a) Spare parts shall be measured andpaid seperately for relevant items of schedule. (b) Gas charging and servicing will not be measured in complaint. (c) Transportation charges for original position to workshop & back and fixing charges deemed incl in quoted rate.
135Supply and fix in repair/repalcement of the following spare parts as per sample and suitable for 1.5 Ton split Air conditioner:-
136Starting CapacitorMFD.
137Running Capacitor of Capacity MFD.
138Thermostart switch with regulating knob unit incl necessary fittings and allied works.
139Selector Switch with Knob incl necessary fittings and allied works.
140Sealed unit compressor unitincl necessary fittings and allied works.
141Blower fan motor for outdoor unit incl necessary fittings and allied works.
142Blower fan motor for outdoor unitincl necessary fittings and allied works.
143Remote control hand set
144Remote control PCB circuit boardincl necessary fittings and allied works.
145Condensing coil Assembly incl necessary fittings and allied works such as clamps,nuts, bolts,soldering, bracing etc
146Copper tubing suction and dischargeline of suitable size 1/4", 5/8", 3/8" dia with heat stroke insulationincl necessary fittings and allied works.
147PVC drain pipeincl necessary fittings and allied works.
148PVC air filterincl necessary fittings and allied works.
149Material and labour for Gas Charging with suitable refrigerant R-22/R- 134A/R-32as filled in 1.5Ton split AC to get required back pressure and cooling to any make/model/capacity for water cooler including leak testing after and before Gas charging & make it leak proof, if any complete as specified and directed.
150M&L for servicing of refrigerator capacity upto 310 litres in position or at workshop comprising of cleaning, free from dust/cleaning the evaporator, condensorcoil with cleaning agent and water, tightening all electricals contacts, nuts, bolts,etc including hecking the compressor unit and replacing unserviceable parts, electric wire etc, complete all as specified and directed. Note:- (a) Spare parts shall be measured andpaid seperately for relevant items of schedule. (b) Gas charging and servicing will not be measured in complaint. (c) Transportation charges for original position to workshop & back and fixing charges deemed incl in quoted rate.
151Supply and fix in repair/repalcement of the following spare parts as per sample and suitable for refrigerator of any make/model:-
152Over load relay box for refrigerator of capacity 310 litrs including necessary fittings and allied works.
153Thermostart switch with regulating knob etc. for refrigerator of capacity 310 litrs including necessary fittings and allied works.
154Copper stainer and capacity tubefor refrigerator of capacity 310 litrs including necessary fittings and allied works.
155Condensing coil unitfor refrigerator of capacity 310 litrs including necessary fittings and allied works.
156PCB Unit including timerfor refrigerator of capacity 310 litrs including necessary fittings and allied works.
157Sealed unit compressor unit for refrigerator of capacity 165 to 210 litrs including necessary fittings and allied works.
158Sealed unit compressor unit for refrigerator of capacity 280 to 310 litrs including necessary fittings and allied works.
159Freezer unit with door for refrigerator of capacity 310 litrs including necessary fittings and allied works.
160Door lockwith duplicate keys for refrigerator of capacity 310 litrs including necessary fittings and allied works.
161Freezer door for refrigerator of capacity 310 ltrs
162Pigmy/cabin lamp including switch for refrigerator of capacity 310 litrs including necessary fittings and allied works.
163PVC ice Tray heavy duty for refrigerator of capacity 310 litrs including necessary fittings and allied works.
164PVC vegetable tray with glass cover for refrigerator of capacity 310 litrs including necessary fittings and allied works.
165Chiller tray for refrigerator of capacity 310 litrs including necessary fittings and allied works.
166Bottle supporterfor refrigerator of capacity 310 litrs including necessary fittings and allied works.
167Magnetic door rubber beading (main door gasket) for refrigerator of capacity 310 litrs including necessary fittings and allied works.
168Stainless steel door handle for refrigerator of capacity 310 litrs including necessary fittings and allied works.
169PVC drain tray for refrigerator of capacity 310 litrs including necessary fittings and allied works.
170Leg set of four for refrigerator of capacity 310 litrs including necessary fittings and allied works.
171Material and labour for Gas Charging of Refrigerator with Refrigerant R-22/R134-A/R-32 as filled in refrigerator of capacity 310 litresto get required back pressure and cooling effect complete all as specified and directed.
172M&L for painting of refrigerator of capacity upto 310 ltrs on site or at wortkshop complete all as specified and directed. Note:- (a) Preparation of old surfaces by cleaning, scrapping, rubbing/polishing etc complete. (b) Painting with two coats of synthetic enamel paint of make/colour directed by Engr-in-charge. (c) Cost of transportation and shifting of refrigerators shall be deemed inlcuding in quoted rate.
173S&F as in repairs for felxible cable PVC insulated copper condcuitor for 1100 volts of size 4 sqmm 3 core,
174S&F as in repairs for switch socket combination 3/5pin plug, 5/15 Amp, complete all as specified and directed.
175Maintenance and servicing to DG set of capacity 30KVA Kirloskar Oil Rngine including attending faults on call basis for normal repairs including repalcement of defective and worn out filters, gaskets, VB-belts, Engien oil, rubber hoses, worm drive clamps, nuts bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet setting if required and greasing of bearings of engines and alternator, checking of batteries, applying petroleum gel to battery terminals, adding distilled water, checking the oil, collent level at Vairengte/Lailapur/Bhaga and Aizwal, complete all as specified and directed. Notes:- (a) All items such as cleaning agent, cotton waste , grease, minor items such as washer, nuts, bolts etc required for carrying out the normal maintenance of the engine, mechanic charges and any specialised machine work from site workshop if required shall be demmed in quoted rates. (b) Fresh engine oil/spare parts for DG sets shall be supplied by the contractor as supply only and shall be measured and paid seperately under mentioned items in this BOQ. (c) During maintenance/ servicing of DG set, complet DG set shall be checked properly and all setting shall be doen propelyand rates to be deemed in quoted rates. (d) Servicing shall be carried out after every 500 Hrs run or after 6 months whicever is earlier.
176Taking out UNSV/repaireable parts from the engine 30KVA and supply/fixing of the following new spare parts including carrying out all related minor and periodical maintenance and overhauling wroks as per site requirement suitable for Kirloskar Oil Engine , complete all as specified and directed of the following:-
177Air Filter
178Lub Oil Filter
179Pre Filter
180Micro Filter
181Hose (water pump to radiator)
182V belt
183Fuel Pipe (0665410000)
184Fuel leak off pipe
185Fuel Pipe( 4H03105000)
186Fuel Pipe( 4H0310400)
187Set of joints
188Water temperature switch
189Set of O rings
190Set of copper washer
191OFF/ON Start switch
192Sensor unit for temoperature gauge
193Supply & fixing new Water pump assy complete set of 30KVA DG set including all accessories such as gasket, nuts bolts and washer etc to its original position, fixed in repair, complete all as specified and as directed .
194Supply & fixing new Dynamo Assy complete set of 30KVA DG set including all accessories such as nuts bolts and washer etc to its original position,fixed in repair complete all as specified and as directed.
195Repair the radiator fitted in 30 KVA capacity of DG sets and strip opening complete radiator assembly,for servicing mechanically and proper cleaning of tubes with using de-scaling solution,including repair of water tubes and top/ bottom tanks by soldering / gas welding of leakage of tubes/tanks. including replacement of gasket, nut bolts,etc ensuring perfectly leak proof after servicing of radiator,re-assembling and fixing the same in position and testing the system complete all as specified and directed . Notes :- (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. (ii) quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, gaskets/ packing etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation.
196Supply and filling Lube oil grade 10W 15 for DG set 30 KVA- 02 Nos , DG pump set, all as per requirement and directed . Make: Bharat petroleum/Indian Oil or equivalent as approved by GE.
197Supply only K-cool Super (Coolant) Part No. 82022035125 all as per requirement and directed. Make: Kirloskar/Cotton Greaves or equivalent as approved by GE.
198Supply and fix Diode (Positive and Negative) suitable for rotary rectifier of 30 KVAKirloskar alternator including taking out of unserviceable parts, completeall as per requirement and directed
199M&L for carrying out overhauling, caliberation from Authorised service centre, repalcement of damage sparte if any and refixing of 30KVA DG set, complete all as specified and directed.
200Supply and Fixingdigital/panel board type battery charger230V AC input 12V DC out put fixed in DG panel boardincl.all necessary cable connections complete all as specified and as directed by Engr- in- Charge.
201Material and labour for taking out of unservicable self starter 12 volt and connected unserviceable portion of electric wiring and carring out repairs and overhauling of the self starter for 30 KVADG set and replacement of armature, carbon brush, bearing, bendix penion,solenoid switch, bearing, tapping of field coil refixing of all component and fixed in existing postion including testing complete all as directed.
202Supply and fixing in repair lead acid battery 12 Volts 90AH, PULSE Sealed maintenance free battery with three year warranty complete all as specified and as directed. Make :Exide/SF Sonic/Amron.
203M & L forbattery connecting wire made of copper 35 sqmm ,1.5 mtr long including brass clips/ clmps heavy dutyin one side and copper lugs on other side ofsuitable sizes fixed, including dismantling of worn battery clamp and battery connecting wire, complete all as specified and as directed.
204M & L for Servicing the silancer assembly, remove the complete silencer assembly from DG set of capacity 30 KVAby removing nuts bolts complete, including opening the wall of bldg outlet remove the old asbetose rope, remove the blockage, reassemble the silencer with DG set with new gasket, nut, bolts & washers, gas welding on damaged portion of pipe, providing asbetose rope of size 15 mm dia insulation over silencer including one coat of plaster of paris over the asbetose rope from DG set mouth to exhuast pipe end upto inside wall of DG set room appx 03 Rm length complete all as specified and as directed by Engr- in- Charge.
205S&F MCCB three pole 25KA 63A, adjustable Thermal Magnetic release setting fixed to LT panel board with necessary arrangement for mounting if required , complete all as specified and directed.
206S&F changeover switch with SS encloser of 63 Amps, 4 pole including necessary parts , complete all as specified and directed.
207S&F of 25mmx4mm galvanised MS strip , complete all as specified and directed.
208Supply only rotary barrel hand driven pump set suitable for transfering oil, diesel & kerosene, dual directional operation, solid cast iron cosnstruction, steel tubing for inlet and outlet, o1 inch outlet including 5m durable flexible pipe , complete all as specified and directed.
209Servicing of Centrifugal Pump set of capacity 20HP installed at Turial, installation by Authorised Manufacturer Representative, complete all as specified and directed. Note:- (a) The cost ofspare parts will be measured and paid seperately. (b) The cost of transportation (To and fro) for all kind of necessary equipments/T&P shall be arranged/brought by contractor to complete job at site or at E/M yard and the cost shall bedeemed in quoted ratesand no extra cost is apllicable.
210Supply and fix , in replacement ofAir filter for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: BOSCH/LUCAS/PUROLATOR or equivalent.
211Supply and fix , in replacement of lubricating oil filter for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: BOSCH/LUCAS/PUROLATOR or equivalent.
212Supply and fix , in replacement of fuel oil filter for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: BOSCH/LUCAS/PUROLATOR or equivalent.
213Supply and fix , in replacement of fan belts 63, V-type suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: BOSCH/LUCAS/PUROLATOR or equivalent.
214Supply and fix , in replacement of fan belts 72, V-type suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: BOSCH/LUCAS/PUROLATOR or equivalent.
215Supply and fix , in replacement of battery terminals made of brass, suitable for battery of any type/make and capacity , complete all as specified and directed.Make: BOSCH/LUCAS/PUROLATOR or equivalent.
216Supply and fix , in replacement of piston suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
217Supply and fix , in replacement of piston ring suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
218Supply and fix , in replacement of connecting bearing suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
219Supply and fix , in replacement of crank bush brass suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
220Supply and fix , in replacement of fan belts 72, V-type suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.
221Supply and fix , in replacement of main bearing suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
222Supply and fix , in replacement of center bearingsuitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
223Supply and fix , in replacement of nozzle suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
224Supply and fix , in replacement of planjar spring suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
225Supply and fix , in replacement of head gasket suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
226Supply and fix , in replacement of oil seal complete suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
227Supply and fix , in replacement of gasket unit complete suitable for pump set of any type/make and capacity of 14.7 KW ( 20HP), complete all as specified and directed.Make: Kirloskar/Champion/Ghelani
228M & L for taking out of unserviceable Dynamo Assy complete set from 14.7 KW, 20HP pump setincluding Supply & fixing new Dynamo Assy complete set including all accessories such as nuts bolts and washer etc to its original position complete all as specified and as directed by Engr- in- Charge.
229Supply and fix , in replacement of radiator hose flexible, with and including taking out old hose and making all connection, testing for smooth operation, complete all as specified and directed.Make: Kirloskar/Cummins
230Supply and fix , in replacement of coupling suitable for Centrifugal pump of Diesel Enginecapacity 14.7 KW 20 HP, complete all as specified and directed.
231Supply and fix , in replacement of battery 12 V suitable for DG set, complete all as specified and directed.
232Supply and fix , in replacement of leather gasket ISI marked, complete all as specified and directed.
233Supply and fix , in replacement of gland gasket of different sizes, complete all as specified and directed.
234Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 16 Sqmm, 4 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
235Taking out old unserviceable street/ security/ flood/ garden lights from site of work all as directed.
236Taking out old unserviceable UG cables of any site of work all as directed.
237Supplying, laying, jointing, testing and commissioning 1100 volts grade, XLPE insulated, screened, PVC sheathed, galvanised steel pipe or wire armoured, heavy duty electric cables with aluminium conductor, cross sectional area of size 06 sq mm 02 core and laid in trenches/ducts /floor passing through pipe etc complete all as specified.
238Material & labour GI tube light grade 25 mm bore with all fitting laid to wall and ceilings, complete all as specified anddirected.
239Material and labour for steel tubular swaged pole 09m complete with cast iron base plate,finial taper plug, bolts, nuts and screws as specified type 410 SP- 31 (9m long)confirming to IS-2713 (Part I & II) including painting of pole with two coats of aluminium paint over a coat ofred oxide zink chrome primer from top of the pole to 1.5m above the bottom of the pole and painting with two coats of black bituminous paint over a coat of red oxide zink chrome primer upto 1.5m from bottom of the pole including numbering ofpoles complete all as specified and directed. Note : Excavation and earth work and PCC shall be measured and paid separately under respective items.
240Material and labour for PCC 1:2:4, type B1 using 20 mm graded crushed stoneaggregate as in coping of poles/stay poles including necessary form work, weathering, slightly rounded or chamfered angles and throating complete all as specified.
241Material and labour for PCC 1:2:4, type B2 using 40 mm graded crushed stoneaggregate as in foundations filling and mass concrete etc, for pole concreting all as specified.
242Material and labour for PCC 1:3:6, type C2 using 40 mm graded crushed stoneaggregate as in foundations filling and mass concrete etc, for pole concreting all as specified.
243Supply and fix PVC junction box with hinged door and locking arrangements, weather proof with IP 65 protection and facilited for cable entry in and out of size 150mm x 100mm to be fixed on circular steel pole including fixing arrangements with 4 mm MS clamps and nut bolt of suitable size and comprising of PVC connector and MCB SP 10 KA, 6 Amps including taking down old one all as specified.
244Supply and fix street light fitting LED of 60 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection, complete all as specified and directed.
245Supply and fix street light fitting LED of 45 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection, complete all as specified and directed.
246Supply and fix bldg security light fitting 20-25watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection, complete all as specified and directed.
247Supply and fix flood light fitting 50watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection, complete all as specified and directed.
248Supply and fix LED Solar street light fitting 35-40 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed. Make: Axxon/TATA Solcar/Bajaj/Havells/Crompton or equivalent.
249M&L for fabrication of GI pipe bracket suitable for mounting street light on pole or on wall including bracket mounting clamp, nuts and bolts, painitng with synthetic enamel paint, complete all as specified and directed.
250S & F Crown shape post top lantern in soothing opal finish made up of polycarbonate material suitable upto 15-20 watt LED lamp with robust design and efficient light distribution, complete all as specified and directed.
251S&F post top lantern/gate light LED type 25 watt 230 V AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp , complete all as specified and directed. Make:-Cat No. CORALPT25WLED757PSYMTOPC of Havells or equivalent to Bajaj/Philips/ Wipro/ Syska LED/ M/SSurya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
252S&F for steel work in tubular trusses including special shape washer etc. For globe/gate light fittings heavy grade of size 60 mm dia duly painted with black/white colour synthetic enamel paint over a coat of red oxide primer and cut into pieces of required length, including taking down old one and fixing, complete all as specified and directed.
253S&F PVC sheathed, insulated, copper conductor cable of size 1.5sqmm 3 core for electric connection to street light, flood light, globe light, gate lightetc., complete all as specified and directed.