| 1 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supplying & laying factory made unreinforced Precasted cable cover LV type 1 Size 250x150x40mm size complete all as specified and directed by Engineer-in-Charge. |
| 4 | Returning filling in including ,spreading,levelling,watering and well ramming in layers not exc 25cm thick each complete all as specified and directed by Engineer-in-Charge. |
| 5 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 6 | M&L for painting of sign board (size 1x1mtr to 1.5x1.5 mtr)at sub stations by cleaning of surface by emery paper, applying single coat of redoxide as primer and double coat of synthetic enamel paint and marking of nomeclature of the installation with suitable size letter writting in capital letters.Note:- Size of letter, colour of paint will be complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L painting of Rolling Shutter, Iron Gates, LT Panels and AFPC Panels etc. by prepareing & cleaning of surface by removing girth, applying single coat of redoxide as primer and double coat of paint by spay painting complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for Numbering of Poles (Steel & RCC poles) by painting of surface in circular Shape in Yellow Colour and numbering in black colour complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L Painting of LT Poles by cleaning of surface by emery paper, applying single coat of redoxide as primer and double coat of paint complete all as specified and directed by Engineer-in-Charge. |
| 10 | Dismantling of old unsv LT Pole any type from root incl PCC & masonary completely from ground complete all as specified and directed by Engineer-in-Charge. |
| 11 | Dismantling of Cross arms, bracing, supports, clamps and back plates etc from LT poles complete all as specified and directed by Engineer-in-Charge. |
| 12 | S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge. |
| 13 | S&F in replacement of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (9 metres long) incl marking with yellow & black paint of 1 feet width alternate around the pole, complete all as specified and directed by Engineer-in-Charge. |
| 14 | S&F Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 incl erection of LT OH ACSR conductor and marking with yellow & black paint of 1 feet width alternately around the pole, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Dismantling of insulators any type, any size from LT Pole complete all as specified and directed by Engineer-in-Charge. |
| 16 | S&F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers andone galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L for Dismantling stay assembly complete incl demolition of concrete, etc. and excavation.S&F Stay assembly complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps incl cost of excavation and concrete cement & masonary work complete all as specified and directed by Engineer-in-Charge. |
| 18 | S&F in replacement of PVC insulated jumpers suitable for LT OH Conductor line 1100 volts of suitable size & length complete all as specified and directed by Engineer-in-Charge. |
| 19 | S&F in replacement of Anti-climbing device; spikes type made of mild steel iron duly painted in silver colour suitable for LT Poles incl fixing arrangement by nuts, bolts, washers and welding to suit the cross section of the pole complete all as specified and directed by Engineer-in-Charge. |
| 20 | S&F in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelledwhite, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engineer-in-Charge. |
| 21 | S&F No Admission Board notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures in signal red colour and fixed with M.S. clamps, bolts and nuts of suitable size of 30x20 cm size complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&F in replacement of Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia to safeguard from OH LT lines 1100 volt grade complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&F in replacement of Shackle Type, Porcelain, vitreous, Brown insulator of 1100 volts garde, height 100 mm and dia 115 mm including galvanised mild steel straps, washers, insulator bolts, washers and nuts complete all as specified and directed by Engineer-in-Charge. |
| 24 | S&F in replacement of \"D\" clamps made of Ms iron suitable for erection of OH ACSR lines 1100 volts grade duly painted in silver colour complete all as specified and directed by Engineer-in-Charge. |
| 25 | M&L for Servicing and Calibration of LT ACB circuit breaker installed in LT panel 440 volts of rating 630/800 Amp grade by cleaning of Panel & ACB by air blower, cleaning of deposited carbon and applying petrolium jelly, setting of tripping time and short circuit relay, earth fault fault relay etc by engaging of experienced technician complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth wire 4 sqmmby means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC/CI cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-Charge. |
| 28 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 25X4 mm thickby means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate complete all as specified and directed by Engineer-in-Charge and shown in EP-3 of SSR Part-I |
| 29 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32x6 mm thickby means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate complete all as apecified and directed by Engineer-in-Charge. and shown in EP-3 of SSR Part-I |
| 30 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm size GI Strip complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F in replacement of Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F in replacement of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F in replacement of LT lightning arresters for outdoor use, non-liner resistor type, horn gap and choking coil, maximum working pressure 1100 volts complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply, laying, Jointing connecting LTUG cable XLPEinsulated,PVC bedded galvanised steel strip or wirearmoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 240 sqmm 3.5 core laid in trenches/on poles/walls/in ducts/passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge. |
| 36 | All as per serial item No. 35 above but for 185 Sqmm 3.5 Core. |
| 37 | All as per serial item No. 35 above but for 150 Sqmm 3.5 Core. |
| 38 | All as per serial item No. 35 above but for 120 Sqmm 3.5 Core. |
| 39 | All as per serial item No. 35 above but for 95 Sqmm 3.5 Core. |
| 40 | All as per serial item No.35 above but for 70 Sqmm 3.5 Core. |
| 41 | All as per serial item No. 35 above but for 50 Sqmm 3.5 Core. |
| 42 | All as per serial item No. 35 above but for 35 Sqmm 3.5 Core. |
| 43 | All as per serial item No. 35 above but for 25 Sqmm 3.5 Core. |
| 44 | All as per serial item No. 35 above but for 16 Sqmm 2 Core. |
| 45 | All as per serial item No. 35 above but for 10 Sqmm 2 Core. |
| 46 | S&F in replacement of Aluminum thimbles suitable for 240 Sqmm 3.5 Core LT Cable by dismantling of LT cable from transformer/MCCB/Bus bar etc and cutting cable core ends and making fresh for fixing of new thimbles by using crimping tool, applying LT insulation tap, ixing & testing complete all as specified and directed by Engineer-in-Charge. |
| 47 | All as per serial item No. 46 above but for 185 Sqmm 3.5 Core LT Cable. |
| 48 | All as per serial item No. 46 above but for 150 Sqmm 3.5 Core LT Cable. |
| 49 | All as per serial item No. 46 above but for 120 Sqmm 3.5 Core LT Cable. |
| 50 | All as per serial item No. 46 above but for 95 Sqmm 3.5 Core LT Cable. |
| 51 | All as per serial item No. 46 above but for 70 Sqmm 3.5 Core LT Cable. |
| 52 | All as per serial item No. 46 above but for 50 Sqmm 3.5 Core LT Cable. |
| 53 | All as per serial item No. 46 above but for 35 Sqmm 3.5 Core LT Cable. |
| 54 | All as per serial item No. 46 above but for 25 Sqmm 3.5 Core LT Cable. |
| 55 | S&F Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor/indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured /PVC aluminium conductor cable of size 35 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 56 | All as per serial item No. 55 above but for cable of size 50- Sqmm to 95 Sqmm,3.5 Core complete all as specified and directed by Engineer-in-Charge. |
| 57 | All as per serial item No. 55 above but for cable of size 120 Sqmm to 185 Sqmm ,3.5 Core complete all as specified and directed by Engineer-in-Charge. |
| 58 | All as per serial item No. 55 above but for cable of size 240 Sqmm to 300 Sqmm ,3.5 Core complete all as specified and directed by Engineer-in-Charge. |
| 59 | S&F Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured /PVC aluminium conductor cable of size 25 to 35 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 60 | All as per serial item No. 59 above but for cable of size 50 Sqmm, 3.5 Core complete all as specified and directed by Engineer-in-Charge. |
| 61 | All as per serial item No. 59 above but for cable of size 70 Sqmm, 3.5 Core complete all as specified and directed by Engineer-in-Charge. |
| 62 | All as per serial item No. 59 above but for cable of size 95 Sqmm, 3.5 Core complete all as specified and directed by Engineer-in-Charge. |
| 63 | All as per serial item No. 59 above but for cable of size 120 Sqmm, 3.5 Core complete all as specified and directed by Engineer-in-Charge. |
| 64 | All as per serial item No. 59 above but for cable of size 150 Sqmm, 3.5 Core complete all as specified and directed by Engineer-in-Charge. |
| 65 | All as per serial item No. 59 above but for cable of size 185 Sqmm, 3.5 Core complete all as specified and directed by Engineer-in-Charge. |
| 66 | S&F in replacement of MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge. |
| 67 | SS&F in replacement of MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge. |
| 68 | S&F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge. |
| 69 | S&F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge. |
| 70 | S&F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge. |
| 71 | S&F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 315/350 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge. |
| 72 | S&F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge. |
| 73 | Dismantling of Capacitors of various capacity in the APFC Panel of any kVAr, testing of banks, MCCB/MCBs, internal wiring of panel, RYB indicators, RYB selector switches, Start/Stop push button, Ameter, Voltmeter & Multifunctional meter for its serviceability and cleaning of Panel from inside incl replacement of unsv parts complete all as specified and directed by Engineer-in-Charge. Note :- Parts will be measured and paid umder relavant item. |
| 74 | S&F in replacement of digital Ameter of span rating 600 Amps Suitable for LT Panel as per existing size complete all as specified and directed by Engineer-in-Charge. (Make :- Schnieder) |
| 75 | S&F in replacement of digital Voltmeter of span rating 500Volts Suitable for LT Panel as per existing size complete all as specified and directed by Engineer-in-Charge. (Make :- Schnieder) |
| 76 | S&F in replacement of Multifunctional meterSuitable for LT Panel 440 Volts as per existing size complete all as specified and directed by Engineer-in-Charge.(Make :- Schnieder) |
| 77 | S&F in replacement of RYB Indicator for LT Panel/APFC Panel complete all as specified and directed by Engineer-in-Charge. |
| 78 | S&F in replacement of RYB selector switch for LT Panel/APFC Panel complete all as specified and directed by Engineer-in-Charge. |
| 79 | S&F in replacement of Supply and fixing 415V 10KA \"C\" Curve MCB TP 25 to 63 Amps rating, 10 KA in the DB/LT Panel/APFC Panel complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 80 | S&F in replacement of Start Push Button (Green Colour) and Stop Button (Red Colour) in RYB selector switch for APFC LT Panel complete all as specified and directed by Engineer-in-Charge. |
| 81 | S&F in replacement of Power Capacitor 7.5kVAr rating suitable for 433 volt grade complete all as specified and directed by Engineer-in-Charge. (Make :- Schnieder) |
| 82 | S&F in replacement of Power Capacitor 10kVAr rating suitable for 433 volt grade complete all as specified and directed by Engineer-in-Charge. (Make :- Schnieder) |
| 83 | S&F in replacement of Power Capacitor 12.5kVAr rating suitable for 433 volt grade complete all as specified and directed by Engineer-in-Charge. (Make :- Schnieder) |
| 84 | S&F in replacement of Power Capacitor 15kVAr rating suitable for 433 volt grade complete all as specified and directed by Engineer-in-Charge. (Make :- Schnieder) |
| 85 | S&F in replacement of Power Capacitor 25kVAr rating suitable for 433 volt grade complete all as specified and directed by Engineer-in-Charge. (Make :- Schnieder) |
| 86 | M&L for treaming of tree/ tree branches spreaded over/touching the LT OH ACSR conductors/LT Poles/ LT Panels etc by taking proper shut down from MES complete all as specified and directed by Engineer-in-Charge. Note:- Contractor will provide all tools, ladder and safety equipments required for treaming of tree /tree branches. |
| 87 | S&F in replacement of Ameter of span rating 300 Amps Suitable for APFC Panel as per existing size complete all as specified and directed by Engineer-in-Charge. |
| 88 | S&F in replacement of Voltmeter of span rating 500Volts Suitable for APFC Panel as per existing size complete all as specified and directed by Engineer-in-Charge. |
| 89 | Dismantling of OH ACSR conductor from LT Poles and jointing/tightening of the broken/loose conductors and refixing the same on the LT Poles as in position as existing incl cost of jointing material, cleaning of pin insulators complete all as specified and directed by Engineer-in-Charge. |
| 90 | M&L for Dismantling of ACSR conductors, S&F Auminium conductor steel reinforced as per IS-398 (Part-2) of of 1996 suitable for 1100 volts OH line complete all as specified and directed by Engineer-in-Charge. |
| 91 | S&F in replacement of CT Coil ratio of rating 200/5, 50 Hz, Line voltage 440V, as per ISS-2705-1992 suitable for Existing LT Panel incl taking out unsv CT any type complete all as specified and directed by Engineer-in-Charge. (Make : Alliance Engineering Co. (India)) |
| 92 | S&F in replacement of CT Coil ratio of rating 400/5, 50 Hz, Line voltage 660V, as per ISS-2705-1992 suitable for Existing LT Panel incl taking out unsv CT any type complete all as specified and directed by Engineer-in-Charge. (Make : Alliance Engineering Co. (India)) |
| 93 | S&FPVC spacer suitable for LT OH conductor 1100 Volts grade complete all as specified and directed by Engineer-in-Charge. |
| 94 | M&L for of LT cable rout indicatorreading \"MES LT U/G 1100 V Cable\" and route of cable with arrow, made out of CI in square shape of size 200mm x 200mm x 10mm with 150mm leg, fixed in PCC pre-cast block of 250mm x 250mm x 1000mm complete all as specified and directed by Engineer-in-Charge. |
| 95 | Taking out worn out rusted nut bolts, S&F Nut bolts of various sizes as per site reuirement incl washers complete all as specified and directed by Engineer-in-Charge. |
| 96 | Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including PCC/masonary work to fix lanterns on post top complete all as specified and directed by Engineer-in-Charge. |
| 97 | Supply and fixing LED flood light 70 watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-Charge. |
| 98 | Supply and fixing LED Solar street light fitting 12 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete incl excavation & earth work for fixing of Pole & connected items etc to be installed at 11 KV MRs and Sub Stnations complete all as specified and directed by Engineer-in-Charge. |
| 99 | Supplying and laying synthetic Rubber insulated mats 16 mm thick for voltage upto 1.1 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engineer-in-Charge. |