Public Administrative Department Local Bodies Closing in 0 days TDR #30091888

Electrification And Water Supply To Existing Cafeteria At Nathatop And Electrification Works For Double Deck Bathroom And Street Lights At Nathatop

Issued by Local Bodies · KUD, Jammu And Kashmir
Tender Value
9.97 Lakhs
Estimated cost
Bid Submission
10 Dec 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
KUD → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Electrification And Water Supply To Existing Cafeteria At Nathatop And Electrification Works For Double Deck Bathroom And Street Lights At Nathatop

BOQ

Name of Work:-Electrification and water supply to existing Cafeteria at Nathatop and electrification works for double deck, bathroom and street lights at Nathatop
Sl. No. Item Description
1Wiring for light point/Fan point/Exhaust fan point/call bell point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cables in surface/recessedPVC conduit withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FRLSPVC insulated copper conductor single core cables etc as required (ISI make).
2Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. (`ISI make) complete job.
32X2.5 Sq.mm cu + 1X2.5 Sq.mm earth wire.
42X4 Sq.mm cu + 1X4 Sq.mm earth wire.
5Supplying and fixing following modular switch/socket on existing modular plate and switch box including connections but excluding plate etc as required.
6a) 5/6 amp switch.
7b) 3 pin 5/6 amp socket.
8c)15/16 amp switch.
9d)15/16amp socket.
10Supplying and fixing followingsize/ modules, GI box along with modular base and cover plate for modularswitch in recess etc as required.
11a) 6 Module(200mmX75mm).
12b) 3 Module(100mmX75mm).
13c) 12 Module(125mmX75mm)
14Supplying of shutter type exhaust fan 300mm of Crompton greaves/bajaj/havels make.
15Installation of exhaust fan in the existing opening including making goods the damage, connection, commissioning etc as required upto 450mm sweep.
16Supplying, installation testing and commissioning of 15 watt concealed lights complete job. (Panasonic,Crompton, havels, bajaj,ISImake)
17Supplying, installation testing and commissioning of decorative mirror light including accessories suitable upto 18 watt complete job. (Panasonic,Crompton, havels, bajaj, ISI make)
18Supplying, installation testing and commissioning of decorative hanging ceiling pendent light upto 60 watt for dining hall/restaurant complete job. (Panasonic,Crompton, havels, bajaj, ISI make)
19Supplying, installation testing and commissioning of63A SPN MCB. (Schneider,Legrand,anchor havels, ISI make)
20Supplying , laying, testingand commissioning of 10sqmm2 core 1.1KV ratingPVC insulatedPVC sheathedarmouredaluminium cablerecessed/surface complete job(havels, polycab,KEI make)
21Supplying, installation testing and commissioning of decorative Tube light including accessories suitable upto 18 watt complete job. (Panasonic,Crompton, havels, bajaj, ISI make)
22Supply , Installation, Testing and commissioning of all in one integrated LED solar light lighting luminaries (with suitable GIpipe with mounting acessories including concreting complete job) with almunium housing/die cast,Uv stabilized polycarbonate cover, havinh minium system lumen output of 3000 and system wattage not exceeding 18 watt, 12V DC with system sfficancy not less than175lm/W.Lumaniries has integrated MPPT charger with driver with charger Efficiency >90% and should be available in CCT of 5700k.Luminaries should have highly safe and advanced long life maintenance free lithium iron phosphate (liFepO4) battery -256 used for hassle free operations alongb with inbuilt PIR sensor with dimming profile.Lifetime should be at least 50000 burning hours at L70 at 25 degree centigrade . Manufacturer shall have inhouse lab approved by NABLor ministry of science of Govt of india. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters (make-Bajaj.wipro,Phillips,Crompton)
23Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings,lights complete job(25no)
24a)Electrician
25b) Khallasi
26Supply, installation, testing and commissioning of connector FP 63 amp.
27Supplyingand fixing 5 amp to 32 amp rating 240/415 volts 10 KA, “ C” curve, miniature circuit breaker suitable for inductive load of following pole in existing MCBDB complete with connection, testing and commissioning etc as required.(Make: Havels/ABB/Schneider/Siemens)
28a) Single pole.
29b)Single pole and neutral
30Supplying and fixing following way, single pole and neutral ,sheet,MCBdistribution board, 240 volt on surface/recess, complete with tinned copper busbar copperbusbar, neutral busbar,earth bar,din bar detachable gland plate ,interconnections phosphatised and powder painted including earthing etc as required (but without MCB/RCCB/isolator)
31a) 8 way double door.
32a) 6 way double door.
33Supply and fixingof following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
3432 mm
35Providing installation, testing and commissioning of outdoor type, cubical feeder panel with 1.6 mm thick sheet MS/CRS sheet painted from inside and outside to provide complete protection from water moisture, dust and vermin proof, duly wired up with the following accessories/equipment.a)MCCB FP 100 amp 1 nos (Make-L&T/ABB/Siemens ISI)b)Contactor 50 amp 1 nos(Make L&T/ABB/Siemens ISI)c)Digital Timer 1 nos.(Reputed make)d)Voltmeter 1nos.e) Selector switch 1nos.f)Indicators R,Y,B.g)Busbar and fittings.
36Providing of Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. With charcoal/ cokeand salt as required.
37Providing and laying earth connection from earth electrode with 6 SWG dia G.I Wire in 15 mm dia G.I pipe from earth electrode including connection with G.I thimble excavation and re-filling as required.
38Supplying and fixing of 50 mm dia X 2.00 meters long G.I pipe (medium class) bracket for mounting of fluorescent /HPMV /LED street light fitting on pole including bending the pipe to the required shape, 2 Nos 40 mm X3 mm iron clamps with nuts, bolts and washer, paintingthe iron clampswith primer and finish paints etc. As required.
39SITC of high quality integrated LED street light with a minimum system lumen of 9900 Lm and system wattage 90W with a nominal efficiency 110 lumen/watt. CCT of 5700k with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high pressure die-cast aluminium with heat resistant toughened clear glass to with stand extreme environments with PF >0.95. Lifetime of 50k hours @L70. The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have SKV internal 10kv external surge protection in the Luminaire. Manufacturer shall have in house lab approved by NABL or ministry of science of govt. of India. LM 79 and Lm 80 report need to be submitted from a NABL/UL accredited lab to verify above parameters.MakeCrompton, Philips/Bajaj/Wipro.
40Supply, installation testing and compressing of aluminium lugs/aluminium thimble complete job.
41Supply, laying, testing and commissioning of 10 sqmm 2 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei)
42Supply, laying (75 Cm below ground level including excavation and refilling the trench), testing and commissioning of 10 sqmm 4 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei)
43Supply, laying (75 Cm below ground level including excavation and refilling the trench), testing and commissioning of 25 sqmm 4 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei)
44Supply, laying, testing and commissioning of 2.5 sqmm cu wire.(Make-polycab, anchor, havels).
45Supplying and drawing following sizes of FRSL PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required (ISI make) a) 1x1.5 sqmm
46Supply and fixing of PVC batton complete job.
47Painting of Streets lights pole to coats of green paints (make Narolac/Assian Paint)

AI Tender Summary

OUR REF NO 30091888
AUTHORITY Local Bodies
TENDER VALUE 9.97 Lakhs
LAST DATE 10-12-2021
Authority
Authority Name Patnitop Development Authortiy Limited
Work Description Electrification And Water Supply To Existing Cafeteria At Nathatop And Electrification Works For Double Deck Bathroom And Street Lights At Nathatop
Basic Detail
Tender No 33 OF 2021 - 22
Bidding Type Tender
Location
City KUD
State Jammu And Kashmir
Key Dates
Publish Date 30 Nov 2021
Submission Date 10 Dec 2021
Open Date 11 Dec 2021
Finance
Tender Value 9.97 Lakhs
Tender Fee 500
EMD Ref. Documents
Exemption Not Available
Document List
8689cb7a-5680-4b5b-9103-33c9d31f541f.html
BOQ_330451.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 30, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 10, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 11, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

8689cb7a-5680-4b5b-9103-33c9d31f541f.html

xls

BOQ_330451.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders