| 1 | Taking down copper /aluminium point wiring (light, fan, bell, socketor power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc.Removing m,aterials to store for keeping in safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces ofwalls, floors etc. |
| 2 | Taking down the ceiling fan in situ and refixing after servicing, repairing and painting to ceiling fan/Exhaust fanincluding exhust fan louvers , scratching old paint and preparation of surface for painting with one coat of white/grey enameled paint all as specified and directed. |
| 3 | S&F in repair Sub Main Wiring with two single core PVC insulated cable of size 6.0 Sqmm multistranded copper conductor drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and One core of 4.0 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :-Two Nos of 6.0 Sqmm Wire and one No of 4.0 Sqmm Earth wire in One RM length Measured as one unit length. |
| 4 | M&L for point wiring with 1.5 Sq mmsingle corePVC insulated unsheathedcopper FRLSH multi stranded conductor cable in andincludingConcealed PVC conduitof size 20/25mm ISImarked inclusive oftees ,bend ,elbows etc upto and including sunk in Anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick sheet cover ISI marked of suitable size complete including PVC insulated multi strandedcopper conductor 1.5Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalinclcutting, chasses and makinggooddisturbed surface to match with existing finish with plaster forcomplete all as specified and directed by Engr-in-charge |
| 5 | (a) One light/fan point controlled by one, one way switch 5 Amps |
| 6 | (b)One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 7 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 8 | Ditto all as per above itemsbut with 1100 volts grade copper standard conductor cable of size 2.5Sqmm with 1.5Sqmm solid copper conductor PVCfor 3 pin switch socket outlet15 Amp independent board complete all as specified and directed by Engineer in charge . |
| 9 | Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn into the existing conduits including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahssrs and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge. |
| 10 | (a) One light/fan point controlled by one switch. |
| 11 | (b) One socket point 5 Amp controlled by one switch on same board. |
| 12 | (c) One socket point 5 Amp controlled by one switch on Independent board. |
| 13 | Ditto all as above items but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 1.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge. |
| 14 | S & FSwitch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site. |
| 15 | S & F socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site. |
| 16 | S&F switch socket combination multipin5 and 16 Amps AC 230 volts flush type complete all as specified and directed by Engineer in charge |
| 17 | S & FCeiling rose, surface Bakelite with 3 terminals, ISImarked for batten fitting complete all as specified. |
| 18 | Supply and fixingfan regulator socket type step capacity of polycarbonite complete all as specified and directed by Engineer in charge. |
| 19 | Supply and fixing in replacement lamp holder PVC Polycarbonate type body, with back platefor batten fitting icluding 9 watt LEDlampcomplete all as specified and as directed by Engineer in charge. |
| 20 | S & F in repairsLED sky glow downlighter 10/12 Watt complete with all acessories etc all complete Make: Havells enduraneohessurfacedls15wled840s or equ in philips, surya |
| 21 | Supply & Fixingin repairs Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification Make : Philips Cat part BN 021 LED 22S 6500/4000 PSU GR SI or eqv in bajaj ,surya |
| 22 | S&F LED in repairs light fitting square 57x57 CMNot less than 40 wattalong with fixtureSurface / Recessed /Pendent mounting LED luminaries with diffuserchannel Luminaires ers, connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three coreflexibleflexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge. Make: Philips cat part no: RC375B LED 36S/840 PSU W60 L660 S2 WH or equiv in bajaj/havells. |
| 23 | Supply & fix in replacement ofLED Security Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos ofpole fitting clamps made out of MS flat , nutsand boltsand painting with aluminium paint. complete all as specified and as directed.Make: HAVELLS Cat part no LHDAUU7PA7J025 VLUMINA or Equ in philips,luker. |
| 24 | Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make : Legrand CAT NO 507611/ SIEMENSCAT NO 8 GB 32102RC8/GE |
| 25 | S & F in repairSheet metal enclosure DBsTripplePole and Neutral 4- way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge.Make:Legrand cat part 5077 80 /Siemens/GE |
| 26 | S & F in repairs MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed.Make : Legrand DX3 DP CAT No 408637/ Siemens cat no- 5SL 42327RC / GE |
| 27 | S & F in repairs MCB TPN 415 volts 63 Amps, 10 KA breaking capacity 4 pole complete all as specified and directed by Engineer in charge Make: Legrand DX3 TPN C 63A AC 408683 / Siemens cat no- 5SL44637 RC / GE |
| 28 | S & Fin repairMCB Single pole rated capacity 5 to 40 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed.Make:Legrand cat no DX3 SP4085 87,408590,408592,408593,408594,408595/ Siemens cat no- 5SL41067RC, 5SL41107RC, 5SL41167RC, 5SL41207RC, 5SL41257RC, 5SL41327RC / GE |
| 29 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means ofnut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 30 | Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.Make: Legrand cat part noEkinox metra plug 5078 11 |
| 31 | S&F in repairsSub Main Wiring with two single core PVC insulated cable of size 4.0 Sqmm multistranded copper conductor drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and One core of 2.5 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :-Two Nos of 4.0 Sqmm Wire and one No of 2.5 Sqmm Earth wire in One RM length Measured as one unit length. |
| 32 | S&F in repairsSub Main Wiring in replacementoftwo single core PVC insulated cable of size 1.5 Sqmm multistranded copper conductor drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 20mm dia with all conduit fitting,fixing accessories and One core of 1.5 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :-Two Nos of 1.5 Sqmm Wire and one No of 1.5 Sqmm Earth wire in One RM length Measured as one unit length. |
| 33 | S & FSwitch Piano type bell pushsingle pole 5 amp, 230 Volts complete all as specified and directed at site. Make : Anchor or equivalent Make:anchor,plaza,leader |
| 34 | Supply and fixing calling bellsytem with indicator of 14 way high glow digital numerical display and inbuilt bell for14 Users complete with fixing and enclosure complete with call bell as requiredall asspecified andas directed Make ;- Supremewired call bellor equivalentas approved by GE |
| 35 | Supply and Install of Chemical Dosing suitable to inject solution upto 25 LPH comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM, assembly with agitator, dosing and agitator in single motor, agitator with SS sweep blade duly FRP coated, FRP tank 100 Ltrs capacity complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint withchemical grade PVC NRV with all accessories complete all as specified and directed by Engr-In-Charge. Make- :- Sathya Sai Aqua Pura Services , Sombansl Enviro Engg Pvt Ltd (SEEPL) ,and Declibac TechnologiesNote :-(i) Rate quoted by contractor deems to be included for electrial connection from existing pannel to MCB and MCB to dosing system using suitable size of wire as recommended by manufacturer(ii)Rate quoted by contactor also deems to be included for 2 yearreplacement warranty after completion work . (iii) Rate quoted by contractor also included for suitable size of triple for MCB and MCB DB . |
| 36 | M&L for 100 mm thick cement concrete (1:2:4), type B-2 (using 40mm graded stone aggregate) as in hard standing/platform, laid in alternate bays andfinished surfaces even and fair complete all as specified and directed . |