Repair / Replacement / Maintenance / Servicing Of Security / Perimeter / Street Lights Summer Appliances And Other Allied Work At Mil Stn Beas And Jandiala Guru Under Ge Kapurthala Repair / Replacement / Maintenance / Servicing Of Security / Peri, Kapurthala-Punjab

Military Engineer Services-MES has published Repair / Replacement / Maintenance / Servicing Of Security / Perimeter / Street Lights Summer Appliances And Other Allied Work At Mil Stn Beas And Jandiala Guru Under Ge Kapurthala Repair / Replacement / Maintenance / Servicing Of Security / Peri. Submission Date for this Tender is 23-12-2021. Street Lighting Tenders in Kapurthala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

30079028
Corrigendum : Repair / Replacement / Maintenance / Servicing Of Security / Perimeter / Street Lights Summer Appliances And Other Allied Work At Mil Stn Beas And Jandiala Guru Under Ge Kapurthala Repair / Replacement / Maintenance / Servicing Of Security / Peri
Open Tender
Indian
Punjab
Kapurthala
23-12-2021

Tender Details

Repair / Replacement / Maintenance / Servicing Of Security / Perimeter / Street Lights Summer Appliances And Other Allied Work At Mil Stn Beas And Jandiala Guru Under Ge Kapurthala Repair / Replacement / Maintenance / Servicing Of Security / Perimeter / Street Lights Summer Appliances And Other Allied Work At Mil Stn Beas And Jandiala Guru Under Ge Kapurthala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR/ REPLACEMENT/ MAINTENANCE/ SERVICING OF SECURITY/ PERIMETER/ STREET LIGHTS, SUMMER APPLIANCES AND OTHER ALLIED WORK AT MIL STN BEAS AND JANDIALA GURU UNDER GE KAPURTHALA
Sl. No. Item Description
1Attending of day to day street/security/Gate light/Post top lantern/High mast light fixed at up to 16 mtr height (HPSV,MH,Flourescent tube light, T-5, LED , Flood light fittings etc. of any make), street light panels, rectifying defects in cable, over head conductor/jumper etc and complaints received through telephone or in person and reactification of defects installed on street light poles 9/11 mtr long, building walls, roof by bringing down the fittings on ground or in position including inreplacement of lamp, ignitor, flexible wire, reflector etc including cleaning of glass/acrylic cover for clear reflection of light, inreplacement of old unserviceable street light fittings with new fittings etc as required to make the light fitting functional (Vehicle, ladder, tools and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. Note : (i) Light fitting, ballast, starter, ignitor, diffuser, cable, flexible wire and LED drive if required to be replaced in repair shall be measured and paid separetely under relevant item of this BOQ for supply and fixing inreplacement.All consumable materials such as tape, flexible wire, nuts, bolts, washer (if found missing), of clamp for bracket, ignitor holder/starter holder shall be deemed to be included in the quoted rate (ii) contractor will confirm availability of two electrician and two helper for attendingand reactifying the complaints at 2 ASD Depot Area and Bde HQ Area & 415 Engr Sqn Jandialawithin 8 hours on receipt of complaints. (iii) contractor manpower should report at complaint cell Beas at 9.00 AM to JE E/M and take complaints and execute it within 08 Hrs. A register will be maintained for recording each complaints date wise for the period of contract and submit a certificate to the Engr in Charge that following Nos of complaints has been attended and rectfied during the period duringhis RAR/FB duly signed by Contractor, JE E/M & Engr in Charge.
2All as per item No 01 but for gate light/Post top lantern .
3All as per item No 01 but for 16 mtr height high mast lights.
4Taking down old unserviceable any type S/Lightfitting and Supply and fixing LED street lightfitting 25 WattIP65 Powder coated pressure die cast aluminium SMD LED Street light with heat resistant toughened glass of Make- Crompton Cat No LSTS-25-CDL orequivalent in Bajaj/Havells/C&S / Philips.
5Taking down old unserviceable any type fitting and Supply and fixing LED street lightfitting 35 WattIP65 Powder coated pressure die cast aluminium SMD LED Street light with heat resistant toughened glass of Make- Crompton Cat No LSTS-30-CDL Freedom +or equivalent in Bajaj/Havells/C&S/ Philips.
6Taking down old unserviceable any type S/Lightfitting and Supply and fixing LED street lightfitting 45 WattIP65 Powder coated pressure die cast aluminium SMD LED Street light with heat resistant toughened glass of Make- Crompton Cat No LSTS-25-CDL orequivalent in Bajaj/Havells/C&S / Philips.
7Taking down old unserviceable any type fitting and Supply and fixing LED street lightfitting 60 WattIP66 Powder coated pressure die cast aluminium SMD LED Street light with heat resistant toughened glass of Make- Crompton / Bajaj/Havells/C&S/ Philips.
8Taking down old unserviceable any type of MH/HPSV flood light fitting and supply and fixing LED flood light 120 Watt, IP66 LED floodlight with pressure die-cast aluminium housing, complete with all accessories with nuts bolts, clamps etc Make-Crompton / Bajaj/Havells/C&S/ Philips.
9Taking down old unsv Bulk head light/ Bldg security light and Supply and fixing LED bldg security light fitting 20 watt Powder coated pressure die cast aluminium compact LED security light including1.5 mtr long 40 mm bore GI pipe mounting bracket made to shape for fixing on wall with 40 mm x 6 mm flat iron clamp 02 numbers with 16 mm dia bolts, nuts and washersand including point wiring with switch control all as specified and directed by Engineer-in-Charge.Make- Crompton / Bajaj/Havells/C&S/ Philips
10Supply only in replacement against Item No.01 above, open construction ballast suitable for 240 volts 50 Hz 1 x 70 watt SON/MH Lamp. Make : Crompton / Bajaj/Havells/C&S/ Philips.
11Supply only in replacement against Item No.01 above, open construction ballast suitable for 240 volts 50 Hz 1 x 150 watt SON/MH Lamp. Make : Crompton / Bajaj/Havells/C&S/ Philips.
12Supply only in replacement against Item No.01 above, open construction ballast suitable for 240 volts 50 Hz 1 x 250 watt SON/MH Lamp. Make : Crompton / Bajaj/Havells/C&S/ Philips.
13Supply only in replacement against Item No.01 above, open construction ballast suitable for 240 volts 50 Hz 1 x 250 watt HPMV Lamp. Make : Crompton / Bajaj/Havells/C&S/ Philips
14Supply only in replacement against Item No.01 above,open construction ballast125watt with wire suitable for125 Watt HPMVMake : Crompton / Bajaj/Havells/C&S/ Philips.
15Supply only in replacement against Item No.01 above, electronic ballast 2 x 14 watt with wire suitable for 2 x 14 watt T5 FTL. Make : Crompton / Bajaj/Havells/C&S/ Philips.
16Supply only in replacement against Item No.01 above, metal halide single/double ended clear tubular lamps (MH DE) suitable for 150 watt enclosed fixture. Make :Crompton / Bajaj/Havells/C&S/ Philips.
17Supply only in replacement against Item No.01 above, in replacement against Item No. 45 above, metal halide single/doubleended clear tubular lamps (MH DE) suitable for 250 watt enclosed fixture. Make : Crompton / Bajaj/Havells/C&S/ Philips.
18Supply only in replacement against Item No.01 above, metal halide single/double ended clear tubular lamps (MH DE) suitable for 400 watt enclosed fixture. Make : Crompton / Bajaj/Havells/C&S/ Philips.
19Supply only in replacement against Item No.01 above, high pressure sodium vapour tubular clear lamp (SON-T) suiable for 70 watt Make : Crompton / Bajaj/Havells/C&S/ Philips.
20Supply only in replacement against Item No.01 above, high pressure sodium vapour tubular clear lamp (SON-T) suiable for 150 watt Make : Crompton / Bajaj/Havells/C&S/ Philips.
21Supply only in replacement against Item No.01 above, high pressure sodium vapour tubular clear lamp (SON-T) suiable for 250 wattMake : Crompton / Bajaj/Havells/C&S/ Philips
22Supply only in replacement against Item No.01 above, high pressure sodium vapour tubular clear lamp (SON-T) suiable for 400 wattMake : Crompton / Bajaj/Havells/C&S/ Philips
23Supply only in replacement against Item No.01 above, high pressure Mercury vapour lamp suiable for 400 wattMake :Crompton / Bajaj/Havells/C&S/ Philips.
24Supply only in replacement against Item No.01 above, high pressure Mercury vapour lamp suiable for 250 wattMake : Crompton / Bajaj/Havells/C&S/ Philips.
25Supply only in replacement against Item No.01 above, T-5 rod 14 watt 6500 K, suitable to operate on 240 volts.Make : Crompton / Bajaj/Havells/C&S/ Philips.
26Supply only in replacement against Item No.01 above, Ignitors suitable for 70 to 400 W SON & MH Lamps short distance type Make : Crompton / Bajaj/Havells/C&S/ Philips.
27Taking down old unserviceable MCB and S & FMCB SP, 10 to 32 Amp 240 Volt 20 KA, B-Series,in DB/Junction Box complete all as specified and directed.
28M&L in replacement ACSR conductor of any size including binding on existing LT poles or new poles with 2 mm dia aluminium binding wire complete including dismantling/taking down of old unsv ACSR conductor all as specified and directed. (Squirrel/Weasel type ACSR to be used)
29Supply and fixing in inreplacement, shackle type porcelain vitreous white, green or brown insulators for working pressure 1100 volts, 90 mm dia, 75 mm height including galvanised MS straps, washers, insulator bolts, washers & nuts compete all as specified and directed.
30S & F inreplacement pin type insulator porcelain white brown or green including one galvanized mild steel spindle two galvanised iron washer and one galvanised iron nuts 100 mm height 65 mm dia for 1100 volts grade.
31Supply, fabricate and fixing in inreplacement cross arms (anytype) supports, bracing, stiffeners, clamps etc fabricated from structural steel section including drilling of holes nuts, bolts, washers etc including painting with two coat of aluminium paint over a coat ofred oxide primer complete all as specified and directed.
32Supply, erecting in truely vertically position concrete pole 9 Mtr long of size 102 mm x 172 mm at top and 102mmx279 mm at bottom class 10 complete and re-fixing of overhead conductor on pole including painting of pole up to 1.5 Mtr high from PCC coping in black & white strip each of 30mm highwith two coats of synthetic enamel paint complete all as specified and directed (Excavation/ earthwork/PCC work shall be measured & paid separatelly) including taking out existing unserviceable pole & removing from site.
33Material and labour for PCC 1:4:8 type D2 (using 40 mm graded stone aggregates) as in foundation bed and around the pole as massconcrete including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed.
34All as per description of seiral item No 33 here-in-before but PCC (1:2:4) type B-1 using 20 mm graded stone aggregates as in coping of poles.
35Taking down ACSR conductor and insulators of any type on existing LT poles all as specified and directed
36Supplying, laying, jointing and testing under ground XLPE/PVC armoured heavy duty electric cable insulated and PVC sheathed LT with stranded aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 4 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed by Engr-in-Charge. Note : Excavation , earth work and GI pipeshall be measured and paid seperately. Make : KEI/CCI/Havells
37All as per item No 36 but cross sectional area 16Sqmm 4 core.
38All as per item No 36 but cross sectional area 25Sqmm 4 core.
39Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation of poles/ stays/ laying of cables etc and gettingout including trimming of sides of trenches complete all as specifiedand directed.
40Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed.
41Removing of surplus excavated soilto a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point completeall as specified and directed.
42Material and labour for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed.
43Material and labour for brick protection using old size sub class ‘B’bricks, laid flat, dry adjacent to each otherlaid length wiseperpendicular to theaxis of cable complete all as specified and directed.
44M&L for preparation of old painted surface of PCC LT poles and applying two coats of synthetic enamel paint in alteranate black and white strips of 30 cm each up to 1.5 mtr height from top of PCC coping and numbering of poles complete all as specified and directed.
45M&L for preparation of old painted steel pole of 9 m long and painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer from top of the pole to 1.5 m above the bottom of the pole and painting with two coats of black bituminous paint over a coat of red oxide zinc chrome primer upto 1.5m from bottom of the pole complete all as specifiedand directed
46Labour only for cutting/pruning of tree branches 1.5 mtr all around the LT overhead lines of span 30 mtr approx and to thethe entire satisfaction of Engineer-in-charge,
47Supply & fixing GI pipe light grade 40 mm bore for cable protection fixed to pole/along wall/floor/under road etc complete all as specified and directed. Note : Clamps nuts & bolts etc shall be measured and paid for separately under appropriate items of sch "A"
48M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
49M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized iron srtrip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
50S & F in inreplacement MCCB 160 Amp 04 pole 415 volt 50 HZ breaking capacity 36 KA with adjustable thermal release and adjustable magnetic setting complete as per existing make/model fixed on panel/pole/wall etc all as specified and directed. Make : Havells/C&S/L&T /Legrand
51S & F in replacment MCCB 200 Amp, 4 pole, 36 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete as per existing make/model fixed on panel/pole/wall etc all as specified and directed. Make : Havells/C&S/L&T /Legrand.
52S & F in replacment MCCB 250 Amp, 4 pole, 36 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete as per existing make/model fixed on panel/pole/wall etc all as specified and directed. Make : Havells/C&S/L&T /Legrand.
53S&F in replacement Battery 12 V, 180 AH dry type maintenance free for Security light DG stand by supply with connecting lead wires and terminal sets all as specified and directed by Engr in Charge
54Taking down old unserviceable GI bracket and supply and fixing GI bracket 20 mm bore 1.50 mtr length "L" shape suitable for fixing of street light fitting on pole complete with 2 Nos clamps, Nuts and bolts of suitable size all as directed by Engr in Charge.
55Supply and fixing for Circuit from MCB box to Streetlight withFR PVC insulated copper conductor single core cable with 2 x 1.5 sqmm + 1 x 1.5mm earth wire in surfaces/recessed/pole with suitable clamp as required in PVC conduit of size 20 mm dia
56S&F 1100 Volts grade heavy duty cable PVC insulated solidaluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or round of 10 sqmm cable.
57Supply and fixing in replacement 1100 volt grade heavy duty cable 3 core 2.50 Sqmm PVC insulated Aluminium stranded conductor passing through in 20 mm PVCpipe offor connection pupose of street light fitting from DB to street light fittingcomplete all as specified and directed by the Engr-in-Charge.Note : Contractor should be quoted the rate including 20 mm PVC pipe and 3 core PVC insulated copper conductor cableincluding fixing accessories.
58Supply and fixing PVC looping box comprising of 02 Nos Aluminimum bus bar mounted on insulator and one Nos 06 Amps SP MCB complete all as directed with necessary fixing arrangement, nuts bolts, clamps etc including replacement PVC conduit medium grade 4 mtr 20mm dia on pole/ wall including taking down of exiting one
59S&F in repair electronic driver of any make/type suitable for25/30/45/ 60Watt LED Street light. Make- Havells/Crompton/Bajaj/C&S/Philips.
60Supply,install test and comprising of factory made powder coated cubical outdoor LT feeder pillar box of size 900 x 750 x 300 mm confirming to IP-65, CPRI approved complete weather proof and vermin proof and the shell of 3.15 mm thick MS sheet with partitions and switch enclosure doors of 2 mm MS sheet with minimum clearance of 750 mm and canopy made out of 3.15 mm thick MS sheet all as per IS shall be availableinside for easy access and workingcondition fixed on angle iron frame 50 x 50 x 6mm. Mounted on brick masonry pillars with a clearance of atleast 0.45 mtrs above GL on 100mm thick appron of PCC 1;4;8 type D-2 provided 1.0 mtr all around with a slight outward slope to avoid stagnation of water,marking to indentify incoming and outgoing circuits and earthing pillar box at two points out door feeder pillar box comprising of following:- (a)MCCB 100 Amp,4 pole25 KA,415 volt ICU 100% ICS with thermal based release - 01 Nos (b) Timer switch Analog outdoor type factory made powder coated all along internal and external surfaces, weather proof, dust and water proof with I P 55 protection, consisting of 01 No AC contactor 3 pahse 16 Amp capacity 10 KA, one digital Timer switch with 16 Amp three Nos MCB SP 10 Amp 10 KAhaving both auto manual and by pass system - 01 No mounted on existingpanel with suitbale size clamps complete all as specified and directed.Make : : Havells/C&S/L&T /Legrand.
61Taking down old unserviceable PCC pole from site and Supply and fix steel tubular swaged poles type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck all as specified and directed by Engr in Charge. Note : Old PCC poles replaced by Steel tubular pole at site due to site restriction/requirement Make- Mahindra/ Tata/ Bansal
62Taking down ceiling fansof any make,type and size by skilled electrician/mech at site given by JE E/M or Engr in Charge, removing electrical connection,dismantling blades etc, opening ofmotor, cleaning of fan body and blades using detergent, greasing and oiling of serviceable ball bearing, bushes, replacement of Capacitor 2.5/4.00 mfd in slow speed fan,reassemblingmotor and fan, testing and hanging in position, if found unserviceablethe fans shall be seggregated in two categories rewinding required or replacement of ball bearing/gun metal bush requiredthe same will be transported to workshop for repair/rewinding/maint work complete all as specified and directed by Engr in Charge Note:- (i)Rewinding/ replacement of ball bearing or gun metal bushes etc will be measured & paid separately in respective item as mentioned in Schedule of work (ii)The above rates includes the replacement of Capacitor (in slow speed fan) at site (Cost of Capacitor will be measured and paid separately)
63Taking down Exhaust fans of any make,type and size by skilled electrician/mech, removing electrical connection,dismantling blades etc, opening ofmotor, cleaning of fan body and blades using detergent, greasing and oiling of serviceable ball bearing, bushes, reassemblingmotor and fan, testing and hanging in position, if found unserviceablethe fans shall be seggregated in two categories rewinding required or replacement of ball bearing/gun metal bush requiredthe same will be transported to workshop for repair/rewinding/maint work complete all as specified and directed. Note:- Rewinding/ replacement of ball bearing or gun metal bushes etc will be measured paid separately in respective item as mentioned in Schedule of work
64M&L for rewinding of ceiling fan motor 240 volt, 50 Hz, 1200/1400 mm sweep, any make, with super enameled copper winding wire of existing size, same No of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire of suitable size upto connector block complete all as specifiedand directed.
65S&F in replacement of ball bearing 6201/6202/6203 or any other suitable size required in defective ceiling fan of size 1200/1400mm sweep retrieved from Item No 62including testing of fans complete all as specified and directed. Make : SKF/ NBC or equivalent ISI Mark
66S&F in replacement of Gun metal bushes ofsuitable size required in defective ceiling fan of size 1200/1400mm sweep retrieved from Item No 62including testing of fans complete all as specified and directed. Make : SKF/ NBC or equivalent ISI Mark
67Supply only capacitor2.5 MFD of ceiling fan complete all as specified and directed.
68Supply only capacitor 4.00 MFD of ceiling fan complete all as specified and directed.
69M&L for rewinding of exhaust fan motor 240 volt, 50 Hz, 400 to 600 mm sweep, any make, with super enameled copper winding wire of existing size, same No of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire of suitable size upto connector block complete all as specifiedand directed.
70M&L for rewinding of exhaust fan motor 240 volt, 50 Hz, 150-350 mm sweep, any make, with super enameled copper winding wire of existing size, same No of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire of suitable size upto connector block complete all as specifiedand directed.
71S&F in replacement of ball bearing of suitable size required in defective Exhaust fan of size 400 to 600 mm sweep retrieved from Item No 63including testing of fans complete all as specified and directed. Make : SKF/ NBC or equivalent ISI Mark
72S&F in replacement of ball bearing of suitable size required in defective Exhaust fan of size 150 to 350 mm sweep retrieved from Item No 63including testing of fans complete all as specified and directed. Make : SKF/ NBC or equivalent ISI Mark
73S&F in replacement of Gun metal bushes ofsuitable size required in defective Exhaust fan of any type any size/sweep retrieved from Item No 63including testing of fans complete all as specified and directed. Make : SKFNBC or equivalent ISI Mark
74Supply and fixing in replacement of Fan hanging clamp, Locking screw, Blade screw all as directed by Engr-in-Charge.
75Supply and fixing in replacement of Down rod 15 mm dia MS tube 60 cm longall as directed by Engr-in-Charge.
76Supply and fixing in replacement of Down rod 15 mm dia MS tube 90 cm long all as directed by Engr-in-Charge.
77Taking down wall mounted fan of any make, typeand size at site by skilled electrician/mechanic , removing electrical connection, dismantling blades etc, opening ofmotor, cleaning of fan body and blades using detergent, greasing and oiling of serviceablebearing, bushes, reassemblingmotor and fan, testing and hanging in position. If found unserviceable/burnt ,rewinding required,transported to workshop for repair/rewinding/maint complete all as specified and directed.
78M&L for rewinding of wall mounting fan motor 240 volt, 50 Hz, any make, with super enameled copper winding wire of existing size, same No of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia upto connector block complete all as specifiedand directed.
79Supply and fixing in replacement at siteAir circulating wall mounted Fans 230 volts single phase, sweep size 400 mm, high performance motor for better air delivery jerk free oscillation & smooth running, Aerodynamically designed balanced heavy duty PP blades, superior low voltage performance sweep size 400 mm, power input 50 watts, Speed 1360 RPM, Air delivery 72 cmm, etc suitable for mounting on wall.Make- Crompton / Bajaj/Usha/Havells all as specified and directed by Engr in Charge. (Old unsv wall fan to be deposited in MES store Yard for repair/rewinding wk)
80S&F in replacement at site electronic fan regulator 230 volts, step type,switch/socket, hum free, 120 watt type ISI marked complete all as specified.
81Maintenance, servicing and testing of split type/window type AC, capacity upto1.5/2 tons, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters, checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for winter/summer to ensure cutting off of compressor/heating in case of failure of blower motor including taking down and refixing in position complete all as directed by Engineer-in-Charge. Note - Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back is deemed to be inclusive in the unit rates quoted by the contractor.
82S&F, in replacement, new compressor for window type AC 1.5/2Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed. Make: Shriram/ Kirloskar/Voltas/Carrier/Whirlpool
83S&F, in replacement, new compressor hermetic/rotary for split type AC 1.5/2Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed. Make: Shriram/ Kirloskar/Voltas/Carrier/Whirlpool/LG/Samsung
84M&L for finding out leakage with the pressure testing of the condensor/cooling unit/ compressor of window type/Split type AC of 1.5/2.00 Toncap including dismantling the same for recharging with R-22 gas or as per manufacturer"s instruction and stop leakage by brizing/soldering including charging the gas to required level and testing the AC for the entire satisfaction of EIC.
85S&F nylon type filter pad20 micron for window type AC of capacity up to 2 ton including taking out unserviceable filter pad complete all as specified and directed.
86S&F, in replacement, running capacitor 5 MFD 230 volts for blower motor complete all as specified and directed. Make : Keil / Asian /Tesla.
87Supply and fixingstarting capacitor clip type of cap. 80-100 MFD,440 suitable for 1.50 Ton capacity window/Split type AC complete all as directed by Engineer-in-Charge make- Kell/Tesla/Sharda/Escop
88S&F in repairs ofrunning capacitor, 100-120 MFD suitable for 1.5 / 2.00 Ton capacity window/split type AC of approved make.
89S&F, in replacement, starting relay suitable for window type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol.
90S&F, in replacement, over load protection suitable for window type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol.
91S&F, in replacement, thermostat switch suitable for window type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol.
92S&F, in replacement, blower motor 1/8 HP, double shaft, single phase suitable for window type AC up to 2 ton capacity including testing complete all as specified and directed.Make: Khaitan or Universal.
93S&F, in replacement, fan blade for blower motor for window type AC up to 2 ton capacity complete all as specified and directed. Make: Khaitan or Universal
94S&F, in replacement, starting relay suitable for split type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol
95S&F, in replacement, thermostat switch hot & cold product no2KSP-5010 complete all as specified and directed. Make : Indfoss/Renutrol.
96S&F, in replacement, power circuit breaker (PCB) kit for split/window type AC complete all as specified and directed.
97S&F in repair drain out pipe of split type AC complete all as directed by Engineer-in-Charge.
98Attending general complaints and rectification of defects of any type ofAC, Refrigerator, Water Cooler, Deep Freezer, Desert Cooler, Voltage Stabilizer, water purifier etc and testing after complete all as specified and directed. Note :- (i) The complaint shall be notified to the contractor by Engr-in-Charge or JE E/M and recorded in the register maintained for the purpose. (ii) Cost of any minor nature of repair, replacement of petty items such as nuts, bolts, washers, screws, piece of electric cable upto 0.50 metre length etc is deemed included in the unit rate quoted by the contractor.
99S&F, in replacement of voltage stabilizer of capacity2KVA, 230 Volts, AC,for desired voltage output from 135 to 300 Volts and stabilized to 230 volts to 240 volts including testing complete all as specified and directed.
100S&F, in replacement of voltage stabilizer of capacity 5KVA, 230 Volts, AC,for desired voltage output from 135 to 300 Volts and stabilized to 230 volts to 240 volts including testing complete all as specified and directed.
101S&F, in replacement, fan blower motor,single phase suitable for desert cooler including testing complete all as specified and directed. Make: Khaitan/Universal/Pilot.
102M&L for taking down existing unserviceablefan motor from desert cooler andincluding replacement of wornout winding, bushes and bearing etc and testing complete, refixing and connecting complete all as directed by EIC.
103Supply and replacement of Water lifting submersible pump suitable for desert cooleras per existing capacity. (Make : Snow Cool/LITTLE/universal)
104S&F cooler pad made of Khas-Khas suitable for desert coolers including taking out unserviceable pad complete all as specified and directed.
105M&L for replacement of copper conductor cable 40/0.0076 Sqmm 3 core not less than 3 mtrs long with plug top 5 Amp suitable for desert cooler (Make FINOLEX/PARAGUN/POLYCAB).
106M&L for replacement of Fan blade of desert cooler heavy duty HDPE suitable for 4000/5000 CFT cap complete all as directed by EIC.
107Supply, fixing & testing new compressor for water cooler of capacity 40/80 Ltr, deep freezer capacity 200 to 320 Ltr including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make Kirloskar/Copeland/Shriram/Usha /Voltas
108Supply, fixing & testing new compressor for water cooler of capacity 60/120/150 Ltr,including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make Kirloskar/Shriram/Copeland/Voltas
109S&F, in replacement blower motor 1/35 HPwith base and clamp, rubber mountings, fan blade for water coolers including taking out the old unserviceable motorcomplete all directed. Make: Universal/Crompton Greaves/Cool king/ American Universal
110M&L for trickle charging of gas F-12/F-22/134a or as required in water cooler/Deep freezer, any capacity, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contentstrapped in the pipe line by charging CO2 gasand maintaining the pressure forprescribed period complete all specified.
111S&F push type water tap, 15 mm dia, chromium plated suitable for water cooler complete all as specified anddirected.
112S&F, in replacement, thermostat switch suitable for water cooler, any capacity/make including taking down unserviceable thermostat switch complete all as specified and directed. MAKE: SHRIRAM or RANUTROLL or INDOFOSS.
113Supply, fixing & testing new compressor for refrigerator of capacity 286/310 Ltr including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make Kirloskar/Shriram
114M&L for trickle charging of gas F-12/134a or as required in refrigerator of capacity 260/286/310 Ltr, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contentstrapped in the pipe line by charging CO2 gasand maintaining the pressure forprescribed period complete all specified.
115S&F, in replacement starting relay for refrigerator of different capacity/make including taking out unserviceable relaycomplete all as specified anddirected.Make : SG-8 orRenutrol orK.C.U 7
116S&F, in replacement thermostat switch for refrigerator of different capacity/make including taking out old unserviceable thermostat switch complete all as specified anddirected. MAKE: SHRIRAM orRENUTROL or INDOFOSS.
117Repair of voltage stabilizer of capacity upto 2 to 5 KVA, AC, SP 230 Volts for rewinding of main transformer using super enameled copper winding wire of guage equal to existing replacing insulation sheet, sleeve, varnishing the same & repair/replacement to electronic circuit including auto cut relays for desired voltage output from 135 to 300 Volts and stabilized to 230 volts to 240 volts including replacement of unserviceable Volt meter, Amp meter, MCB 20/32 Amp, indicator lamp, main lead 3 metre long, 3 core 40/.0076, fuse grip, output connection including testing complete all as specified and directed.
118Taking down Geyser of any capacity from existinglocationby skilled Electrician/Mechanic at site given by Engr in Charge/JE E/M , cleaning/descaling of inner tank & assembly with wire brush, sand paper and with fresh water , detecting leakages from inner tank, appartus assembly, joints of Hot & Cold pipe etc if any, including refixing the geyser in position tightening the nuts, bolts, washer, connector etc testing complete for smooth functioning or iffound unserviceablethe geysers shall be segregated in following categories (a) replacement of heating element required (b) replacement of thermostat required (c) Replacement of assembly required (b) replacement of inner tank required (e) Brazing/soldering/gas welding required in inner tank and the same will be transported to workshop for repair/maint work complete all as specified and directed by Engr in Charge. Note : The item rates include the cost of minor spares, wires nuts, bolts, washer etc required at site and replacement of indicator lamp at site(Cost of indicator lamp will be measured and paid separately)
119Supply and fixing in replacement of Heating element 1500 Watt (any type,any make, any size as per sample suitable for normal/ star rated geysers of reputed make) including testing and fixing of geyser atexisting location all as specified and directed by Engr in Charge Make : Renutrol/Theta/Bajaj or equivalentall as specified
120Supply and replacement of Heating element 2000 Watt (any type,any make, any size as per sample suitable for normal/ star rated geysers of reputed make) including testing and fixing of geyser at existing locationall as specified and directed by Engr in Charge Make : Renutrol/Theta/Bajaj or equivalentall as specified
121S&F apparatus assembly complete with incoming /out going brass pipe complete with gasket, nuts, bolts, washers etc as required for fitting in 25 ltrcapacity geyserincluding testing and fixing of geyser atexisting locationall as specified and directed by Engr in Charge.
122S&F apparatus assembly complete with incoming /out going brass pipe complete with gasket, nuts, bolts, washers etc as required for fitting in 50 ltrcapacity geyser including testing and fixing of geyser atexisting locationall as specified and directed by Engr in Charge.
123Supply and fixing in replacmentthermostat for Geyser of capacity 50 Ltr/25 Ltr of any make/type/or as per sampleincluding testing and fixing of geyser atexisting locationall as specified and directed by Engr in Charge. Make : Renutrol/Theta/Bajaj or equivalent
124Supply onlyIndicator lamp square type/round type/rectangular type as per existing at site, 220 volts complete all as specified.
125Taking out the worn out inner tank of Geyser of capacity 50 Ltr and supply and fixin replacement copper inner tank ISI mark with existing model, making good with the insulating glass wool including testing and fixing of geyser atexisting locationall as specified and directed by Engr in Charge
126Taking out the worn out inner tank of Geyser of capacity 25 Ltr and supply and fixin replacement copper inner tank ISI mark with existing model, making good with the insulating glass wool including testing and fixing of geyser atexisting locationall as specified and directed by Engr in Charge
127M&L for brazing/copper gas welding/solderingetcthe inner tank of any capacity and making the Geyser leak proof and testing after filling with fresh water, including testing and fixing of geyser atexisting locationall as specified and directed by Engr in Charge.
128M&L for shifting the Geyser of any capacity from one location to other location by grouting with fastener, nuts, bolts etcall as specified and directed by Engineer-in-Charge.
129Supply and fixing stop cock brass of size 15 mm dia Make- Sant/Leader/BVI
130Supply and fixing bib cock brassof size 15 mm diaMake- Sant/Leader/BVI
131Supply, laying, fixing GI pipe medium class 15 mm dia including all fittings like elbow/union etc, by cutting wall and connecting on existing 15/20mm dia GI pipe complete all as specified and directed. Make- Tata/Jindal/Ravindra
132S&F in replacement PVC connection hot and cold water pipe 18" long, 15mm outer dia with brass jem nut and washer, both side complete all as directed by Engineer-in-Charge.
133S&F in replacement PVC connection hot and cold water pipe 18" long made of chromium plated brass flexible tubing.
134Scraping of old painted surfaces of Geyser & making smooth surface for painting & applying one coat of white synthetic enemelled paint over the body of Geyser 50/25 litre capacity.
135Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 9 KA,240 volt.
136S&F in replacement switch socket combination 2 in 1, 6 pin, 5 & 15 Amp, Flush type complete all as specified. Make : Anchor/SSK/Leader
137S&F in replacement 3 pin top plug , 15 Amp press type with and including 1.5 mtr copper conductor lead of 40/0.0076, 3 core, complete all as specified. Make : Anchor/SSK/Leader
138S&F, in replacement, power circuit breaker (PCB) kit for refrigerator of capacity 286/310 Ltr complete all as specified and directed.
139Repair/maint/servicing/overhauling of 500 LPD Flat Plate Solar water heating System installed at 2 ASD at Beas mil stn including descaling with chemical, checking electrical connection and minor repair/ spares, electrical wires, nuts bolts, clamps etc required at site for making functional to the existing solar water heating all as specified and directed by the Engr in Charge/GE. Note - Other spares relevant to this item will be measured and paid separately .
140Suppy and fix in replacement the following spares of the solar water heating system as to be used while servicing and repair on above items :-
141(a)U Rubber
142(b)Round Gasket
143(c)D Scale chemical
144(d)Black board paint
145(e)Acid
146(f)Glass cleaners solution
147(g)Electrical heating element
Disclaimer :