Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #30078874

Repair And Maintenance To Battery Chargers Frequency Converter Rectifier And Allied Works At Various Location Under Ge Af Marathahalli Bangalore Repair And Maintenance To Battery Chargers Frequency Converter Rectifier And Allied Works At Various Location

Issued by Statutory Bodies & Commissions/Committees · GE (AF) MARATHAHALLI, Karnataka
Tender Value
11.90 Lakhs
Estimated cost
Bid Submission
23 Dec 2021
0 days left
EMD
23800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
GE (AF) MARATHAHALLI → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair And Maintenance To Battery Chargers Frequency Converter Rectifier And Allied Works At Various Location Under Ge Af Marathahalli Bangalore Repair And Maintenance To Battery Chargers Frequency Converter Rectifier And Allied Works At Various Location Under Ge Af Marathahalli Bangalore

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Dec-2021 DATE POSTPONEMENT CORRIGENDUM Date 23-Dec-2021
2 10-Dec-2021 OTHER CORRIGENDUM3 Other 23-Dec-2021
3 10-Dec-2021 BOQ CORRIGENDUM_2 BOQ 23-Dec-2021

BOQ

Name of Work : REPAIR / MAINTENANCE TO BATTERY CHARGERS, FREQUENCY CONVERTER RECTIFIER AND ALLIED WORKS AT VARIOUS LOCATION UNDER GE (AF) MARATHAHALLI BANGALORE.
Sl. No. Item Description
1Comprehensive maintenance for theBattery chargers 6V/5A CapacityQty -2 nos ,complete checking PCB , circuits , panels , battery leads , selectorswitches , voltage adjusters ,volt meters , Ampeare meters and replacing unserviceable parts. The following checks to be carried out to ensure smooth and effective operation of Battery chargers (a) Checking control panel, power supply,indicators, fuses, circuits and voltage adjusters once in Three months(b) Functional checking input and out put voltage , Ampears .(c) Checking of Leads, connectors, servicebility of equipment(d) Maintainance will be carried out once in three months .
2All as per item No 1 above but Battery charger12v/15 Amps qty. -01 Nos at BCR room ASTE complete all as specified and as directed.
3All as per item No 1 above but Battery charger12v/30 Amps qty. -03 Nos at BCR room ASTE complete all as specified and as directed.
4All as per item No 1 above but Battery charger12v/60 Amps qty. -03 Nos at BCR room ASTE complete all as specified and as directed.
5All as per item No 1 above but Battery charger 24 V/60 Amps qty. -03 Nos at BCR room ASTE complete all as specified and as directed.
6All as per item No 1 above but Battery charger 30V/50Amps qty. -03 Nos at BCR room ASTE complete all as specified and as directed.
7Comprehensive maintenance of Frequency converter 20 KVA capacity ,3 phase & neutral , phase to phase voltage 415 v ,50 Hz and out put voltage200v, 400 Hz and replace the u/sminorparts.complete checkingtransformers , circuits , internal wiring PCB boards, in put and out put voltages and frequency. QTY- 02 Nos. NOTE :(i)major parts will be measered and paid separately.(ii) Maintainance will be carried out once in threemonths .
8All as per item No 7 above but Frequency converter 10 KVA capacity ,3 phase & neutral , phase to phase voltage 415 v ,50 Hz and out put voltage200v, 400 Hz, qty. -02 Nos
9Comprehensive maintenance of Wave rectifier 4 KW capacity and replace the u/sminorparts.complete checkingtransformers , circuits , internal wiring PCB boards, in put and out put voltages and frequency. QTY- 02 Nos complete all as specified and as directed.NOTE :(i)major parts will be measered and paid separately.(ii) Maintainance will be carried out once in threemonths .
10All as per item No 9above but Wave rectifier 2KWcapacity, qty. -02 Nos complete all as specified and as directed.
11All as per item No 9 above but Wave rectifier 1KWcapacity, qty. -02 Nos complete all as specified and as directed.
12Comprehensive maintenance of Heat converter 2 KW capacity and replace the u/sminorparts.complete checkingtransformers , circuits , internal wiring PCB boards, in put and out put voltages and frequency. QTY- 07Nos complete all as specified and as directed.NOTE :(i)major parts will be measered and paid separately.(ii) Maintainance will be carried out once in threemonths .
13Testing checking and calibration of battery charger unit including replacement of PCB and transformer complete with carrying the workshop after disconnetion and refixing the same after back to the workshopall as specified and directed .( Note :- spares will be measured and paid separately)
14M & L for sub main wiring complete with two runs of 10 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 6 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
15M & L for sub main wiring complete with two runs of 4 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
16Supply and replace PCB Board M12R-1 complete all as specified and as directed.
17Supply and replace voltage selector switch complete all as specified and as directed.
18supply and replacement of Motor for fequency converter complete all as specified and as directed.
19Supply and replace currentselector switch complete all as specified and as directed.
20Supply and replace Mosfet IRFP-460 complete all as specified and as directed.
21Supply and replace MosfetFEP 30 DP complete all as specified and as directed.
22Supply and replacePCB Card Charger Bank component complete all as specified and as directed.
23Supply and replace Arvi 112 PS VO PCB component complete all as specified and as directed.
24Supply and replace Arvi 139 Card component chargers for PCB card complete all as specified and as directed.
25Supply and replace Senseing Transformer complete all as specified and as directed.
26Supply and replace Fan 4inch AC complete all as specified and as directed.
27Supply and replace PCB card complete all as specified and as directed.
28S & F MCB SPN 40Amps, \"C\" series, 240 V complete incl making conections all as specified and directed.
29S & F MCB SP 6-32 Amps, \"C\" series, 240 V complete incl making conections all as specified and directed.
30S & F MCB TPN 63 Amps incl making connections acomplete all as specified and as directed.
31S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1 No.Double poleMCB 20 Amp capacity complete all as specified and as directed
32S&F in replacement Triple pole and neutral enclosure with Threepin and earth plug and socket including 1 No.Triple pole MCB 32Amp capacity complete all as specified and as directed
33S&F in replacement Triple pole and neutral enclosure with Threepin and earth plug and socket including 1 No.Triple pole MCB 63Amp capacity complete all as specified and as directed
34Supply and fix in replacement MCCB TPN 415 Volts 160 Amps,beaking capacity25 kA complete with making all connections as specified and directed.
35Supply and fix in replacementMCCB TPN 415 Volts 100 Amps, beaking capacity 25 kA complete with making all connections as specified and directed.
36All as per ser item no.34 here-in-before but MCCB TPN 415 Volts 63 Amps,beaking capacity 25 kA complete with making all connections as specified and directed.
37All as per ser item no.34 here-in-before but MCCB TPN 415 Volts 32Amps,beaking capacity 25 kA complete with making all connections as specified and directed.
38S & F MCB DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed.
39S & F MCCB DB VerticalTPN 8 Way\"A\" Frame,Including MCCB TPN 125 Amp Beaking capacity 25Ka -01 nos,Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed.
40Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 voltsLT grade of cross-sectionalarea 50 Sqmm 3.5core laid in trenches/through pipein road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etcsupplied, fixed/ laid in repair including commissioning and testingcomplete all as specified and as directed .
41Material & labour for fixing of Earth continuity conductor Copper strip of size 20 X 3.15 mm with brazing at joints , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles,equipments or any other indicated situation for loop earthing etc, copper strip fixed onwith epoxy insulatorof suitable size all as specified and directed by Engineer-in-Charge.
42M & L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 5 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15cm c/c both way for cover and MS frame etc., complete all as specified.
43Material and labour for earthing complete with Copperearth plate electrode 600 X 600 X 3. 15 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to copperearth strip 20 x 3 mm thickby means of with brazing at joints and connecting to testing point including provision of test point, test point terminal block made of gun metal or phosphorus bronze size 75x75x25mmand all as shown in electrical plate No. 3 of SSRPt I.The work is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 CTD bar reinforcement both ways at 140 mm centre to centre complete all as directed .Notes:- (i) copper stripbeyond 7.5 M shall be measured and paid separately under relevant items of this schedule.

AI Tender Summary

OUR REF NO 30078874
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 11.90 Lakhs
LAST DATE 23-12-2021
Authority
Authority Name Military Engineer Services
Work Description Repair And Maintenance To Battery Chargers Frequency Converter Rectifier And Allied Works At Various Location Under Ge Af Marathahalli Bangalore Repair And Maintenance To Battery Chargers Frequency Converter Rectifier And Allied Works At Various Location Under Ge Af Marathahalli Bangalore
Basic Detail
Tender No 8921/E8
Bidding Type Tender
Location
City GE (AF) MARATHAHALLI
State Karnataka
Key Dates
Publish Date 10 Dec 2021
Submission Date 23 Dec 2021
Open Date 22 Dec 2021
Finance
Tender Value 11.90 Lakhs
Tender Fee 500
EMD 23800
Exemption Not Available
Document List
f4c876d7-a0be-4f3b-9a48-6dda4a97b509.html
BOQ_548167.xls
Tendernotice_1.pdf
TENDER8921.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 10, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 23, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 23, 2021
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 23, 2021
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 23, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 22, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

f4c876d7-a0be-4f3b-9a48-6dda4a97b509.html

xls

BOQ_548167.xls

pdf

Tendernotice_1.pdf

pdf

TENDER8921.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders