Mtc. Of Sabroom St Boys Hostel Attached With Sabroom H.S School Sh Construction Of Underground R.C.C Water Tank, Mtc Of Broken Door And Window, Pipeline And Broken Gci Roof Leakage During The Year 2021 2022 Mtc. Of Sabroom St Boys Hostel Attached With
Tender Overview
Project Description
Mtc. Of Sabroom St Boys Hostel Attached With Sabroom H.S School Sh Construction Of Underground R.C.C Water Tank, Mtc Of Broken Door And Window, Pipeline And Broken Gci Roof Leakage During The Year 2021 2022 Mtc. Of Sabroom St Boys Hostel Attached With Sabroom H.S School Sh Construction Of Underground R.C.C Water Tank, Mtc Of Broken Door And Window, Pipeline And Broken Gci Roof Leakage During The Year 2021 2022
BOQ
| Sl. No. | Item Description |
| 1 | Clearing jungle including uprooting of rank vegetation,grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.-All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers notexceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-All kinds of soil |
| 4 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -- All work upto plinth level:a) 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth levela) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-a)1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor fivelevel excluding cost of centring, shuttering, finishing and reinforcement-a)1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding allcomplete upto plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more |
| 10 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding allcomplete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 11 | Centering shuttering including struttings, propping etc. and removal of form work for:Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply |
| 12 | Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 13 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 14 | Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 15 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-a)In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 16 | First class brick work in foundation and plinth including cost of all materials as required complete:-a)In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 17 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gussetplates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:-a)Using M.S. angels 40x40x6 mm for diagonal braces |
| 18 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:a)In grating, frames, guard bar, railing, brackets, gates and similar works, all complete. |
| 19 | Cement concrete flooring 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. completeA)40 mm thick with 20 mm nominal size stone aggregate |
| 20 | 12 mm cement plaster of mixa)In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 21 | 15 mm cement plaster on the rough side of single or half brick wall of mix:a)In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 22 | Neat cement punning. |
| 23 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade[Payment shall be made after submission of Test Certificate issued by the Manufacturer] :a)New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 24 | Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface complete.Water thinnable cement primer |
| 25 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture[Payment shall be made after submission of Test Certificate issued by the Manufacturer] :a)New work ( two or more coats applied @ 3.84 kg/10 sqm) |
| 26 | Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inchx 9 feet ), nuts & bolts etc. for irrection of the same by1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and paintingtwo ormore coats & plastic paint as per specification and direction of the Engineer-in-charge. |
| 27 | Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I.fittings and clamps, including cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.Internal work - Exposed on wall.a) 15 mm dia. nominal bore. |
| 28 | 25 mm dia. nominal bore. |
| 29 | 40 mm dia. nominal bore. |
| 30 | Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I.fittings including trenching and refilling etc. complete as per CPWD specification and direction of the Engineer - in - charge.External work15 mm dia. nominal bore. |
| 31 | 25 mm dia. nominal bore. |
| 32 | 40 mm dia. nominal bore. |
| 33 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 34 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore |
| 35 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :15 mm nominal bore. |
| 36 | 25 mm nominal bore. |
| 37 | 40 mm nominal bore. |
| 38 | Providing and fitting fixing of brass fullway valve with handle in theGI pipe line including cutting, threading etc. complete as per chapter 20 of CPWD specification and direction of the ngineer - in - charge.a) 40 mm nominal bore. |
| 39 | Providing & Installation of Centrifugal Monoblock type single phase pump moror setwith all eccessary equipementsof Crompton / Kirloskarmake in/c providing fitting fixing by necessary rubber washer, nuts & bolts,etc. as per required size and making necessary electrical connection with main switch in/c Commissioning & trial run as per direction of the Engineer-in-charge .a) 2 H.P. Monoblock Single PhaseCentrifugal pump. of 1.50 K.W., 3000 R.P.M, 210-130 L.P.M. Discharge, 24-32 metres head range. |
| 40 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): a) 40 mm nominal bore . |
| 41 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conformingto IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :a)White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 42 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 markedwith cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 43 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats completea) 25mm nominal bore. |
| 44 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste ofstandard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :a)White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 45 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :a) Of area 3 sqm and below. |
| 46 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired doorshutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge |
| 47 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metresheight including stacking the material within 50 metres lead :b) Of sectional area beyond 40 sq cm .. |
| 48 | Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished / black enamelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the wooden beading of 20 × 12 mm for fixing panelling and or glazing as per direction of Engineer-In-Charge.Local Teak wooda) 30 mm thick shutters |
| 49 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :a) Karai wood. |
| 50 | Providing and fixing IS : 1341 marked M.S. heavy weight butt hinges with necessary screws etc. complete :a) 125 × 90 × 4.00 mm. |
| 51 | Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc. completea)250 x 16 mm |
| 52 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :a)200 x 10 mm |
| 53 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. completea) 100 mm. |
| 54 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts,nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size |
| 55 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square orround bars etc. all complete.a) Fixed to openings /wooden frames with rawl plugs screws etc. |
| 56 | Renewingglasspanes,with puttyand nailswherever necessary including racking out the old putty: Float glass panes of thickness 4 mm |
| 57 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast /anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required. |
| 58 | ProvidingcorrugatedG.S.sheetroofingincludingvertical/curved surface fixedwithpolymercoatedJorLhooks,bolts andnuts8mm diameterwithbitumenandG.I.limpetwashersorwithG.I.limpet washersfilledwithwhiteleadandincludingacoatofapprovedsteel primerandtwocoatsofapprovedpaintonoverlappingofsheets complete(uptoanypitchinhorizontal/verticalorcurvedsurfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63mm thick with zinc coating not less than 275gm/m2 |
| 59 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63mm thick with zinc coating not less than 275gm/m2 |
| 60 | Providing and fixing flat pressed 3 layer medium density particle board or graded particle board (Grade I)IS: 3087 marked in ceiling with necessary nails etc. complete (frame work to be paid separately):12 mm thick |
| 61 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :a)New work (two or more coats) including a coat of appropriate steel primer but excluding a coat of mordantsolution |
| 62 | Painting on G.S. sheet with synthetic enamel paint ( one or more coats ) of approved brand and manufacture of required colour to give an even shade on old work including preparation of surface as required complete as per direction of the Engineer in charge:- |
| 63 | Applying priming coat [Payment shall be made after submission of Test Certificate issued by theManufacturer] :i) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanisediron/ steel works |
| 64 | With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ). |
| 65 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Two or more coats on new work |
| 66 | Painting on wood work with oil type wood preservative ( two or more coats) of approved brand andmanufacture on new work complete. |
| 67 | Painting on wood work with oil type wood preservative ( one or more coats ) of approved brand andmanufacture on old work including preparation of surface as required complete as per direction of theEngineer in charge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender