Revival & Energisation Of Nagapur L.I.Project In Balianta Block Of Khordha District Under Plan Fund 2020-21
Tender Value
9.78 Lakhs
Estimated cost
Bid Submission
06 Dec 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
4000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
BALIANTA → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Revival & Energisation Of Nagapur L.I.Project In Balianta Block Of Khordha District Under Plan Fund 2020-21
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation of foundation in hard soil including rough dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. |
| 2 | Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge. |
| 3 | Cement concrete (1:4:8) with 4cm size black hard granite( HB ) metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty conveyance charges of all materials to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge. |
| 4 | Cement concrete (1:2:4) with 12mm size black hard granite ( CB ) chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty conveyance charges of all materials to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge. |
| 5 | Brick work with K.B. Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the direction of the Engineer-incharge. |
| 6 | 12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as per the direction of the Engineer-incharge. |
| 7 | Rigid smooth centering & shuttering for R.C.C. Works walls & fins including false work & dismateling them after 28 days of curing including cost of materials in ground floor complete as per the direction of the Engineer-incharge. |
| 8 | R.C.C. work in C.C. (1:2:4) with 12mm size black hard granite ( CB ) chipsof approved quality from approved quarry including hoisting & laying with ramming watering and curring etc. complete including cost, taxes, royalty conveyance charges of all materials to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge. |
| 9 | Labour charge for M.S. reinforcement for R.C.C. work including cutting, bending & tying the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD SteelBar (FE 415/ FE 500) |
| 10 | Cement punning over plastering including watering and curing with cost, taxes, royalty conveyance charges of all materials to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge. |
| 11 | Filling the foundation and plinth with excavated material as per the direction of the Engineer-incharge. |
| 12 | Painting 2 coatswith approved paintincluding cost conveyance charges of materials including supply of labouretc. required for the work complete as directed by the Engineer-incharge. |
| 13 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge. |
| 14 | Fitting of un plasticised 200mm diaPVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-heat application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge. |
| 15 | Fitting of un plasticised 160mm diaPVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-heat application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge. |
| 16 | Supply of solvent cement of approve quality for joiniting of PVC Pipe with all cost and all tax etc. complete as per the direction of the Engineer-incharge. |
| 17 | Labour charges for Lowering of 10 HP S/S pumpset including all accessories etc |
| 18 | Fabrication of specialjoint including cutting and weldingof pipes out ofM.S. pipe / 100mm dia G.I.pipe including welding of flange at one end and other end suitable for connection to delviery pipe lines of pump sets including cost of cutting and welding, materials and fitting it in proper alighmentwith the deivery pipe line of pump sets etc. complete. |
| 19 | Construction of outlet at Tank |
| 20 | 100 mm Ø nominal bore G.I. pipehaving wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name / Trade mark. |
| 21 | 100 mm dia G.I. bendIS No.1239(Part-II/1992) |
| 22 | 100 mm dia G.I. flange IS No.6392 / 1971 |
| 23 | 100 mm dia G.I.Socket |
| 24 | Cost of 100 mm dia MS Clamp |
| 25 | Cost of 12mm dia PVC Insulated Steel Wire rope |
| 26 | 200x100mm dia MS TW cap |
| 27 | Cost of 10HP S/S pumpset |
| 28 | Supplying of 200mm diaunplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS - Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I UPVC pipe to withstand pressure of 2.5 kgf/sqcm & the specificationand manufacturer name should be prominently marked on body of each pipe as per the latestAmendment of IS - 4985.It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained fromCIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape. |
| 29 | Supplying of 160 mm diaunplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS - Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I UPVC pipe to withstand pressure of 2.5 kgf/sqcm & the specificationand manufacturer name should be prominently marked on body of each pipe as per the latestAmendment of IS - 4985.It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained fromCIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape. |
| 30 | C I double flanged 100mm Non-return valve swing type PN - 1.0 as per IS:5312 part-I with by-passarrangement |
| 31 | C I double flanged 100mm Sluice ValveFlanged type PN - 1.0 as per IS:5312 part-I with by-passarrangement |
| 32 | 50 mmØ Air release valve with saddle & Raiser pipe. The air release valve shall confirm to IS 14845 with ISI mark. |
| 33 | 200 mm x200 mm x160 mm Ø PVC ReducingTee(W.P. 4 kgf/cm2) confirming to IS-4995/1988 with latest ammendment |
| 34 | 200 mm Ø PVC End Cap (W.P. 10 kgf/cm2) confirming to IS-4995/1988 with latest ammendment |
| 35 | 200 mm Ø PVC coupler (4 kg/cm2) Agricultural PVC fittings confirming to IS-4995/1988 with latest ammendment |
| 36 | 200 mm x200 mm x200 mm Ø PVC Equal Tee(W.P. 4 kgf/cm2) confirming to IS-4995/1988 with latest ammendment |
| 37 | 160 mm x160 mm x160 mm Ø PVC Equal Tee(W.P. 4 kgf/cm2) confirming to IS-4995/1988 with latest ammendment |
| 38 | 160 mm Ø PVC End Cap (W.P. 10 kgf/cm2) confirming to IS-4995/1988 with latest ammendment |
| 39 | 200x100 mm dia PVC reducer |
| 40 | 160 mm Ø PVC coupler (4 kg/cm2) Agricultural PVC fittings confirming to IS-4995/1988 with latest ammendment |
| 41 | 5/8 \" x12\" Nut bolt & washer F.T. for foundation |
| 42 | 5/8 \" x3\" Nut bolt F.T. as per IS specification |
| 43 | 1/2\" x2 1/2\" Nut bolt F.T.as per IS specification |
| 44 | ?\" thick Rubber Insertion as per IS specification |
| 45 | 200 mmx100 mm PVC/G.I./M.S. Reducer |
| 46 | Cost of 150 mm dia Butterfly Valve |
| 47 | 160 mm x160 mm x100 mm Ø M.S.Raiser Tee set withbend , closing and opening arrangement. |
| 48 | Control Pannel with Automatic Star delta Starter, sheetsteel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp &no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt Meter,Ameter,MCB in complete shape including Indicator Lamp. |
| 49 | 63 Amp Main Switch Triple pole & neutral of voltage range 440 volt of re-wirable fuse and shall confirm to IS 4064 part I & with ISI mark. |
| 50 | Base frame for panel (size 0.40mx0.20m) made with 3\" size M.S. channel having suitable holes for fitting of panel Board, coloured with one coat of red oxide primer and two coats of smokes grey enamel paint & Base frame for motor (size 0.50mx0.27m) made with 3\" size M.S. channel having suitable holes for fittings of different size and make 3 phase centrifugal monoblock pump set from 10 H.P. to 15 H.P. coloured with one coat of red oxide primer & two coats of smoke grey enamel paint. |
| 51 | 5 KVAR Power shunt Capacitor |
| 52 | 3 x 10 sqmm Tropodar cable XLPE (Cross link polyethylin) conforming toIS: 7098 (Part-II)includinglaying below .9mtr. ofthe ground and filling the excavated materials including watering and ramming. |
| 53 | Cost of 300 mm R.C.C. hum pipe( NP 3 )as per specificationsincluding laying & fitting |
| 54 | Electrical installation with electrical materials such as PVC tape,ampere tape,7/20 & 3/20 PVC copper wire,G.I flexible condute pipe,No.6 G.I wire copper cable socket and flange and petty materials etc.All matrials are as per IS. Specification |
| 55 | Electrical Earthing including all materials as per the direction of the Engineer- incharge |
| 56 | Cost of TW Safe quard |
| 57 | Installation of 25 KVA,11/.4 KV Pole mounted Sub-Station using 9 Mtr long PSC POLE WITH Star Ratted Transformer as per the specification & estimateetccomplete as per the direction of the Engineer-incharge. |
| 58 | Construction of boundary wall of size 15\" x 10\" withsand filling and metal spreading, fixing of iron grill gate etc. as per direction of Engineer-incharge and TDCOL specification. |
| 59 | Construction of 11 K.V. Line 3 Ph 3 Wire with 9 mtr long 300 kg PSC pole using 55sq.mm lnsulated Cocductor 60 mtr span with all materials required for the same as per the specification andestimate ofTDCOL etc. |
AI Tender Summary
Tender Timeline
Nov 27, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedDec 06, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 07, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender