Military Engineer Services-MES has published Repair Door Window Replacement Of Wooden Window Aluminium Windows Certain Bldgs Nofra I Ii Repair Replacement Ext Water Sup Ci Gi Pipe Line Valve Connected Item Sewage Treatment Plant Pipe Line Fire Fighting Pipe Line Under Ge Gomantak Vasco Repair Door. Submission Date for this Tender is 22-12-2021. Pipe Laying Tenders in VASCO DA GAMA Goa. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Dec-2021 | revisedboq | BOQ | 15-12-2021 |
2 | 15-Dec-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-12-2021 |
Sl. No. | Item Description |
1 | Sche "A" Part -I : BR-I Portion |
2 | Taking down of chowkat or frame area exceeding 1.5 Sqm and not exc. 4.0 Sqm each with shutter (without taking off shutters from frames) and moving off site. |
3 | Taking down chawkhat or frame n. exc 1.50 Sqmeach with shutters (without taking off shutters from the frame). |
4 | Taking down shuttersof any description exc 1 sqm but n. exc 2 sqm each |
5 | M&L forming jambs etc to opening including cutting toothing and properly bonding into old work including facing and plastring to match existing work incement mortar 1:6 etc. complete. |
6 | M&L preparing of new plastered surface, of wall, applying a layer of 3mm thick Birla white wall care putty on wall and applying two coat of oil bond distember complete all as specified and directed |
7 | S &F 2nd class H/W Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at junctions all as specified. |
8 | Supply & fix 2nd class hard wood 35 mm factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated |
9 | Supplied and fitted 2nd class H/W 35 mmfactory made Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. |
10 | M & L for two coat of sythetic enamel paint over one coat of primer on new wooden suface including prepation of surface exc. 10 cm width and girth. |
11 | S & F PVC solid factory made door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tubecomplete all as specified and directed .Make : “SYNTEX/RAJSHREE Plastic wood Forex, Indore.” |
12 | S & F factory made solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MSframe shall be covered with heat moulded plain colourPVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as shown in SSR Part – I 2009 and as directed by GE/Engineer-in-Charge Make : “SYNTEX/RAJSHREE Plastic wood Forex, Indore.” |
13 | S & F butt hinges medium weight cold rolled mild steel 100 mm long (isi marked) |
14 | S&F aluminium anodized, barrel tower bolt of extruded section, 150 mm (ISI marked). |
15 | S & F 150 mm long Aluminium handles, cast type (ISI marked). |
16 | S&F alumiunium allloy, anodized, sliding door bolt, 300 mm, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed (isi marked). |
17 | S & F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 fixed with fasteners. |
18 | M & L granite tiles as in cill 15 to 18 mm thick embeddedand jointed with grey cement slurry and pointed with white cement with admixture of pigment to match laid on 10mm CM (1:4) including making good the surfaces and half rounding to inner edges. |
19 | M&L preparation of new steel surfacesof any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide Zinc chromeprimer complete all as specified. |
20 | M&L for applying two coats of acrylic emulsion exterior paint (Anti fungal paint-APEX) over a coat of primerto match the existing colour including preparation of newly plastered surface. |
21 | S&F aluminium powder coated frame and shutters for patition / windows/ ventilators/doors sliding/fixed/openable type complete with necessary fittings such as two aluminium handle cum lock for each window, roller etc and fixing all as speciefied and directed by Engineer-in-Charge. |
22 | S&F glazing with 4 mm thick sheet glass ordinary type including rubber beddings/gasket around glass panes all as specified. |
23 | S&F glazing with 4 mm thick figured glass ordinary type including rubber beddings/gasket around glass panes all as specified. |
24 | S&F aluminium anodised wire mesh of size 1.5 mm x 3 mm mesh 20 Gauge thick of make M/S Kiran Netting or equivalent as approved by GE. |
25 | S & F spring for door mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete. |
26 | S&F over all length of cover plate150mm, Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring,fixed in floor. |
27 | M&L weldingfor repairs to doors/ windows/ventilators, rolling shutters etc.exc 2.5cm but n.exc 5cm in length, thickness of metal to be welded not exc 6 mm complete all as specified and directed . ( Note:- Taking down the article and refixing in position after welding shall be measured separately). |
28 | Sche "A" Part -II : E/M Portion |
29 | Supply and laying/fixing of 20 mm dia CPVC pipes SDR 13.5 and plain CPVC SDR 11 fitting on wall/ ceiling or laying in trenches , floor complete all as specified. |
30 | All as per item No 27 above but 25 mm dia pipe |
31 | All as per item No 27 above but 40 mm dia pipe |
32 | All as per item No 27 above but 50 mm dia pipe |
33 | Supply and laying GI tubings medium grade dia ISI Mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trench/wallfor the 100 mm dia all as specified and directed by Engr-in-charge . |
34 | All as per item No 31 above butGI tubings medium grade dia 80 mm |
35 | All as per item No 31 above butGI tubings medium grade dia 50 mm |
36 | All as per item No 31 above but GI tubings medium grade dia 40 mm |
37 | All as per item No 31 above butGI tubings medium grade dia 25 mm |
38 | All as per item No 31 above butGI tubings medium grade dia20 mm |
39 | Supply and laying UPVC Pipes (SCH-80)with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trench/wallfor the 65` mm dia all as specified and directed by Engr-in-charge. |
40 | All as per item No37 above but 50 mm bore pipe. |
41 | All as per item No37 above but 40 mm bore pipe. |
42 | All as per item No37 above but 20 mm bore pipe. |
43 | Taking up or down steel tubing and connection cleaning/removing blockege including fitting and refixing the same on any position/root etc complete for 20 mm bore of pipes all as spd. And directed by Engr-in- charge. |
44 | All as per item No 41 above but 25 mm bore pipe. |
45 | All as per item No 41 above but40 mm bore pipe. |
46 | All as per item No 41 above but50 mm bore pipe. |
47 | Maintenance of Chamber coverincluding wellding of allbroken hindgesandpaintone coat of redoxide then one coat of existing collour all as specified and directed by Engr-in-charge |
48 | M & L forPainting of any size ofpipe linewith connected items in pump housefrom sump to over head pipe lineas per existing colour (Suction/delivery/washout/overflow pipe line) complete all as specified and directed by Engr-in-charge. |
49 | Supply and laying CI pipes with spigot and socket ends centrifugally cast class LA in any length, laid in treanches for the following sizes including taking down of existing old CI pipe complete all as per specified and directed by Engineer in charge. |
50 | (a) 80 mm bore pipe |
51 | (b) 100 mm bore pipe. |
52 | Excavating in trenches n exe 1.5 m wide and notexceeding 1.5 m in depthgetting out hard/dense soil for laying of GI pipe complete includidng taking down of old GI tubing complete all as directed by Engr-in-charge |
53 | Excavating in trenches n exe 1.5 m wide and notexceeding 1.5m in depth for removing and laying G.I tubing and getting out in soft/disintegrated rock. |
54 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil and soft/disintegrated rock. |
55 | Removal of excavated material soil/rock to a distance not exceeding 50 m and depositing where directedby Engr-in-charge. |
56 | Supply and Fixing Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe of 20 mm bore sizes complete all as per spd and directed by Engineer-in-charge.Make : Leader, Bajaj |
57 | All as per item No 52 above but 25mm. |
58 | All as per item No 52 abovebut 40 mm. |
59 | All as per item No 52 above but50 mm. |
60 | All as per item No 52 above but65 mm. |
61 | All as per item No 52 above but80 mm. |
62 | Material and labour for heavy duty sluice valve complete with iron wheel conforming to IS 1969 double flanged and drilled endprovided with high tensile steel spindle including GI flanged Bolts/Nuts/washers gasket etc all and removal of old valve of following sizes : Make - Kirloskar/Leader/BIR/Pryag |
63 | (a) 80mm bore |
64 | (b) 100mm dia bore |
65 | ( c)150 mm dia bore |
66 | Material and labour for valve pit chamber on existing chamber foundation with 230mm thick brick wall in CM 1:6, 75mm thick coping in PCC 1:2:4 (Type B1), 15mm thick plaster in CM 1:4 over all internal and external wall surface, 25x25x4mm thick MS Angle iron frame and 3.0 mm thick MSplate cover with hinges and necessary locking arrangements painting with two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed including dismantling and removal of existing damaged chamber except PCC foundation of internal size :- |
67 | (a) 600 x 600 x 600mm |
68 | (b) 900 x 900 x 750mm |
69 | (c) 1000 x1000 x 750mm |
70 | Supply and Fixing15 mm ball floatvalve high pressure of PTMT with expoxy coated alumimium rod and highdensity ball screwed for iron pipe with polythene float and fly nut completewith all accessariess including taking down the old float valve complete all as directed by Engr-in-charge |
71 | All as per item No 60 but 20mm Float valve |
72 | All as per item No 60but 25 mm Float valve |
73 | Material and labour for run lead joint including removal of old joints/joining material, excavation and earth work if any required, etc for cast iron pipe of size including taking out old run lead joint. complete all as specified and directed by Engr-in-charge (Note: Earth work shall be measured and paid sepratelly) |
74 | (a) 80mm dia bore |
75 | (b) 100mm dia bore |
76 | (c) 150mm dia bore |
77 | Material and labour for rubber flanged joint including removal of old joints/joining material, and replacing Nuts and bolts , etc for GI/cast iron pipe of following sizescomplete all as specified and directed by Engr-in-charge including taking out old joint. |
78 | (a) 80mm dia bore |
79 | (b) 100mm dia bore |
80 | Supply and fixing of superior quality suitable gland Packing rope of 8/10/12/12.5/14/16 mm sizes to Sluice Valves of different sizes and capacities including new nuts and bolts complete all as specified and directed.Note:(a) Quoted rate demmed to be inclusive of cost of rope and opening & refixing gland plate of valve/pump,.new nut botls ,packing rubber etc. |
81 | Material and labour for Cleaning of sewage well/tank of any size 07 Nos by(i) Dewatering with submercible / sludge pump to empty the sump/tank upto base level. (ii) Removing sludge from sump wall and bottom with the help of special sludge pump and remaining dirt which may have hidden in rough slots of the bottom mannualy with brush.(iii) After cleaning the sump apply bleaching powder for disinsfection of sump including painting of iron grills of the chabmer cover with black paint all as directed by Engineer-in-Charge: Note Sewage will be collected in sewage vehicle and thrown at sewage disposal area . |
82 | Supply & pouring Bio media (Floating type)made of plastic and Corrugated shapehaving Effective surface area 400Sqm/cum ,PP22 in MBBR as direct by Engineer-in-Charge |
83 | Supply & MixingSodium hypochlorite solution in liquid form for treated STP Water tank complete all as specified and directed by Eng-in-charge. |
84 | M&Lforcleaning and sterilization of insideof Overhead tankby using approved chemical as recommended to use by the Govt and ultra voilet rayincluding arrangement of necessary tools & plants, labouretccomplete all as specified and as directed for following capacitities of overhead tank: stages for cleaningare as under:- (a) Mechanised dewatering of water storage tanks (b) Removal of Sludge lying on the bottom of tank. (c) Cleaning of Internal walls of tank through High pressure Rotary jets. (e) Spray Potassium permanganate Inside the tanks as anti- bacterial agent. (f)UV Radiation in the tank for future cleaning germs. |
85 | (a) 30,000 Gallons (at Gomantak PH/MO Goa) |
86 | (b) 20,000 Gallons (at Gomantak PH/2 W Det PH) |
87 | (c) 10,000 Gallons (at NAD) |
88 | M&Lforcleaning and sterilization of insideof Under groung sumpby using approved chemical as recommended to use by the Govt and ultra voilet rayincluding arrangement of necessary tools & plants, labouretccomplete all as specified and as directed for following capacitities of under groung sump :- stages for cleaningare as under:- (a) Mechanised dewatering of water storage tanks (b) Removal of Sludge lying on the bottom of tank. (c) Cleaning of Internal walls of tank through High pressure Rotary jets. (e) Spray Potassium permanganate Inside the tanks as anti- bacterial agent. (f)UV Radiation in the tank for future cleaning germs. |
89 | (a) 20,000 Gallons (at Gomantak PH/2 W Det PH) |
90 | (b) 15,000 Gallons (MO Goa PH) |
91 | (c) 10,000 Gallons (JVT PH/DSC PH GMK/NIH PH/NAD PH/NCB) |
92 | M & L for conducting bacteriological and chemical analysis at DIRECTOR OF HEALTH SERVICES ENVIROMENTAL AND POLLUTION CONTROL WING. PANAJI, GOANOTE ;-(a) The water sample should be carried out in sterilized bottle/water can which will be issued by DIRECTOR OF HEALTH SERVICES ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI, GOA.(b) The rate quoted shall be deemed to include transportation cost & cost of sterilized bottle. (Location: Gomantak/NCB/2W Det/MO Goa/NAD |
93 | M & L for carrying out following parameters test at NABL accredited lab complete all as specified and directed. The parameter are as follows: (a) BOD (b) COD (c) Oil and grease (d) Suspended solids (TSS) (e) pH (f) DO (g) E coli Note:The rate quoted shall be deemed to include transportation cost & cost of items reqd for collection . |
94 | Supply only chloroscope meter for water testing range of 0.1 PPM to 2.0 PPM . Make:- M/S Water chem/Good Men/Magic India/ZeroB/Aquasol |
95 | Supply only O-TOLODINE reagentsolution in 500 MLbottles of superior quality duly sealed all as directed. Make:-M/s Glaxo/SOS/Water chem/Qualigens |
96 | Supply and fix Gun metal brass foot valve screwed or flanged type complete suitable for the following size of GI tubing including taking down of existing valve.Make : Leader, Bajaj |
97 | (a) 50mm dia bore pipe |
98 | (b) 80mm dia bore pipe |
99 | (c) 100 mm dia bore pipe |
100 | (d) 150 mm dia bore pipe |
101 | Supply & fix long length Cast Iron detachable jointcomplete with nuts , bolts ,washers and superier Quailty of Rubber ring set suitable for following sizes . |
102 | a) 150mm diabore |
103 | b) 100mm diabore |
104 | c)80mm dia bore |
105 | Supply of Calcium Based Granular Disinfectant For Water Treatment, More Stable Than Chlorine Gas And Stronger Than Bleaching Powder And Sodium Hypochlorite.Concentartion of Chlorine 60 To 70 Percent Stabilty Of One Year With Minimum Loss Of Chlorine in factory sealed non returnable HDPE containers (40 to 50 Kg each) complete all as specified and as directed. |
106 | Supply and fix in repairs non return valve complete all as directed of following sizes:- |
107 | (a) 100 mm dia |
108 | (a) 80 mm dia |
109 | (c)50mm dia |
110 | Supply and fixing automatic air release valve of gun metal of 20mm dia complete all as directed.Note: Rate deemed to be inclusive of drilling boreand other necessary minor items reqd for fixing of Air release valve. |
111 | M & L for emptying the sewage tank (during taking up & during lowering ) ,dismantling and disconnecting ofall electrical connections of non cloge submersible pump of any capacity, taking out from sewage well shifting it to work shop for repairing/rewinding and reassembling ,transporting back to site after repair , lowering it to sewage well , testing and commissioningcomplete all as specifiecd and directed by EIC. .Note (i) Sewage tank will be emptied by sewage vehicle and sewage will be disposed at sewage disposal site and rate is inclusive of that. (ii) All spare parts reqd for repair and rewinding will be measured and paid for seapartely under respective item of schedule. |
112 | Material and labour for, Dismantaling/openingthe burnt motor, (Rotor & stator ) rewinding the motor with super enamelled copper winding as per existinggauge including insulation material cotton tape, varnish, insulation paper, sleeves and dry and baking etc including replacing of bearing,oilingand reassembling complete motor complete all as directedNote : (i) Oil seal,impeller will be measured and paid for separately (ii) The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation (for STP motor/Centrifugal motor) |
113 | Supply only Oil seal for non clog submersible pump upto 5HP cap. |
114 | Supply only impeller for non clog submersible pump upto 5HP cap. |
115 | M&L for disconnecting the suction and delivery pipe lines, electric and waterconnections of centrifugal motor pump set of capacity and removing it from its position carefully (from sump /floor) and transporting the same to the workshop for carryout necessary repairs and refixing the same in its original position and re-connecting up of water and electric connections including testing and commissioning complete all as specified and directed. Notes:- (i)Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportation from site to the work shop and back are deemed to be included in unit rate quoted. (ii) Labour element is deemed to be included in unit rate quoted |
116 | M & L for lifting of Submersible pump alongwith pipe and connected items of any capacity from borewell upto depth of15mtr for rewinding/repairing and lowering after repair work and connectingtesting complete all as specified and directed. |
117 | M & L for lifting of Submersible pump incl pipe and connected items of any capacity from deepwell upto depth 150 mtrsfor rewinding/repairing and lowering after repair work connecting ,testingcomplete all as specified and directed. |
118 | M&L for rewinding ofthesubmersible motor with PVC insulated copper conductor winding wire of‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including replacing of bushes/bearing,oil seal,impeller ,shaft ,Gland plate ,Coupler ,oilingand reassembling complete motor for submersible motor upto 30HP complete all as directedNote : (i) bushes,bearing ,impeller,shaft,seal,gland plate,coupler will be measured and paid for separately (ii) Cost of minor spares such as nuts bolts washers etc is deemded to be inclusive in the rate quoted (iii) The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation. |
119 | Supply only impeller for Submersible pump/Centrifugal pump up to 5 HP |
120 | Supply only impeller for Submersible pump/Centrifugal pump above 5 HP upto 10 HP |
121 | Supply only impeller for Submersible pump/Centrifugal pump above 10 HP upto 20 HP |
122 | Supply only Pump shaft for Submersible/Centrifugal pumps. |
123 | Supply only Bush for Motor. |
124 | Supply only NRV for suitable for deepwell submersible pump upto 20 HP Capacity. |
125 | Supply only Star Rubber bush for Pumps. |
126 | Supply only Pump gland plate . |
127 | Supply only Pump motor Coupler. |
128 | Supply and fix ball bearing suitable for up 7.5HPcapacity motors/pumps after removal of old unserviceable bearing and making proper alignment and testing all as specified and directed by Engr-in-Charge Make: SKF/NCB/FAG/NRB/TATA |
129 | Supply and fix Solenoid valve senser of on line booster pump of 1 HP pumpincluding taking down of existingcomplete.Make: As per existing |
130 | Supply and fix flat submersible copper conductor cable 1100 volts grade PVC insulated flexible, PVC sheathed with multistranded copper conductorcutting to required length connecting with necessary end ferrules / water proof joints of following size including removing the existing unserviceable cable complete all as specified and directed of follwing size:- Make :-Finolex/plaza/Havells/Finecab |
131 | (a) 3 Core 4 Sqmm |
132 | (b) 3 Core 6 Sqmm |
133 | Supply and fixingAutomatic Star delta starter with contactor and pnematic timer ,relay range 23-32 Amp ,contactor rating 25 Amps, 3 ph ,415 V, 50 Hz complete all as directed including taking down old .Make BCH India/Havells |
134 | Supply and fixing repairs Automatic Star delta starter with contactor and pnematic timer ,relay range 13-20 Amp ,contactor rating 16 Amps, 3 ph ,415 V, 50 Hz complete all as directed including taking down old .Make BCH India/Havells |
135 | Supply and fix in repairs flange for Pipes including threading ,welding etcof follwing Sizes:- |
136 | (a) 80 mm dia size |
137 | (b) 100 mm diz size |
138 | Supply and fixingDOL Starter suitable for 2 to 5 HP Motor ,415V,3 phase ,50Hz ,contactor rating 16 Amp complete all as directed .Make BCH India/Havells |
139 | Supply , Install & testing of Starter panelfloor mounted type made of modular polycarbonate thermoplastic enclosures of size 800 X 985 X 600 mm ,IP 65 Protection ,415V,50Hz,4 wire+ Earth complete all as speicified.The panel should have bottom cable entry with MS legs of not less than 60cm height including necessary earth/PCC work . The manufacture shall submit a copy ofTEST REPORT of board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1 including provision of cable entry and exit hole. The Starter panel shall include the following:- Incoming :- (i) MCB 40A ,FP ,10KA -01 No Outgoing:- (i) MPCB 20A ,TP- 02 Nos (ii) Contactor 25A TP- 02 Nos (iii) Contactor 7A TP- 02 Nos (iv) Over load realy-02 Nos (v) Satr Delta Timer-02 Nos (vi) ON/OFF/Trip indicating lamp-02 Nos Each (vii) Start/Stop push button-2 Nos Each (viii) Auto/off/Manual selector swicth-02 Nos Each (ix) Fuse terminal block with fuse -008 Nos (x) Analog ammeter--02 Nos (xi) CT 20/5A CL1 5VA-02 Nos (xii) Analog voltmeter- 02 Nos (xiii) Voltmeter Selector switch -02 Nos (xiv) Star delta starter 10HP -02 Nos mounted on RAL7016 mounting structure with Base angle 60cm -02 Nos and leg height not less than 30cm.Make - Hensel / Schneider./Sintex/National |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy