| 1 | Surface excavation notexc 30 cm deep and average 15 cm deep and getting out in any type of soil complete all as specified and as directed. |
| 2 | Excavating over areas, notexc 1.5 mtr deep and getting out in hard / dense soil complete all as specified and as directed. |
| 3 | Excavation intrenches not exc 1.5 mtr wide and not exc 1.5 mtrin depth and getting out any type of soil for Parapet walls etc complete all as specified and as directed.. |
| 4 | Removing excavated material exc. 1.50km but not exc. 5.0 km and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and as directed. |
| 5 | Removingexcavation material not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 6 | Rolling and consolidating formation surfaces in cutting with power roller of capacity exc 8 tonneandnot exc 12 tonne power roller complete all as specified andas directed. |
| 7 | M&L for solling (or sub base) 200 mm spread thickness with broken boulders or quarriedstone, interstices filled ,surfaces formed and rolled and consolidated to required gradient and camber complete all as specified andas directed. |
| 8 | M&L for Water Bound Macadam (WBM) 150 mm thick (compacted thickness) in two layers of 75 mm thick each layer , with coarse granite aggregates of grading 2 (63 mmto 40 mm size) each layer spread separately, rolled and consolidated to required gradient and camber etc., using power roller exceeding 8 tonne and not exceeding 12 tonne capacity power roller complete all as specified and as directed. |
| 9 | M&L for preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mudetc, sweeping with mechanical blower or brooms and finally fanning the cleared surface with gunny bags to remove all loose dirt etc complete all as specified andas directed. |
| 10 | M & L for applying evenly a priming / tack coat with bituminous primer (paving bitumen (RS-1) Rapid Setting @ 5.0 Kg / 10 Sqm complere all as specified and as directed . |
| 11 | M&L for Applying evenly a primary / tack coat with bitumen emulsion at 4.0 Kg/ 10 Sqm complete all as specified and as directed. |
| 12 | M&L for soling (or GSB Granular Sub Base) 300 mm spread thickness with broken boulders or quarried stone Interstices filled, surface formed and rolled and consolidated to required gradient and camber of spread thickness 300 mm complete all as specified and as directed. |
| 13 | M&L for Preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags etcto remove all loose dirt etc complete all as specified and as directed. |
| 14 | M & L for applying evenly a priming/tack coat with bituminous primer (Paving Bitumen (RS-1) Rapid Setting @ 2.5 kg /10 Sqm complere all as specified and as directed . |
| 15 | M&L for Bituminous Premix Semi Dense AsphalticConcrete (SDAC) (using VG-30 grade bitumen)40 mm consolidated thicknesh with 5.5% of binder content by weight of tatal mix, rolled and compacted to required camber and gradient complete all as specified and as directed. |
| 16 | M&L for preparing bituminous surfaces of roads and marking 2.50 mm thick centre lines , stop lines , dashes , arrows etc and the like not exc 10 cm wide on roads , pavements with hot applied thermo plastic road marking paint of approved colour conforming to BS- 3262-1989 with special applicator machine all as per manufacturers instructions complete all as specified and as directed. |
| 17 | S & F metal tubular dealineatore made out of ABS round body fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PMMA and mounted on 45 / 50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green , red and yellow reflector radium type of 25 mm wide strips with anti theft steel net for reflector protection including embedded in cement concrete PCC 1:2:4 type B-1 mix using 20 mm graded stone aggregate (150 mm x 150 mm x 300 mm size) complete all as specified and as directed. MAKE :- Bons Light PVT Ltd, Ahmedabad/ TATA BP Solar /3M / Asian Controlls , Mumbai / SA Traffic Safety , Kolkata |
| 18 | M&L for continuous brick edging with sub class \"B\" bricksold size with width equal to the width of the brick ; laid dry on end vertically complete all as specified and as directed. |
| 19 | M&L for cement concrete PCC 1:5:10 type E-2 mix(using 40 mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed. |
| 20 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan exc 6.0 mtr mean radius built in CM1:6 complete all as specified and as directed. |
| 21 | M&L for rendering 15 mm thick cementin CM 1:4on fair surfaces of brick work or concrete surfacesand rendering is to befinishedeven and smoothwithout using extra cement complete all as specified and as directed. |
| 22 | M&L for Precast cement concrete 1:2:4 type B-1 mix (using 20 mm graded stone aggregate) asin kerb stoneset in cement mortar 1:4 complete all as specified and as directed. |
| 23 | M&L for Preparing new plastered surfaces of walls andapplying three coats of white wash complete all as specified and as directed. |