Construction Of Chemistry, Biology Lab And Boys And Girls Toilet At Gic Charba. Construction Of Chemistry, Biology Lab And Boys And Girls Toilet At Gic Charba.
Tender Value
42.55 Lakhs
Estimated cost
Bid Submission
05 Dec 2021
0 days left
EMD
86000
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sahaspur → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Chemistry, Biology Lab And Boys And Girls Toilet At Gic Charba. Construction Of Chemistry, Biology Lab And Boys And Girls Toilet At Gic Charba.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic Excavat in foundation trenches or drains (not exceeding 1.5 m in width or 1 including dressing of sides and ramming of bottoms, lift upto 1.5out the excavated soil and disposal of surplus excavated soil as dir of 50 m. All kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - -All work upto plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
| 3 | Filling available excavatedearth (excluding rock)in trenches, plin sidesoffoundationsetc.inlayersnotexceeding20cminde consolidatingeachdepositedlayerbyramming andwatering, up to 50 m and lift upto 1.5 m. |
| 4 | SupplyingandfillinginplinthwithJamunasandunderfloorsincluding, watering, ramming consolidating and dressing complete. |
| 5 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. |
| 6 | Brick work with F.P.S. bricks of class designation 75 in foundationand plinth in Cement mortar 1:6 ( 1 cement : 6 coarse sand ) |
| 7 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shape and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | Half brick masonry with F.P.S. bricks of class designation 75 insuperstructure above plinth level upto floor V level inCement mortar 1:4 (1 cement : 4 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a |
| 9 | Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centring, shuttering,finishing and reinforcement - All work upto plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers,abutments, posts and struts etc. uptofloor five level excluding cost of centring, shuttering, finishing and reinforcement in1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 12 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete - TMT |
| 13 | Centring and shuttering including strutting,ropping etc. andremoval of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 14 | Centring and shuttering including strutting,ropping etc. andremoval of form for Suspendedfloors,roofs,landings,balconiesandaccess platform. |
| 15 | Centring and shuttering including strutting,ropping etc. andremoval of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 16 | Centring and shuttering including strutting,ropping etc. andremoval of form for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 17 | Providing and fixing pressed steel door frames confirming to IS: 43 from commercial mild steel sheet of 1.25 mm thickness including h jamb, bead and if required angle threshold of mild steel angle of se or base ties of 1.25mm pressed mild steel welded or rigidly fixed t mechanical means, adjustable lugs with split end tail to each jambbutt hinges 2.5mm thick with mortar guards, lock strike-plate andas specified and applying a coat of approved steel primer after pre surface as directed by Engineer-in-charge. Profile B |
| 18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete - Fixed to steel windows by welding |
| 19 | ProvidingandfixingM.S.Tubularframesfordoors,windows,ventilatorsandcupboardwithL-Typesectionmadeof1.60m M.S.Sheet,jointsmitredandweldedandgrindedfinishprofi requiredsizewith15x3mmlugs10cmlongembeddedince concreteblocks15x10x10cmof1:3:6(1cement:3coarse graded stone aggregate 20mm nominal size) or with wooden plugsscrewsorrawlplugs andscrewsorwith fixing clipsorwith b nuts asrequired including fixingofnecessarybutthinges and and applying a priming coat of approved steel primers. |
| 20 | 12 mm cement plaster of mix.1:6 (1 cement : 6 fine sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item |
| 21 | 6 mm cement plaster of mix. 1:3 (1 cement: 3 fine sand) |
| 22 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 23 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter |
| 24 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement theentire treated surface will be measured. |
| 25 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 26 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade |
| 27 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 28 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement m |
| 29 | Providing and laying matt finished vitrified tile of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 30 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 31 | Makingplinthprotection50mmthickofcementconcrete1:3: cement:3coarsesand:6gradedstoneaggregate20mmno size)over75mmbedbydrybrickballast40mmnominalsiz rammedandconsolidatedandgroutedwithfinesandincludin finishing the top smooth. |
| 32 | Brickedging7cmwide11.4cm.deeptoplinthprotectionwit bricksofclassdesignation75includinggroutingwithcementmortar 1:4 (1 cement : 4 fine sand) |
| 33 | Providing and fixing ISI marked flush door shutters conforming to I non-decorative type, core of block board construction with frame o wood and well matched commercial 3 ply veneering with vertical g bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 34 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic) 300x16 mm |
| 35 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not) 125 mm |
| 36 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating ) 250x10 mm |
| 37 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 38 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade |
| 39 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications. Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 40 | PaintingwoodworkwithDeluxeMultiSurfacePaintofrequired shade.Twoor more coat applied @0.90ltr/[email protected]/10sqm ofapproved brand or manufacture |
| 41 | PaintingSteel workwithDeluxeMultiSurface Paintto givean even shade. Two or morecoatapplied @0.90 ltr/10sqmover an under coatof [email protected]/10sqmofapproved brand or manufacture |
| 42 | Renewing glass panes, with putty and nails wherever necessary. Float glass panes of thickness 4 mm |
| 43 | windows using galvanised M.S. wire gauge with average width of a in both directions with wire of dia. 0.63 mm. With 12 mm mild steel U beading. |
| 44 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) |
| 45 | 12 mm Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on top of slab including all. |
| 46 | Lettering with black Japan paint of approved brand and manufacture |
| 47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes(75 mm diameter ) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as pe |
| 48 | Providing and fixing brass stop cock of approved quality 15 mm nominal bore as per direction ofEngineer-in-charge, work to be execuated as per specification a rate of above given |
| 49 | Making soak pit 2.5 m diameter 3.0 metre deep With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 and45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard desi |
| 50 | WhiteVitreousChinaFlatbackwashbasinsize550x400mm with single 15 mm C.P. brass pillar tap. as per direction ofEngineer-in-charge, work to be execuated as per specification a rate of above given |
| 51 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern as per direction ofEngineer-in-charge, work to be execuated as per specification a rate of above given |
| 52 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cementconcrete slab 1:2:4 mix (1 cement : 2 coarse sand |
| 53 | Providing and placing on terrace (at all floor levels) polyethylene water tank ISI : 12701 marked with cover and suitable locking arrangement in tank. and necessary holes for inlet, outlet and overflow pipes but without fitti base support for tank. |
| 54 | Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc. (external work) 15 mm dia. nominal bore |
| 55 | Providing and fixingbrassbib cock of approved quality conforming to IS standards and weighing not less than 690 gms.. |
| 56 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P.Size 600x450x200mm. |
| 57 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
AI Tender Summary
Tender Timeline
Nov 24, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedDec 05, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 07, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender