Development Of Tourism Near Break Water At Thangassery Kollam - Electrification Of Associated Building Development Of Tourism Near Break Water At Thangassery Kollam - Electrification Of Associated Building, KOLLAM THANKASSERY-Kerala

Harbour Engineering Department has published Development Of Tourism Near Break Water At Thangassery Kollam - Electrification Of Associated Building Development Of Tourism Near Break Water At Thangassery Kollam - Electrification Of Associated Building. Submission Date for this Tender is 06-12-2021. Electrification Work Tenders in KOLLAM THANKASSERY Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

30013798
Corrigendum : Development Of Tourism Near Break Water At Thangassery Kollam - Electrification Of Associated Building Development Of Tourism Near Break Water At Thangassery Kollam - Electrification Of Associated Building
Open Tender
Indian
Kerala
KOLLAM THANKASSERY
06-12-2021

Tender Details

Development Of Tourism Near Break Water At Thangassery Kollam - Electrification Of Associated Building Development Of Tourism Near Break Water At Thangassery Kollam - Electrification Of Associated Building

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Dec-2021 date extension Date 06-12-2021

Key Value

Document Fees
INR 3300 /-
EMD
INR 22300.0 /-
Tender Value
INR 14.81 Lakhs /-

BOQ Items

Work Name : Development of Tourism near Break Water at Thangassery Kollam - Electrification of associated Building
Sl. No. Item Description
1Fabricating, supplying, conveying, lifting and erecting double armtubular post of overallheight of 7musing 6m80mm and 3.0m 50mm Heavy G.I. Pipehaving ISI mark and of approved quality as per the drawing, erected on a RCC1:2:4 foundation in 4 Nos well steining of 0.3m depth and0.75 m dia.anda muffing of 0.60x0.60m with height 1.0 m.The post shall be erected on 4 numbers of 20mm dia GI foundation bolts of length 2.3m having 100mm long standard thread with a 12mm thick GI flange suitable for80mm C class pipeat the bottom of the post and 80 D flange on the muffing with 4 nos of 20mm bolt holes and 3Nos of 20mm nuts per bolt. The bottom of the post shall be provided with suitable size stiffner pieces.The post is to be painted with two coats ofbest quality industrial epoxy paintovertwo coats of industrial epoxy primer . Muffing to be plastered using cement mortar 1:4, 12mm thick colour washing 2 coats using approved colour etc. complete.All GI pipe sections to be used for the fabrication of the post shall be of TATA/ZENITH/APOLLO make.All steel items shall be dip galvanised.
2Supply of BIS approved LED Luminaire with system wattage of 35W, made up of pressure die cast Aluminium body and anti UV PC Protector with integrated lenses for increased pole spacing and uniform light distribution, IP66, IK 08, system efficacy of 110 lm/W, CCT 4000K, operating temp range up to 50 degree and designed for efficient thermal management, lumen maintenance L70@ 50000Hrs, Upward Light Output Ratio is 0% atzero degree inclination to avoid light pollution, suitable for side / vertical mounting up to 48mm diameter, Colour Rendering Index > 70, a driver efficiency > 85%, with internal surge protection of 4kV and Power factor > 0.95.Make: Keselec Cat Ref: Nice-R 35W NW LEDor equivalent
3Conveyance, installation, testing and commissioning of departmentally supplied flood light/ area lightluminaire with lamp to a heightupto 8m from ground level.
4Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
5Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire
7Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 6sq. mm + 2 X 6 sq. mm earth wire
8Supplying, fabricating , erecting and commissioningfloor mounting, fully compartmentalised, dust and vermin proof cubicle MAIN panel board of size 1250 x 1450 x 250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality synthetic enamel paint over two coats of epoxy primer, having one vertical bus bar chamber, three vertical and one horizontal cable alley having front openable bolting type cover with cable entry provisions, bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. The panel should have 75x40x6mm MS channel provided at the bottom as support and comprising the following.Incomer:-63 A, AC 23-A, 4 pole on-load Change Over Switch in open ExecutionIncoming:- 63A, 25kA FP MCCB setted to 50A and rotory drive kit includingBUChandle and shunttrip coil with auxiliary contact- 1No,Outgoings:- 40 A FP MCCB 25 KA setted to 32 A- 2Nos with rotary handle ,25 A TP MCCB 25 KA setted to 20A - 4Nos with rotary handleand 32 A two way disconnectable type neutral link suitably connected,,All switches and MCCBshould be of panel mounting,Ics=100% Icu and conforming to IS:13947partIII (L&T/SIEMENS/Legrand).Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator.Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves.Interconnections with the incoming and is also to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators and outgoing with suitable rated copper conductoras required.Protection :- ELR with CBCT , 3 Phase 4 wire Under & Overvoltage relay,reverse phase sequence relay (Auto/ manual reset ,Trip time and Power on delay1 - 10 sec) OV / UV - adjustable , Electronic on delay timer 1 - 10 sec for shunt coil - 1 No,Control contactor 2NO+2 NC,DIN Rail Surge Protection Device (4+0) Class B & Class C/ Type 1 & Class 2 Tested as per IEC 61643 Part 11:2016 . Nominal voltage -230V 50/60Hz, MCOV of 275 V , Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV & Residual Voltage @ 5 kA(8/20) <0.8 kV . The Surge Protection Devices should have TOV withstandfor 120 Min : 438 V and with out Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT& the Protection Modes for : L & N toPE . Short- Circuit Current rating (Isccr) – 25 kA/50 Hz . Back up fuse required more than 160AgG/gL. Health Status Indication required in all cartridge. Total Response time <25nano sec . Make : Raycap / Erico / Weidmuller .Metering and Indication:- Panel surface mounting 96 Sq.mm LED Multi-function meter with three line display to read V,A,,kVA,kVAr,PF,KW and frequency of make Schnider or equivalent suitable for 415V,50Hz with RS485 port- 2 Nos,60/5 A Tape wound CT 3 Nos ,and 2A SP MCB C Curve (Cat B)-6Nos and a63A two way disconnectable type neutral link inside the cubicle. The panel board should have hinged shutters for OLCOS/ MCCB cubicles and front openable bolted type busbar covers and it should be fabricated as per Kerala State Electrical Inspectorate"s norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 25x3 mm copper strip with two earthing points at bottom side. (Panel drawing attached with the schedule)
9Supplying and fixing of surface/ recess mounting, vertical type, 415 volts,Dust and waterproof ,IP66 Hensel make or equivalentFPVN 0400Transparent door( 8 + 12 way) VTPN poly carbonate distribution board , with provision for Isolator/RCCB as incomer ,125 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB"s painted, inclusive of , tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
10Supply and fixing IP 65weather proof polycarbonate 9module 200*238*111MCB distribution board with PE + N Terminals on the surface using suitable sizestainless steel screws.
11Supply and fixing IP 65Thermoplastic circuit breaker boxes3 row 36module 295 x 583 x 129 mm MCB distribution board with PE + N Terminals on the surface using suitable sizestainless steel screws.
12Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, 25A residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
13Supplying and fixing40A, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
14Providing and fixing 0.3 m ,20 mm X 3 mm copper strip on surface or in recess for connections etc. as required.
15Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
16Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle).
17Supply of 4 core 4.0 sq mm PVC insulated and PVC sheathed armoured copper Power cable
18Supply of 4 core10 sq mm PVC insulated and PVC sheathed armoured aluminum cable
19Supply of 4 core16 sq mm PVC insulated and PVC sheathed armoured aluminum cable
20Supply of 4.0 core25 sq mm PVC insulated and PVC sheathed armoured aluminum cable
21Supply of3 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
22Supply of3 core 2.5 sq mm PVC insulated and PVC sheathed submersible coppercable
23Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C x 10 sq.mm(25mm)
24Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required..4C x 16 sq.mm(28mm)
25Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required..4C x 25 sq.mm(32mm)
26Supplying and making end terminationnickel plated single compression brass cable gland for 4 core4 sq mmPVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade,including providing earth clip and superior quality copper cable socket.
27Supplying and making end terminationnickel plated single compression brass cable gland for 3 core2.5 sq mmPVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade,including providing earth clip and superior quality copper cable socket.
28Supply of 50/38mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to under ground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II,
29Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metre.
30Providing and fixing10 SWGcopper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
31Providing and fixing 6 SWGcopper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
32Supply and laying bare earthingcopper conductor 6 SWG laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in Ordinary soil).
33Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
34Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
35Supply and providing25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
36Supply of superior quality copper earth socket for the 3.15mm (10 SWG)earth conductor including crimping etc. as required.
37Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
38Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
39Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
40Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
41Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
42Supplying and fixing single pole blanking plate in the existing
43Supply and fixinghenselmake PolycarbonateCable Junction Boxes IP66/69 weather proof for outdoor installation (with plain knockouts for cable entry155*210*92KF 1616 Bor equivalentand accessories for Cable Junction Boxes such as Copper Terminal Set4.0 sq.mm 5 Pole 1 No,Support for Terminal1No , DIN rail for fixing MCBincluding fixing the accessories using suitable size Stainless steel Bolt and nut,giving necessary connections, making good the damages etc. as required.
44Supply andinstallationofwall mountingcubicle type dust and vermin proof 600x300x214 mm, Hensel make hinged door polycarbonateEnclosure - IP65 outdoor enclosurewith provision for fixingKSEB meter, cut out & Neutral linkwith sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link. Supply and providing3Nos of 63A HRC fuse units with 40A HRC fuse link and 1No 63A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wireThe inter connection should be done using16.0sq.mm copper wire.
45Supply andinstallationofwall mountingcubicle type dust and vermin proof CAPE make CA43a ,360x270x205mmIP66,IK 10 Glass fibre reinforced polyester enclosure with base plate including supply and fixing 40A , 25kA FPMCCB, with rotary handle, 3 Nos phase indication lamp and 3 Nos 2A SP MCB including wiring using 2.5 sq.mm wire for control wiring .
46Supply andinstallationofwall mountingcubicle type Hensel make Mi 9300 or equivalent thermoplastic polycarbonate energy meter enclosure with hinged lid450 x 300 x 170 mm , IP65 withbase plate and sufficient holesfor fixingKSEB meter, cut out & Neutral link and fixing 20A , 10kA SPN MCB, C curve .
47Supply and providing1 No32A HRC fuse units with 20A HRC fuse link and 1No 32A 2way neutral link in theexisting enclousure and giving necessaryinter connection using4sq.mm copper wire and holes are to be provided inthe box for entry and exit of wire.
48Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
49Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
50Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
51Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
52Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
53Providing and fixing B class G.I. pipes with ISI markcomplete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 50 mm dia nominal bore
54Wiring for light point / fan point/ exhaust fan/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required(Group C)
55Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
56Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
57Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4.0 sq. mm
58Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 X 6 sq. mm
59Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
60Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
61Supplying and fixing following size / modules, Plasticboxesalongwith modular base & cover plate for modular switches on surface or inrecess etc as required. 1 or 2 Moduleplastic box
62Supplying and fixing following size / modules, Plasticboxesalongwith modular base & cover plate for modular switches on surface or inrecess etc as required.3 Moduleplastic box
63Supplying and fixing following size / modules, Plasticboxesalongwith modular base & cover plate for modular switches on surface or inrecess etc as required. 6 Moduleplastic box
64Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75mm)
65Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
66Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
67Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6amp switch
68Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
69Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
70Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ 11 Telephone jack
71Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. CAT 6 RJ 45 computer jack .
72Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ 45frame
73Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
74Supplying suspended LED luminaire Philips SM 270 C LED 30S - 6500 PSU WHor equivalent
75Supplying Philips or equivalentbattenLED tube600mm 10W etc complete.
76SupplyingLED luminaire Philips WT 201 CLED 20S - 6500 PSUL 120 IP 65 or equivalent
77Supplying 20 W LED Tube with box typefixtures EssentialLED tube1200 mm20W 865 T8APIPhilips or equivalent
78Supply and fixing 7/9WLED lamp OSRAM / Philips or equivalent
79Supplying Keselec Schreder make Street light luminaire 20W LED, an IP66 optical & control gear compartment, a die cast aluminium painted housing, Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 90 Lumen/Wat Ta 25°C. Lifetime residual flux @ Tq 35°C @ 50,000 hours = 70%, Ta = 50°C, in built surge protection of 4kV (in Differential and Common mode), Power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700°K).
80Supply and fixingbrass batten / angle holder including connection etc as required
81Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for LED Lamps including connection etc as required.
82Supply of ceiling fans of 1200 mm sweepCategory B Ceiling fan Crompton highspeed or equivalent excluding resistance type regulator
83Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
84Supplying and fixing call bell / buzzer suitable for single phase, 230 volts, complete as required.
85Supplying and fixing metal box of 150 mm X 150 mm X 60 mm deep size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
86Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
87Supplying and fixing extra conduit down rod of 1m length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
88Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
89Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
90Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existingpipe/ pole including giving connections with the existing wiring etc as required
91Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shapeand fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings). 40 mm dia with clamps made from 20 x 3 mm MS flat
92Supply of single phase , 230V ,90W,1400 rpm, 305 mm sweepheavyduty exhaust fan ( Almonard or equivalent) in metal frameCategory B ,
93Supplying metal shutters suitable for 305 mm sweep heavy duty exhaust fan
94Installation of exhaust fan upto 450 mm sweepin the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
95Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
96Supplying and drawing UTP four pair CAT 6 LAN cable in the existing surface/recess steel/ PVC conduit. One run of cable
97Supplying and drawing2 pair 0.5 sq mm FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
98Supply ofCat 6,2 metre patch cord
99Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
100Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200 mm X 250 mm X 60 mm deep
101Supply and fixing 230V ,7A, singlepole contactor AC-3 duty with 1NO+1NC contactorfor 1 HP motor
102Supply and fixing KSEB approved makesingle phase kWh meter 5 - 30A accuracy class 1 base mountable with LCD display.
103Supply and fixing panel surface mounting 96mm square 3 lineLED type Multifuntion meter with V,Iand frequency measurement(vif)socomec or equivalent suitable for 230 ac 50Hz
104Supply and providing 12 mm thick & 1 m wideelectrical grade chequered type rubber mat to withstand 15 KV dielectric strength conforming to IS 5429 / 1969.
105Supply and providing 6Kg stored pressure ABCPowder type Fire Extinguisher with hose , pressure gauge and clamps including fixing it to wall as required.
106Supplying IP66, IK 10 rated 100W NW flood light luminaire with body of aluminium extrusion having luminaire efficacy >= 120lumen/watt supplied with IP67 rated best in class LED driver. Preffered make:Keselec-K Flood 100W- NW
107Supply and providing single line diagram duly framed,laminatedand placed in a conspicuous location for clear vision
108Supply, fabrication, conveyance and fixing 50 mm dia heavy dutyC classwith clamps made from 20 x 3 mm MS flatbent to shapeand fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
109Supply and fixing SP MPCB Suitable for 1H.P DOL with suitablethermal release range