}

Special Repair To Replace Apfc Panel And Connected Works At Af Stn Singarsi Under Age I Af Singarsi, AGE I AF SINGARSI-Himachal Pradesh

Military Engineer Services-MES has published Special Repair To Replace Apfc Panel And Connected Works At Af Stn Singarsi Under Age I Af Singarsi. Submission Date for this Tender is 06-12-2021. Power Factor Panel Tenders in AGE I AF SINGARSI Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30002059
Corrigendum : Special Repair To Replace Apfc Panel And Connected Works At Af Stn Singarsi Under Age I Af Singarsi
Open Tender
Indian
Himachal Pradesh
AGE I AF SINGARSI
06-12-2021

Tender Details

Special Repair To Replace Apfc Panel And Connected Works At Af Stn Singarsi Under Age I Af Singarsi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Nov-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 18600.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : SPECIAL REPAIR TO REPLACE APFC PANEL AND CONNECTED WORKS AT AF STN SINGARSI UNDER AGE(I) AF SINGARSI
Sl. No. Item Description
1Repairs/ maintenance of APFC panel of any make up to capacity 125 KVAR by rewiring of circuit of APFC panel and making functional complete including calibration of relay, digital meter, cleaning with air blower ,replacement of any nonfunctional part such as power factor controlerrelay, multifunction meter, capacitors, capacitor duty contractor,MCB, MCCB, cooling fan, wiring etc. all as specified and directed by engineer in charge and testing complete. Note : 1.Unserviceable Spare Part will be paid and measured separately under respective items of Schedule ‘A’ as supply only. 2. Accessories such as fuse ,Neutral link shall be deemed to be included in quoted rates.
2Supply onlycylindrical type capacitor 440V (AC) 3 phase, 50 Hz to complete all as specified and directed by engineer in charge KVAR rating of 1 KVARof make Havells/ HPL/ L&T//C&S/ABB/EPCOS or Equivalent.
3All as above but 2 KVAR of make Havells/ HPL/ L&T/ HAVELLS/C&S/ABB/EPCOS.
4All as above but 5 KVARof make Havells/ HPL/ L&T/ HAVELLS/C&S/ABB/EPCOS.
5All as above but 10 KVARof make Havells/ HPL/ L&T/ HAVELLS/C&S/ABB/EPCOSE.
6All as above but 20 KVARof make Havells/ HPL/ L&T/ HAVELLS/C&S/ABB/EPCOSE.
7Supply only relay (controller 3CT ) 8 steps suitable forAPFC panel(Make : Havells model no QHOTBS5H0008 series 12 step relay) or equivalent of make epcos/ HPL/ L&T/C&S/ABB.
8Supply only relay (controller 3CT) 12 steps suitable forAPFC panel(Make : Havells model no QHOTBS5H0012 series 12 step relay 230 V) or equivalent EPCOS/ HPL/ L&T/C&S/ABB.
9Supply only POWER contactor for capacitor switching 3 pole AC operated for APFC panel 9A make- L&T C&S/ABB/HAVELLS.
10Supply only 5kVar CAPACITOR DUTY contactor for capacitor switching 3 pole AC operated for APFC panel make: L&TC&S/ABB/Havells.
11Supply only 10kVar CAPACITOR DUTY contactor for capacitor switching 3 pole AC operated for APFC panelmake- L&TC&S/ABB/Havells.
12Supply only 20kVar CAPACITOR DUTY contactor for capacitor switching 3 pole AC operated for APFC panel make- L&TC&S/ABB/Havells.
13Supply only MCB TP 16 amp 10KA,C curve.
14supply only MCB TP 25 to63 amp 10 KA .
15supply only MCB SP 6 Amp 10 KA C curve.
16Supply only single core 4 sqmmPVC insulated FRLSHstranded copper cable.
17Supply only single core 6 sqmmPVC insulated FRLSHstranded copper cable.
18Supply only in repair Red/Yellow/Blue LED indicating lamp (Set of three lamp), 240 volts, AC supply.
19Supply only in repair cooling fan of APFC panel of suitable size as per site requirement with complete connection all as specified and directed by Engr in Charge.
20Supply, installation, testing and commisioning of Current transformer (CT) ring type with ratio50/5 to150/5Amp 5 VA suitable for relay of APFC panel complete all as specified and directed by engineer in charge make- alpha/EESMA/AE
21Supply only digital multifunction meter for measuremnt of ,V, A, F, PF, kW, kVA, Old energy, Load hours, site selectable kWh/ kvah L&T cat:WL440010OOOO
22Supply only MCCB 4 Pole,415 V, 160 Amp.,andbreaking capacity of 25 KA make- cat part CM90634 series of L&T or equivalent in legrand/schneider/havells
23Supply only MCCB 4 Pole,415 V, 320 Amp.,andbreaking capacity of 50KAAdjustable type make- cat partCM9804OOQO DU400N series of L&T or equivalent in legrand/schneider/havells.
24M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8m below normal ground level connected to and including galvanised iron or steel earth strip 25x4 mmby means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point.Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive ofexcavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified& directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labourfor connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
25Excavation in trenches not exceeding 1.5 meter wide and n. exc 1.5 meter deep in soft/loose soil for laying of pipe lines/ cables and getting out complete all as specified and directed.
26Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25 cm thick after laying and testing of pipes complete all as specified and directed.
27Removingexcavated material to a distance not exceeding 50 meter and depositing where directed at level not exceeding 1.5 meter above the starting point complete all as specified anddirected.
28M & L Sand cushioning to PVC under ground cable with screened and washed sandincluding punning gently (up to 23 cm depth ,8 cm below the cable and 15cm above the cable) all as specified and directed. Note: - Thickness after punning will be measured for payment
29M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) laid flat abutting each other with width of protection being equal to length of brick. The gap between adajcent bricks shall not exceed 10 mm as directed by Engineer-in-Charge.
30Supply and LayingCable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured,cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on wallsof50 Sqmm 3½ Core size. (Note 1.: Earth work, excavation shall be measured & paid separately under respective item of Schedule). make- Havells/Gloster/Polycab
31All as above but 70 Sqmm,3½ core cable.
32Painting of APFC Panel complete all four sides with synthetic enamel paint after preparing the surface all as directed by Engr-in- charge.
33Supply, installation, Testing commissioning of Automatic power factor improvement capacitor Bank having aggregate capacity : 90 KVARin 8 stages with micro processor along with factory made Outdoor type panel weather proof, vermin proof, fully ventilated both side opening andfabricated outofCRCA Sheet 3.15 MM thickhavingbus bar of Aluminum 200 Amps cap, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeve &housed inspecifiedcompartmentbothsideopen able . All the cover shall have withsuitable lockingarrangements , fully internally wired with suitablesizeof thimbles. Incoming / outgoinginternalconnectionwithPVCinsulatedPVCsheathed multistranded copper wire of suitable size all as directed & comprising the following :- Make:- Havells/ Schneider / ABB/ L&T/Universal Switch Gear Control/ Tricolite. BUS BAR CHAMBER :- (a) 200 Amp 3 Strips & Neutral Strip 100 Amp, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter- 01 Set, (ii) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three), (iii) Protection MCB 6 A SP C Series- 1 Set. (Set of three), Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 160 Amps 25 KA , 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 No, (ii) Capacitor Duty Contactor suitable for 1 X 25 + 2 X 20 + 1 X 10 + 1 X 5 KVAR Capacity, (iii) Power Contactor 9 A 3 Pole for 2 , 1 KVAR = 3 Nos, (iv) Contactor shall be protected with MCB TP 10 KA (v) MCB 63 A 10 KA TP for 25, 20 KVAR = 3 Nos, (vi) MCB 25 A 10 KA TP for 10 KVAR = 1 No., (vii) MCB 16 A 10 KA TP for 05, 2, 1 KVAR = 4 Nos, (viii) Power Capacitor 1 X 25 + 2 X 20 + 1 X 10 + 1 X 5 + 2 x 2 +1 KVAR, (ix) Power Capacitor 5 KVAR with MCB 16 A 10 KA TP Fixed with Bus Bar - 1 No, (x) APFC Relay 8 Stage - 1 No, (xi) Indicating Red Light = 8 Nos, (xii) Auto manual selector switch = 8 Nos. Make of MCCB/MCB:- L&T/ HPL. Note:- The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 ( IS/IEC: 61439-1 ), 2011 & IS/IEC: 61439-2 ), 2011 ) 2. CPRI Short Circuit withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED
34Supply, installation, Testing commissioning of Automatic power factor improvement capacitor Bank having aggregate capacity : 110 KVARin 10 stages with micro processor along with factory made Outdoor type panel weather proof, vermin proof, fully ventilated both side opening andfabricated outofCRCA Sheet 3.15 MM thickhavingbus bar of Aluminum 200 Amps cap, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeve &housed inspecifiedcompartmentbothsideopen able . All the cover shall have withsuitable lockingarrangements , fully internally wired with suitablesizeof thimbles. Incoming / outgoinginternalconnectionwithPVCinsulatedPVCsheathed multistranded copper wire of suitable size all as directed & comprising the following :-Make:- Havells/ Schneider / ABB/ L&T/Universal Switch Gear Control/ Tricolite. BUS BAR CHAMBER :- (a) 200 Amp 3 Strips & Neutral Strip 100 Amp, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter- 01 Set,(ii) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three), (iii) Protection MCB 6 A SP C Series- 1 Set. (Set of three), Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 160 Amps 25 KA , 4 Pole with Adjustable thermal & magnetic release 415 volts , 50Hz,=01 No,(ii) Capacitor Duty Contactor suitable for 1 X 25 + 2 X 20 + 2 X 10 + 2 X 5 KVAR Capacity, (iii) Power Contactor 9 A 3 Pole for 2 , 1 KVAR = 3 Nos,(iv) Contactor shall be protected with MCB TP 10 KA,(v) MCB 63 A 10 KA TP for 25 KVAR or 20 KVAR = 3 Nos,(vi) MCB 25 A 10 KA TP for 10 KVAR = 2 Nos, (vii) MCB 16 A 10 KA TP for 05, 2, 1 KVAR = 5 Nos,(viii) Power Capacitor1 X 25 + 2 X 20 + 2 X 10 + 2 X 5 + 2 X 2 + 1 KVAR, (ix) Power Capacitor 5 KVAR with MCB 16 A 10 KA TP Fixed with Bus Bar - 1 No, (x) APFC Relay 10 Stage - 1 No, (xi) Indicating Red Light = 10 Nos, (xii) Auto manual selector switch = 10 Nos. Make of MCCB/MCB:- L&T/ HPL. Note:- The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 ( IS/IEC: 61439-1 ), 2011 & IS/IEC: 61439-2 ), 2011 ) 2. CPRI Short Circuit withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V, 4. ISO 9001 CERTIFIED
35supply and fix onload Change over switch 400 Amps, 415 volt with mounting fuse all as directed by Engr-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail