Housing Construction Circle has published Repair And Renovation Work Of Various Type And Various Qtrs 145 143 178 211 67 176 190 50 74 At Police Colony Hauz Khas New Delhi. Submission Date for this Tender is 29-11-2021. Building Repair Tenders in Police colony Hauz Khas Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
2 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
3 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
4 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
5 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
6 | Cement mortar 1:3 (1 cement :3 coarse sand) |
7 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
8 | Granite stone slab colour black, Cherry/Ruby red |
9 | Area of slab upto 0.50 sqm |
10 | Area of slab over 0.50 sqm |
11 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
12 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
13 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
14 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
15 | Providing and fixing to existing door frames. |
16 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
17 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
18 | Size of Tile 600x600 mm |
19 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
20 | Glazed Vitrified tiles Matt/Antiskid finish of size |
21 | Size of Tile 600 x 600 mm |
22 | 12 mm cement plaster of mix : |
23 | 1:4 (1 cement: 4 fine sand) |
24 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification. |
25 | Two or more coats on new work |
26 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
28 | Two or more coats on new work |
29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
30 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
31 | With cement mortar 1:4 (1 cement : 4 fine sand) |
32 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
33 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin- Charge. |
34 | Internal Work- Exposed on wall |
35 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
36 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
37 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
38 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge |
39 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
40 | 15 mm to 40 mm nominal bore |
41 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: |
42 | Up to 150 mm diameter |
43 | Dismantling of flushing cistern of all types C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
44 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
45 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
46 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
47 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
48 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
49 | White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap |
50 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
51 | Kitchen sink with drain board |
52 | 610x510 mm bowl depth 200 m |
53 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
54 | Flexible pipe |
55 | 40 mm dia |
56 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
57 | Providing and fixing soil, waste and vent pipes : |
58 | 100 mm dia |
59 | Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
60 | 75 mm diameter : |
61 | Centrifugally cast (spun) iron socketed pipe as per IS: 3989 |
62 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : |
63 | 75 mm dia pipe |
64 | 100 mm dia pipe |
65 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
66 | 100 mm dia |
67 | Sand cast iron S&S as per IS - 3989 |
68 | 75 mm dia |
69 | Sand cast iron S&S as per IS- 3989 |
70 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
71 | 100 mm inlet and 75 mm outlet |
72 | Sand cast iron S&S as per IS - 3989 |
73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
74 | 20 mm nominal dia Pipes |
75 | 25 mm nominal dia Pipes |
76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
77 | 25 mm nominal dia Pipes |
78 | 32 mm nominal dia Pipes |
79 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
80 | 45 cm length |
81 | 15 mm nominal bore |
82 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
83 | 100 mm diameter |
84 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
85 | Providing and fixing PTMT bib cock of approved quality and colour. |
86 | 15mm nominal bore, 86 mm long, weighing not less than 88 gms |
87 | Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms |
88 | Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms |
89 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : |
90 | 150 mm diameter |
91 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : |
92 | 150 mm diameter S.W. pipe |
93 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
94 | 100x100 mm size P type |
95 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
96 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : |
97 | 100 mm diameter |
98 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : |
99 | First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. |
100 | Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
101 | The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
102 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
103 | 75mm average thickness |
104 | Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of "L" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. |
105 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
106 | Group B |
107 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
108 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
109 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
110 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
111 | (i)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
112 | (ii)2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
113 | Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
114 | i) 3 x 1.5 sq. mm |
115 | ii) 3 x 4 sq. mm |
116 | iii) 3 X 6 sq. mm |
117 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
118 | (i) 20 mm |
119 | (ii) 25 mm |
120 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
121 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
122 | 1 or 2 Module (75 mmX75 mm) |
123 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
124 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
125 | Supplying and fixing call bell/buzzer suitable for DC/AC single phase 230 volts, complete as required as per the direction of engg -in- charges. |
126 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. |
127 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
128 | Supply, installation, testing and commissioning of 1200 mm (nominal size), 30 watt / 36 watt LED batten luminaire in aluminium housing with minimum light output 100 lumen/watt complete with all accessories, electronic driver,diffuser, directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. ( Makes : Philips / GE/ Havells/ Wipro/ Crompton/Jaquar ) |
129 | Supply, installation, testing and commissioning of 12 Watt /15 Watt surface mountedLED downlighter luminairecomplete with all accessories and electronic driver, directly on ceiling / wall, including connections etc. as required. Makes : Philips / GE/ Havells/ Wipro/ Crompton/Jaquar) |
130 | Supply, installation, testing and commissioning ofwallmounted light fixture complete with B22 base, diffuser and15 watt LED blub etc as requireddirectly onwall, including connections etc. as required. (Approved Makes:- Havells City 3 Wall light /orequivalent model Philips / Wipro/ Crompton /Jaquar) |
131 | Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc. as required. |
132 | 6 Module |
133 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
134 | 10 Amp Modular switch |
135 | 20 Amp Modular switch |
136 | 3 pin 10 Amp socket outlet |
137 | 6 pin 20/25 Amp Socket outlet |
138 | Supplying and fixing PolycarbonateBattan/Angle holder with 8/10 watt LED bulbincluding connection etc. as required. |
139 | Supply, installation, testing and commissioning of 10 watt LED bulkhead fittings with IP 66 ingress protection complete with all accessories and electronic driver, etc as requireddirectly onwall, including connections etc. as required.Makes : Philips / CG/ Havells/ Wipro/ Crompton/Jaquar ) |
140 | Supply, installation, testing and commissioning of 600 mm (nominal size) 9/10 watt LED batten luminaire with minimum light output 100 lumen/watt complete with all accessories, electronic driver,diffuser, directly on ceiling/ wall, including connectionsetc. as required. ( Approved Makes :- Wipro Garnet 10W LED Batten or equivalent model of Havells/ Crompton / Philpis / GE) |
141 | Supplying, Installation, testing and commissioning ofBEE 5 star rated, 1200 mm sweepceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. Makes :- Crompton /Havell"s / Usha / Orient ) |
142 | Supplying, installation, testing and commissioning of 30 W LED based Flood light luminaire,housing made up of pressure die cast aluminium / aluminium alloy, complete withdriver, cover andmountingbracket etc including installation directly onwall andconnection with 3 X1.5 sq.mm FRLS PVC insulated copper wire etc as required. The fixture should have a minimum system efficacy of 100 lumen/Watt, ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK >=05.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=3KV, PF >0.9 and THD<20%. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance.LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. (Approved Make: Phillips MODEL NO.BVP120 LED 35 CW FG S1 PSU GR OR similar in Schreder/ Lighting Science / GE/ Philips/ Jaquar ) |
143 | Supplying and installation of 300 mm sweep, 1400 RPM heavy dutyexhaust fan complete with louvers/shutters in the existing opening, including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required.(Havells makeISI markHeavy Duty Exhaust Fan or with similar specifications Crompton/Havells / Orient / Usha / Almonard) |
144 | Supplying and installation of fresh air fanwith louver shutter 250 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required. (Havells make Ventil Air-DX with self opening louvers or with similar specifications CG / Orient / Usha / Almonard/Havells ) |
145 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
146 | 12 way , Double door |
147 | Supplying and fixing 5 amps to 32 amps, 240 Volts "C" series MCB"s suitable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc as reqd. . |
148 | a) Single Pole |
149 | b) Double Pole |
150 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.. |
151 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required. |
152 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required |
153 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
154 | Dismentling of old surface / recessed wiring and distribution board of 01 no Type - III qtr and making the damage good etc as required as per direction of engg.-in-charge. |
155 | Less for cost of dismental material retrieve from the Qtr/ buildings which will be kept by the contractor i.c Cu/Al conductor PVC insulated wire, switch box, PVC/MS conduit pipe, accessories, Old fans and other electrical fitments etc complete as reqd. |