8833 / 2021-22 / E8 Repair Maintenance Of External Water Supply Distribution Lines And Certain Connected Works At Hww Ticca Area At Dalhousie, AGE(I) Dalhousie-Himachal Pradesh

Military Engineer Services-MES has published 8833 / 2021-22 / E8 Repair Maintenance Of External Water Supply Distribution Lines And Certain Connected Works At Hww Ticca Area At Dalhousie. Submission Date for this Tender is 21-12-2021. Pipe Laying Tenders in AGE(I) Dalhousie Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29994643
Corrigendum : 8833 / 2021-22 / E8 Repair Maintenance Of External Water Supply Distribution Lines And Certain Connected Works At Hww Ticca Area At Dalhousie
Open Tender
Indian
Himachal Pradesh
AGE(I) Dalhousie
21-12-2021

Tender Details

8833 / 2021-22 / E8 Repair Maintenance Of External Water Supply Distribution Lines And Certain Connected Works At Hww Ticca Area At Dalhousie

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 16000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/ MAINTENANCE OF EXTERNAL WATER SUPPLY, DISTRIBUTION LINES, AND CERTAIN CONNECTED WORKS ATHWW, TICCA AREA AT DALHOUSIE.
Sl. No. Item Description
1M&L for draining out water from semi undergroung water storage tank of capacity 41000 Gallon scraping out bleachin residual, sediments, sand, fungues scaling etc from inside, bottom and wall of water storage tank with the help of wire brush, steel Patti broom and jute bags and taking out same from the water storage tank and throwing at a distance not less than 25 mtr away from the water storage tank, cleaning inside the water storage tank and then washing and flushing out with fresh water till the entire satisfaction of Engr-in-Chargeand writing the date of cleaning on water tank wall with black/white enameld paint after cleaning of external wall surface of the tank with wire brush and remove all busses and algae neatly and painting of GI sheet of the top of the tank with green colour 2 coat of enameled paint all as specified and directed by Engineer-in-Charge (At Ticca Area - 02 Nos)
2All as per above srl Item No. 1 here in before but 20000 Galon Capacity complete all as directed by Engineer-in-Charge. (At Ticca Area - 02 Nos & Gemini area -01 No)
3All as per above srl Item No. 1 here in before but 10000 Galon Capacity complete all as directed by Engineer-in-Charge. (At Ticca Area - 01 Nos)
4All as per above srl Item No. 1 here in before but 10000 Ltr Capacity PVC tank including changing of broken tank cover with locking arrangement complete all as specified and directed by Engineer-in-Charge. (At Ticca Area - 03 Nos)
5Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in Hard/dense soil including taking out and laying of GI pipe complete all as specified and directed.
6Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
7Removing excavated materials n.exc 50m and depositingwhere directed at a level n.exc 1.5m above the Starting point.
8M&L for Taking up or down galvanized steel tubing with complete fitting for refixing or removal of worksite complete all as specified and directed by Engineer-in-charge.
9(a) 15mm bore
10(b) 20mm bore
11(c) 25mm bore
12(d) 40mm bore
13(e) 50mm bore
14(f)80mm bore
15(g) 100mm bore
16Supply and laying in trench/fixed on wall/floors galvanized steel water tubing medium grade ISI marked of the following sizes incl all fittings such asbends elbows, tees, short pieces, connectors, back nuts, diminishingpieces, caps and pigs, unions etc. complete all as directed . Make Jindal/Tata/Prakash Surya/Zenith.Note :- Necessary excavation and earth work shall be measured and paid separately
17(a) 15mm bore
18(b) 20mm bore
19(c) 25mm bore
20(e) 40mm bore
21(f)50mm bore
22(g) 80mm bore
23(h) 100mm bore
24Laying only in trench/fixed on wall/floors galvanized steel water tubing medium grade ISI marked of the following sizes incl all fittings such asbends elbows, tees, short pieces, connectors, back nuts, diminishingpieces, caps and pigs, unions etc complete all as directed . Make Jindal/Tata/Prakash Surya/Zenith.Note :- Material are issued by department for under free for layingand necessary excavation and earth work shall be measured and paid separately
25(a) 20mm bore
26(b) 25mm bore
27(c) 40mm bore
28(d) 50mm bore
29(e)80mm bore
30(f) 100mm bore
31S&F gunmetal globe or gate valve with iron wheel head screwed bolt ends for iron pipe of the following sizes complete incl taking down old gate valves all as specified and directed by Engineer-in-charge. Make : Leader/Zoloto
32(a) 15mm bore
33(b) 20mm bore
34(c) 25mm bore
35(d) 40mm bore
36(e) 50mm bore
37Taking out U/S CI sluice valve for the following sizes, supply and fixing new CI sluice valves Class PN1.6 confirming to ISI with flaged ends both ends with gun metal/steel spindle, round wheel incl jointing materials complete all as directed. Make Sant/Durga/Kirloskar/Kartar/UpadhyayISI :-
38(a) 80mm bore
39(b) 100mm bore
40Removing the existing sluice valve of the following sizes and takinng out the worn out gate and spindle refixing back the gate supply and fixing the new spindle made out of stainless steel rod of suitable size to fix the existing gate inc check nut regrindingof the gate fixing of nuts bolts gaskets etc complete all as specified:
41(a) 80mm bore
42Supply and fixing Ball brass valves high pressure with polythene flote and flynut complete secewed for iron pipe or brass feerrule 20mm dia including taking down u/S valve complete all as specified and directed by Engineer-in-Charge.
43M&L for Cutting the existing CI/GI pipe 80/100 mm bore or screwing existing CI/GI pipe for addn or altn as required on site including GI fiitings complete all as directed. Note: Necessary earth work shall be measured and paid separately.
44Opening the pump and motor for inspection and repairs and replacing the worn out parts with new parts as orderd under respective items and cleaning oiling, greasing and making the pump motor fully functional and reassemble the pump and motor as per original assembly inc cleaning the exposed surface of pump and applying one coat of synthetic enamel paint inc replacenment of worn out minor items such as packing bolts nuts and Gaskit etc with new parts inc testing complete all as specified and directed by the Engr-in-Charge for the following pump sets:
45(a) Centrifugal/Monoblock pumpset 0.5 HP to 3 HP Signle phase, 415 Volts
46(b) Centrifugal pumpset 5 HP 3 phase, 415 volts
47Note: Cost of Rewinding and spare parts of the pupmsetshall be measured and paid separately.
48M&L for dismantling of centrifugal/monoblock pump set and transportation of nearset wokshopand return back after completer repair and refixing the pump set at same place and connected all cable connection and mounting properly withcomplete testing all as specified and directed by Engineer-in-Charge.
49M&L for Rewinding the following Centrifugal/Monoblock pumpsets with winding wire of appropriate gauge and weight and suitable make as per original winding after removing the existing inc providing same class insulation all as directed:
50(a) Monoblock pumpset 1 HP to 3 HP single phsse, 415 Volts
51(b) Centrifugal pumpset 5 HP 3 phase, 415 volts
52S&F the following spare parts for Centrifugal pumpsets of capacity 5 Hp 3 phase 415 volts of any make complete all as directed.
53(a) Impeller for pump
54(b) Bearing for pump set
55(c ) Pump shaft
56(e) Rubber bushing for coupling
57Suply and fix Air release valve metal cased body of the following capacity inc removing of the U/S and testing complete all as directed with by pass arrangements:-
58(a) 80mm bore
59Repairs to Mechanical water level indicator including replacing steel wire rope, floot valve and welding of broken stand, scrapping of existing paint and painting with enamel paint over a coat of redoxide and marking of level for sump of any capacity complete all as specified and directed by Engineer-in-Charge.
60Supply and fix in replacement of MU-G6 DOL Starter on line starter suitable for submersible pump, 6 Hp 4.5 KW 3 phase including contol wiring & motor protector assembley having dry run protection, phase sequence corrector, earth leakage protection, single phase protection, high voltage and low voltage, time delay power programme time switch complete Model No ;- MU-G6 DOL Starter , Cat No. SS97756 make ;- L&T all as specified and directed by Engineer-in-Charge.
61M&L for LED display PVC board for Ticca area water supply installtion and inside the borad moulded letter for writing 75/150 mm hight illuminated after provide to power supply for the board and letters are display on the board for" AGE (I) DALHOUSIE (WATER SUPPLY INSTALLATION No-1 AT TICC AREA) " on top of the board with one side MES Logo and another side div sign on the board complete with fixing arrangement of the board in the ground with suitable size Angle iron frame and should be min.1.5mtr above ground level and 100mm bleow ground level with proper groutingby using of PCC work including exc. and removel of soil complete all as specified and directed by Engineer-in-Charge.
62M&L for LED display PVC board for Ticca area water supply installtion and inside the borad moulded letter for writing 75/150 mm hight illuminated after provide to power supply for the board and letters are display on the board for" AGE (I) DALHOUSIE (WATER SUPPLY INSTALLATION No-2 AT TICC AREA) " on top of the board with one side MES Logo and another side div sign on the board complete with fixing arrangement of the board in the ground with suitable size Angle iron frame and should be min.1.5mtr above ground level and 100mm bleow ground level with proper groutingby using of PCC work including exc. and removel of soil complete all as specified and directed by Engineer-in-Charge.
63M&L for LED display PVC board for HWW punchpulla main water supply installtion and inside the borad moulded letter for writing 75/150 mm hight illuminated after provide to power supply for the board and letters are display on the board for" AGE (I) DALHOUSIE (MAIN WATER SUPPLY INSTALLATION AT HWW PUNCHPULLA ) " on top of the board with one side MES Logo and another side div sign on the board complete with fixing arrangement of the board in the ground with suitable size Angle iron frame and should be min.1.5mtr above ground level and 100mm bleow ground level with proper groutingby using of PCC work including exc. and removel of soil complete all as specified and directed by Engineer-in-Charge.
64M&L construction of brick masonary valve pit built wn cement mortar 1:6 including all excavation and earth work in any type of soil and disposal of surpluse soil to a distance not exc. 50 mtr all as directed by Engineer-in-charge including 10mm thick plastering internally in CM 1:4 and flush pointing in same mortar to brick work externally as work proceeds and cement concrete in foundation PCC (1:4:8) type D-2 15 cm thick & PCC 1:3:6 type C-1 coping, including 75 mm thick & hard core of gauge and exc. 63mm using broken stone /bolder, MS sheet cover 3.15 mm thick MS angle iron frame, handle locking arrangement and painting to steel surfaces including dismantling of old valve pit complete all as specified and directed by Engineer-in-Charge. incl necessary excavation earth work of the followingsizes :-
65(a) 900 mm x 900mm x 900mm.
66(b) 1200mmx1200mmx1200mm
67M&L Rolled mild steel in compound girders and stanchions lattice girders, arial masts, stagingand the like including caps , bases, splices etc. built up from two or more beam or channel sections or angles with plates including all lattice bars, stiffeners, gusset plates,wire meshetc. conforming to Fe 410-W (Gde-E-250) quality -A, for fabrication of shed of pump room with painting of surface for one coat of primer and two coat of enamenled paint all as specified and directed by Engineer-in-Charge.
68Supply only chlorine chemical test kit in replacement of old u/s kit for testing of water complete all as specified and directed by Engineer-in-Charge.Make: Declibac Tech. Pvt Ltd. or equivalent.
69Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed
70M&L 15mm thick cement plaster (1:6) on fair faces of brick work or concrete surfaces complete all as specified and directed
71M&L for preparation of new distampered surfaces of walls and applying two finsishing coat of oil bound distamper (oil emulsion ) on walls, incl 3mm thick wall care putty, complete all as specified and directed
72M&L for Applying two coats of white wash on new wall surface including preparation of surface complete all as specified and directed
73Hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed
74M&L 75mm thick PCC type C-2 (1:3:6) using 40mm graded stone aggregate as in sub-base complete all as sprecified and directed
75Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in & raming earth/ briken rubble mixed with earth around, in layers n. exc. 25 cm watering, & removing surplus soil to a distance n exc 50m & making good surface in Hard/ldense soil. complete all as specified and directed.
76S & F mild steel security chain link fancing 60mm x 60mm with PVC coated mesh made out of 3mm dia MS wire and 1.00mm thick PVC coating including binding wire complete all as specified and directed
77M&L 75mm thick PCC type B-2 (1:2:4) using 40mm graded stone aggregate as in sub floor, sub, floors and pavings etc complete all as sprecified and directed
78M&L for chequred cement concrete tiles 20cm x20cmx25mm thick set, joined and pointed in neat cement slurry in floors with grey cement and pigment including 15 mm thick screed bed in CM 1:6including taking down old surface complete all as specified and directed
79S&F in Test point terminal block made of gun metal or phosphorus bronze size 75x75x5mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. head screw complete all as specified and directed by Engr-in-Charge.
80S & F in replacement aluminium strip of size 25 x 3.15 mm fixed with porcelain/PVC saddles and fixing screws etc minimum tow number saddles with screws on and including PVC guttis in each one mtr of length for roof conductors and down conductor above ground complete all as specified and directed
81S&F in replacement of air termination single pointed aluminium rod 12 mm dia and 300 mm long and fixed including taking out old ari termination rod complete all as specified and directed.
82M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 25 x 4mmby means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soilto a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 40mm dia mediumgrade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown inelectrical "plate No "3" and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy