| 1 | Taking down old street light fitting for repairing/replacement/cleaning of any Wattage, completely removing dead insect, dust and refixing again to same location all as specified and as directed. Note:- Replacement of accessories like driver shall be measured & paid separately. |
| 2 | S&F in repairLED Driver unit for LED Street light Luminaire72 W complete all as specified and directed. |
| 3 | S&F in repair LED Driver unit for LED Street light Luminaire60 Wcomplete all as specified and directed |
| 4 | S&F in repairLED Driver unit for LED Street light Luminaire90 W Complete all as specified and directed. |
| 5 | S&F in repairLED Driver unit for LED Street light Luminaire120 Wcomplete all as specified and directed. |
| 6 | S&F in repairLED Driver unit for LED Flood light Luminaire100 Wcomplete all as specified and directed. |
| 7 | S&F in repairLED Driver unit for LED Post top Luminaire25 W completeall as specified and directed. |
| 8 | S&F in repairs cable junction boxes IP 66/69 protected “halogen free and weather proof” suitable for outdoor type ( with metric knockouts for cable entry) of size 155 x 210 x 92 mm including necessary suitable size new backelite connecting terminals mounted on saddles suitable for 3 phase with neutral system - 04 Nos of suitable length and thickness and connecting the incoming & out going LT cable connections in the terminal block of junction box and fixing clamps made up of GI flat of size 32 x 6 mm of suitable length-02 Sets, including GI nut and bolt and washers on poles complete all as specified and as directed. |
| 9 | Taking out old concrete poles of 9M long embedded in concrete upto bottom of foundation and Supply Prestressed concrete pole, 9 m long, 102 X 152 mm at top and 102 X 289 mm at bottom, class-10 and errect in position complete all as specified and directed. |
| 10 | Taking out old concrete poles of 11M long embedded in concrete upto bottom of foundation and Supply Prestressed concrete pole, 11 m long, 152 X 152 mm at top and 152 X 260 mm at bottom, class-9 and errect in position complete all as specified and as directed. |
| 11 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work for concrete pole, pathway and stay foundation complete all as specified and directed. |
| 12 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work for pole coping complete all as specified and directed. |
| 13 | Taking down/Dismantling insulators carefullyany type, any size complete all as specified and as directed. |
| 14 | S & F Pin typeporcelain vitreous brown or white insulator suitable for 1100 Volt working pressure of size 100 mm height, 65 mm dia including one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete including dismantling existing old insulator from position complete all as specified and directed. |
| 15 | S & F shackle typeporcelain vitreous brown or white 1100 Volt of size, 115 mm dia and 100mm height including GI strap of size of 31 X 5 mm insulator bolt of 14mm dia, nuts and washers for working pressure 1100 V complete including dismantling existing old insulator from position complete all as specified and directed. |
| 16 | Taking down carefully aluminium conductor of any size from LT OH Lines after unbinding from insulators for replacement of multi jointed / undersize conductors complete all as specified and directed. |
| 17 | M&Lfor providing OH ACSR conductor of size 6/1 x 2.59 Sqmm including stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete all as specified and directed |
| 18 | Dismantling of MS cross arms bracing support clamps nuts bolts and washers etc andM&L for cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles including painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces complete all as specified and directed |
| 19 | Taking out old LT UG cable from any type of soil upto 16 Sqmm 4 core complete all as specified and directed |
| 20 | M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area16 Sqmm 4 core complete all as specified anddirected.Note:-Excavation in trench for laying the cable shall be paid seperately. |
| 21 | M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area10 Sqmm 2 core complete all as specified anddirected.Note:-Excavation in trench for laying the cable shall be paid seperately. |
| 22 | M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area6 Sqmm 2 core complete all as specified anddirected.Note:-Excavation in trench for laying the cable shall be paid seperately. |
| 23 | Excavation in trenches n.exc 1.5 m deep and n.exc 1.5 m wideand getting it out in soft/ loose soil for erection of pole/laying of cables complete all as specified and directed |
| 24 | All as per Item No.23 but in hard dense soil complete all as specified and directed |
| 25 | Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata complete all as specified and directed |
| 26 | Removing surplus excavated soil to a distance n.exc 50m, depositing where directedat a level n.exc 1.5m above the starting point complete all as specified and directed |
| 27 | Supply and laying of DWC pipe IS-16205 Part II, size inner dia 32 mm, outer dia 40 mm for cable protection in wall /trenches/floors complete all as specified and directed |
| 28 | Supply and Fixing of DWC pipe SNAP-FIT COUPLERIS-16205 Part II size inner dia 32 mm, outer dia 40 mm for connection of DWC Pipe in wall/trenches/floors complete all as specified and directed |
| 29 | Taking down old street light fitting or flood light, garden lights fitting any type and rating from poles, walls or any other indicated situation/location including removal of GI bracket pipe from site complete all as specified and directed. |
| 30 | Fixing only of Integral LED Flood light luminaire upto 120 W and connecting up with twin core twisted flexible aluminium conductor cable connector complete all as specified and directed. Note: LED fittings shall be supplied under schedule B store free for fixing only. |
| 31 | Fixing only Integral LED street light luminaire upto 120 Wattand connecting up with twin core twisted flexible aluminium conductor cable connectorcomplete all as directed . Note : LED fittings shall be supplied under schedule B store free for fixing only. |
| 32 | Supply and fix Analogue type timer switch (Daily time switch) including power contactor 25 Amps, three phase, 415 volts and MCB TPN 32 Amps 10 KA \"C\" series with arrangement of auto/mannual control switch duly prewired and bypass arrangement and including sheet metal enclosure of 2 mm thick CRCA sheet of adequate size with powder coated for enclosing the time switch with necessary fixing arrangements on PCC pole/wall surface by providing MS flat iron clamps 32x6 mm and nuts, bolts, washers etc complete all as specified and directed. |
| 33 | Supply and fix in repairIntegral LED Flood Light Luminaire100 W clamp typeComprises a pressure dicast aluminium housing with LEDs and driver, heat resistant toughened glass with frame suitably gasketed for IP 65 Class I protection including all accessories, complete all as specified and directed. |
| 34 | Supply & Fixin repair 25W LEDSmart Integrated Solar Street Light with Built in Mono Crystalline Panel, Lithium Ferro Phosphate (LiFeP0 4 ) Battery, MPPT Charge Controller and PIR Sensor with Colour Temperature 6000-6500K. Solar Standalone Streetlight Systemof 2 days backupconsists of Solar LED Luminiare, Solar Panel, Solar maintenance Free Battery and 6 Mtr GI Pole complete all as specified and directed.Note:- Cost of suitable concrete foundation for fixing the street light pole shall be deemed to be included in the quoted rate. |
| 35 | S & F in repair GI pipe medium grade 40 mm dia, 1.2 m in length,bent to shape for fixing street light fitting fixed with necessary clamps, bolts nuts etc., complete all as specified and directed. |
| 36 | Supply and fix2.5 Sqmm three core PVC insulated and PVC sheathed multistranded copper conductor cable 1100 Volt grade draw from junction box / OH ACSRto street light fitting complete all as specified and as directed. |
| 37 | M&L for preparation of old cement coated surface, cleaning the surface of the RCC pole (LT) above theground level including coping area with 2 coats of exterior Emulsion paint over a coat of cementprimer after preparation of surface including 12 cm black paint around the polenumbers/letters in white columns complete all as specified and as directed. |
| 38 | Re- Stringing only existing LT OH line including replacing of existing old binding wire with new complete all as specified and directed. Note : Restringing of 2 wires shall be measured as one RM |
| 39 | M&L for Surface dressing for removing of creeperson stay wires/polesnot exc 15cm deep in soft and loose soil complete all as specified and directed. |
| 40 | Cutting and trimming of tree branches 3 mtr all around of any size obstructing lumination of street light and touching LT / HT Over head line including removing trimmed tree branches complete all as specified and directed. |
| 41 | S & F in repair of Integral LED street light luminaire 90 W LED street light with pressure die-cast housing and toughened glass and individual LEDs with secondary lens optics for City Road application with IP66 ingress protection and impact resistance of IK07. 5kV inbuilt and 10kV external surge protection with Top opening driver cover for easy maintenanceand accessories complete all as specified and directed . |
| 42 | Supply and fixing in repair 40 watt integral pole mounted LED post top made in cast aluminium with decorative opal polycarbonate diffuser and IP 65 protection and accessories complete all as specified and directed |