}

Bids Are Invited For Structural Steel - S&F For Structural Steel Of Any Sectionfor Any Type Of Steel Structure Work Conforming To Fe 290 Gde-E-165 Including Cutting Holes In Walls For Fixing And Make Good The Desturb Areawith Necessary Brick Work/ Pcc/ Pl-Delhi

Indian Army has published Bids Are Invited For Structural Steel - S&F For Structural Steel Of Any Sectionfor Any Type Of Steel Structure Work Conforming To Fe 290 Gde-E-165 Including Cutting Holes In Walls For Fixing And Make Good The Desturb Areawith Necessary Brick Work/ Pcc/ Pl. Submission Date for this Tender is 26-11-2021. Uniform Tenders in Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

29929518
Bids Are Invited For Structural Steel - S&F For Structural Steel Of Any Sectionfor Any Type Of Steel Structure Work Conforming To Fe 290 Gde-E-165 Including Cutting Holes In Walls For Fixing And Make Good The Desturb Areawith Necessary Brick Work/ Pcc/ Pl
Tender
Indian
Delhi
26-11-2021

Tender Details

Bids Are Invited For Structural Steel - S&F For Structural Steel Of Any Sectionfor Any Type Of Steel Structure Work Conforming To Fe 290 Gde-E-165 Including Cutting Holes In Walls For Fixing And Make Good The Desturb Areawith Necessary Brick Work/ Pcc/ Plaster And Prepartion On New Surface Of Steelapplying Two Coat Of Synthetic Enamal Paint Over One Coat Of Red Oxide Primer All As Specified . , Patch Reapir - M & L In Small Patch Repairs Cement Concrete Type B-0 1:2:4 (12.50Mm Graded Aggregate) As In Coping, Edging Pcc To Site Good At Door Chowket Bottem & Bed Block Incl Weathering,Slightly Rounded Or Chamfered On Edges Throating Including From Work Complete All As Specified And Directed By Engr-In-Charge. , Bricks - M&L For Brickwork With Subclass ‘B’ Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls Foredging At Roof In Single Layer Built In Cement Mortar 1:4, 25 Mm Thick 1:2:4 Pcc Coping At Top Of Brick Workand Plstering With 1:4 Cement Mortar With Wpc As Per Manufacture Instruction Including Two Coat Of Cement Base Paint Complete All As Specified And Directed. , Plaster - M & L For 15 Mm Thick Plasteringin Small Patch Works On Brick/Concrete Surfaces In Cement Mortar 1:4 Using Liquid Water Proofing Compound And Finished Even And Smooth Without Using Extra Cementin Roof Slab, Ceiling, Wall , Chaja/Roof Projection Corners/Edges And Door/Window /Ventiletor Edgeswhere Required To Make Site Good Including Taking Down The Old Loose / Unseviseble Cement Plaster Complete All As Directed. (Note: Water Proofing Compound Shall Be Measured & Paid Seperately) , Tarfelt - Demolition Of Existing Tarfelt In Small Patch Worksexc. .25 Sqmbut Not Exc 20 Sqm Of Any Description And Thickness On Roof Top Including Flashing And Junction Of Parapet Repair And Disposal Of Debris To Outside The Station Where Suitable For Contractor Complete All As Specified And As Directed. , Pcc - M&L For Pcc 1:2:4Type B-0 Using 12.5 Mm Graded Stone Aggregate Rcc Roof Slabs To Fill Undulations To Achieve Uniform Slope Complete All As Specified And Directed. , Rendering - M&L For Rendering Over Roof Slab 10 Mm Thick In Cm 1:3 On Concrete Surfaces Mixed With Water Proofing Compound @ 3% By Weight Of Cement And Finished Surfaces Fair And Even All As Specified And Directed. (Wpc Shall Be Measured And Paid Separately) , App - M&L In Small Patch Worksexc. .25 Sqmbut Not Exc 20 Sqm For App Based Modified Pre Fabricated Five Layer, 3 Mm Thick And Weighing Not Less Than 3 Kg Per Sqm Water Proofing Membrane Reinforced With Non Woven Polyester Mat 160 G Smith Black Finished Over Compatible Primer Conforming To Is-3488 @ 0.3 Lt/Sqm, Membrane Laid By Torch Application Side Over Lap Of 75 Mm And End Overlap Of 100 Mm Wide, Joint/Overlap Sealed With Torch Applications For Parapet Etc The Membrane Taken Up To 30 Cm And Then Inserted Inside The Parapet After Making Necessary Groove As Required After Necessary Preparation Of The Surface Comlete As Per Manufacturers Instruction All All As Directed By Engr-In-Charge. , Water Proofing Compound - Supply Only Liquid Water Proofing Compound. , Steel Window - S&F In Repair Works Steel Windows With Side Hung Shutters Including Projecting Type Hinges With Steel Handle, And Steel Peg Stay, Complete With Glazing Bars, Dovetailed Or Welded Complete All As Directed. , Rsut Cleaning - Reepair Works Like Cleaning Of Rusted Iron , Welding Of Broken Hinges/ Bars / Haldels Or Fitting And Fixers In Steel Windows/ Ventiletors/ Doors Of Size Exc .50Sqm But Not Exc 4 Sqm To Make Serviseble Or Easy To Use In Opening And Closing With Steel Frame Complete All As Directed. , Galss_3Mm - S&F 3 Mm Tk Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square N Exc 0.5 Sq. M In Each Panecomplete All As Directed. , Aluminium_Door - Providing And Fixing Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) Work For Doors, Windows, Ventilators And Partitions (Fixed Portions) With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Chief.Etc. Complete All As Specified Anddirected. , Aluminium_Shutter - Providing And Fixing Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings (Like Handles / Tower Bolts Etc) Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required Including All Fittings Shall With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.P. Brass/ Stainless Steel Screws All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Chief Etc. Complete All As Specified Anddirected. Note:- Floor Spring/Door Closer ,Glazing & Panelling Shall Be Measured And Paid Separatly , Glass_5.5Mm - S & F In Repair 5.5 Mm Thick Sheet Glass, Obscured Or Frosted, On One Side And Glazing With Rubber Bidding In Aluminium Frames In Squares Exceeding 0.5 Sq. M In Each Pane , Steel Work - S&F In Repair Works Mild Steel Framed Work Such As Angles, Flats, Squre Bars, Grills, Gratings, Etc. With Ends Of Bars Shouldered And/Or Riveted Or Forged Into Spikes, Framed Guard Bar; Barred Iron Doors; Door Frame, Ladders , Window Grilles/ Framesand Similar Work Conforming To Fe 290 Gde-E-165 All As Specified . , Setting Coat - M&L For Setting Coat 5Mm Thick, Trowelled To Even And Smooth Finish In Cement Mortar 1;2 In Ceiling All As Specified & As Directed By Engineer-In-Charge , White Wash_2 Coat - M & L For Preparing New Surfaces Of Ceiling 2 Coats Of White Wash In Celing Complete All As Specified And As Directed By The Engineer-In-Charge , Weather Coat - M&L For Complete Removal Of Existing Treatment In Old Plastered Wallsincluding Preparation Of New Or Old Plastered Surfaces And Applying Two Coats Of Weather Proof Emulsion (Apex Ultima) Of Electric Blue Or White Colour Over A Coat Of Exterior Wall Primer In (Projections Of Column/Wall/Edges Of Chajja, Roofs And Other Narrow Locations In Buildings Upto Ground Plus Three Floor) All As Specified And Directed. , Cement Base Paint - M&L For Complete Removal Of Existing Treatment On Walls Including Preparing Old Plaster Surfaces And Applying Two Coats Of Cement Based Paint All As Directed And As Directed , Oil Bound Distemper - M&L For Complete Removal Of Existing Treatment On Walls Including Preparing Old Plastered Surfaces And Applying Two Coats Of Oil Bound Distemper All As Directed And As Directed , White Wash_1 Coat - M & L For Preparing Old Surfaces Of Ceiliong, One Coats Of White Wash In Celing Complete All As Specified And As Directed By The Engineer-In-Charge , Synthetic Enamel Paint - M&L For Prepartion On New Or Oldsurface Of Steel & Iron Work Of Any Description Not Specifically Mentioned Otherwise Over 10 Cm Width Or Girth & Applying Two Coat Of Synthetic Enamal Paint Over One Coat Of Red Oxide Primer All As Specified & As Directed Total Quantity : 1

Key Value

Document Fees
Refer document
Tender Value
INR 7 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail