Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #29927116

Dnit For The Work Wqms Rewari 2021-22 Supply Of Bod Incubator, Cod Thermo Reactor, Cod System, Ph Meter, Conductivity Meter, Tds Meter, Do Meter With Optical Probe,Water Purification Unit, Manifold Filtration Assembly, Oxytop, Bod Respirometer, Jar T Dnit

Issued by Government Departments · District Laboratory, Rewari, Haryana
Tender Value
9.15 Lakhs
Estimated cost
Bid Submission
22 Nov 2021
0 days left
EMD
18300
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
District Laboratory, Rewari → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Dnit For The Work Wqms Rewari 2021-22 Supply Of Bod Incubator, Cod Thermo Reactor, Cod System, Ph Meter, Conductivity Meter, Tds Meter, Do Meter With Optical Probe,Water Purification Unit, Manifold Filtration Assembly, Oxytop, Bod Respirometer, Jar T Dnit For The Work Wqms Rewari 2021-22 Supply Of Bod Incubator, Cod Thermo Reactor, Cod System, Ph Meter, Conductivity Meter, Tds Meter, Do Meter With Optical Probe,Water Purification Unit, Manifold Filtration Assembly, Oxytop, Bod Respirometer, Jar T

BOQ

Name of Work: DNIT for WQMS - Rewari 2021-22 (29.35Lacs) Supply of BOD Incubator, COD Thermo-reactor / COD system, pH meter, Conductivity meter /TDS meter, DO meter with Optical Probe,Water Purification unit, Manifold filtration Assembly, Oxy-top/ BOD respirometer, Jar Testers/ floc tester all respect for DistrictLab at Public Health Engineering Division lab Rewari and all other works contingent there to.
Sl. No. Item Description
1BOD Incubator Make: -NST, Ambassador, Optics Technology with 5 years AMC Specification Inner Size: 18\" x 18\" x 24\", Rating Watts 750, No. of Shelves 3, capacity 120Ltrs Construction: Double walled construction outer body made of Mild Steel powder coated, & Inner Body made of Stainless-Steel Insulation: Glass wool insulation between two walls. Temp range: room temperature to 60°C. Accuracy: +/- 0.5 °C. Temp controlled by: Controlled by PID Micro process controller with dual display. Selves: With G.I. wire Mesh selves Door: 2 door inner acrylic door to view sample & outer metal door. with air circulation motor with blower for uniform temperature throughout chamber. Heater: special Nichrome heater designed for long life & saving of power consumption
2COD Thermo-reactor / COD system:Make :-Hach, WTW (Xylem)with 5 years AMC and With Chemicals and Standards for 200 Test Specifications Reflux Type Sealing Positions -12 Position, Capacity 16 mm X 100 mm vials, Heating Block Aluminium, Temperature Range Ambient to 180°C Temperature Accuracy ±1°C, Display LED Process Timer 0-999 min / Infinite Temperature Control Yes with Set value and Present value Time Control Yes with Set value and Present value Transparent Lid UV protection Power consumptions 200 W Current Consumption 1.5 A Unit External Dimensions (WxDxH) (275 X 185 X 150) mm. along with 12 Nos, Tubes.
3pH meter Make:- Eutech, WTW (Xylem)with 5 years AMC and Chemicals and with Standards for 200 Test Specifications pH Range - 0 to 14.00 pH; Batteries: 4 x 1.5 V alkali- manganese batteries, type AA; Operational life: Up to 800 h without / 100 h with illumination. Resolution/Accuracy 0.001 pH/± 0.005 pH; Operational life: Up to 800 h without / 100 h with illumination; Operation Temp - 0°C-100°C ORP Range ± 2500 mV; USB interface- USB B (device), data output; Admissible relative humidity- Yearly mean: < 75 %, 30 days/year: 95 %, Other days: 85 % \"Resolution 0.1 (± 1200.0mV) / 1 mV (beyond); EMC- EC directive 2004/108/EC EN 61326-1; Dimension: 240 x 190 x 80 mm; Weight 0.8 kg\" 1.2 ± 0.2 (± 199.9 mV) /± 2 mV (beyond) Temp range 0.0 to 100.00 C (32.0 to 212.00 F) Resolution/Accuracy 0.1 0 C (0.1 0 F)/±0.3 ºC / ±0.5 ºF (0 to 70 ºC) ATC Yes (0 to 100 0 ºC) Buffer Options USA: pH 1.68, 4.01, 7.00, 10.01,12.45 NIST pH 1.68, 4.01, 6.86, 9.18 ,12.45 No. of pH Calibration Points 5points Built-in Electrode Arm Yes Memory 100 data sets Electrode Included ECFC7252101B, single junction pH electrode. Temp Probe IncludedLCD DISPLAY CUSTOM dual-display LCD(5.6X7.5cm) Power Requirements Included, 100 /240VAC SMPS Power Adapter with US/UK/EUR/Japan plug ,9V,6W, CENTRE
4Conductivity meter /TDS meter Make: Hach, Eutech, with 5 years AMC And with chemical andStandards for 200 Test Specifications Conductivity 0.00- 1000 mS/cm; Batteries: 4x1.5 V alkali-manganese batteries, type AA Resolution0.001µS/ 0.01µS/0.1µS;1/0.01mS/ 0.1 mS; Operational life: Up to 800 h without/ 100 h with illumination Accuracy ±0.5 % of value (Salinity); USB interface - USB B (device), data output; Dimension: 240 x 190 x 80 mm Resistivity0.00-199.9MOcm;EMC-ECdirective 2004/108/EC EN61326-1 Resolution0.001/0.01/ 0.1O;0.001/0.1kO;0.01 MO Accuracy ±0.5 % of value (Resistivity) 0.0 -70.0 according to the IOT table Resolution 0.1; Weight 0.8 kg; IP Class: IP 43 Accuracy ± 0.1; Operational Temp: +5 °C ... +55 °C; Admissible relative humidity: Yearly mean: < 75 % 30 days/year: 95 %, Other days: 85 %\" TDSRange1…1999mg/l,0…199.9g/l(@TDSfactor 1.00) Resolution 1 ppm; 0.01 / 0.1 ppt; Accuracy ±0.5 % of value Temp Range -5.0 ... +105.0°C Resolution 0.1°C; Accuracy ± 0.1°C none, nlF, 0.000 … 10.000 %/K Reference Temperature 20 °C/25 °C Built-in Electrode Arm Yes Compensation ATC / MTC Memory 5000 data sets electrode Included, 4 cell graphite electrode, Conductivity electrode, K=0.475 \"Power Requirements Input: 100/ 240 V ~ / 50-60 Hz / 270 mA Output: 9 V = / 1.1 A
5DO meter with Optical ProbeMake: Hach, Thermofisher Scientific with 5 years AMC and Chemicals and with Standards for 200 Test Specifications Display:3.5\" color display DO barometer accuracy: ±3mbar DO barometer range: 300 - 1,100 mbar DO barometer resolution: 1mbar DO calibration points: 2 DO measuring accuracy mg/L: \"0.00 - 8.00 mg/L: ±0.1 mg/L 8.00 - 20.00 mg/L: ±0.15 mg/L 20.00 - 50.00 mg/L: ±10%\" DO measuring range % saturation: 0.0 - 500% DO measuring range mg/L: 0.00 - 50.00 DO measuring resolution % saturation: 0.1% DO measuring resolution mg/L: 0.01 DO response time: T99: <20 s DO salinity compensation: manual DO salinity compensation range 0.0 - 70.0 PSU DO selectable measuring units: % air sat; mg/L; ppm; µmol/L; mbar; torr; dphi DO temperature range: 0.0 - 60 °C DO temperature resolution: 0.1 °C Good Laboratory Practice (GLP):Yes, data with User ID, timestamp, electrode ID Measuring inputs: 2 Measuring mode: 1 x pH/U/T analog 1 x pH/U/T/DO digital Memory size: 10,000 measured values mV accuracy: ±0.2 mV mV range: -1,200.0 mV - +1,200.0 mV mV resolution: 0.1 mV pH accuracy: ±0.003 pH pH calibration points: 1 – 5 pH range: -13.000 - +20.000 pH resolution: 0.001 pH Power supply: Lithium-polymer rechargeable battery 3.7 V; 3,000 mAh Protection class: IP 67
6Water Purification unit Make: -Merck Millipore with 5 years AMC Specification Water Purification system for preparation of Mobile phase and standards with following specifications should be quoted. Pre-filtration system: Three stage pre-treatment system with 10, 5 & 1 micron spun filters for removal of suspended particles and to take care of F.I in water. Microprocessor - controlled management systems for continuous monitoring of water purity. Should produce Ultra-Pure water (Type 1) from tap water for different applications. It should be single stage system with the filter at the tap. It Should have RO, DI and UV in a single unit; have an integrated docking vessel of 25 litre for storing the water to save space It should have recirculation facility to maintain consistent peak water purity. Instrument should show water volume in reservoir graphically and in percentage. It should have cartridge change indicator. The production rate of the unit should be minimum 7 Litre/hr or more and the dispense rate should be minimum 1.0 L/min It should have dual wavelength UV (185/254 nm) The manufacturer must have worldwide presence. Product water quality specifications: Ultrapure (Type I) water specifications Resistivity: 18.2 MO.cm @ 25°C Dispense flow rate: Up to 1.2l/min; TOC <5 ppb Bacterial TVC <0.1 cfu/ml; Endotoxin: <0.001 Eu/ml Particulates: 0.2µm filtration Recommended daily volume: Up to 10l/day Pure (Type II) water specification Resistivity:>1MO.cm@25°C;TOC:<50ppb Bacterial TVC: <100cfu/ml Recommended daily volume: Up to 10 l/day
7Manifold filtration Assembly Make:-Merck Millipore with 5 years AMC and with Filter paper for 200 Test Specification - Display: LCD grahic, backlit, menu controlled Interfaces: USB SD-Card Measuring Principle: Manometric; mercury-free; electronic pressure sensor; Accuracy: ± 0.5% of the measured value ± 1 hPa Measuring Range: 0-40, 0-80, 0-200, 0-400, 0-800, 0-2000, 0-4000 mg/l; Resolutions: ± 0.1 mg/l; ± 1 ?h Pa, hPa Measurement Time: User-selectable, between 1 to 7 days Power Supply: 100 - 240 V / 50-60 Hz 3 alkali-manganese batteries (Baby cells/ size C) Auto – OFF: No Clock: Real Time Clock and Date Portability: Benchtop AutoStart: Yes Measuring Stations: 6 Compliance: CE EMC according to DIN EN 61326 Protection Class IP 54
8Oxy-top/ BOD respirometer Make:- Hach, Thermo Fisher Scientific with 5 years AMC and With Chemicals and Standards for 200 Test Specification Display: LCD grahic, backlit, menu controlled Interfaces: USB SD-Card Measuring Principle: Manometric; mercury-free; electronic pressure sensor; Accuracy: ± 0.5% of the measured value ± 1 hPa Measuring Range: 0-40, 0-80, 0-200, 0-400, 0-800, 0-2000, 0-4000 mg/l; Resolutions: ± 0.1 mg/l; ± 1 ?h Pa, hPa Measurement Time: User-selectable, between 1 to 7 days Power Supply: 100 - 240 V / 50-60 Hz 3 alkali-manganese batteries (Baby cells/ size C) Auto – OFF: No Clock: Real Time Clock and Date Portability: Benchtop AutoStart: Yes Measuring Stations: 6 Compliance: CE EMC according to DIN EN 61326 Protection Class IP 54
9Jar Testers/ floc testerMake:- Electronics India, Popular Traders with 5 years AMC Specification • Accepts six samples (40,000) • LED Digital Display• Digital indication of speed and timer • Digital timer from 0 to 99 minutes • Two pre-set programs • Built in illumination for easy viewing of sample • Speed range 25 to 200 rpm • Power-230V,50Hz,100 W

AI Tender Summary

OUR REF NO 29927116
AUTHORITY Government Departments
TENDER VALUE 9.15 Lakhs
LAST DATE 22-11-2021
Authority
Authority Name Public Health Engineering Department
Work Description Dnit For The Work Wqms Rewari 2021-22 Supply Of Bod Incubator, Cod Thermo Reactor, Cod System, Ph Meter, Conductivity Meter, Tds Meter, Do Meter With Optical Probe,Water Purification Unit, Manifold Filtration Assembly, Oxytop, Bod Respirometer, Jar T Dnit For The Work Wqms Rewari 2021-22 Supply Of Bod Incubator, Cod Thermo Reactor, Cod System, Ph Meter, Conductivity Meter, Tds Meter, Do Meter With Optical Probe,Water Purification Unit, Manifold Filtration Assembly, Oxytop, Bod Respirometer, Jar T
Basic Detail
Tender No 3474 dt. 27.08.2021
Bidding Type Tender
Location
City District Laboratory, Rewari
State Haryana
Key Dates
Publish Date 16 Nov 2021
Submission Date 22 Nov 2021
Open Date 23 Nov 2021
Finance
Tender Value 9.15 Lakhs
Tender Fee 1000
EMD 18300
Exemption Not Available
Document List
02708288-bf52-430f-9546-0d62c20fead3.html
BOQ_258289.xls
Labnotice.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 22, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 23, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

02708288-bf52-430f-9546-0d62c20fead3.html

xls

BOQ_258289.xls

pdf

Labnotice.pdf

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders