Petroleum and Natural Gas Statutory Bodies & Commissions/Committees Closing in 0 days TDR #29915194

Bids Are invited for 54215051Generator Differential Protection CTsfor GTG-5&6 - Generator Differential Protection CTsfor GTG-5&6Generator Differential Protection Current Transformer (CT for phase bus duct & CT for neutral bus duct ) for GTG-5&6, Tag no.

Issued by Statutory Bodies & Commissions/Committees · , Andhra Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Nov 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids Are invited for 54215051Generator Differential Protection CTsfor GTG-5&6 - Generator Differential Protection CTsfor GTG-5&6Generator Differential Protection Current Transformer (CT for phase bus duct & CT for neutral bus duct ) for GTG-5&6, Tag no. as per drawing: 1,2,3,10,11 &12 Make: Pragati, Resin Cast, Window type, Indoor, Current transformer, Voltage Class: 11KV, Ratio: 2000/1A, VA Burden : Not applicable, Accuracy Class: PS Knee point voltage (Min. in Volts),Vk: >=350V R sec. at 75 deg. centigrade: <=5 ohms Im at Vk/2:<=10mA Shortcircuit rating (STC) :40KA at 3 sec. Insulation Class: B One minute power frequency withstand voltage: 35KV (RMS) Impulse withstand voltage (1.2/50 micro sec wave):75KV peak Momentary rating: 102 KAP No. of phases: single Frequency: 50Hz Primary Conductor size: 1-127X48X12 Aluminum Channel/Phase Reference Standard: IS:2705/ IEC-185 CTshall be suitableto existing Pragati make current transformers in rating & dimensions. , 54215052 AVR CTsfor GTG-5&6 - AVR CTsfor GTG-5&6AVR Current Transformer (CT for phase bus duct) for GTG-5&6, Tag no. as per drawing: 4,5,6, Make: Pragati, Resin Cast, Window type, Indoor, Current transformer, Voltage Class: 11KV, Ratio: 2000/1A, VA Burden : 30VA, Accuracy Class: 0.2 Isf: <=5 Shortcircuit rating (STC) :40KA at 3 sec. Insulation Class:B One minute power frequency withstand voltage: 35KV (RMS) Impulse withstand voltage (1.2/50 micro sec wave):75KV peak Momentary rating: 102 KAP No. of phases:single Frequency: 50Hz Primary Conductor size: 1-127X48X12 Aluminum Channel/Phase Reference Standard: IS:2705/ IEC-185 CTshall be suitableto existing current transformers in rating & dimensions. , 54215053 MeteringCTsfor GTG-5&6 - MeteringCTsfor GTG-5&6Metering Current Transformer (CT for phase bus duct) for GTG-5&6, Tag no. as per drawing: 7,8,9, Make: Pragati, Resin Cast, Window type, Indoor, Current transformer, Voltage Class: 11KV, Ratio: 2000/1A, VA Burden : 75VA, Accuracy Class: 0.2 Isf: <=5 Short

AI Tender Summary

OUR REF NO 29915194
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 27-11-2021
Authority
Authority Name Ministry Of Petroleum And Natural Gas
Work Description Bids Are invited for 54215051Generator Differential Protection CTsfor GTG-5&6 - Generator Differential Protection CTsfor GTG-5&6Generator Differential Protection Current Transformer (CT for phase bus duct & CT for neutral bus duct ) for GTG-5&6, Tag no. as per drawing: 1,2,3,10,11 &12 Make: Pragati, Resin Cast, Window type, Indoor, Current transformer, Voltage Class: 11KV, Ratio: 2000/1A, VA Burden : Not applicable, Accuracy Class: PS Knee point voltage (Min. in Volts),Vk: >=350V R sec. at 75 deg. centigrade: <=5 ohms Im at Vk/2:<=10mA Shortcircuit rating (STC) :40KA at 3 sec. Insulation Class: B One minute power frequency withstand voltage: 35KV (RMS) Impulse withstand voltage (1.2/50 micro sec wave):75KV peak Momentary rating: 102 KAP No. of phases: single Frequency: 50Hz Primary Conductor size: 1-127X48X12 Aluminum Channel/Phase Reference Standard: IS:2705/ IEC-185 CTshall be suitableto existing Pragati make current transformers in rating & dimensions. , 54215052 AVR CTsfor GTG-5&6 - AVR CTsfor GTG-5&6AVR Current Transformer (CT for phase bus duct) for GTG-5&6, Tag no. as per drawing: 4,5,6, Make: Pragati, Resin Cast, Window type, Indoor, Current transformer, Voltage Class: 11KV, Ratio: 2000/1A, VA Burden : 30VA, Accuracy Class: 0.2 Isf: <=5 Shortcircuit rating (STC) :40KA at 3 sec. Insulation Class:B One minute power frequency withstand voltage: 35KV (RMS) Impulse withstand voltage (1.2/50 micro sec wave):75KV peak Momentary rating: 102 KAP No. of phases:single Frequency: 50Hz Primary Conductor size: 1-127X48X12 Aluminum Channel/Phase Reference Standard: IS:2705/ IEC-185 CTshall be suitableto existing current transformers in rating & dimensions. , 54215053 MeteringCTsfor GTG-5&6 - MeteringCTsfor GTG-5&6Metering Current Transformer (CT for phase bus duct) for GTG-5&6, Tag no. as per drawing: 7,8,9, Make: Pragati, Resin Cast, Window type, Indoor, Current transformer, Voltage Class: 11KV, Ratio: 2000/1A, VA Burden : 75VA, Accuracy Class: 0.2 Isf: <=5 Short
Basic Detail
Tender No GEM/2021/B/1680381
Bidding Type Tender
Location
City
State Andhra Pradesh
Key Dates
Publish Date 17 Nov 2021
Submission Date 27 Nov 2021
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
2854363_Boq_2.xlsx
918f0b69-aaa8-4467-8e88-3552a7ee4ad7.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
xlsx

2854363_Boq_2.xlsx

pdf

918f0b69-aaa8-4467-8e88-3552a7ee4ad7.pdf

TenderDetail
Loading tenders