| 1 | HOSTEL BUILDING:- (G+1) Floor |
| 2 | Earthwork in excavation in hard soil for site leveling, foundation, pits, trenchesand other civil works upto and including 1.5metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. Hard soils. |
| 3 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. |
| 4 | Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-Charge. |
| 5 | Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand : 8 stoneagregate 40mm nominal size) as levelling course in floor and plinth including tempering, curring, shuttering etc. complete all depth and height. |
| 6 | First class Fly ash Brick masonry usingbricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. |
| 7 | First class Fly ash Brick masonry usingbricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super Structure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. Ground floor |
| 8 | First floor |
| 9 | Second floor |
| 10 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.Ground floor a) Footing |
| 11 | b) Pedestal :- |
| 12 | d) Column up to plinth |
| 13 | e) Plinth Beam |
| 14 | f) Column above plinth |
| 15 | g) Lintel |
| 16 | i) Roof Beam |
| 17 | j) Slab |
| 18 | k) Stair case |
| 19 | First floor f)Column |
| 20 | g) Lintel |
| 21 | i)Roof Beam |
| 22 | j) Slab |
| 23 | k) Stair case |
| 24 | Second Floorf)Column |
| 25 | g) Lintel |
| 26 | i)Roof Beam |
| 27 | j) Slab |
| 28 | Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/ TATA / RINL (VIZAG) make includingbending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (Linear measurement will be taken and quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor steel only. Wastage if any, including weight of binding wire will not be considered for measurement) etc. complete as per specification & direction of Engineer-in-chargeGround floor. |
| 29 | First floor |
| 30 | Second floor |
| 31 | 12mm cement plaster to outside of brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.Ground floor |
| 32 | First floor |
| 33 | Secondfloor |
| 34 | 16mm cement plaster to inside of brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. Ground floor |
| 35 | First floor |
| 36 | Second floor |
| 37 | 6 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1 cement : 4 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.Ground floor |
| 38 | First floor |
| 39 | Second floor |
| 40 | Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4)(1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-chargeGround floor |
| 41 | First floor |
| 42 | Supplying, fitting & fixing of10 mm thick& sizeof 600x600 mmGlazed Vitrified floor tiles (GVT) of matt finish(WOODEN FINISH/RUSTIC FINISH) with veilcraft (VC )shield( Scratch free/stain free) withwater absorption limitbetween 0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only ) Ground floor |
| 43 | First floor |
| 44 | Second floor |
| 45 | Supplying, fitting & fixing of Vertifiedtilesin dadoes, skirting and risers of stepslaid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-chargeGround floor |
| 46 | First floor |
| 47 | Second Floor |
| 48 | Supplying, fitting & fixing of10 mm thick& sizeof 300x300 mmCeramicfloor tilesof matt finish laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only )Ground floor |
| 49 | First floor |
| 50 | Supplying, fitting & fixing of Germ freeCeramic wall tiles of premium grade of size 600x300mm having thickness 6.5mm to 6.7mm confirming to IS 13753in dadoes, skirting and risers of stepslaid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge Ground floor |
| 51 | First floor |
| 52 | Factory made 30mm/32mm flush door shutter (Laminates both side of frame) with all labour, iron fittings, and wooden hinged cleats etc fitted and fixed complete in all respect Ground floor |
| 53 | Supplying Fitting, fixing up fully glazed aluminium framed window(sliding type) made up aluminiumsection 9778 as window frame, section 4095, 4096 and 9777, 3994 as shutter frame with 5mm black glass as panel fitted withrubber beading including locking arrangement including all fitting including cost of all materials, all taxes, labour, T&P excluding cost of glass etc. complete as per direction of the Engineer-in-chargeGround floor |
| 54 | First floor |
| 55 | Second floor |
| 56 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.Ground floor |
| 57 | First floor |
| 58 | Second floor |
| 59 | Painting two coats with approved anti-fungal weather seal paints (ISI) of approved colour, shade on wall surface over a coat of wall primer(ISI) water bound including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-charge.Ground floor |
| 60 | First floor |
| 61 | Second floor |
| 62 | Painting two coats with approved plastic emulsion paintover a coat of wall primer of make Dulux / Berger / Asian to inside surface of walls finishedwith Acrylic Wall putty (water based) ofmake (Birla / JK) and finished smooth & even surface to receive painting using roller to the final coat including cost of scaffolding staging charges with cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc. complete for all floors as per specification & direction of the Engineer-in-charge. Note :- Sample of Paint & Primer shall be approved before procurement and use. Ground floor |
| 63 | First floor |
| 64 | Second floor |
| 65 | Finishing plaster surface with water based wall putty of approved make , finishing the surface smooth and even by sand papering at all heights with staging including cost of conveyance, tax of all materials, labout, T&P etc for completing the work in all respect as per Engineer in charge.Ground floor |
| 66 | First floor |
| 67 | Second floor |
| 68 | Fitting fixing of wood plastic composite material, door frame and shutter.Ground floor |
| 69 | First floor |
| 70 | Second floor |
| 71 | Supply, fitting and fixing of stainless steel of 304 grade in hand railing using 50 mm dia of 2mm thick circular pipe with Balustrade of size 32 mm X 32mm X 2 mm @ 0.9 m C/C and stainless square pipe bracing of size 32 mm X 32 mm X 2 mm in three rows in staircase as per approved design and specification, buffling, polishing with all cost, conveyance, tax of all material, labour, T&P etc required for completing the work in all respect. |