Repair / Maint Including Replacement Of Runway Lighting Alongwith Connected Elect Items At Manasbal Grn Under Ge 970 Ews. Repair / Maint Including Replacement Of Runway Lighting Alongwith Connected Elect Items At Manasbal Grn Under Ge 970 Ews.
Tender Overview
Project Description
Repair / Maint Including Replacement Of Runway Lighting Alongwith Connected Elect Items At Manasbal Grn Under Ge 970 Ews. Repair / Maint Including Replacement Of Runway Lighting Alongwith Connected Elect Items At Manasbal Grn Under Ge 970 Ews.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Dec-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-Dec-2021 |
BOQ
| Sl. No. | Item Description |
| 1 | S&F in repair of existing NASU System electronic control and logical cards of convetional type Constant current regulator CCR panel thyristor controlled 230V, single phase, indoor type natural air cooled 5 position current steps 2.8A, 3.1A, 4.1A, 5.2A, & 6.6A rating 4 KW and output 606 VAC including calibration for sensitivity on site complete all as specified and directed by Engr-in-Charge and GE.Make : NASU system Mumbai or its equivalent compatible with existing system in Safegate/Manairco. |
| 2 | S&F in repair of existing NASU system electronic control and logical cards of convetional type Constant current regulator CCR panel thyristor controlled 415V, Two phase, indoor type natural air cooled 5 position current steps 2.8A, 3.1A, 4.1A, 5.2A, & 6.6A rating 7.5 KW and output 1137VAC including calibratoin for sensitivity on site complete all as specified and directed by Engr-in-Charge and GE.Make : NASU system Mumbai or its equivalent compatible with existing system in Safegate/Manairco. |
| 3 | S&F in repair of existing NASU system electronic control and logical cards of convetional type Constant current regulator CCR panel thyristor controlled 415V, Two phase, indoor type natural air cooled 5 position current steps 2.8A, 3.1A, 4.1A, 5.2A, & 6.6A rating 20 KW including calibratoin for sensitivity on site complete all as specified and directed by Engr-in-Charge and GEMake : NASU system Mumbai or its equivalent compatible with existing system in Safegate/Manairco. |
| 4 | Supply, laying, commissioning and testing in replacement of 6Sqmm copper control cable, solid annealed plain copper conductor PVC inner sheathed, XLPE power cable of single core 5KV grade confirming to IS upto date as required for runway lighting from RCD control panel or CCR panel complete all as specified and directed.Make : RAJLASON/Laab/Jindal. |
| 5 | Supply, laying, commissioning and testing in replacement of 16Sqmm copper control cable, solid annealed plain copper conductor PVC inner sheathed, XLPE power cable of single core 5KV grade confirming to IS upto date as required for runway lighting from RCD control panel or CCR panel complete all as specified and directed.Make : RAJLASON/Laab/Jindal. |
| 6 | Supply, installation, commissioning in replacement of bi-directional elevated type high intensity halogen runway edge light fitting with all accessories such as base plate, breakable coupling, mountingnassembly, gasket, lamp holder, lenses, secondary lead spring, stainless steel bolt, etc confirming to ICAO Annex 14, complete all as specified and directed by Engr-in-Charge.Make : AMA/VARDHMAN/AVLITE |
| 7 | Supply, installation, commissioning in replacement of omni-directional elevated type medium intesity halogen taxiway light fitting with all accessories such as base plate, breakable coupling, mountingnassembly, gasket, lamp holder, lenses, secondary lead spring, stainless steel bolt, etc confirming to ICAO Annex 14, complete all as specified and directed by Engr-in-Charge..Make : AMA/VARDHMAN/AVLITE |
| 8 | Supply, installation, commissioning in replacement of isolating transformer 5 KV, 50Hz series type encapsulated in polyster resin for all moulded with neoprene rubber as specified and suitable for Air field lighting system confirming to FAA/ICAO and IS-12290 1987 of capacity 200W, 6.6Amp, for runway lighting complete all as specified and directed by Engr-in-Charge.Make : AMA/VARDHMAN/AVLITE |
| 9 | Supply, installation, commissioning in replacement ofisolating transformer 5 KV, 50Hz series type encapsulated in polyster resin for all moulded with neoprene rubber as specified and suitable for Air field lighting system confirming to FAA/ICAO and IS-12290 1987 of capacity 45W, 6.6Amp, for runway lighting complete all as specified and directed by Engr-in-Charge.Make : AMA/VARDHMAN/AVLITE |
| 10 | Supply and fixing of 5 KV grade plug, receptacle of type-I Class B connector, suitable for field attachment with 5 KV grade PVC insulated, PVC sheathed single core copper conductor of size cable 6 Sqmm for runway lighting complete male female sets as specified and directed by Engr-in-Charge. Make : AMA/VARDHMAN/AVLITE |
| 11 | Supply and fixing of 5 KV grade plug, receptacle of type-I Class B connector, suitable for field attachment with 5 KV grade PVC insulated, PVC sheathed single core copper conductor of size cable 16 Sqmm for runway lighting complete male female sets as specified and directed by Engr-in-Charge. Make : AMA/VARDHMAN/AVLITE |
| 12 | Supply and fixing in replacement of runway Halogen lamp bipin 200W, 6.6 Amp, complete all as specified and directed by Engr-in-Charge. Make : AMA/VARDHMAN/AVLITE |
| 13 | Supply and fixing in replacement of taxiway Halogen lamp bipin 45W, 6.6 Amp complete all as specified and directed by Engr-in-Charge. Make : AMA/VARDHMAN/AVLITE |
| 14 | Supply, fixing and testing in replacement of runway edge lighting bipin type holder of capacity 200W, 6.6 Amp, conforming to ICAO Anns 14, complete all as specified and directed by Engr-in-Charge. Make : AMA/VARDHMAN/AVLITE |
| 15 | Supply, fixing and testing in replacement of taxiway edge lighting bipin type holder of capacity 45W, 6.6 Amp, conforming to ICAO Anns 14, complete all as specified and directed by Engr-in-Charge. Make :AMA/VARDHMAN/AVLITE |
| 16 | Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cables including getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 17 | Returning, filling in, including spreading, levelling, and well ramming, in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 18 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 19 | Sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after laying and streching the cable, complete all as specified and directed by Engr-in-Charge.Note :- For payment purpose punned thickness shall be measured. |
| 20 | Sub class ‘B\" brick, old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed by Engr-in-Charge. |
| 21 | Supply and fixing in replacement of ESNA connector male female 6/16 sqmm cablecomplete all as specified and directed by Engr-in-Charge. Make : AMA/VARDHMAN/AVLITE |
| 22 | M&L PCC 1:3:6 type C 1 using 20 mm graded stone aggregate for repair of base of runway/ taxiway light fitting complete all as directed and specified by Engr-in-Cgarge |
| 23 | Supply and fixing in replacement of iron cage for runway/ taxiway/End lights fitting with dia of cage 40 CM, Height 45 cm made by flat MS iron strip 50mm and iron mess wire 16 gauge with required nut and bolts and one coat of reflexible primer and two coat of emulsion paintcomplete all as specified and directed by Engr-in-Charge |
| 24 | Supply, installation, commissioning and testing in replacement of bi-directional elevated type high intensity threshold cum Runway End Lights Complete withinner GreenAnd redfitting suitable for use with 200W, 6.6Amp AC constant current series system with bi-pin halogen Lamp complete with all accessories such as CI base plate, breakable coupling, mounting assembly, gasket, lamp Holder,lenses, 2 pin secondary lead plug 2.5 Sqmm copper, stainless steel bolt, spring suitable for connection of adequate length etc confirming to ICAO Anns 14, complete all as specified and directed by Engr-in-Charge.Make : AMA/VARDHMAN/AVLITE |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender