Cleaning Of Sewage Line, Septic Tanks, Repair To Drain, Fencing, Security Wall And Other Misc Works Cleaning Of Sewage Line, Septic Tanks, Repair To Drain, Fencing, Security Wall And Other Misc Works
Tender Overview
Project Description
Cleaning Of Sewage Line, Septic Tanks, Repair To Drain, Fencing, Security Wall And Other Misc Works Cleaning Of Sewage Line, Septic Tanks, Repair To Drain, Fencing, Security Wall And Other Misc Works
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-Dec-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-Dec-2021 |
BOQ
| Sl. No. | Item Description |
| 1 | Removal of blokage/ choke up obstructing the flow of sewage line by rodding with rods wood/ kamathis/ choke remover and making the flow continuous for bore of pipe 150mm complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Removal of blokage/ choke up obstructing the flow of sewage line by rodding with rods wood/ kamathis/ choke remover and making the flow continuous for bore of pipe 100mm complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Removal of blokage/ choke up obstructing the flow of sewage line by rodding with rods wood/ kamathis/ choke remover and making the flow continuous for bore of pipe 200mm complete all as specified and as directed by Engineer-in-Charge. |
| 4 | Desilting of septic tank for 200 users with dewatering including carriage of sludge from tank and disposed to a distance exc 100m and n.exc 500m complete all as specified and as directed by Engineer-in-Charge. |
| 5 | Desilting of septic tank for 150 users with dewatering including carriage of sludge from tank and disposed to a distance exc. 100m and n. exc. 500m complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Desilting of septic tank for 100users with dewatering including carriage of sludge from tank and disposed to a distance exc. 100m and n. exc. 500m complete all as specified and as directed by Engineer-in-Charge. |
| 7 | Desilting of septic tank for 50 users with dewatering including carriage of sludge from tank and disposed to a distance exc 100m and n.exc 500m complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Desilting of manhole up to 1.50m deep and stacking the silt at the distance exc. 100m but not exc. 250m complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Desilting of man hole of depth exc 1.50m and n. exc. 2.50m and stacking the silt at the distance exc. 100m but not exc. 250m complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Removing blockage pipe line rejoining the existing line with new SGSW pipes 150mm bore complete for only 01 pipe piece standard length including necessary PCC packing under and haunching at sides (1:4:8) type D2 etc including earth work complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Removing blockage pipe line rejoining the existing line with new SGSW pipes 100mm bore complete for only 01 pipe piece standard length including necessary PCC packing under and haunching at sides (1:4:8) type D2 etc including earth work complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Cleaning of WC/ EWC and removal of blockage by pumping of waste complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Cleaning of nahani trape 75mm dia and removal of blockage complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Cleaning of gully trape of size 125/ 110mm and removal of blockage complete all as specified and as directed by Engineer-in-Charge. |
| 15 | M&L for excavating and breaking existing SGSW gully trap and fixing of new gully trap 150mm x 150mm complete with PCC (1:4:8) type D2, 100mm thick in foundation and making good to match existing surface complete all as specified and as directed. |
| 16 | Taking down CI pipe including fittings of 100mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Taking down CI pipe including fittings of 75mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 18 | S&F 100mm cast iron sand cast soil waste and vent pipe in any length with or without ears with cement joints complete all as specified and as directed by Engineer-in-Charge. |
| 19 | S&F 75mm cast iron sand cast soil waste and vent pipe in any length with or without ears with cement joints complete all as specified and as directed by Engineer-in-Charge. |
| 20 | S&F 100mm cast iron bends any radius complete all as specified and as directed by Engineer-in-Charge. |
| 21 | S&F 75mm cast iron bends any radius complete all as specified and as directed by Engineer-in-Charge. |
| 22 | S&F 100mm cast iron cowl complete all as specified and as directed by Engineer-in-Charge. |
| 23 | S&F 75mm cast iron cowl complete all as specified and as directed by Engineer-in-Charge. |
| 24 | S&F pre-cast manhole covers of RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregates) with two Nos. of handle of MS round bar 12mm dia and 150mm long for manhole cover slab including placing in position and set in CM (1:6) for 450mm x 750mm x 75mm size of manhole complete all as specified and as directed by Engineer-in-Charge. |
| 25 | All as per Item No. 24 above but for 600mm x 900mm x 100mm size of manhole. |
| 26 | All as per Item No. 24 above but for 300mm x 300mm x 75mm size of manhole. |
| 27 | M&L MS steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. |
| 28 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed. |
| 29 | M&L for providing precast reinforced cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregates) set in cement mortar (1:4) as in cover slabs (for manholes) complete all as specified and as directed.Note:- Reinforcement shall be measured and paid separately. |
| 30 | Excavation in trenches not exc.1.50m wide and not exc. 1.5m deep for laying of sewer pipe and manhole etc. and getting out in soft/ loose soil complete all as specified and as directed. |
| 31 | Demolition and breaking up drain pipe SWG pipe set in cement mortar including hunching and bed concrete for 150mm dia SWG pipe complete all as specified and as directed. |
| 32 | Dismantling of RCC drain pipe 200mm dia bore jointed in cement mortar and taking out of trenches complete all as specified and as directed. |
| 33 | M&L for 150mm bore SWG drain pipe of grade \"A\" laid in trenches and jointed complete all as specified and as directed. |
| 34 | M&L for 200mm dia reinforced concrete pipe NP2, laid and jointed complete with collars, jointed with cement mortar complete all as specified and as directed by Engr-in-Charge. |
| 35 | M&L for beding to drain pipes of 150mm dia including packing under and hunching in PCC (1:3:6) type C2 (using 40mm graded stone aggregates) against the side of SWG/ RCC pipes after they are laid and tested for following dia bore pipe complete all as specified and as directed. |
| 36 | All as per Item No. 35 above but 200mm dia. |
| 37 | Returning filling in soft/ loose soil including spreading, levelling watering and well ramming in layers not exc. 25cm thick complete all as specified and as directed. |
| 38 | Removing excavated materials not exc. 50m and depositing where directed complete all as specified and as directed. |
| 39 | M&L for cutting in to existing manholes for connecting new drain making good to pipes and rendering cutting out existing benching for and forming bracketschannel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 and reforming benching as required for 150mm bore pipe complete all as specified and as directed. |
| 40 | Demolition ofbrick masonary built in cement mortar in any ratio complete all as specified and as directed. |
| 41 | M&L old size brickwork with fly ash, straight or curved on plan exc. 6m mean radius built in CM (1:6) complete all as specified and as directed. |
| 42 | Taking down cement plaster on brick or stone wall or concrete surfaces complete all as specified and as directed by Engr-in-Charge. |
| 43 | M&L for rendering 15mm thick on fair faces of concrete or block masonary CM (1:6) finished even and smooth (without using extra cement) in internal surface of wall complete all as specified and as directed. |
| 44 | All as per Item No. 43 above but 10mm thick CM (1:6) and setting coat 5mm thick CM (1:4) on external surface of wall complete all as specified and as directed.. |
| 45 | All as per Item No. 43 above but 5 mm thick in ceiling surfaces.CM (1:4) complete all as specified and as directed. |
| 46 | M&L for preparation ofnew plastered surface of wall and applying two coats of distemper oil emulsion over a coat of primer over a sufficent coat of wall care putty complete all as specified and as directed. |
| 47 | M&L for preparation of new plastered surface of wall and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed. |
| 48 | M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 49 | M&L for preparation of new surfaces of wall and applying two coats of cement base paint complete all as specified and as directed. |
| 50 | M&L for rendering 10mm thick in fair face of internal surfaces of concrete block masonry in manhole in CM (1:4) complete all as specified and as directed. |
| 51 | M&L for rendering 10mm thick on fair face of concrete block masonry in manholes in C:M (1:6) on external surface complete all as specified and as directed. |
| 52 | Taking down PVC pipe (SWR) 110mm dia bore and connection complete all as specified and as directed. |
| 53 | Taking down PVC pipe (SWR) 75 mm dia bore and connection complete all as specified and as directed. |
| 54 | S&F 75mm dia bore pipe (SWR) single socket in any length rubber joints fixed to wall complete all as specified and as directed. |
| 55 | S&F 110mm dia bore pipe (SWR) single socket in any length rubber joints fixed to wall complete all as specified and as directed. |
| 56 | M&L for 75mm dia of outlet PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 57 | S&F 110mm PVC (SWR) WC connector with lip ring complete all as specified and as directed. |
| 58 | Dismantling of RCC fencing post and struts including taking out embeded portion for post embedded in natural ground making good the disturbed portion to requried shape and size for placing new fencing post including any excavation requried complete all as specified and as directed. |
| 59 | Dismantling of fencing wire mesh of any type complete all as specified and as directed. |
| 60 | M&L cement concrete (1:3:6) type C2 (using 40mm graded stone aggregates) as in post hole complete all as specified and as directed. |
| 61 | Supply only chain link fencing any size or type complete all as specified and as directed. |
| 62 | Fixing only chain link fencing including line wires, any mesh, size and type to any standards, rails straining bolts, etc. including provision of binding wire complete all as specified and as directed. |
| 63 | S&F mild steel section and embedding in concrete, posts or struts in fencing including cutting tops to shape as directed drilling holes notching for wire etc. flat iron fillets (for securing wire mesh) including all necessary drilling, bolting etc and similar work conforming to Fe-410-0 complete all as specified and as directed. |
| 64 | S&F mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed the other each screwed end to be fitted with washers and one hexagonal nut but length of bolt exc. 5cm and n. exc. 10cm long and bolt one side embedded in concrete posts etc complete to fix fencing wire dia of shank 11 to 15mm complete all as specified and as directed. |
| 65 | S&F mild steel bars for straightening/ ties bars for chain link fencing 10mm dia of over, cut to length and tying with MS wire n. exc. 0.6mm complete all as specified and as directed. |
| 66 | Dismantling structural steel work any type and any discription etc. complete all as specified and as directed. |
| 67 | Dismantling of punched type concertina coil any type or size complete all as specified and as directed. |
| 68 | Fixing only galvanized steel punched type concertina coil of loop dia 1050mm (dia of coil when unstreched) fixed to angle post strut with 3.15 mm dia galvanised MS plain wirecomplete all as specified and as directed. |
| 69 | Supply only galvanised steel punched type concertina coil of 1050mm dia (dia of coil when unstretched with Nos. of circles 50, Nos. of clips 230 with weight 15.60 kg/ coil and recommended and average coverage area is 6 RM/ coil) and fixed to angle iron post/ struts with 3.15mm dia GI wire complete all as specified and as directed. |
| 70 | S&F galvanised, 2 strand, steel barbed wire, 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed. Note:- Each line wire shall be measured. |
| 71 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15cm thickness (below or above GL) complete all as specified and as directed. |
| 72 | M&L for precast cement concrete (1:2:4) type B0 (using 12.5mm and below stone aggregate) in kerb stone factory made as approved by GE with plain fair faces including champhering, weathering etc complete with joint to match in CM (1:6) complete all as specified and as directed. |
| 73 | M&L for providing 75mm thick cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed. |
| 74 | M&L for machine pressed precast conctete interlocking paver block any shape and size with grey cement and pigment confirming to IS : 15658-2006 of 60mm thickness M-35 Grade over sand cushion complete all as specified and as directed.Note:- Sand will be measured and paid separately. |
| 75 | M&L for 25mm thick sand filling (sand cushioning) under path for layers interlocking tiles complete all as specified and as directed. |
| 76 | Taking out existing unserviceable plaster, loose unsound weaken cement concrete of any description and in any position from existing surface of RCC roof slab/ RCC facia/ beams/ columns/ RCC chajja, average depth 25mm (approximate 6.5 mtrs height from natural GL) with power driven pneumatic chiesel and removal of debries upto a distence 500 mtrs out side MD land including saw cutting of all edges, making square shoulders of cavaties and roughening of smooth surface, scraping out and removing corrosion and all loose scales, rust etc. from the visible reinforcement and cleaning the steel reinforecement properly providing NIT zink primer, Zink primer on visible reinforcement surface to form a contineous film and preparing the surface to recive concrete of epoxy grouting mortar etc. including providing necessary scaffolding complete all as specified and as directed. |
| 77 | M&L for applying bonding coat of modified styrene butadene emulsion in proportion 1 part (bonding agent) : 1 part (water) : 3 part (OP cement) by volume with the brushes etc. to bind new cement plaster/ polymer modified plaster/ concrete/ screed concrete with oldsurface including removal of loose/ distengrated old concrete/ plaster including preparation of surface etc. complete all as specified and as directed. |
| 78 | M&L for applying 25-35mm average thickness plaster on ceiling slab and chajja projections, facia and beams with polymer modified mortar firtified with SBR in proportion 1 part (cement) : 3 part (sand) by weight of cement with 11 to 15 ltrs water addition, finishing surface to match with existing adjoining surface complete all as specified and as directed. |
| 79 | Taking up or down 15mm dia steel tubing and connection including cleaning for refixing or removal to store complete all as specified and as directed. |
| 80 | All as per Item No. 79 above but 20mm dia. |
| 81 | S&F 15mm dia steel tubing medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and as directed. |
| 82 | All as per Item No. 81 above but 20mm dia. |
| 83 | S&F in repair 75mm dia outlet CI nahani trap plain with S/S grating including jointing with solvent cement complete all as specified and as directed. |
| 84 | S&F in repairs vitreous china wash basin with pedestalflat back size 630mm x 450mm white, excluding taps, waste, chain and plug and chain porcelain stopper but including brackets cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed. |
| 85 | S&F PVC valveless, syphonic action type flushing cistern, 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including bracket, complete all as specified and as directed. |
| 86 | S&F PVC water connection 600mm long to wash basin of 15mm dia including PTMT nuts and washers complete all as specified and as directed by Engineer-in-Charge. |
| 87 | Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 88 | M&L for 15mm thick screed bed or bedding layer of morter for laying floor finishes CM (1:6) complete all as specified and as directed. |
| 89 | M&L for non skid ceramic coloured joint free tiles 7 to 8mm thick (square/ rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 90 | M&L glazed ceramic coloured digitaltiles 450mm x 300mm x 7mm thick in vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat in CM (1:4) 10mm thick etc. complete all as specified and as directed. |
| 91 | S&F in repairs vitreous china wash down water closet pan pedestal pattern, white excluding fixing cistern and flush pipe trap front or back inlet including seat cover of any pattern and health faucet (ABS) with rubit cleaning system 1.25 m long, PVC flexible tube and ABS wall hook complete all as specified and as directed. |
| 92 | S&F in repairs fancy type CP bib taps15mm dia, chromium plated cast copper alloy withhalf turn type capstan heads, screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 93 | S&F in repairs fancy type CP stop/ angular cock 15mm dia cast copper alloy, chromium plated fency type screwed down high pressure with half turn type capstan heads, screwed both end for iron pipe or for unions and fixed complete all as specified and as directed. |
| 94 | S&F in repairs fancy type CP stop valve 15mm dia cast copper alloy, chromium plated fency type with long shank and cup (concealed type) screwed down high pressure with half turn type capstan heads, screwed both end for iron pipe or for unions and fixed complete all as specified and as directed. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender