Public Health Engineering Department-PHED has published Yamuna Nagar Phed No. 1 - Wqms 2021-22 Water Quality Monitoring Surve Supplying Of Ph Meter, Conductivity Meter Tds Meter, Turbidity Meter, Double Distillation Plant, Hot Air Oven, Hygrometer, Thermometer Simple And With Probe, Analytical Balance, . Submission Date for this Tender is 23-11-2021. Water Testing Accessories Tenders in Chhachhrauli Lab Haryana. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | pH meter (with 5 years AMC) (With pH Electrode) pH Range -2.00 to 16.00 pH, Resolution/Accuracy 0.01 pH/± 0.01 pH, ORP Range ± 2000 mV, Resolution/Accuracy 1.1 (± 199.9 mV) / 1 mV (beyond), 1.2 ± 0.2(± 199.9 mV) /± 2 mV (beyond), Temp.range 0.0 to 100.00 C (32.0 to 212.00 F), Resolution/Accuracy 0.1 0 C(0.1 0 F)/±0.3 ºC / ±0.5 ºF (0 to 70 ºC), ATC Yes (0 to 100 0 C), Buffer Options USA: pH 1.68, 4.01, 7.00, 10.01,12.45, NIST pH 1.68, 4.01, 6.86, 9.18 ,12.45, No.of pH Calibration Points 5points, Built-in Electrode Arm Yes, Memory 100data sets, Electrode Included ECFC7252101B,single junction pH electrode. Temp.Probe Included, LCD DISPLAY CUSTOM dual-display LCD(5.6X7.5cm), Power Requirements Included, 100 /240VAC SMPS Power Adapter, with US/UK/EUR/Japan plug ,9V,6W, CENTRE,(Make :- EUTECH, WTW, OAKTON) |
2 | Conductivity meter /TDS METER(with AMC for 5years) (With Electrode) Conductivity Range 0.01 to 200.0 mS/cm, Resolution/Accuracy 0.01 / 0.1 µS ; 1 / 0.01mS / 0.1 mS,±1 % full scale, Resistivity Range 2.000 O to 20.0 MO, Resolution/Accuracy 0.01 / 0.1 O ; 0.001 / 0.1 kO ; 0.01 MO, ±1 % full scale, Salinity Range 0.0 to 80.0 ppt, Resolution/Accuracy 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt, ±1 % full scale, TDS Range 0.050 ppm to 500 ppt (@ TDS factor 1.00), Resolution/Accuracy 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt, Resolution/Accuracy 0.10 C (0.1 0 F); ±0.3 0 C(± 0.5 0 F), Temp. Coefficient Linear & pure ; 0.000 to 10.000 %, Normalization Temperature 15.0 to 30.0 0 C (59.0 to 86.0 0 F), Built-in Electrode Arm Yes, Compensation ATC / MTC, Memory 100 data sets, electrode Included, 2 cell epoxy body Conductivity electrode, K=1.0, Power Requirements Included, 100 /240VAC SMPS Power Adapter , 9V, 6W,(Make :- Eutech, WTW, Hach,Lovibond) |
3 | Turbidity meter (Benchtop)/ (Portable)(with amc for 5 years) Accuracy: ±2% of reading plus 0.01 FNU/NTU from 0 - 1000 FNU/NTU , Certifications: CE, KC, RCM, Communication: USB, Compliance: ISO, Data logging: 2000 total logs, includes reading log, verification log and calibration log, Display: 17.8 mm colour touchscreen, Interface: 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner, Light source: Light-emitting diode (IR LED) at 860 ± 30 nm , Measurement method: Nephelometric, Operating temperature range: 0 - 40 °C, Power requirements (Voltage): 100 - 240 VAC, Range: 0 - 1000 NTU, NTU/FNU: 0 – 1000, Reading modes: Single, continuous, Rapidly Settling Turbidity, signal averaging on or off,Regulatory: Meets ISO 7027, DIN EN 27027, DIN 38404 and NFT 9033, Repeatability: ±1% of reading or 0.01 FNU/NTU, whichever is greater (under reference conditions), Response time: Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average), Sample cell compatibility: Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps, Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used., Sample requirements: 25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F), Source Lamp: LED, Stabilisation time: Immediately, Storage conditions: -20 to 60 °C , Units: FNU and NTU, (Make :- Eutech, WTW, Hach,Lovibond) |
4 | Double Distillation plant All Quartz Double Distillation Unit Demountable Boiler Panel Series, Vertical Model with Distillation Apparatus Power Supply Capacity 2.5 Ltr/hr (Make :- Borosil, Glassco) |
5 | Hot Air Oven (with Calibration certificate from NABL accredited Laboratory) • SIZE:-18X18 X18 / 18x24x18 • Double walled inside Aluminum/Stainless Steel 304 qty. • Outside made of Mild steel and painted in Epoxy Powder Coating. • Insulation of 75rnm by mineral Wool. • Double walled inside Aluminum/Stainless Steel 304 qty. •good stoving enamel with adjustable wire mesh nichol plated trays • Heating Elements are on three sides" bottom LHS & RHS. ribs. • With air ventilators on two sides. • Microprocessed Electronic Digital Controller cum Indicator from few "C above ambient to 300" C ±0.5* C having two windows display SV & PV, auto tuning, timer up 999 mts (selectable) low & high temp. accuracy alarm, cycle, timer with buzzer. • Outside made of Mild steel and painted in Epoxy Powder Coating. • Insulation of 75rnm by mineral wool. • Double walled inside Aluminum/Stainless Steel 304 qty. • Heating Elements are on three sides" bottom LHS & RHS. ribs. • With air ventilators on two sides. •Steel stand should be provided along with tyres on which instrument has to kept . •Traceabilitycalibration certificate of controller should be provided • Instrument should be calibrated from NABL calibration laboratory. Includes AMC for 5 years (Make :- NST,OPTICS TECHNOLOGY, AMBASSADOR) |
6 | Hygrometer (with Calibration certificate from NABL accredited Laboratory) Temp.Range -500C ~ +700C Temp. Measuring Accuracy: ± 10C Temp. Resolution: 0.10C Humidity Meas.Range: 10% RH ~ 99% Humidity Accuracy: ±5% RH Humidity Resolution: 1% (Make :- HTC) |
7 | Thermometersimple and with probe (with Calibration certificate from NABL accredited Laboratory) Digital LCD Thermometer with sensor probe (Make :- LT(Type k), Thomassci, Hanna) |
8 | Analytical Balance (with 5 years AMC) (with Calibration certificate from NABL accredited Laboratory) Analytical Balance Capacity 220 gm Accuracy 0.01 mg with internal calibration Pan Size Ø 90 mm (Make :- Radwag, Mettler Toledo, Sartorius, Shimazhu) |
9 | Calibrated Weights (with Calibration certificate from NABL accredited Laboratory) Standard Weight Box Class F1 capacity 1 mg to 200 gm with NABL Accredited Lab Calibration Certificate (Set of 23 wire weights) (Make :- Radwag, Mettler Toledo, Sartorius, denver, wensar) |
10 | Dessicator 250 mm along with 1 kg silia gel (Qualigen) (Make :- Borosil, Glassco, Thermo) |
11 | Laboratory Refrigerator 400 Ltr. with front door of transparent glass (Make Voltas/ Westron) |
12 | Water Bath (12 Nos. Holes of 3" with multipal lids of different size to cover the holes) |
13 | Burette (50 ml.) (A Grade with calibration certificate from NABL accredited Laboratory |
14 | Volumetric pipette (20 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
15 | Volumetric pipette (10 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
16 | Graduated pipette (10 ml. calibration certificate from NABL accredited Laboratory (Borosil Glass) |
17 | Graduated pipette (5 ml. calibration certificate from NABL accredited Laboratory (Borosil Glass) |
18 | Graduated pipette (2 ml. calibration certificate from NABL accredited Laboratory (Borosil Glass) |
19 | Sodium Chloride 80 gm CRM of Merck Make |
20 | pH Buffer Solution 4.0 CRM NIST Traceable with certificate of Merck Make |
21 | pH Buffer Solution 7.0 CRM NIST Traceable of Merck Make |
22 | pH Buffer Solution 10.00 CRM NIST Traceable of MerckMake |
23 | EDTA LR 100 gm. Merck Make |
24 | Ammonium Buffer Soln. LR 500 ml. Merck Make |
25 | Solorome Black LR 25 gm. Merck Make |
26 | Muroxide LR 25 gm. Merck Make |
27 | Sodium Hydroxide LR 500 gm. Merck Make |
28 | Methyl Orage Indicator 125 ml. Merck Make |
29 | Conc. Sulphuric Acid LR 500 ml. Merck Make |
30 | Barium Chloride LR 500 g. Merck Make |
31 | Volumetric Flask (1000 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
32 | Volumetric Flask (500 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
33 | Volumetric Flask (250 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
34 | Volumetric Flask (100 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
35 | Volumetric Flask (50 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
36 | Measuring Cylinder 100 ml with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
37 | Measuring Cylinder 50 ml with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
38 | Measuring Cylinder 20 ml with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
39 | Measuring Cylinder 10 ml with calibration certificate from NABL accredited Laboratory (Borosil Glass) |
40 | Conical Flask 500 ml B Grade Borosil Glass |
41 | Conical Flask 250 ml B Grade Borosil Glass |
42 | Conical Flask 100 ml A Grade Borosil Glass |
43 | Breaker 500 ml B Grade Borosil Glass |
44 | Breaker 250 ml B Grade Borosil Glass |
45 | Breaker 100 ml B Grade Borosil Glass |
46 | Breaker 50 ml B Grade Borosil Glass |
47 | Cup with round bottom of 150 ml capacity A Grade Borosil Glass (Round Bottom) |
48 | Poly Plastic bottles of 1 Ltr. |
49 | Poly Plastic bottles of 500 ml |
50 | Poly Plastic bottles of 250 ml |
51 | Calcium Corbonate 50 gm CRM of Merck make with certificate |
52 | Sodium Corbonate 80 gm CRM of Merck make with certificate |
53 | Silver Nitrate LR 25 gm Merck make |
54 | Potassium Chromate LR 500 gm Merck make |
55 | Whatman Filter paper 100 Nos. |
56 | Reference Stationary Material : APHA Standard method book with 23rd edition and relevant BIS reference code (Original copy) |
57 | Calcium Caronate 500 gm Merck make LR |
58 | Soldium Caronate 500 gm Merck make LR |
59 | Soldium Chloride 500 gm Merck make LR |
60 | Burrette Stand Ply Plastic Heavy |
61 | Fire Extinguisher (Small Size) |
62 | Eye Showers (Medium Size) Standard make |
63 | Gloves with good quality |
64 | First Aid Box |
65 | Nesslers jar 100 ml with 50 ml mark (borosil) B grade |
66 | Conc. Hydrochloric acid (500 ml) |
67 | Silica Gel (500 gm) |
68 | Funnel 3" (borosil) |
69 | Funnel 4" (borosil) |
70 | Calcium chloride LR 500 gm |
71 | Colours calibration standard (CLR-100-500 ml.) CRM of Sigma-ALORICH Co. |
72 | Turbidity calibration standard 500 NTU CRM 500 ml (Formazin) |
73 | Ammonium ferrous sulphate LR 500 gm Merck Make |
74 | Odour testing bottle 250 ml Borosil |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy