Name Of Work: -Survey, Supply Of Material / Equipment, Erection, Testing And Commissioning For Prov. Sop To Wss Pir Bindli Under Electrical Sub – Division Hpsebl ., Ranital Under Ed , Hpsebl ., Kangra ( Seop-21 / 2021-22 ) . Sl. No. Item Descript, Kangra-Himachal Pradesh

Himachal Pradesh State Electricity Board-HPSEB has published Name Of Work: -Survey, Supply Of Material / Equipment, Erection, Testing And Commissioning For Prov. Sop To Wss Pir Bindli Under Electrical Sub – Division Hpsebl ., Ranital Under Ed , Hpsebl ., Kangra ( Seop-21 / 2021-22 ) . Sl. No. Item Descript. Submission Date for this Tender is 20-11-2021. Earth Moving Machinery Tenders in Kangra Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29873941
Name Of Work: -Survey, Supply Of Material / Equipment, Erection, Testing And Commissioning For Prov. Sop To Wss Pir Bindli Under Electrical Sub – Division Hpsebl ., Ranital Under Ed , Hpsebl ., Kangra ( Seop-21 / 2021-22 ) . Sl. No. Item Descript
Open Tender
Indian
Himachal Pradesh
Kangra
20-11-2021

Tender Details

Name Of Work: -Survey, Supply Of Material / Equipment, Erection, Testing And Commissioning For Prov. Sop To Wss Pir Bindli Under Electrical Sub – Division Hpsebl ., Ranital Under Ed , Hpsebl ., Kangra ( Seop-21 / 2021-22 ) . Sl. No. Item Description 1 Ht Line Of Stage-I 2 Prov. St Pole 9Mtr. Long W / L 200 Kg 3 Prov. Rcc Muff Of 2000 Mm Length 4 Prov. C.I. X-Arm For Go Switch & Do Fuse Unit 2800X100x50mm ( 6 Nos. ) 5 Prov. C.I. X-Arm For Single Pole Structure 1500X100x50mm ( 13 Nos. ) 6 Prov. C.I. X-Arm For Double Pole Structure 2400X100x50mm ( 38 Nos. ) 7 Prov. Ai Knee Bracing Set 2* ( 750*50*50 ) Mm For Single Pole 8 Prov. X-Bracing Setoff Size 2 ( 2700X50x50x6mm ) + ( 1500X50x50mm ) For Double Pole 9 Prov. Disc Insulator Set With Helicallyformed Fitting I.E Dead End Clamp & Ball Cleave Socket 10 Prov. Pin Insulaters 11 Prov. G.O.Switch 400 A 12 Prov. Barbed Wire 13 Prov. D.O.Fuse 14 Prov. Ht Stay Set Complete Fitting 15 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 16 Prov. Coil Earthing Set For Steel Pole I.E Pipe 40 Mm Dia, 3000 Mm Long With Base Plate . 17 Prov. Danger Plate ( 250X200x1.6 Mm ) 18 Prov. M.S. Nuts And Bolts ( Off Sizes ) 19 Prov. Full Clump 20 Prov. Half Clump 21 Prov. Aluminium Paint 22 Prov.Aaa Cond.7 / 4.26 Mm 23 Prov. Gi Wire 8Swg 24 Ht Line Of Stage-Ii 25 Prov. St Pole 9Mtr. Long W / L 200 Kg 26 Prov. Rcc Muff Of 2000 Mm Length 27 Prov. C.I. X-Arm For Go Switch & Do Fuse Unit 2800X100x50mm ( 6 Nos. ) 28 Prov. C.I. X-Arm For Single Pole Structure 1500X100x50mm ( 13 Nos. ) 29 Prov. C.I. X-Arm For Double Pole Structure 2400X100x50mm ( 38 Nos. ) 30 Prov. Ai Knee Bracing Set 2* ( 750*50*50 ) Mm For Single Pole 31 Prov. X-Bracing Setoff Size 2 ( 2700X50x50x6mm ) + ( 1500X50x50mm ) For Double Pole 32 Prov. Disc Insulator Set With Helicallyformed Fitting I.E Dead End Clamp & Ball Cleave Socket 33 Prov. Pin Insulaters 34 Prov. G.O.Switch 400 A 35 Prov. Barbed Wire 36 Prov. D.O.Fuse 37 Prov. Ht Stay Set Complete Fitting 38 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 39 Prov. Coil Earthing Set For Steel Pole I.E Pipe 40 Mm Dia, 3000 Mm Long With Base Plate . 40 Prov. Danger Plate ( 250X200x1.6 Mm ) 41 Prov. M.S. Nuts And Bolts ( Off Sizes ) 42 Prov. Full Clump 43 Prov. Half Clump 44 Prov. Aluminium Paint 45 Prov.Aaa Cond.7 / 4.26 Mm 46 Prov. Gi Wire 8Swg 47 Recond. Of Ht Line 48 Prov. St Pole 9Mtr. Long W / L 200 Kg 49 Prov. Rcc Muff Of 2000 Mm Length 50 Prov. C.I. X-Arm For Go Switch & Do Fuse Unit 2800X100x50mm ( 6 Nos. ) 51 Prov. C.I. X-Arm For Single Pole Structure 1500X100x50mm ( 13 Nos. ) 52 Prov. C.I. X-Arm For Double Pole Structure 2400X100x50mm ( 38 Nos. ) 53 Prov. Ai Knee Bracing Set 2* ( 750*50*50 ) Mm For Single Pole 54 Prov. X-Bracing Setoff Size 2 ( 2700X50x50x6mm ) + ( 1500X50x50mm ) For Double Pole 55 Prov. Disc Insulator Set With Helicallyformed Fitting I.E Deadinf Clamp & Ball Cleave Socket 56 Prov. Pin Insulaters 57 Prov. G.O.Switch 400 A 58 Prov. Barbed Wire 59 Prov. D.O.Fuse 60 Prov. Ht Stay Set Complete Fitting 61 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 62 Prov. Coil Earthing Set For Steel Pole I.E Pipe 40 Mm Dia, 3000 Mm Long With Base Plate . 63 Prov. Danger Plate ( 250X200x1.6 Mm ) 64 Prov. M.S. Nuts And Bolts ( Off Sizes ) 65 Prov. Full Clump 66 Prov. Half Clump 67 Prov. Aluminium Paint 68 Prov.Aaa Cond.7 / 4.26 Mm 69 Prov. Gi Wire 8Swg 70 Prov. Eye Hook Bolt 71 Dismentalment Charges 72 250 Kva S / Stn 73 Prov. 11 / 0.4 Kv, 250 Kva Distribution Transformer 74 Prov. S / T Pole9mtr. W / L200 Kg 75 Prov. Rcc Muff Of 2000 Mm Length 76 Prov. C.I. X-Arm ( 2800X100x50 Mm ) For Transformer Base 77 Prov. C.I ( 460X100x50 Mm ) For Supporting Main Channel Of T / F And Go Switch ( 3Nos. ) 78 Prov. Transformer Belting 79 I ) A.I ( 2800X50x50 Mm ) 80 Ii ) A.I ( 460X35x35 Mm ) 81 Prov. C.I. For Fuse Unit / Ab Switch &Ct / Pt Unit ( 2800X75x40 Mm ) 6 Nos. 82 Prov. A.I X Arm For Lightning Arrestor & Distribution Panel Box ( 3X2800x50x50 Mm ) 83 Prov. G.O.Switch 400 A 84 Prov. D.O.Fuse 85 Prov. Lightning Arrestors 86 Prov. Disc Insulator Fitting 87 Prov. Stay Set Complete 88 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 89 Prov. Aaac 7 / 3.15Mm For Eathing 90 Prov. Pipe Earthing 91 Prov. Lt Distribution Panel Box With Acb ( 630A, 50Ka, 4P, 1No. ) &Sfu ( 100A, 9No.Rewirable ) 92 Prov. Half Clamp ( M.S. Flat 50X6 Mm ) 93 Prov. Full Clamp ( M.S. Flat 50X6 Mm ) 94 Prov. M.S. Nuts And Bolts ( Off Sizes ) 95 Prov. Aluminum Thimble 96 Prov. Aluminum Thimble 97 Prov. Lead-Tin Solder ( 60:40 ) 98 Prov. Solder Flux 99 Prov. Danger Plate 100 Prov. Barbed Wire 101 Prov. Lt Cable Aluminum 305 Core, 185Mm2 102 Prov. Shackle Insulator For Earthing 103 Prov. Ct / Pt Combined Unit With Energy Meter 100 / 5 Amp. 104 Prov. Control Cable ( 12 Core ) . 105 Prov. Aluminium Paint. 106 400 Kva S / Stn 107 Prov. 11 / 0.4 Kv, 400 Kva Distribution Transformer 108 Prov. S / T Pole9mtr. W / L200 Kg 109 Prov. Rcc Muff Of 2000 Mm Length 110 Prov. C.I. X-Arm ( 2800X100x50 Mm ) For Transformer Base 111 Prov. C.I ( 460X100x50 Mm ) For Supporting Main Channel Of T / F And Go Switch ( 3Nos. ) 112 Prov. Transformer Belting 113 I ) A.I ( 2800X50x50 Mm ) 114 Ii ) A.I ( 460X35x35 Mm ) 115 Prov. C.I. For Fuse Unit / Ab Switch &Ct / Pt Unit ( 2800X75x40 Mm ) 6 Nos. 116 Prov. A.I X Arm For Lightning Arrestor & Distribution Panel Box ( 3X2800x50x50 Mm ) 117 Prov. G.O.Switch 400 A 118 Prov. D.O.Fuse 119 Prov. Lightning Arrestors 120 Prov. Disc Insulator Fitting 121 Prov. Stay Set Complete 122 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 123 Prov. Aaac 7 / 3.15Mm For Eathing 124 Prov. Pipe Earthing 125 Prov. Lt Distribution Panel Box With Acb ( 630A, 50Ka, 4P, 1No. ) &Sfu ( 100A, 9No.Rewirable ) 126 Prov. Half Clamp ( M.S. Flat 50X6 Mm ) 127 Prov. Full Clamp ( M.S. Flat 50X6 Mm ) 128 Prov. M.S. Nuts And Bolts ( Off Sizes ) 129 Prov. Aluminum Thimble 130 Prov. Aluminum Thimble 131 Prov. Lead-Tin Solder ( 60:40 ) 132 Prov. Solder Flux 133 Prov. Danger Plate 134 Prov. Barbed Wire 135 Prov. Lt Cable Aluminium 3.5 Core, 400Mm2 Double 136 Prov. Shackle Insulator For Earthing 137 Prov. Ct / Pt Combined Unit With Energy Meter 100 / 5 Amp. 138 Prov. Control Cable ( 12 Core ) . 139 Prov. Aluminium Paint. 140 Prov.Comp Asserises And Periphirial Printer 141 3-Ph. Lt For Stage-I 142 Prov. Steel Poles 9Mtr Long 143 Prov. Muffs Of 1800 Mm Length 144 Prov. C.I. X-Arm ( 600X70x40 ) Mm 145 Prov. Shackle Insulator 146 Prov. D-Iron 147 Prov. X-Arm Clamp 148 Prov. Egg Insulator 149 Prov. Eye Hook Bolt 150 Prov. Lt Stay Set 151 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 152 Prov. Coil Earthing 153 Prov. G.I. Wire 8 Swg For Earthwire. 154 Prov. Nuts And Bolts ( Off Sizes ) . 155 Prov. Aluminium Paint 156 Prov. Pvc Spacer 157 Prov. Cost Of Conductor ( Aaac ) ( Including Cutting & Sagging ) 7 / 3.15Mm2 ( 50Mm2 ) 158 3-Ph. Lt For Stage-Ii 159 Prov. Steel Poles 9Mtr Long 160 Prov. Muffs Of 1800 Mm Length 161 Prov. C.I. X-Arm ( 600X70x40 ) Mm 162 Prov. Shackle Insulator 163 Prov. D-Iron 164 Prov. X-Arm Clamp 165 Prov. Egg Insulator 166 Prov. Eye Hook Bolt 167 Prov. Lt Stay Set 168 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 169 Prov. Coil Earthing 170 Prov. G.I. Wire 8 Swg For Earthwire. 171 Prov. Nuts And Bolts ( Off Sizes ) . 172 Prov. Aluminium Paint 173 Prov. Pvc Spacer 174 Prov. Cost Of Conductor ( Aaac ) ( Including Cutting & Sagging ) 7 / 3.15Mm2 ( 50Mm2 ) 175 Cost Of Plinth And Chain Link Fencing For 250Kva S / Stn. & 400Kva S / Stn. ( 2*115303.38 ) 176 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. 177 P / L Cement Concrete 1 : 5 : 10 ( 1 Cement, 5 Sand, 10 Graded Stone Aggregate 40 Mm Ns ) And Curing Complete In Foundation And Plinth. 178 Providing And Laying Cement Concrete 1:2:4 ( 1 Cement, 2 Sand, 4 Graded Stone Aggregate 20Mm Ns ) And Curing Complete In Plinth And Foundation 179 Centering And Shuttering Including Strutting, Propping Etc And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 180 Providing Mild Steel / Tor Steel Reinforcement For R.C.C. Work Including Bending, Binding And Placing In Position Complete Upto Floor Two Level. 181 P / L R.C.C. 1 : 2 : 4 ( 1 Cement, 2 Sand, 4Graded Stone Aggregate 20 Mm Ns ) And Curing Complete, Excluding Cost Of Form Work And Reinforcement. In Plinth And Foundation 182 Supplying, Filling, Spreading & Leveling Stone Boulders Of Size Range 5 Cm To 20 Cm, In Recharge Pit, In The Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. 183 Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 184 Extra For Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.25 Mm Wide 1.6 Mm Thick Weighing 3.64 Kg Per Sqm For Encasing Of Rolled Steel Sections In Beams, Columns And Grillages, Excluding Cost Of Hangers. 185 Painting ( Two Coats ) Excluding Priming Coat Onnew Steel And Steel Based Surface After And I / C Preparing The Surface By Thoroughly Cleaning, Oil, Grease, Deit And Other Foreign Matter Sand Papering And Stopping With Ready Mixed Paint Other Than White 186 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Fine Sand ) 187 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 188 P / F Oxidised M.S. Sliding Door Bolt Anodized Colour & Shade With Bolts & Nuts Screws Etc. Complete ( 250*16Mm ) 189 P / F Oxidised M.S. Handle With Necessary Screws Etc. Complete ( 125Mm ) 190 Cost Of Wire Crates Stage-I 191 Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. Ordinary Rock. 192 Providing & Making Gabion Structure With Mechanically Woven Double Twisted Hexagonal Shaped Wire Mesh Gabion Boxes As Per Is 16014:2012, Morth Clause 2500, Of Required Size, Mesh Type 10X12 ( D=100 Mm With Tolerance Of ± 2% ) Zinc Coated, Mesh Wire Diameter 3.0 Mm, Mechanically Edged / Selvedged With Partitions At Every 1M Interval And Shall Have Minimum 10 Numbers Of Openings Per Meter Of Mesh Perpendicular To Twist, Tying With Lacing Wire Of Diameter 2.2Mm, Supplied @3% By Weight Of Gabion Boxes, Filled With Boulders With Least Dimension Of 200 Mm, As Per Drawing, All Complete As Per Direction Of Engineer-In-Charge.

Key Value

Document Fees
INR 5900 /-
EMD
INR 134260.0 /-
Tender Value
INR 53.70 Lakhs /-

BOQ Items

Name of Work: -Survey, supply of material/equipment, erection, testing and commissioning for prov. SOP to WSS Pir Bindli Under Electrical Sub – Division HPSEBL ., Ranital under ED , HPSEBL ., Kangra (SEOP-21/2021-22).
Sl. No. Item Description
1HT Line of stage-I
2Prov. ST Pole 9Mtr. Long W/L 200 kg
3Prov. RCC Muff of 2000 mm length
4Prov. C.I. X-Arm for GO switch & DO fuse unit 2800x100x50mm(6 Nos.)
5Prov. C.I. X-Arm for Single Pole Structure 1500x100x50mm(13 Nos.)
6Prov. C.I. X-Arm for Double Pole Structure 2400x100x50mm(38 Nos.)
7Prov. AI Knee Bracing Set 2*(750*50*50) mm for single pole
8Prov. X-Bracing Setoff size 2(2700x50x50x6mm ) + (1500x50x50mm) for double pole
9Prov. Disc insulator set with helicallyformed fitting i.e Dead end Clamp & Ball Cleave Socket
10Prov. Pin Insulaters
11Prov. G.O.Switch 400 A
12Prov. Barbed Wire
13Prov. D.O.Fuse
14Prov. HT Stay Set complete fitting
15Prov. Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set)
16Prov. Coil Earthing set for Steel Pole i.e pipe 40 mm Dia,3000 mm long with Base plate .
17Prov. Danger Plate(250X200X1.6 mm)
18Prov. M.S. Nuts and Bolts (Off Sizes)
19Prov. Full Clump
20Prov. Half Clump
21Prov. Aluminium Paint
22Prov.AAA Cond.7/4.26 mm
23Prov. GI wire 8SWG
24HT Line of stage-II
25Prov. ST Pole 9Mtr. Long W/L 200 kg
26Prov. RCC Muff of 2000 mm length
27Prov. C.I. X-Arm for GO switch & DO fuse unit 2800x100x50mm(6 Nos.)
28Prov. C.I. X-Arm for Single Pole Structure 1500x100x50mm(13 Nos.)
29Prov. C.I. X-Arm for Double Pole Structure 2400x100x50mm(38 Nos.)
30Prov. AI Knee Bracing Set 2*(750*50*50) mm for single pole
31Prov. X-Bracing Setoff size 2(2700x50x50x6mm ) + (1500x50x50mm) for double pole
32Prov. Disc insulator set with helicallyformed fitting i.e Dead end Clamp & Ball Cleave Socket
33Prov. Pin Insulaters
34Prov. G.O.Switch 400 A
35Prov. Barbed Wire
36Prov. D.O.Fuse
37Prov. HT Stay Set complete fitting
38Prov. Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set)
39Prov. Coil Earthing set for Steel Pole i.e pipe 40 mm Dia,3000 mm long with Base plate .
40Prov. Danger Plate(250X200X1.6 mm)
41Prov. M.S. Nuts and Bolts (Off Sizes)
42Prov. Full Clump
43Prov. Half Clump
44Prov. Aluminium Paint
45Prov.AAA Cond.7/4.26 mm
46Prov. GI wire 8SWG
47Recond. of HT Line
48Prov. ST Pole 9Mtr. Long W/L 200 kg
49Prov. RCC Muff of 2000 mm length
50Prov. C.I. X-Arm for GO switch & DO fuse unit 2800x100x50mm(6 Nos.)
51Prov. C.I. X-Arm for Single Pole Structure 1500x100x50mm(13 Nos.)
52Prov. C.I. X-Arm for Double Pole Structure 2400x100x50mm(38 Nos.)
53Prov. AI Knee Bracing Set 2*(750*50*50) mm for single pole
54Prov. X-Bracing Setoff size 2(2700x50x50x6mm ) + (1500x50x50mm) for double pole
55Prov. Disc insulator set with helicallyformed fitting i.e Deadinf Clamp & Ball Cleave Socket
56Prov. Pin Insulaters
57Prov. G.O.Switch 400 A
58Prov. Barbed Wire
59Prov. D.O.Fuse
60Prov. HT Stay Set complete fitting
61Prov. Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set)
62Prov. Coil Earthing set for Steel Pole i.e pipe 40 mm Dia,3000 mm long with Base plate .
63Prov. Danger Plate(250X200X1.6 mm)
64Prov. M.S. Nuts and Bolts (Off Sizes)
65Prov. Full Clump
66Prov. Half Clump
67Prov. Aluminium Paint
68Prov.AAA Cond.7/4.26 mm
69Prov. GI wire 8SWG
70Prov. Eye hook bolt
71Dismentalment Charges
72250 KVA S/Stn
73Prov. 11/0.4 kV,250 KVA Distribution Transformer
74Prov. S/T Pole9Mtr. W/L200 kg
75Prov. RCC Muff of 2000 mm length
76Prov. C.I. X-Arm (2800X100X50 mm) for Transformer base
77Prov. C.I (460X100X50 mm) for supporting Main Channel of T/F and GO Switch (3Nos.)
78Prov. Transformer Belting
79I)A.I (2800X50X50 mm)
80II) A.I (460X35X35 mm)
81Prov. C.I. for Fuse Unit/AB Switch &CT/PT unit(2800X75X40 mm) 6 Nos.
82Prov. A.I X Arm for Lightning Arrestor & distribution panel box (3x2800X50X50 mm)
83Prov. G.O.Switch 400 A
84Prov. D.O.Fuse
85Prov. Lightning Arrestors
86Prov. Disc Insulator Fitting
87Prov. Stay Set complete
88Prov. Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set)
89Prov. AAAC 7/3.15mm for eathing
90Prov. Pipe Earthing
91Prov. LT Distribution Panel Box with ACB(630A,50KA,4P,1No.) &SFU(100A,9No.rewirable)
92Prov. Half Clamp (M.S. Flat 50X6 mm)
93Prov. Full Clamp (M.S. Flat 50X6 mm)
94Prov. M.S. Nuts and Bolts (Off Sizes)
95Prov. aluminum Thimble
96Prov. aluminum Thimble
97Prov. Lead-Tin Solder (60:40)
98Prov. Solder Flux
99Prov. Danger Plate
100Prov. Barbed Wire
101Prov. LT Cable Aluminum 305 core, 185mm2
102Prov. Shackle insulator for earthing
103Prov. CT/PT combined unit with energy meter 100/5 Amp.
104Prov. Control cable(12 core).
105Prov. Aluminium Paint.
106400 KVA S/Stn
107Prov. 11/0.4 kV,400 KVA Distribution Transformer
108Prov. S/T Pole9Mtr. W/L200 kg
109Prov. RCC Muff of 2000 mm length
110Prov. C.I. X-Arm (2800X100X50 mm) for Transformer base
111Prov. C.I (460X100X50 mm) for supporting Main Channel of T/F and GO Switch (3Nos.)
112Prov. Transformer Belting
113I)A.I (2800X50X50 mm)
114II) A.I (460X35X35 mm)
115Prov. C.I. for Fuse Unit/AB Switch &CT/PT unit(2800X75X40 mm) 6 Nos.
116Prov. A.I X Arm for Lightning Arrestor & distribution panel box (3x2800X50X50 mm)
117Prov. G.O.Switch 400 A
118Prov. D.O.Fuse
119Prov. Lightning Arrestors
120Prov. Disc Insulator Fitting
121Prov. Stay Set complete
122Prov. Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set)
123Prov. AAAC 7/3.15mm for eathing
124Prov. Pipe Earthing
125Prov. LT Distribution Panel Box with ACB(630A,50KA,4P,1No.) &SFU(100A,9No.rewirable)
126Prov. Half Clamp (M.S. Flat 50X6 mm)
127Prov. Full Clamp (M.S. Flat 50X6 mm)
128Prov. M.S. Nuts and Bolts (Off Sizes)
129Prov. aluminum Thimble
130Prov. aluminum Thimble
131Prov. Lead-Tin Solder (60:40)
132Prov. Solder Flux
133Prov. Danger Plate
134Prov. Barbed Wire
135Prov. LT Cable Aluminium 3.5 core, 400mm2 double
136Prov. Shackle insulator for earthing
137Prov. CT/PT combined unit with energy meter 100/5 Amp.
138Prov. Control cable(12 core).
139Prov. Aluminium Paint.
140Prov.Comp Asserises and periphirial printer
1413-PH. LT for stage-I
142Prov. Steel Poles 9mtr long
143Prov. Muffs of 1800 mm length
144Prov. C.I. X-arm (600x70x40)mm
145Prov. Shackle Insulator
146Prov. D-Iron
147Prov. X-arm clamp
148Prov. Egg insulator
149Prov. Eye hook bolt
150Prov. LT Stay Set
151Prov. Stay Wire 7/3.15 mm (@ 6.0 kg Per Stay Set)
152Prov. Coil earthing
153Prov. G.I. wire 8 SWG for earthwire.
154Prov. Nuts and Bolts (off Sizes).
155Prov. Aluminium Paint
156Prov. PVC spacer
157Prov. Cost of conductor (AAAC) (including cutting & sagging) 7/3.15mm2 (50mm2)
1583-PH. LT for stage-II
159Prov. Steel Poles 9mtr long
160Prov. Muffs of 1800 mm length
161Prov. C.I. X-arm (600x70x40)mm
162Prov. Shackle Insulator
163Prov. D-Iron
164Prov. X-arm clamp
165Prov. Egg insulator
166Prov. Eye hook bolt
167Prov. LT Stay Set
168Prov. Stay Wire 7/3.15 mm (@ 6.0 kg Per Stay Set)
169Prov. Coil earthing
170Prov. G.I. wire 8 SWG for earthwire.
171Prov. Nuts and Bolts (off Sizes).
172Prov. Aluminium Paint
173Prov. PVC spacer
174Prov. Cost of conductor (AAAC) (including cutting & sagging) 7/3.15mm2 (50mm2)
175Cost of Plinth and Chain Link Fencing for 250KVA S/Stn. & 400KVA S/Stn. (2*115303.38)
176Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
177P/L cement concrete 1 : 5 : 10 ( 1 cement, 5 sand, 10 graded stone aggregate 40 mm NS) and curing complete in foundation and plinth.
178Providing and laying cement concrete 1:2:4( 1 cement, 2 sand, 4 graded stone aggregate 20mm NS) and curing complete in plinth and foundation
179Centering and shuttering including strutting, propping etc and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
180Providing mild steel/Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level.
181P/L R.C.C. 1 : 2 : 4( 1 cement, 2 sand, 4graded stone aggregate 20 mm NS) and curing complete, excluding cost of form work and reinforcement. In plinth and foundation
182Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
183Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
184Extra for providing and fixing expanded metal mesh of size 20x60 mm and strands 3.25 mm wide 1.6 mm thick weighing 3.64 kg per sqm for encasing of rolled steel sections in beams, columns and grillages, excluding cost of hangers.
185Painting (two coats) excluding priming coat onnew steel and steel based surface after and i/c preparing the surface by thoroughly cleaning, oil, grease, deit and other foreign matter sand papering and stopping with ready mixed paint other than white
18615 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
187Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
188P/F oxidised M.S. sliding door bolt anodized colour & shade with bolts & nuts screws etc. complete (250*16mm)
189P/F oxidised M.S. handle with necessary screws etc. complete (125mm)
190Cost of wire Crates Stage-I
191Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary rock.
192Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ± 2%) Zinc coated, Mesh wire diameter 3.0 mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2mm, supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per direction of Engineer-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy