Himachal Pradesh State Electricity Board-HPSEB has published Name Of Work: -Survey, Supply Of Material / Equipment, Erection, Testing And Commissioning For Prov. Sop To Wss Pir Bindli Under Electrical Sub – Division Hpsebl ., Ranital Under Ed , Hpsebl ., Kangra ( Seop-21 / 2021-22 ) . Sl. No. Item Descript. Submission Date for this Tender is 20-11-2021. Earth Moving Machinery Tenders in Kangra Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | HT Line of stage-I |
2 | Prov. ST Pole 9Mtr. Long W/L 200 kg |
3 | Prov. RCC Muff of 2000 mm length |
4 | Prov. C.I. X-Arm for GO switch & DO fuse unit 2800x100x50mm(6 Nos.) |
5 | Prov. C.I. X-Arm for Single Pole Structure 1500x100x50mm(13 Nos.) |
6 | Prov. C.I. X-Arm for Double Pole Structure 2400x100x50mm(38 Nos.) |
7 | Prov. AI Knee Bracing Set 2*(750*50*50) mm for single pole |
8 | Prov. X-Bracing Setoff size 2(2700x50x50x6mm ) + (1500x50x50mm) for double pole |
9 | Prov. Disc insulator set with helicallyformed fitting i.e Dead end Clamp & Ball Cleave Socket |
10 | Prov. Pin Insulaters |
11 | Prov. G.O.Switch 400 A |
12 | Prov. Barbed Wire |
13 | Prov. D.O.Fuse |
14 | Prov. HT Stay Set complete fitting |
15 | Prov. Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set) |
16 | Prov. Coil Earthing set for Steel Pole i.e pipe 40 mm Dia,3000 mm long with Base plate . |
17 | Prov. Danger Plate(250X200X1.6 mm) |
18 | Prov. M.S. Nuts and Bolts (Off Sizes) |
19 | Prov. Full Clump |
20 | Prov. Half Clump |
21 | Prov. Aluminium Paint |
22 | Prov.AAA Cond.7/4.26 mm |
23 | Prov. GI wire 8SWG |
24 | HT Line of stage-II |
25 | Prov. ST Pole 9Mtr. Long W/L 200 kg |
26 | Prov. RCC Muff of 2000 mm length |
27 | Prov. C.I. X-Arm for GO switch & DO fuse unit 2800x100x50mm(6 Nos.) |
28 | Prov. C.I. X-Arm for Single Pole Structure 1500x100x50mm(13 Nos.) |
29 | Prov. C.I. X-Arm for Double Pole Structure 2400x100x50mm(38 Nos.) |
30 | Prov. AI Knee Bracing Set 2*(750*50*50) mm for single pole |
31 | Prov. X-Bracing Setoff size 2(2700x50x50x6mm ) + (1500x50x50mm) for double pole |
32 | Prov. Disc insulator set with helicallyformed fitting i.e Dead end Clamp & Ball Cleave Socket |
33 | Prov. Pin Insulaters |
34 | Prov. G.O.Switch 400 A |
35 | Prov. Barbed Wire |
36 | Prov. D.O.Fuse |
37 | Prov. HT Stay Set complete fitting |
38 | Prov. Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set) |
39 | Prov. Coil Earthing set for Steel Pole i.e pipe 40 mm Dia,3000 mm long with Base plate . |
40 | Prov. Danger Plate(250X200X1.6 mm) |
41 | Prov. M.S. Nuts and Bolts (Off Sizes) |
42 | Prov. Full Clump |
43 | Prov. Half Clump |
44 | Prov. Aluminium Paint |
45 | Prov.AAA Cond.7/4.26 mm |
46 | Prov. GI wire 8SWG |
47 | Recond. of HT Line |
48 | Prov. ST Pole 9Mtr. Long W/L 200 kg |
49 | Prov. RCC Muff of 2000 mm length |
50 | Prov. C.I. X-Arm for GO switch & DO fuse unit 2800x100x50mm(6 Nos.) |
51 | Prov. C.I. X-Arm for Single Pole Structure 1500x100x50mm(13 Nos.) |
52 | Prov. C.I. X-Arm for Double Pole Structure 2400x100x50mm(38 Nos.) |
53 | Prov. AI Knee Bracing Set 2*(750*50*50) mm for single pole |
54 | Prov. X-Bracing Setoff size 2(2700x50x50x6mm ) + (1500x50x50mm) for double pole |
55 | Prov. Disc insulator set with helicallyformed fitting i.e Deadinf Clamp & Ball Cleave Socket |
56 | Prov. Pin Insulaters |
57 | Prov. G.O.Switch 400 A |
58 | Prov. Barbed Wire |
59 | Prov. D.O.Fuse |
60 | Prov. HT Stay Set complete fitting |
61 | Prov. Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set) |
62 | Prov. Coil Earthing set for Steel Pole i.e pipe 40 mm Dia,3000 mm long with Base plate . |
63 | Prov. Danger Plate(250X200X1.6 mm) |
64 | Prov. M.S. Nuts and Bolts (Off Sizes) |
65 | Prov. Full Clump |
66 | Prov. Half Clump |
67 | Prov. Aluminium Paint |
68 | Prov.AAA Cond.7/4.26 mm |
69 | Prov. GI wire 8SWG |
70 | Prov. Eye hook bolt |
71 | Dismentalment Charges |
72 | 250 KVA S/Stn |
73 | Prov. 11/0.4 kV,250 KVA Distribution Transformer |
74 | Prov. S/T Pole9Mtr. W/L200 kg |
75 | Prov. RCC Muff of 2000 mm length |
76 | Prov. C.I. X-Arm (2800X100X50 mm) for Transformer base |
77 | Prov. C.I (460X100X50 mm) for supporting Main Channel of T/F and GO Switch (3Nos.) |
78 | Prov. Transformer Belting |
79 | I)A.I (2800X50X50 mm) |
80 | II) A.I (460X35X35 mm) |
81 | Prov. C.I. for Fuse Unit/AB Switch &CT/PT unit(2800X75X40 mm) 6 Nos. |
82 | Prov. A.I X Arm for Lightning Arrestor & distribution panel box (3x2800X50X50 mm) |
83 | Prov. G.O.Switch 400 A |
84 | Prov. D.O.Fuse |
85 | Prov. Lightning Arrestors |
86 | Prov. Disc Insulator Fitting |
87 | Prov. Stay Set complete |
88 | Prov. Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set) |
89 | Prov. AAAC 7/3.15mm for eathing |
90 | Prov. Pipe Earthing |
91 | Prov. LT Distribution Panel Box with ACB(630A,50KA,4P,1No.) &SFU(100A,9No.rewirable) |
92 | Prov. Half Clamp (M.S. Flat 50X6 mm) |
93 | Prov. Full Clamp (M.S. Flat 50X6 mm) |
94 | Prov. M.S. Nuts and Bolts (Off Sizes) |
95 | Prov. aluminum Thimble |
96 | Prov. aluminum Thimble |
97 | Prov. Lead-Tin Solder (60:40) |
98 | Prov. Solder Flux |
99 | Prov. Danger Plate |
100 | Prov. Barbed Wire |
101 | Prov. LT Cable Aluminum 305 core, 185mm2 |
102 | Prov. Shackle insulator for earthing |
103 | Prov. CT/PT combined unit with energy meter 100/5 Amp. |
104 | Prov. Control cable(12 core). |
105 | Prov. Aluminium Paint. |
106 | 400 KVA S/Stn |
107 | Prov. 11/0.4 kV,400 KVA Distribution Transformer |
108 | Prov. S/T Pole9Mtr. W/L200 kg |
109 | Prov. RCC Muff of 2000 mm length |
110 | Prov. C.I. X-Arm (2800X100X50 mm) for Transformer base |
111 | Prov. C.I (460X100X50 mm) for supporting Main Channel of T/F and GO Switch (3Nos.) |
112 | Prov. Transformer Belting |
113 | I)A.I (2800X50X50 mm) |
114 | II) A.I (460X35X35 mm) |
115 | Prov. C.I. for Fuse Unit/AB Switch &CT/PT unit(2800X75X40 mm) 6 Nos. |
116 | Prov. A.I X Arm for Lightning Arrestor & distribution panel box (3x2800X50X50 mm) |
117 | Prov. G.O.Switch 400 A |
118 | Prov. D.O.Fuse |
119 | Prov. Lightning Arrestors |
120 | Prov. Disc Insulator Fitting |
121 | Prov. Stay Set complete |
122 | Prov. Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set) |
123 | Prov. AAAC 7/3.15mm for eathing |
124 | Prov. Pipe Earthing |
125 | Prov. LT Distribution Panel Box with ACB(630A,50KA,4P,1No.) &SFU(100A,9No.rewirable) |
126 | Prov. Half Clamp (M.S. Flat 50X6 mm) |
127 | Prov. Full Clamp (M.S. Flat 50X6 mm) |
128 | Prov. M.S. Nuts and Bolts (Off Sizes) |
129 | Prov. aluminum Thimble |
130 | Prov. aluminum Thimble |
131 | Prov. Lead-Tin Solder (60:40) |
132 | Prov. Solder Flux |
133 | Prov. Danger Plate |
134 | Prov. Barbed Wire |
135 | Prov. LT Cable Aluminium 3.5 core, 400mm2 double |
136 | Prov. Shackle insulator for earthing |
137 | Prov. CT/PT combined unit with energy meter 100/5 Amp. |
138 | Prov. Control cable(12 core). |
139 | Prov. Aluminium Paint. |
140 | Prov.Comp Asserises and periphirial printer |
141 | 3-PH. LT for stage-I |
142 | Prov. Steel Poles 9mtr long |
143 | Prov. Muffs of 1800 mm length |
144 | Prov. C.I. X-arm (600x70x40)mm |
145 | Prov. Shackle Insulator |
146 | Prov. D-Iron |
147 | Prov. X-arm clamp |
148 | Prov. Egg insulator |
149 | Prov. Eye hook bolt |
150 | Prov. LT Stay Set |
151 | Prov. Stay Wire 7/3.15 mm (@ 6.0 kg Per Stay Set) |
152 | Prov. Coil earthing |
153 | Prov. G.I. wire 8 SWG for earthwire. |
154 | Prov. Nuts and Bolts (off Sizes). |
155 | Prov. Aluminium Paint |
156 | Prov. PVC spacer |
157 | Prov. Cost of conductor (AAAC) (including cutting & sagging) 7/3.15mm2 (50mm2) |
158 | 3-PH. LT for stage-II |
159 | Prov. Steel Poles 9mtr long |
160 | Prov. Muffs of 1800 mm length |
161 | Prov. C.I. X-arm (600x70x40)mm |
162 | Prov. Shackle Insulator |
163 | Prov. D-Iron |
164 | Prov. X-arm clamp |
165 | Prov. Egg insulator |
166 | Prov. Eye hook bolt |
167 | Prov. LT Stay Set |
168 | Prov. Stay Wire 7/3.15 mm (@ 6.0 kg Per Stay Set) |
169 | Prov. Coil earthing |
170 | Prov. G.I. wire 8 SWG for earthwire. |
171 | Prov. Nuts and Bolts (off Sizes). |
172 | Prov. Aluminium Paint |
173 | Prov. PVC spacer |
174 | Prov. Cost of conductor (AAAC) (including cutting & sagging) 7/3.15mm2 (50mm2) |
175 | Cost of Plinth and Chain Link Fencing for 250KVA S/Stn. & 400KVA S/Stn. (2*115303.38) |
176 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
177 | P/L cement concrete 1 : 5 : 10 ( 1 cement, 5 sand, 10 graded stone aggregate 40 mm NS) and curing complete in foundation and plinth. |
178 | Providing and laying cement concrete 1:2:4( 1 cement, 2 sand, 4 graded stone aggregate 20mm NS) and curing complete in plinth and foundation |
179 | Centering and shuttering including strutting, propping etc and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
180 | Providing mild steel/Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level. |
181 | P/L R.C.C. 1 : 2 : 4( 1 cement, 2 sand, 4graded stone aggregate 20 mm NS) and curing complete, excluding cost of form work and reinforcement. In plinth and foundation |
182 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
183 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
184 | Extra for providing and fixing expanded metal mesh of size 20x60 mm and strands 3.25 mm wide 1.6 mm thick weighing 3.64 kg per sqm for encasing of rolled steel sections in beams, columns and grillages, excluding cost of hangers. |
185 | Painting (two coats) excluding priming coat onnew steel and steel based surface after and i/c preparing the surface by thoroughly cleaning, oil, grease, deit and other foreign matter sand papering and stopping with ready mixed paint other than white |
186 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) |
187 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
188 | P/F oxidised M.S. sliding door bolt anodized colour & shade with bolts & nuts screws etc. complete (250*16mm) |
189 | P/F oxidised M.S. handle with necessary screws etc. complete (125mm) |
190 | Cost of wire Crates Stage-I |
191 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary rock. |
192 | Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ± 2%) Zinc coated, Mesh wire diameter 3.0 mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2mm, supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per direction of Engineer-in-charge. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy