| 1 | Dismantling fencing wire mesh,any type complete all as specified and as directed by Engineer-in-charge. |
| 2 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded in concrete , brick work , masonry etc portion and making good disturbed area complete all as specified and as directed. |
| 3 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings etc complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description complete all as specified and as directed. |
| 5 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 6 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed. |
| 7 | Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and not exceeding 10 sqm on plan for foundation, etc. and getting out in hard/dense soil complete all as specified and as directed. |
| 8 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard/dense soil complete all as specified and as directed. |
| 9 | M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 10 | M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 11 | M&L for laterite stone walling of regular coursed , well bonded bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge. |
| 12 | M&L for damp proof courses in cement concrete 1:2:4 type B0 40mm thick to horizontal surfaces including necessary formwork complete all as specified and as directed. |
| 13 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm complete all as specified and as directed. |
| 14 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 15 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 16 | M&L for hard core of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 17 | M&L for PCC 1:4:8 type D-2 (40mm graded aggregate) in sub base of flooring 100mm thick complete all as specified and as directed. |
| 18 | M&L for PCC 1:2:4 type B1(20mm graded aggregate) in sub base of flooring 40 mm thick complete all as specified and as directed. |
| 19 | M&L for PCC 1:2:4 type B1(20mm graded aggregate) in sub base of flooring 100 mm thick making impressions while concrete is green complete all as specified and as directed. |
| 20 | M&L for plastic dividing strips 1.5mm thick and width of strip 38mm complete all as specified and as directed. |
| 21 | M&L for bitumen filling in joints of plinth protection and hard standing complete all as specified and as directed. |
| 22 | M&L for rendering 15mm thick on stone masonry surfaces in cement mortar 1:4 and finish the surface even and smooth complete all as specified and as directed. |
| 23 | M&L for rendering 10 mm thick on stone masonry surfaces in cement mortar 1:6 and finish the surface even and smooth(without using extra cement) complete all as specified and as directed. |
| 24 | Supply only integral water proofing compound complete all as specified and as directed. |
| 25 | M&L for cement concrete 1:3:6 type C-2,75mm thick for plinth protection and finished even and smooth without using extra cement complete all as specified and as directed. |
| 26 | M&L for formwork to rough finished flat surfaces of concrete to sides of lintels, cantilevers, shelves including supports, overhanges etc. also splays between floors ans beams etc complete all as specified and as directed. |
| 27 | M&L for reinforced cement concrete 1:2:4 type B1, for beams, cantilevers, lintels over 1.5m span complete all as specified and as directed. |
| 28 | S&F Mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 29 | S&F Mild steel TMT bars 8mm dia stirrups, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 30 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed. |
| 31 | M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 32 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed. |
| 33 | Supply only of river sand as cushion above PCC flooring complete all as specified and as directed. |
| 34 | S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 35 | S&F PVC coated chain link fencing ( mesh 50 mm X 50 mm size) nominal dia of wire 3 mm ( including pvc coating ) fixed to fencing posts using suitable bolts and nuts (nuts and bolts shall be measured seperately) complete all as specified and as directed. |
| 36 | S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete - Fe 410 -W (Gde-E-250) quality-B complete all as specified and as directed. |
| 37 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new /old surfaces complete all as specified and as directed. |
| 38 | M&L for applying of two coat of OBD emulsion over a coat of primer on newly plastered surface including preperation complete all as specified and as directed. |
| 39 | M&L for applying of one coat of OBD emulsion over old painted surface including preperation complete all as specified and as directed. |
| 40 | M&L for preparation of old steel surfaces of any description over 10 cm in width or girth and painting withtwo coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 41 | M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 42 | Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and as directed. |
| 43 | M&L for Sand filling 50 mm thick under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 44 | S&F Polythene film, black, 250 micron laid in floors below flexural concrete complete all as specified and as directed. |
| 45 | M&L for cement concrete work in pavement/ hard-standing of flexural strength 40kg/per square centimetre in field using 400 kg of cement per cubic metre complete all as specified and as directed. Note:- Thickness of concrete 15 cm. |
| 46 | M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ - Thickness of concrete slab - 150mm complete all as specified and as directed. |
| 47 | M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound - Grade \"A\" complete all as specified and as directed. |
| 48 | Finishing surface of concrete roads, pavements, by brooming complete all as specified and as directed. |
| 49 | M&L for Pre-cast cement concrete block masonry with solid blocks,type C1, 1:3:6 using 20 mm graded aggregateexc. 10 cm in width and setting in mortar 1:6, complete all as specified and as directed. |
| 50 | M&L for cement concrete 1:2:4 type B1 (20mm graded aggregate) as in coping complete all as specified and as directed. |
| 51 | M&L for precast cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) in landings, preforated cover slabs (for man holes, drain etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and as directed. |
| 52 | M&L for rendering 15 mm thick in CM 1:4 onfair face of brickwork /concrete surfacesfinished even and smooth without using extra cement complete all as specified and as directed. |
| 53 | M&L for Rolled mild steel in Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. - S & F - Fe 410 -W (Gde-E-250) quality-B complete all as specified and as directed. |
| 54 | Removing excavated material (soil) exc. 1.5 km m but n exc.5.0 km and depositing where directed complete all as specified and as directed. |
| 55 | S&F stainless steel 15 mm grab bar vertical swing horizontal for support near EWC fixed to mwall with necessary fixingarrangement complete all as specified and as directed. |
| 56 | S&F stainless steel 15 mm grab bar left 90° and right 90° fixed to mwall with necessary fixing arrangement complete all as specified and as directed. |
| 57 | S&F stainless steel 15 mm grab bar 842 mm long fixed to mwall with necessary fixing arrangement complete all as specified and as directed. |
| 58 | S&F plastic seat cover (colour) closed pattern with flat bottom suitable for EWC with fixing arrangement (disabled student)including taking down old cover complete all as specified and as directed. |
| 59 | M&L for Point wiring complete as specified with 1100 volt grade confirming to IS 694, 1.5sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor drawn through and including instove enamild steel conduitof suitable size but not less than 20mm dia , with all fittings, fixed on wall/ceiling /floor includingfixing of rotary switches and duly earthed with same cable as for point wiring above but green in colour as continuous earthing wire complete all as specified & directed by Engineer-in-Charge.(a) One light/ point controlled by one rotary switchNote:-(i) Necessary instove enamelled steel conduit junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work withdummy plates shall deemed to be included in the quoted rate.(ii) Same size wire shall be used for phase, neutral & earth conductor.(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. |
| 60 | Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply and Fix LED tube light fitting 1 x16W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, recommeded for Gas / vapour group of IIA & IIB and zone 1&2 IP 65protectedetc. complete with all accessories prewired and including connecting up withthree core 1.5Sqmm FRLS copper coductor complete all as specifed and directed by Engineer-in-Charge. |
| 62 | Supply and fixing Sheet steel enclosure MCB DB SPN - 4 ways with 200 A rated bus bar & neutral link complete all as specified and directed by Engineer-in-Charge. |
| 63 | Supply and fixing MCB single pole & neutral240 volts, 6-32amps, 10KA , C-Curve complete all as specified and directed by Engineer-in-Charge. |
| 64 | Supply and fixing MCB single pole240 volts, 6-32 amps, 10KA, C-Curvecomplete all as sepcifed and directed by Engineer-in-Charge. |
| 65 | S&F Single pointed Air Termination single pointed copper rod 12mm dia and 300mm long including necessary fixing arrangement complete all as specified and as directed. |
| 66 | Supply and fixing Copper Strip25 x 3.15 mm complete with saddle and fixing screw, insulators for roof or down conductor or fixed to pole or any other indicated situation for loop earthing etc, as required including making test point and testing complete all as specified and as directed. |
| 67 | M&L for earthing complete with copper plate electrode 60cmx60cm x3.15mm thick, buried directly in ground (earth pit not less than 2.25 mtrsdeep below ground level) with top edge of the platenot less than 1.5 mtrs below normal ground level,connected tocopper strip 20x3mm as earthing leadby means of bolts, nuts, check nutsand washers of galvanised iron or steel all as shownin electrical plate No 3 in SSR Part -I 2009 connected to eartingtest point all as specified complete withexcavation & earth work, PCC pit with 50mm thickRCC cover (grade M-15) having suitable handle(10mm MS Rod) 20mm dia GI pipe medium gradeISI marked watering pipe with GI funned with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth leadconductorall as specified and as directed and testing on completion. |
| 68 | Supply and fixing of epoxy insulators including all accessories and fixing to the lightening conductors alongwith bolts, nuts, screws etccomplete all as specified and as directed. |
| 69 | M&L for Pipes galvanised \"Medium grade\" ISI marked with all fittings, medium grade, ISI marked,laid in trenches, floor, wall, roof etc and testing commissioning complete of size 40 mm bore complete all as specified and as directed. |
| 70 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75mm x 75 mm x25 mm,drilled and screwed including 03 Nos 8 mm dia 25 mm long hexahonal head screws with suitable enclosure made out of 2 mm thick CRCA sheet complete all as specified and as directed. |
| 71 | Supply andlaying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volt grade with aluminium conductors of size10 sqmm 4core complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply and spreading riddled earth for cushioning and covering of the UG cable in trenches complete all as specified and as directed. |
| 73 | Supply and lay PCC un reinforced cable cover of size 250 mmx150mmx40mm , class LV type I flat for cable protection complete all as specified and directed.Note:- Contractor has to produce PCC cable cover test certificate from the manufacturer. |