Water Proofing For The Extension Library And Auditorium Building Roof At Panjab University Regional Centre, Ludhiana ( Punjab ) . , P.U Campus Sector-14 , Cha-Punjab
TDR : 29854302
Tender Notice
BOQ
Expired
P.U Campus Sector-14 , Cha
Punjab
Water Proofing For The Extension Library And Auditorium Building Roof At Panjab University Regional Centre, Ludhiana ( Punjab ) .
Name of Work: Water proofing for the Extension Library & Auditorium Building roof at Panjab University Regional Centre, Ludhiana (Punjab)
Sl. No.
Item Description
1
Civil work
2
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport(from picking point of dump) including loading, transporting, unloading to approved municipal dumping ground for lead upto 5 km for all lifts, complete as per directions of Engineer-in-charge.( Ref:-1.1.18)
3
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete.( Ref:-11.7)
4
15mm cement plaster on rough side of single or half wall of mix( Ref:-13.2)
5
1:4 (1cement :4fine sand)( Ref:-13.2.1)
6
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.( Ref:-15.56)
7
Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providingaluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre ncluding drilling holes in the receiving surface and providing expandable plastic sleeves in holes etccomplete as per direction of Engineer-in-charge.
8
Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)( Ref:-N.S.)
9
Providing and fixing APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrance, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrance manufacture of density at 25°C, 0.87 - 0.89 kg/ litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/ 5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane.( Ref:-22.19)
10
3mm ( Ref:-22.19.1)
11
Removing/ dismantling of existing tarfelt sheet up to any thickness(up to two layers) including joints and overlaps alongwith layer of primer from the roof or any other surface as per site and its disposal from the roof to the ground level. Complete in all respects to trhe entire satisfaction of the engineer in-charge. ( Ref:-N.S.)