| 1 | Bancho-II, Sarala, Bareswar, Samana-II, Temala, Sasanga-V, Anra, Dhaipokhari & Dimiria-II TW LIPs |
| 2 | Earth work excavation in foundation & plinth in hard soil within 50 mtr. Initial lead and 1.5Mtr initial lift includingdressing and leveling the bed & depositing the soil with initial lead & lift as per direction of engineer-in-charge |
| 3 | Filling in foundation and plinth with sand watered and rammed |
| 4 | Removal of old Cement Plaster from walls including racking out mortar joints |
| 5 | Dismantling & removing 2.5 cm thick AS flooring including disposing of the debrises |
| 6 | Cement concrete (1:4:8) with 4cm size h.g. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. |
| 7 | Cement concrete(1:2:4) with 12mm size black h.g hand broken chips of approved quality from approved quarry for RCCwork including hoisting & laying with ramming watering and curring etc. Complete including cost,taxes, royalty conveyance charge of all material to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-in-charge. |
| 8 | 1st class K.B. brick masonary in cement mortar (1:6) in F&P. |
| 9 | 1st class K.B. brick masonary in cement mortar (1:6) in superstructure. |
| 10 | 12 mm thick cement plastering in cm (1:6) in F & P over brick work. |
| 11 | Cement punning over plastering |
| 12 | Supplying,fitting,placing uncoated HY. Sd. Bars reinforcement etc. complete for RCC work including cutting bending,binding tying the grills, placing in position including cost of binding wire. |
| 13 | Rigid & smooth centering and shuttering including cost carriage of all materials ( for distribution tank/ Plinth band ). |
| 14 | Rigid & smooth centering and shuttering including cost carriage of all materials ( for lintel slab). |
| 15 | Rigid & smooth centering and shuttering including cost carriage of all materials ( for chajja & roof slab). |
| 16 | 2.5 cm thick A.S. flooring with cement concrete (1:2:4) including punning using 12 mm hg chips. |
| 17 | Whitewashing twocoatswith shell lime |
| 18 | Colour washing two coats with shell lime |
| 19 | Painting two coats with any approved paint including cost of paint over iron work. |
| 20 | Filling F & P with excavated materials, moorum including watering and ramming |
| 21 | Laying and fitting of 160 mm dia PVC Pipe including cost of Solvent Cement |
| 22 | Supplying ofMS iron door with iron choukath(0.9x2.00)m 16 gauge |
| 23 | Supplying of unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.4 to 1.46 gms/cc of straight length of 6 (six) meters for portable water supplies confirming to IS-4985/2000 of BIS- Amendment-2 read with Table-1 of IS-Specification bearing ISI mark for working pressure and 160 mm dia CI-I UPVC Pipe to withstand pressure of 2.5 kgf/sq.cm. as per the latest amendment of IS-4985. It includes the cost of sockets in case of plain ended pipes. The testing report is to be obtained from the CIPET, Bhubaneswarfor necessary approval of authority including transportationand complete as per the direction the Engineer-in-charge. |
| 24 | The 160mm x160mm x 110mm MS outlet Tee made with 1 mtr long 100mm dia m.s. pipe (medium duty) welded with 2 nos of 100mm dia flange in between the 1 mtr 100mm diaMS pipe and 0.25 mtr long 200mm dia MS (medium duty) pipe fitted horizontally with 2 nos 100mm dia MS elbow with water locking arrangement made out of 1 No. of 100mm dia open flange and 1 no 100 mm dia blind flange. |
| 25 | 160x160x160mm dia. PVC equal Tee. |
| 26 | 160mm dia. PVC end cap. |
| 27 | 160mm dia. PVC coupler 4 kgf/sqcm |
| 28 | Supplying & fitting of 80 mm dia normal bore G.I.Pipehaving wall thickness 4.5 mm electrical resistance welded of medium class conforming IS-1239(part-I/2004) with latest amendement,screwed at both ends as per I S-554 socketed at one end and other end protected wih plastic threaded protecter,the socket conforming to IS-1239(part -II/1992) with latest amendement on randum length to 4to 7 mtr.& complete as per direction of engiener-in-charge. |
| 29 | Cost of 80 mm dia G.I.Bend IS No. 1239 ( Part-II/1992) |
| 30 | Cost of 80 mm dia G.I.flange IS No. 6392/1971 |
| 31 | Cost of 80 mm dia G.I.socket IS No. 6392/1972 |
| 32 | Cost of 80 mm dia G.I.nippleS No. 6392/1973 |
| 33 | Cost of 100mmx80 mm dia Reducing Socket |
| 34 | Cost of 80 mm dia MS Clamp |
| 35 | Cost of 80 mm dia C.I. Sluice valve |
| 36 | Cost of Rubber insertion |
| 37 | Cost of Nut bolt |
| 38 | Cost of MS display board including painting & wtitting |
| 39 | 6HP/4.5 KW submersible star rated pump set coupled with totally enclosedsquirrel cage induction motorwithdelivery discharge 700 LPM at 25 mtr head with cable, cable clip,support clamp etc suitable for operation at 415volt +6%-15%, 3 phase ,50 Hz AC power supply and full load current out put 11.7 amps with size of suction and delivery 100mm x 100mm dia with overall efficiency 60-65. The materials of construction is as given below .a)Casing -Stainless steel AISI 304B) Impeller- Bronze grade LTB-2 of IS 318/1981. C) Shaft- Stainlesssteel 12 cr 12 of 1570 (PART-5) . D)Sand guard- Bronze E) Suction strainer- Stainless steel SS AISI 302 F) Cable-3x30x2.5 SQMM. (30 mtr) and the pump sets must be as per IS-8034/2002 of reputed brand (preferably Kirloskar/ Lubi) having wide dealership net work for easy availability of spares and as per the Technical specification enclosed in schedule \"A\". |
| 40 | Cost of Control Pannel Board, 4KVA Capacitor, Main Switch with 10HP ASD Starter & MCB including internal wiring with 4mm2 PVC single core copper wire |
| 41 | 3x10sqmm PVC inuslated (heavy duty) armoured Aluminium Tropader Cable confirming to IS-1154 Part-I/1988 including laying below 0.60 mtr. of the ground and filling the excavated materials including watering and ramming . |
| 42 | Cost of 7/20 PVC wire. |
| 43 | Labour charges for installation of Pumpset along with delivery pipes including cost of all petty mateirals / all electrical installation and energisation including cost of all petty mateirals etc. |
| 44 | Supply of small T&P kit comprising of hand gloves-1 pair,tester-1 no,8 inch cutting plier -1 no, 12 inch sly wrench-1 no, 12 inchScrew driver-1no. , 24/27 & 21/23 De spanner-2nos., 24/27 & 21/23 Ring spanner- 2 Nos. (Taparia) |
| 45 | Cost for Electrical installation and energisation in complete shape |
| 46 | Electrical earthing with 40mm dia medium duty G.I. earthing pipe (of each 3m)with earthing installation including cost of all materials such as No 6 GI wire,G.I.flange, charcoal, salt, souldering lead etc. including transportation as required as per direction of engineer-in-charge. |
| 47 | Construction of 3 phase 11 KV line as per REC standard confirming to RE Rules 1956, with 300 Kg., 9 mtr. Long PSC pole support in 50 mtr. Span., 55 sqmm AAA conductor with double disc arrangement, 11 KV “V”Cross-Arm with required nos. of 11 KV B & S disc insulator and 11 KV Pin-Insulator carping and padding of poles, danger board at each pole anticlimbing device and rubbing (spike) stay set at each bending point and double stay at end point with 18mm GI HT stay concreting of stay with anchor plate etc. Including cost of materials, labour, transportation, inspection and commissioning etc. complete including painting in navy blue colour band with inscription of OLIC in each pole. |
| 48 | Construction & erection of 11/0.416 KV, D.P.mounted Sub-Stations of different capacity confirming to RE Rules,1956 mounted on 2.44 Mtr. Long structure, supported in 300 Kg. 9 Mtr. Long PSC pole, transformer hard channel & top channel made 0f 2.8 Mtr. Long 100x50x6 mm M.S. channel, transformer belting on 2.8 Mtr. long 50 x 50 x 5 mm M.S. Angle(all REC.SPN. Std.F-3) with all accessorieslike 3 pole 11 KV HG Fuse (F-5) & A.B.Switches(F-9) both mounted on 2.8M long 75x40x6 mm M.S. Channel and supported by 1.0 mtr. long 50x50x5 mm M.S. Angle with 3 nos. 11 KV lightening Arrestors and Distribution box , Pipe earthing(F-2), including cost of 50 sqmm 3.5 Core PVC cable carping & padding of Poles, Danger board at each Pole, Anti Climbing Devices & all other necessary fittings i.e. required size Nuts & Bolts, Brackets, Cable sockets etc. including cost of all materials, labour, transportation complete with liasioning for testing, inspection and commissioning including parapet wall fencing.25 KVA - BEE 1 Star rating with BIS Level-II |