Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-11-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-12-2021 |
| 2 | 20-11-2021 | Amendment to tender documents with revision of BOQ | BOQ | 27-11-2021 |
| Sl. No. | Item Description |
| 1 | Note : All unserviceable materials obtained out of demolition/dismantling/taking down (other than those for which credit catered under Schedule of credit) shall be disposed of outside MoD Land. Quoted rates against respective item shall deemed to include for same. |
| 2 | B/R ITEMSDemolition of brick work/ block masonry or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material complete all as specified directed. |
| 3 | Demolition of unreinforced cement concrete in any position not otherwise specifically provided for and removal all rubbish material complete all as specified and directed. |
| 4 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as directed. |
| 5 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in roofs, floors (other than ground floors), beams, staircase, landings, chajjas and similar suspended work complete all as specified and directed. |
| 6 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. |
| 7 | Taking down chowkats with shutters (without taking off shutters from the frames) & removing from site area n.exc 1.5 Sqm each complete all as specified and directed. |
| 8 | Taking down chowkats with shutters (without taking off shutters from the frames) & removing from site area exc 1.5 Sqm & n. exc 4.00 sqm each complete all as specified and directed. |
| 9 | Taking down door shutter of any description & removing from site area not exc. 1 sqm each complete all as specified and directed. |
| 10 | Taking down door shutter of any description & removing from site area exc. 1 sqm & n.exc 2.00 sqm each complete all as specified and directed. |
| 11 | Taking down existing roof treatment including PCC padding over roof, removing complete layer of bitumen under PCC padding, cement mortar& felt cleaning the surface by hacking to receive plaster and removingdemolished material outside MD land complete all as specified and directed. |
| 12 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed. |
| 13 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 14 | Taking down cement or cement lime plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish off the premises, complete all as directed. |
| 15 | Hacking out old broken glass (any thickness size quality or description) from wooden frames or stone concrete or brick surrounds, glazed with putty or fixed with beeds complete all as specified and directed. |
| 16 | Taking up or down steel tubingand connections alongwith bib tap, stop cocks and other fittings including cleaning for refixing or removal complete all as specified and directed :- |
| 17 | 15mm bore. |
| 18 | 20mm bore. |
| 19 | Dismantling water tank of capacity exceeding 250 Ltrs but not exceeding 500 Ltrs and removal from sitecomplete all as specified and directed . |
| 20 | Surface excvation not exceeding 30 cmdeep averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 21 | Excavation in post holes (or similar holes)in soft/loose soil, each n.exc 0.5 cum, getting out, returning, filling in and ramming moorum or broken rubble mixed with moorum in layers n.exc 25cm around foundation concrete as ordered, watering and removing surplus soil to a distance not exceeding 50 m and making good surface, complete all as specified and directed. |
| 22 | M & L for roughening the surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.complete all as specified and directed. |
| 23 | M & L for hard core of broken stone or boulders of gauge n.exc 63 mm, deposited, spread & levelled in layers n.exc 15 cm thick watered & rammed to true surface complete all as specified and directed. |
| 24 | M & L for cutting holes into stone walls built in cement mortar or in cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 exc. half brick but not exc.one brick complete all as directed. |
| 25 | M & L for PCC 1:5:10 type E-2 using 40 mm graded crushed stone aggregate as in foundation, filling under floor, in sunken floors etc complete all as specified and directed. |
| 26 | M & L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 27 | M & L for providing cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops, coved fillets, rounded or chamfered on edges & including form work to concrete surfaces complete all as specified and directed. |
| 28 | M & L for precast cement concrete block masonary with solid block 1:3:6 type C1 (using 20 mm graded agg) exc 10 Cm in width and setting in cement mortar 1:6 complete all as specified. |
| 29 | Supply only integral water proofing liquid complete all as directed. |
| 30 | M & L for second class hard wrought as in scantling framed and fixed complete all as specified and directed. |
| 31 | M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads section area exc 6 Sqcm but n.exc 13 Sqcm complete all as specified and directed. |
| 32 | M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads section area exc 13 Sqcm but n.exc 25 Sqcm complete all as specified and directed. |
| 33 | M & L for second class hardwood weather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps complete all as specified and directed. |
| 34 | M & L for second class hard wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 35 | S & F 35mm thick IInd Class Hard wood, plain framed, panelled door shutters, two panel with lock rail and panel of 9mm B.W.P. marine grade plywood bonded with high quality liquid phenol formaldehyde synthetic resin adhesive conforming to IS-710 or 12mm thick particle board veneered with commercial veneering on both faces (as ordered). The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I). Wood used shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. |
| 36 | S & F 30mm thick glazed and skeleton door shutters open rebated of second class hard wood rail and styles, prepared to receive glass/gauge etc divided into squares, with plain, chamfered or rounded, mitered and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I). Wood used shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.(Note :- S & F Glass/gauge shall be measured and paid for separately) |
| 37 | S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with mild steel square tube, In opening complete all as per specifications and drawings as applicable to item 08095 given in SSR Part – II (2010). |
| 38 | S & F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppy and fixing in the frame at site complete all as per specifications and drawings as applicable to item 08080 given in SSR Part–II. |
| 39 | S & F butt hinges, medium weight, colled rolled mild steel & ISI marked complete all as specified and directed for following sizes:- |
| 40 | 75 mm long. |
| 41 | 100mm long. |
| 42 | S & F 100mm long aluminium anodized barrel tower bolt of extruded section ISI marked complete all as specified and directed. |
| 43 | S & F 150mm long aluminium anodized barrel tower bolt of extruded section ISI marked complete all as specified and directed. |
| 44 | S & F 100mm size extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed. |
| 45 | S & F 150mm size extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed. |
| 46 | S & F 300 mm long aluminium alloy, anodised sliding door bolts, plate type with bolt not less than 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy and fixed complete all asdirected |
| 47 | S & F continuous (Piano) hinges width of flaps (when open) 32mm, MS, bright finish or electro galvanisedcomplete all as specified and directed. |
| 48 | M&L for 100mm size hasp and staple, mild steel safety type, stove enamelled black including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 49 | S & F ball catches with 8mm dia steel ball and brass body and skirting plate including letting in and fixed complete all as specified and directed. |
| 50 | S & F in repair for powder coated mild steel drapery rod of 20 mm inner dia (in lengths as directed) of approved colour with and including decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends fixed with PVC rawl plug and steel screws on walls/beam, complete all as directed. |
| 51 | S & Fstainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as directed. |
| 52 | S & F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing complete con- forming to Fe.290.Gde-E-165 complete all as directed. |
| 53 | S & F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-290 (Gde E-165) complete all as specifed and directed. |
| 54 | S&F mild steel work in tubular trusses, purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161 grade St-240 including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts including rivets or nuts and bolts, providing and fixing cleats, fish plates, gusset plates etc and also for wedging, plumbing, turning up & fixing complete all as specified and directed. |
| 55 | M & L for mild steel workconforming to Fe-290 Gde E-165 as in hold fast of flat iron bands, straps, supports or stays for rain water, ventilating pipes cut to length, bend to shap including bolts if required and wall tie, clamps etc., and including preparing surfaces and treated with tar and sanded with clean sharp sand complete all as specified and directed. |
| 56 | S & F 1.6mm thick mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as speicified and directed. |
| 57 | Supply fabrication and fixing powder coated (Thickness of powder coating not less than 50 micron) anodized aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and directed. |
| 58 | Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.5 Kg/Sqm ,black finish reinforced with non-woven polyester reinforcement matt, with a thermo fusable finish laid over compatible cold emulsion bituminous primer applied at the rate of 0.40 Kg/Sqm bytorching with a propane or a butane gas torch, with a overlap of 75mm on longitudinal direction and 100mm on transverse direction including sealing all as per manufacturer’s instructionscomplete all as directed.Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii)The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv)In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 100 Gms/Sqm. (vi) Above aspects are deemed to be included in quoted rate. |
| 59 | S & F for pre-painted galvalume aluminum zinc coating GI based trapizoidal profile steel sheet 0.50mm thick (overall) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturers instructions complete all as specified and directed. |
| 60 | M & L for 4mm thick asbestos cement plain building boards fixed to timber/steel framework with screws etc complete all as specified and directed. |
| 61 | S & F in repairs 12 mm thick Prelaminated particle, board, exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination and alround covered with 6mm thick teak wood beading/lipping fixed with screwed to timber frame complete all as directed. |
| 62 | S & F in repairs 18/19 mm thick Prelaminated particle, board, exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination and alround covered with 6mm thick teak wood beading/lipping fixed with screwed to timber frame complete all as directed. |
| 63 | S & F 18/19 mm thick Prelaminated particle, board, exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination and alround covered with 6mm thick teak wood beading/lipping fixed with screwed to timber frame complete all as directed. |
| 64 | M & L for 25 mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in levelling coarse of floors, surfaces finished even and fair complete all as specified and directed. |
| 65 | M & L for 50mm thick PCC 1:3:6 , type C-1 using 20 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length.Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed. |
| 66 | M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed. |
| 67 | M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishescomplete all as specified and directed. |
| 68 | M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed. |
| 69 | Dismantling existing stone slab including backing and M & L 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps jambs pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 70 | M & L for 60mm thick PVC moulded precast interlocking paving blocks factory casted using grey cement and pigment, casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, confirming to IS-15658-2006 and of shape haxagon/ triangular/ zigzag/ I-shaped etc. as directed having compressive strength not less than 350 Kg/ Sqcm laid over and including25 to 30mm thick layer of sand cushioning including filling the interstices with & including sandand interstices on edges filled with PCC 1:2:4 type B-1 finished even and smooth without using extra cement complete all as directed. |
| 71 | M & L for rendering 5mm thick in CM 1:3 on concrete surface or on fair faces of brick surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and directed. |
| 72 | M & L for rendering 10mm thick in cement mortar 1:3 on fair faces of brick or concrete surfaces finished even and rough for receiving wall tiles/dado completeall as specified and directed. |
| 73 | M & L for 15mm thick rendering in CM 1:6 on stone masonry surfaces or on other than fair faces of brick masonry surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 74 | M & L for 15mm thick rendering in CM 1:4 on fair faces of brick masonry/concrete surfaces, mixed with water proofing liquid @ 150ml per 50 Kg bag of cement and finished even and smooth without using extra cement complete all as specified and directed.(Note :- Supply only Water Proofing Liquid shall be measured and paid separately) |
| 75 | M & L for glazed ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as on vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed. |
| 76 | M & L for glazed ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as on vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed. |
| 77 | M & L for treating sunken floor surfaces with two coats (one priming coat and one finishing coat) of water proofing chemical PIDIFIN 2K of Dr Fixit (or any other brand approved by GE) all as per Manufacturer\"s instructions complete all as specified and directed. |
| 78 | S & F 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all specified and as directed. |
| 79 | S & F 4mm thick sheet glass frosted on one side and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all specified and as directed. |
| 80 | S & F 5.5mm thick sheet glass frosted on one side and glazing with oil putty in squares exc 0.5 sqm in each pane complete all specified and as directed. |
| 81 | M & L for preparing newly plastered surfaces and applying three coats of white wash on ceiling/soffits of chajjas complete all as specified and directed. |
| 82 | M & L for preparation of newly plastered surfaces of wall and applying twocoatsof oil bound distemper over a coat of alkali resistant primer over a coat of 1mm thick wall care puttycomplete all as directed.(Make : For wall putty- Birla white/Bison wall putty of Berger/Narolac wall putty/Asian paint powder putty /Acro wall guard.) |
| 83 | Material and labour for preparation of newly plastered surfaces of wall, applying two coats of premium acrylic emulsion (Alkali, fungal & dirt resistance) paint having VOC less than 50gm/ltr and UV resistance as per IS 15489:2004 of required shade (Company depot tinted) with silicon additives @ 1.43ltr/10Sqm over one coat of exterior grade acrylic primer complete all as specified and directed.Make-Apex Ultima of Asian, weather shield MAX of ICI/Dulux, weather coat long life of Beger, Acroguard 3X of Acro paint. |
| 84 | M & L for complete removal of existing treatment on walls, chajjas etc including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces, priming plastered and other surfaces with alkali resistant priming paint and applying two coats of cement base paint complete all as specified and directed. |
| 85 | M & L for preparation of old painted wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint of 1st grade quality complete all as specified and directed. |
| 86 | M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint of 1st grade quality complete all as specified anddirected. |
| 87 | M & L for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint of 1st grade quality over and including one coatof pink primer complete all as specified and directed. |
| 88 | M & L for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint of 1st grade quality over and including one coatof pink primer complete all as specified and directed. |
| 89 | M & L for preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of 1st grade quality over and including one coatof red oxide zinc chrome primer complete all as specified anddirected. |
| 90 | M & L for French Polishing on new wooden or wood based surfaces of any description width or girth including cleaning and preparing the new surfacewith two or more coats complete all as specified and directed. |
| 91 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed for following sizes:- |
| 92 | 110mm bore |
| 93 | S & F PVC (SWR) bend of any radius with oval access door complete all as specified for following sizes:- |
| 94 | 110mm bore |
| 95 | S & FPVC (SWR) 110mm branch piece, single (single Y) equal or unequal with oval access door complete all as specified and directed. |
| 96 | S&F steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directedfor following sizes:- |
| 97 | 15mm bore. |
| 98 | 20mm bore. |
| 99 | Fixing only old serviceable steel water tubing, galvanized, medium grade, with all new fittings, fixed to walls and ceiling or in floor complete all as specified and directedfor following sizes:- |
| 100 | 15mm bore. |
| 101 | 20mm bore. |
| 102 | S & F 15mm bore bib tap cast copper alloy fancy type chromium plated long body with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 103 | S& F Pillar tap 15mm dia fancy type with capstan head chromium plated screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nut complete all as specified and directed. |
| 104 | S & F 15mm bore stop valve cast copper alloy chromium plated, fancy type screwed down high pressure long shank and cup concealed type with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. |
| 105 | S & F in repairs PVC connection pipe 15mm dia with PTMT nuts of length 450mm complete all as specified and directed. |
| 106 | S & F in repairs PVC (SWR) floor trap 75mm dia outlet plain with Stainless steel grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as directed. |
| 107 | Demolition existing unserviceable salt-glazed stoneware gully traps of any size including surrounding packing and M & L for PVC(SWR) gully trap 125/110 mm, setting and jointing with solvent cement including provision of 150 mm thick PCC 1:4:8 type D-2 (40 mm graded aggregate ) all round & at bottom of trap complete all as specified and directed. |
| 108 | S & F in repairs 20mm dia, ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 109 | Disconnecting existing PVC/PCC tanks, setting aside (or lowerring if required) for repairs,cleaning and removing all scale and dirt etc using bleaching powder from tanks and from mouths of circulating pipe etc and hoisting if required reconnecting and refixing in position for tanks of capacityexc 250 litres and not exc 500 litres all as specified and directed. |
| 110 | S & F 500 litres capacity rotational moulded HDPE water storage tank tripple layer (Cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. Note : PVC tanks shall be ISI marked and having two layers. |
| 111 | S & F in repairs vitreous china wash basin OVAL type of size 545x400x185mm with 20mm thick granite counter including cutting for and pinning in ends for bracket, and waste fittings 32mm including waste pipe, brass chromium plated with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.Note : Granite stone for counter shall be measured and paid separately under respective item of BOQ. |
| 112 | S & F in repairs vitreous China squatting pan (Orissa pattern) water closet (white) of size 580 mm x 440 mm with integral foot rests, \"P\" or \"S\" trap, including connection to trap, flushing pipe and antisyphonage pipe etc and including provision of PCC (1:5:10) type E-2 lean concrete in filling, making good to floor (excluding flushing cistern and flush pipe etc) complete all as specified and directed. |
| 113 | S&F in repairs, PVC low level cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed. |
| 114 | S & F in repair grating doom 125 mm dia of PTMT (minimum weight 40 gms), complete all as specified and directed. |
| 115 | E/M ITEMSTaking down carefully copper/aluminium point wiring (light, fan, socket or power) complete from existing conduits, from PVC Casing/capping with all fittings, such as switches, ceiling rose, pendants, sockets, lamp holder, fan regulators, sketch/brackets light fittings (except tube light fitting) etc and removal of old material from site (except switches, sockets and fittings to be reused) and making good disturbed surfaces of walls, floors ceiling etc complete all as specified and directed to match with existing surfaces. |
| 116 | Taking down main switch/DB’s including MCB’s with board andfixture of any description and making good disturbed surface of walls etc complete all as directed. |
| 117 | Taking down old tube light fittings/light fittings/security lights any type and removal of old light fittings from site (except light fittings to be reused) and making good disturbed surfaces of walls, ceiling etc complete all as specified and directedto match with existing surfaces. |
| 118 | Taking down the existing unserviceable submain/service connection wiring any size and any description including conduits all as directed. |
| 119 | Taking out old unserviceable LT UG cable of any size laid in trenches, ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe including removal of cable protection cover, GI tubing etc complete all as specified and directed.(Note :- Excavation & earth work, shall be measured and paid for seprately under respective items of the BOQ ) |
| 120 | M & L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H cable drawn through and including PVC rigid non metallic conduit (minimum 20mm bore size) and conduit accessories concealed in walls/ceiling/floors all as per IS,including 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H green colour cable as earth continuity conductor to common earth & connecting to earth dolly for the following :-(Note : The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces. ) |
| 121 | One light point/fan point/bell point controlled by one, one way switch. |
| 122 | One 5 Amps socket outlet/switch socket outlet on independent board. |
| 123 | M & L for point wiring complete for 15 Amps socket outlet on independent board with 4 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H cable drawn through and including PVC rigid non metallic conduit (minimum 20mm bore size) and conduit accessories concealed in walls/ceiling/floors all as per IS,including 4 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H green colour cable as earth continuity conductor to common earth & connecting to earth dolly. Notes : The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces. |
| 124 | M & L for modular metal flush box for the following modules :- |
| 125 | 1/2 Module |
| 126 | 3 Module |
| 127 | 6 Module |
| 128 | M & L for modular white cover plate with frame for the following modules :- |
| 129 | 1 Module |
| 130 | 3 Module |
| 131 | 6 Module |
| 132 | S & F modular switch, 1 way 6A, 240 Volts, 1 module complete all as specified and directed. |
| 133 | S & Fmodular bell push, 1 way 6A, 240 Volts, 1 module complete all as specified and directed. |
| 134 | S & F, modular socket outletfor two and three pin combined, 6 Amp, 240 Volts, 2 Module type complete all as specified & directed. |
| 135 | S & F switch socket combination two-in-one (multipurpose), 6 pin, 5 Amp and 15 Amp, modular type, 240 Volts complete all as specified & directed. |
| 136 | S & F bell Ding-dong type, AC, 230 Volts, single pole complete all as specified & directed. |
| 137 | S & F ceiling rose, three terminal, PVC / poly carbonate isolated body, complete all as specified and directed. |
| 138 | S & F sheet metal enclosure double door DB SPN 4 way, 240 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed. |
| 139 | S & F sheet metal enclosure vertical type double door DB TPN 4 way suitable to accomodate MCCB FP, 415 volts upto 160 Amps rating, protection class IP-54 IK-09 made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted as per IEC 61439-3, with copper bus bar of 250 Amps capacity for each phase, with two neutralbars, two Earth bars and cable ties for cable managementall as specified and as approved by Engineer-in-Charge.{Model/Make : Cat Part No 5077 50 of make Legrand or equivalent model of makes listed in List makes}.(Note: MCCB & MCBs shall be measured and paid separately) |
| 140 | S & F MCB SP6 to 32 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed. |
| 141 | S & F MCB SPN 40 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I, complete, all as specified & directed. |
| 142 | S & F MCCB four pole 160 Amp confirming to IEC 60947-2 & IS – 13947-3thermal magnetic releaseand adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 35 KA at 415 V AC , 50 Hz complete, all as specified & directed. |
| 143 | S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS-H cable 1100 Volt grade with 06 Sqmm copper multistranded conductor drawn through and including PVC conduit 25mm boreconcealed in walls/ceiling/floors including 6 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS-H cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only.(ii) The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces. |
| 144 | S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS-H cable 1100 Volt grade with 10 Sqmm copper multistranded conductor drawn through and including PVC conduit 25mm boreconcealed in walls/ceiling/floors including 10 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS-H cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only.(ii) The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces. |
| 145 | Supply and fix Sky rechargeable touch controlled Table Lamp with brightness control white and chrome, 5 Watt 220 V, 50 Hz with cool temprature 6500K, with all standard fittings etc pre-wired and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed.{Model/Make : Cat Part No 581931 of make Philips or equivalent model of makes listed in List of makes}. |
| 146 | Supply and fix baton integrated LED tube light batten fitting, 18 Watt 230 V, 50 Hz with with all standard fittings etc pre-wired and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed.{Model/Make : Cat Part No BCLSB 18WH for Baton integrated tube light fitting of make Bajaj or equivalent model of makes listed in List of makes}. |
| 147 | Supply and fix LED tube light fitting, baton integrated LED channel 10 Watt 230 V, 50 Hz with with all standard fittings etc pre-wired including LED tube, colour temperature neutral white and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed.{Model/Make : Cat Part No BCLSB 10 NW of make Bajaj or equivalent model of makes listed in List makes}. |
| 148 | Supply and fix pendant, champagne opal glass & chrome finish LED wall lamp complete all as specified and directed. {Model/Make : Cat Part No. KCH-CHR-MB160275541A of make Jaquar or equivalent model of makes listed in List makes}. |
| 149 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for layingunderground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed. |
| 150 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose soil complete all as specified and directed. |
| 151 | Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 152 | Supplying, Fixing/laying,jointing and testing and commissioning, LT under ground cables, 1100 Volts grade, XLPE insulated, armoured heavy duty electric cable with stranded aluminuim conductors, laid in trenches, ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe complete all as specified and directed of following sizes:- |
| 153 | 3.5 core 50 Sqmm |
| 154 | 3.5 core 120 Sqmm Notes :-(a)Excavation & earth work, shall be measured and paid for seprately under respective items of the BOQ against B/R items.(b) GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the BOQ (c)Road cutting involved during excavation for laying of cables etc shall be made good as per existing road.Nothing extra shall be admissible on this account.Quoted rates of the item shall be inclusive of the above provisions. |
| 155 | M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required covercomplete all as specified and directed.Note :- Thickness after punning shall be considered for payment. |
| 156 | M & L for brick protection for UG XLPE cable withsub class \"B\" bricks, old size laid dry and flat abutting each other with gaps between adjacent brick 10mm with width equal to length of brick in trenches across the cable complete all as directed. |
| 157 | S & F 40 mm bore Galvanised steel tubing light grade for protection of under ground cable on poles / walls/under road crossing/laid in trenches etc conforming to IS-1239 complete all as directed. |
| 158 | S & F 80 mm bore Galvanised steel tubing light grade for protection of under ground cable on poles / walls/under road crossing/laid in trenches etc conforming to IS-1239 complete all as directed. |
| 159 | M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 15mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009)drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed.Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate.(ii)The cost of excavation, earth work is included in the quoted rate. |
| 160 | M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized iron strip 32x6mm earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI/CI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009)drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed.Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate.(ii)The cost of excavation, earth work is included in the quoted rate. |
| 161 | M & L in replacement Earth continuity conductor of 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as directed. |
| 162 | M & L in replacement Earth continuity conductor galvanised iron strip 32x6mm buried in ground, to be fixed on porcelain insulator with GI nuts, bolts and washers or any other indicated situation with all accessories complete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy