Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-11-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-12-2021 |
| Sl. No. | Item Description |
| 1 | Servicing of Diesel engine Generating sets 40 KVA to 63 KVA Rating to be carried out as per schedulegiven as under. B - check :- (Every 100 Hrs or 6 months whichever is earlier) (i)Change lubricating oil (ii) change lubricating oil filters (iii)change fuel filters(iv) Change coolant (v)check Engine wiring for damage (vi)Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x) Change fuel water seperator. C - Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii)Steam clean engine (iii)Replace hoses if required (iv) Check turbo charger mounting nuts (v ) Check engine oil heater (vi) clean rediator (vii) Inspect following parts and replace if required (Alternator,starter etc ) (viii) Clean fuel from inside (ix) Change engine oil. Note :(i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) |
| 2 | Servicing of Diesel engine Generating sets 125 KVA Rating to be carried out as per schedulegiven as under. B - check :- (Every 100 Hrs or 6 months whichever is earlier) (i)Change lubricating oil (ii) change lubricating oil filters (iii)change fuel filters(iv) Change coolant (v)check Engine wiring for damage (vi)Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x)Change fuel water seperator. C - Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii)Steam clean engine (iii)Replace hoses if required (iv) Check turbo charger mounting nuts (v ) Check engine oil heater (vi) clean rediator (vii) Inspect following parts and replace if required (Alternator,starter etc ) (viii) Clean fuel from inside (ix) Change engine oil.Note :(i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) |
| 3 | Supply only new air filters cartridge elements with \"O\" ring for 40 to 63 KVA DG set complete all as specified and as directed. Make : Kirlosker/cummins/fleetguard |
| 4 | Supply only new air filters cartridge elements with \"O\" ring for 125 KVA DG set complete all as specified and as directed.Make : Kirlosker/cummins/fleetguard |
| 5 | Supply only fuel oil filter cartridge elements with \"O\" ring for 40 to 63 KVA DG set complete all as specified and as directed. Make : Kirlosker/cummins/fleetguard |
| 6 | Supply only fuel oil filter cartridge elements with \"O\" ring for 125 KVA DG set complete all as specified and as directed. Make : Kirlosker/cummins/fleetguard |
| 7 | Supply only lubricant oil filter cartridge elements with \"O\" ring for 40 to 63 KVA DG set complete all as specified and as directed. Make : Kirlosker/cummins/fleetguard |
| 8 | Supply only lubricant oil filter cartridge elements with \"O\" ring for 125 KVA DG set complete all as specified and as directed. Make : Kirlosker/cummins/fleetguard |
| 9 | Material and labour for engine oil 20 W 40 grade in DG Set complete all as specified and as directed.Make: Castrol/ Servo |
| 10 | Material and labour for coolent of DG Set complete all as specified and as directed by Engr-in-Charge. Make: Castrol/ Servo |
| 11 | Material and labour distilled water for battery complete all as directed. |
| 12 | Supply and fixing V-Belt off sizes Make :- Fenner or equivalent as approved by GE complete all as per site requirement complete all as specified and direceted. |
| 13 | Supply and fixing Oil pressure gauge ISI marked complete all as specified and as directed. |
| 14 | Supply and fixing Oil temparature gauge ISI marked complete all as specified and as directed. |
| 15 | Supply anf fixing Fuel gaugemeter ISI marked operated on 24 V DC complete all as specified and as directed. |
| 16 | Sully and fixing RPM Meter complete all as specified and directed by Engr-in-Charge. |
| 17 | Supply and fixing AVRas per site requirment complete all as specified and directed by Engr-in-Charge. |
| 18 | Dismantling of radiator complete from DG Sets cleaning/scraping of depositing manualy from outside of the radiator, cleaning of all copper tubes of radiator with descaling solution from inside & outside with forged feed method & with water and aircompressor (by using separate chemical pump water pump & compressor) plugging of all leakage in welding, brazing of copper tubes, cleaning of fins and replacement of gaskets etc for thecapacties up to 63 KVA DG sets. |
| 19 | Dismantling of radiator complete from DG Sets cleaning/scraping of depositing manualy from outside of the radiator, cleaning of all copper tubes of radiator with descaling solution from inside & outside with forged feed method & with water and aircompressor (by using separate chemical pump water pump & compressor) plugging of all leakage in welding, brazing of copper tubes, cleaning of fins and replacement of gaskets etc for thecapacties up to 100 KVA DG sets. |
| 20 | Material and Labour for dismantling of Exhaust pipe of silencer, cleaning of silencer to remove carbon deposit inside exhaust and refixing including replacement of worn out rubber gasket packing and nut, bolts complete all as specified and as directed. |
| 21 | Repair and maintenance of alternator of type, with opening the cover cleaning all the parts, removing dust with tightening all the electrical connection, checking the serviceability of automatic voltage regulator and voltage setting, tightening the loose connections, checking and setting the alighment properly cleaning air inlet, opening the terminals boxtop and front cover and tightening the cable leads, checking insulation resistance closing the covers and testing complete all as specified and as directed for theUpto 40 KVA DG set of any make |
| 22 | All as per Srl Item No 21 here-in-before above but capacity 50 KVA to 63 KVA DG set of any make |
| 23 | All as per Srl Item No 21 here-in-before above but capacity 125 KVA DG set of any make |
| 24 | Repair and maintenance of alternator of type, with opening the cover cleaning all the parts, removing dust with tightening all the electrical connection, checking the serviceability of automatic voltage regulator and voltage setting, tightening the loose connections, checking and setting the alighment properly cleaning air inlet, opening the terminals boxtop and front cover and tightening the cable leads, checking insulation resistance closing the covers and testing complete all as specified and as directed for theUpto 63 KVA DG set of any make |
| 25 | All as per Srl Item No 24 here-in-before above but capacity 63 KVA to 100 KVA DG set of any make |
| 26 | Disconnecting the defective/burnt Alternator from the engine and removing it from the base frame and shifting it to the workshop, removing rotor and cutting the field copper winding or armature winding and cleaning the slots complete for rewinding and using super enameled copper wire, varnishing and drying using three coats of insulating varnishing reassembling the motor after repairs/ re-setting complete re-installation at site including transportation from the site to and pro, complete of capacity 25 to 40 KVA DG set of any makeNote - Copper wire required for rewinding shall be measured and paid for separately. |
| 27 | All as per Srl Item No 26 above but 50 to 63 KVA DG set of any make |
| 28 | Disconnecting the defective/burnt Alternator from the engine and removing it from the base frame and shifting it to the workshop, removing rotor and cutting the field copper winding or armature winding and cleaning the slots complete for rewinding and using super enameled copper wire, varnishing and drying using three coats of insulating varnishing reassembling the motor after repairs/ re-setting complete re-installation at site including transportation from the site to and pro, complete of capacity upto 63 KVA DG set of any makeNote - Copper wire required for rewinding shall be measured and paid for separately. |
| 29 | All as per Srl Item No 28 above but 63 to 100 KVA DG set of any make |
| 30 | Super enameled copper wire of any size/gauge, or strips as required for rewinding of alternator complete all as specified. |
| 31 | M&L for repair and maintenance of metal doors (i.e., front and back door) of DG set of capacity from 15 KVA to 63 KVA, incl taking down door to the work shope from site and fixed suitable hinged including welding work if required and painting the same as existing colour and refixing the same on DG set complete and as directed by Engineer-In-Charge. |
| 32 | M&L for repair and maintenance of metal doors (i.e., front and back door) of DG set of capacity from 40 KVA to 63 KVA, incl taking down door to the work shope from site and fixed suitable hinged icl welding work if required and painting the same as existing colour and refixing the same on DG set complete and as directed by Engineer-In-Charge. |
| 33 | Replacement of old unserviceable self starter with new self starter, 12 Volts, DC as per existing model and make of Diesel Generator set of capacity upto 63 KVA. |
| 34 | Replacement of old unserviceable self starter with new self starter, 12 Volts, DC of make as approved by Engr-in-Charge for any make and type of Diesel Generator set of capacity upto 166 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 35 | Supplying and fixing in replacment of compact type battery charger unit suitable for charging battery 24 Volt 180 AH with 2 metre copper leads - 02 nos & brass clamps. Make : Exide/Luminous/Tata green/ Amar raja. complete all as specified and directed. |
| 36 | Taking down U/S battery 12V from the DG Set and supply and install 12 V 180AH maintenance free battery including terminal clamps, copper lead of suitable size/ length, battery stand complete testing and commissioning all as directed by Engr-in-Charge. Make : Exide/Luminous/Tata green/ Amar raja |
| 37 | Taking down U/S battery 12V from the DG Set and supply and install 12 V 130-180AH maintenance free battery including terminal clamps, copper lead of suitable size/ length, battery stand complete testing and commissioning all as directed by Engr-in-Charge. Make : Exide/Luminous/Tata green/ Amar raja |
| 38 | M & L for replacement of battery lead set two suitable for 180 AH capacity 1.5 mtr long 10 Sqmm single core copper wire including GM terminals one end coper lug and other and including 0.5 mtr connecting both end with gun metal terminals. |
| 39 | M&L for Tank calibration including provn of tank level indicator of fibre tube with indication of full tank capacity of showing minimum reading of 0.5 ltrs for DG set upto 100 KVA capacity |
| 40 | M&L for Tank calibration including provn of tank level indicator of fibre tube with indication of full tank capacity of showing minimum reading of 0.5 ltrs for DG set upto 160 KVA capacity |
| 41 | Taking out unserviceable asbestos rope from the exhaust pipe, cleaning the exhaust pipe and supply and wraping new asbestos rope of suitable size and wrapping with wire mesh and plastering with plaster of paris / white cement for smooth finishing including replacment of gasket and tightening of all nut and bolts, all as directed by the Engr-in-Charge. |
| 42 | Repairs to DG Set Engine upto six cylinder of capacity upto 63 KVA by dismantling/strip opening of the DG Set for overhauling by removing the cylinder head assembly including facing and grinding, piston connecting rod, cylinder liner, oil sump and injector including replacement of worn out spare i.e., cylinder liner with \"O\" ring, Piston assembly, connecting rod, large end bearing pair, valve seat, valve guide, FIP element, lubricant oil pump, gasket for cylinder, set of O rings, set of hose pipes, fuel pipes nozzle calibration, FIP caliberation, water pump assembly etc and reassembling the complete engine all as specified and as directed. |
| 43 | Supply and fixing on load changeover switch Range 200A, 415V, 4P, confirming to IEC 60947-3, IS/IEC 60947-3 Conforms to Staggered terminals, Site convertible fuse version for open execution Flip-able handle above 400A Interchangeable dual shaft position with site convertibility along with SS enclosure version require separate cable gland box complete all as specified and directed by Engr-in-Charge. Make :- L&T/Havells/Legrand/Standard/Indo Asian |
| 44 | All as per Srl item No. 43 here-in-before above but of capacity 163 Amp |
| 45 | All as per Srl item No. 43 here-in-before above but of capacity 100 Amp |
| 46 | All as per Srl item No. 43 here-in-before above but of capacity 63 Amp |
| 47 | Repair and overhalling of FIP Nozzle of capacity 15 KVA to 63 KVA |
| 48 | Repair and overhalling of FIP Nozzle of capacity 63 KVA to 100 KVA |
| 49 | S & F of Dynamo with 12 Volts DC of Make Lues, Diesel Generator set of any capacity complete all as specified and directed |
| 50 | Disconnecting input/output supply from voltage stabilizer any type oil/air cooled and dismantling the same for repair checking/testing all components complete repairing for efficient functioning checking/tightening of all connections resetting/reassembling complete all as specified and as directed for Voltage stabilizer of upto 50 KVA capacity. Note :- Cost of PCB control cards, servo motors, voltmeter, relays. Ampere meter, contactor, selector switch, rewinding of stabilizer will be measured and paid separately under relevant item of work under this schedule. |
| 51 | All as per Srl item No-50 here-in-before above but for Voltage stabilizer upto 100 KVA capacity. |
| 52 | All as per Srl item No-50 here-in-before above but for Voltage stabilizer upto 160 KVAcapacity. |
| 53 | All as per Srl item No- 50 here-in-before above but for Voltage stabilizer upto 200 KVAcapacity. |
| 54 | Supply and fixing PCB control cards for output supply of voltage stabilizer of capacity upto 200 KVA all as directed. |
| 55 | Supply and fixing control cards for input supply of voltage stabilizer of capacity upto 200 KVA all as directed. |
| 56 | Supply and fixing control card for high voltage cut off protection reduction of voltage and automatic ON after 10 second time delay all as directed |
| 57 | Supply and fixing servo motor complete including pinion for voltage correction having speed of correction 8 volts per second of capacity upto 10 Kg Torque. (Make :- AE/ PARADISE/ VOLT AMP) |
| 58 | Supply and fixing selector switch of existing capacity suitable for three phase stabilizer all as directed. |
| 59 | Supply and fixing indicator lamps to show RYB phase of 3 phase 415 volt 50 Hz AC supply as replacement of defective indicator lamp in existing panel all as directed. |
| 60 | Material and labour for complete rewiring for power and control circuit of voltage stabilizer using standard copper wire, replacement of thimbles, connectors numbering of wiring to all control and measuring instrument for capacity upto 250 KVA voltage stabilizer. |
| 61 | Material and labour for complete rewiring for power and control circuit of voltage stabilizer using standard copper wire, replacement of thimbles, connectors numbering of wiring to all control and measuring instrument for capacity upto 100 KVA voltage stabilizer. |
| 62 | Supply and fixing Dimmer for servo stabilizer of capacitie upto 100KVA |
| 63 | Supply and fixing Dimmer for servo stabilizer of capacitie upto 160KVA |
| 64 | M&L for filling /toping up of oil in servo voltage stabilizer having dielectric strength upto 40 KVA at 2.5 mm gap high voltage as per IS/IEC specification of low viscosity complete all as specified and as directed. |
| 65 | Supply and fixing in replacement of burnt defective LT copper coil of stabilizer with new one made out of suitable size/gauge of copper super enameled wire of high quality matching with the existing impendence and insulation including testing all as specified and directed by Engr-in-Charge. |
| 66 | Repai/replacementof Digital mother Board of 125 KVA DG set complete with wiring as per existing make and model all as specified and directed by Engr-in-Charge. |
| 67 | Material and labour for disconnecting the filter bed from the indoor unit of AC\"s of various sizes cleaning thefilter beds & copper fins, removal of complete dirtdeposited inside the cooling coil fins area by spary of scale removing agent and flushing out with fresh water till removal of complete dirt from the fins area and flushing out with air bolwer and refixing the same in existing position complete all as specified and directed by the Engineer-in-Charge. |
| 68 | Material & Labour for chemical servicing of the out door unit of following capacitiesby dismantling the sheet metal parts, apply the organic compound of scale remover to the air cooled condenser fins & tube area, and flushing through forced method, till removal the complete scale deposit across the fins & tube and cleaning, fixing the sheet metal parts, fan blades, etc. all specified as directed by Engineer-in-Charge. |
| 69 | Material and labour for taking down unserviceable burnt compressor, Supply and fix scroll type new compressor of existing unit make suitable for 1.5/2 TR air cooled split type unit andrectify the control wiring defects if any, connecting back all controls and refrigerant piping after necessary modification as required for system, pressure testing with nitrogen gas under constant pressure of 300 PSI Kg/sq.cm for minimum 08 hours vacuumising, gas charging, commissioning and checking the performance of the system all as directed by the Engineer-in-Charge. |
| 70 | Material and labour for servicing/cleaning of complete indoor and out door unit of Ducted Split type / Split Type Air conditioner ofWindow Type AC 1.5 TRcapacity by means of adding cleaning solution with water. The cleaning of the condensor and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition and specified and as directed by Engineer-in-Charge. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch \"A\". |
| 71 | Material and labour for servicing/cleaning of complete indoor and out door unit of Ducted Split type / Split Type Air conditioner ofSplit Type AC 1.5 TRcapacity by means of adding cleaning solution with water. The cleaning of the condensor and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition and specified and as directed by Engineer-in-Charge. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch \"A\". |
| 72 | Taking out unserviceable Receprocating type compressor of Split Type AC 1.5 Ton capacity, from site and replacement of compressor against repair of existing make (R Compressor) and re-fixingthe compressor sealed unit in position, charging of refrigerant gas R-22ofrequired quantity, bracing of discharge andsuction line and leak testing complete as directed by the Engineer-in-charge |
| 73 | Taking out unserviceable Rotary type compressor of Split Type AC 1.5 Ton capacity and re-fixingwith new Rotary type compressor sealed unit in position, charging of refrigerant gas R-22ofrequired quantity, bracing of discharge andsuction line and leak testing complete as directed by the Engineer-in-charge |
| 74 | Supply only in replacement of Hard drawn copper pipe size suitable for existing one and connecting with indoor to outdoor unit of AC Plant along insulating rubber sleeves and including brazing complete all as directed. |
| 75 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA |
| 76 | Supply and charging of refrigerant gas M -22/R-134 upto sufficient pressure for compressor of 1.5 ton capacitywindow type /split type ACs including connected works like pressure testing with nitrogen before filling of refrigeratn gas including cutting of copper tubing and brazing and refixing in position complete. |
| 77 | Dismantling old and unsv air swing fan motorand replacing with new one suitable for 1.5/2 ton capacity split AC. |
| 78 | Dismantling oldunserviceable condenser fan motor suitable for 1.5/2 ton capacity window /splittype AC and replacing by new one of existing make and model . . |
| 79 | Supply and replacing old and defectivePCBcardfor indoor unit ofsame model amd make suitable for 1.5/2 TR capacity split type units. |
| 80 | Supply and replacing old/unsv AC remote with new one suitable for 1.5/2 ton capacity split AC of Make LG/Daikin. |
| 81 | Gas charging with R-22a for split type AC in position including leak testing to achieve desired suction pressure and temperature (or any other cooling applainces also) |
| 82 | Supply only Condenser blower motor for window AC 1.5 / 2 TR capacity. |
| 83 | Supply only Fan Blade suitable for 1.5 /2 Ton Split Type Air conditioner |
| 84 | Supply only relay for any type ofAC any capacity and make. |
| 85 | Supply only OLP for any type ofA/C any capacity and make. |
| 86 | Supply only PCB suitable for split /window type A/C 2/1.5 TR of any Make. |
| 87 | Supply only starting capacitor 80/ 100 mfd for airconditioner . |
| 88 | Supply only Running capacitor 45 mfd for Split type Air conditioner 1.5 Ton Capacity |
| 89 | Supply only Running capacitor 36 mfd forair conditioner of any capacity |
| 90 | Supply only PVC air filter for split type A/C ofany capacity and Make . |
| 91 | Supply only contactor suitable for 2/1.5 TR of any make |
| 92 | Supply onlyBrass angle valve 5/8 inch for split AC 1.5/2TR capacity. |
| 93 | Supply onlyBrass angle valve 3/8 inch for split AC 1.5/2TR capacity. |
| 94 | Supply only Copper tubing 5/8\" dia for extending refrigerant piping including brazing/adopter and accessories. |
| 95 | Supply onlyCopper tubing 3/8\" dia for extending refrigerant piping including brazing/adopter and accessories. |
| 96 | Supply onlyPuff insulation to suction pipe of split AC. |
| 97 | Supply onlyblower motor of indoor unit of split AC 1.5/2TR |
| 98 | Supply onlyremote control system of split / window type A/C of capacity 2/1.5 TR . |
| 99 | Supply onlyauto swing motor for inside unit of split A/C of capacity 2/1.5 TR of any make |
| 100 | Servicing of Diesel engine Generating sets 15 KVA to 30 KVA Rating to be carried out as per schedulegiven as under. B - check :- (Every 100 Hrs or 6 months whichever is earlier) (i)Change lubricating oil (ii) change lubricating oil filters (iii)change fuel filters(iv) Change coolant (v)check Engine wiring for damage (vi)Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x) Change fuel water seperator. C - Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii)Steam clean engine (iii)Replace hoses if required (iv) Check turbo charger mounting nuts (v ) Check engine oil heater (vi) clean rediator (vii) Inspect following parts and replace if required (Alternator,starter etc ) (viii) Clean fuel from inside (ix) Change engine oil. Note :(i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) |
| 101 | Servising of Diesel engine Generating sets 15 KVA to 100 KVA Rating to be carried out as per schedulegiven as under. B- check :- (Every 100 Hrs or 6 months whichever is earlier) (i)Change lubricating oil (ii) change lubricating oil filters (iii)change fuel filters(iv) Change coolant (v)check Engine wiring for damage (vi)Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x)Change fuel water seperator. C- Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii)Steam clean engine (iii)Replace hoses if required (iv) Check turbo charger mounting nuts (v )cCheck engine oil heater (vi) clean rediator (vii) Inspect following parts and replace if required (Alternator,starter etc ) (viii)Clean fuel from inside (ix) Change engine oil. Note :(i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) |
| 102 | Supply & relacing new air filters cartridge elements with \"O\" ring for 63 to 100 KVA DG set complete all as specified and as directed. (Make : Kirlosker/cummins/fleetguard) |
| 103 | Supply& relacing fuel oil filter cartridge elements with \"O\" ring for 20 to 100 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 104 | Supply & relacinglubricant oil filter cartridge elements with \"O\" ring for 20 to 100 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 105 | Supply & relacing fuel water separator filters cartridge elements with \"O\" ring for 20 to 100 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 106 | Supply & relacingengine oil 20 W 40 grade in DG Set complete all as specified and as directed. Make: Castrol/ Servo |
| 107 | Supply & relacingCoolant of DG Set complete all as specified and as directed. Make: Castrol/ Servo |
| 108 | Supply & relacingV-Belt off sizes Make :- Fenner or equivalent as approved by GE complete all as per site requirement complete all as specified and direceted. |
| 109 | Supply & relacing Oil pressure gauge ISI marked complete all as specified and as directed. |
| 110 | Supply & relacingOil temparature gauge ISI marked complete all as specified and as directed. |
| 111 | Supply & relacingFuel gaugemeter ISI marked operated on 24 V DC complete all as specified and as directed. |
| 112 | Supply & relacing distilled water for battery complete all as directed. |
| 113 | Servicing of Diesel engine Generating sets 30 KVA to 63 KVA Rating to be carried out as per schedulegiven as under. B - check :- (Every 100 Hrs or 6 months whichever is earlier) (i)Change lubricating oil (ii) change lubricating oil filters (iii)change fuel filters(iv) Change coolant (v)check Engine wiring for damage (vi)Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x)Change fuel water seperator. C - Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii)Steam clean engine (iii)Replace hoses if required (iv) Check turbo charger mounting nuts (v ) Check engine oil heater (vi) clean rediator (vii) Inspect following parts and replace if required (Alternator,starter etc ) (viii) Clean fuel from inside (ix) Change engine oil.Note :(i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) |
| 114 | Supply only new air filters cartridge elements with \"O\" ring for 15 to 25 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 115 | Supply only new air filters cartridge elements with \"O\" ring for 30 to 63 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 116 | Supply only fuel oil filter cartridge elements with \"O\" ring for 15 to 25 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 117 | Supply only fuel oil filter cartridge elements with \"O\" ring for 30 to 63 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 118 | Supply only lubricant oil filter cartridge elements with \"O\" ring for 15 to 25 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 119 | Supply only lubricant oil filter cartridge elements with \"O\" ring for 30 to 63 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 120 | Repair and maintenance of alternator of type, with opening the cover cleaning all the parts, removing dust with tightening all the electrical connection, checking the serviceability of automatic voltage regulator and voltage setting, tightening the loose connections, checking and setting the alighment properly cleaning air inlet, opening the terminals boxtop and front cover and tightening the cable leads, checking insulation resistance closing the covers and testing complete all as specified and as directed for the following capacity of Upto 25 KVA DG set of any make:- |
| 121 | All as per Srl item No 120 here-in-before above but 30 KVA to 63 KVA DG set of any make |
| 122 | Disconnecting the defective/burnt Alternator from the engine and removing it from the base frame and shifting it to the workshop, removing rotor and cutting the field copper winding or armature winding and cleaning the slots complete for rewinding and using super enameled copper wire, varnishing and drying using three coats of insulating varnishing reassembling the motor after repairs/ re-setting complete re-installation at site including transportation from the site to and pro, complete of capacity 15 to 25 KVA DG set of any make Note - Copper wire required for rewinding shall be measured and paid for separately. |
| 123 | All as per Srl item No 122 here-in-before above but 30 to 63 KVA DG set of any make |
| 124 | Supply and fixing on load changeover switch Range 100A, 415V, 4P, confirming to IEC 60947-3, IS/IEC 60947-3 Conforms to Staggered terminals, Site convertible fuse version for open execution Flip-able handle above 400A Interchangeable dual shaft position with site convertibility along with SS enclosure version require separate cable gland box complete all as specified and directed by Engr-in-Charge. Make :- L&T/Havells/Legrand/Standard/Indo Asian |
| 125 | Supply and fixing on load changeover switch Range 160A, 415V, 4P, confirming to IEC 60947-3, IS/IEC 60947-3 Conforms to Staggered terminals, Site convertible fuse version for open execution Flip-able handle above 400A Interchangeable dual shaft position with site convertibility along with SS enclosure version require separate cable gland box complete all as specified and directed by Engr-in-Charge. Make :- L&T/Havells/Legrand/Standard/Indo Asian |
| 126 | All as per item No. 125 here in before but of capacity 100 Amp |
| 127 | All as per item No. 125 here in before but of capacity 63 Amp |
| 128 | Repair and overhalling of FIP Nozzle of capacity 15 KVA to 63 KVA |
| 129 | S & F of Dynamo with 12 Volts DC of make Lues, Diesel Generator set of any capacity complete all as specified and directed |
| 130 | S & F new silencer in repair of 32 KVA DG as per existing size with all connected accessories complete all as specified and directed by Engr-in-Charge. |
| 131 | Supply & laying of UG cable LT 1100 volts grade XLPE insulated armouredheavy duty elect cable with stranded aluminium conductor cross section area 50 Sqmm 3.5 core ISI Marked including taking down,laid in trenches or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. Make: Havells/Gloster/Finolex/Polycab |
| 132 | Disconnecting input/output supply from voltage stabilizer any type oil/air cooled and dismantling the same for repair checking/testing all components complete repairing for efficient functioning checking/tightening of all connections resetting/reassembling complete all as specified and as directed for Voltage stabilizer upto 63 KVA capacity. Note Cost of PCB control cards, servo motors, voltmeter, relays. Ampere meter, contactor, selector switch, rewinding/ dimmer of stabilizer will be measured and paid separately under relevant item of work under this schedule. |
| 133 | All as per srl item No-132 here-in-before but for Voltage stabilizer above 63 KVA to 160 KVA capacity. |
| 134 | Supply and fixing control cards for output supply of voltage stabilizer of capacity upto 160 KVA all as directed. |
| 135 | Supply and fixing control cards for input supply of voltage stabilizer of capacity upto 160 KVA all as directed. |
| 136 | Supply and fixing control card for high voltage cut off protection reduction of voltage and automatic ON after 10 second time delay all as directed |
| 137 | Supply and fixing servo motor complete including pinion for voltage correction having speed of correction 8 volts per second of capacity upto 10 Kg Torque. (Make :- AE/ PARADISE/ VOLT AMP) |
| 138 | Supply and fixing selector switch of existing capacity suitable for three phase stabilizer all as directed. |
| 139 | Supply and fixing indicator lamps to show RYB phase of 3 phase 415 volt 50 Hz AC supply as replacement of defective indicator lamp in existing panel all as directed. |
| 140 | Material and labour for complete rewiring for power and control circuit of voltage stabilizer using standard copper wire, replacement of thimbles, connectors numbering of wiring to all control and measuring instrument for capacity upto 160 KVA voltage stabilizer. |
| 141 | Disconnecting input/output supply from voltage stabilizer any type oil/air cooled and dismantling the same for repair checking/testing all components complete repairing for efficient functioning checking/tightening of all connections resetting/reassembling complete all as specified and as directed for Voltage stabilizer of upto 25 KVA capacity.Note :-Cost of PCB control cards, servo motors, voltmeter, relays. Ampere meter, contactor, selector switch, rewinding/ dimmer of stabilizer will be measured and paid separately under relevant item of work under this schedule. |
| 142 | All as per srl item No-141 here-in-before but for Voltage stabilizer upto 63 KVA capacity. |
| 143 | All as per srl item No-141 here-in-before but for Voltage stabilizer upto 100 KVAcapacity. |
| 144 | All as per srl item No-141 here-in-before but for Voltage stabilizer upto 250 KVAcapacity. |
| 145 | Supply and fixing control cards for output supply of voltage stabilizer of capacity upto 250 KVA all as directed. |
| 146 | Supply and fixing control cards for input supply of voltage stabilizer of capacity upto 250 KVA all as directed. |
| 147 | Supply and fixing control cards for output supply of voltage stabilizer of capacity upto 100 KVA all as directed. |
| 148 | Supply and fixing control cards for input supply of voltage stabilizer of capacity upto 100 KVA all as directed. |
| 149 | Supply and fixing control card for high voltage cut off protection reduction of voltage and automatic ON after 10 second time delay all as directed |
| 150 | Repairing/replacementof wiring of panel of DG set of any capacity, with spare parts like relay, contactor switch, indication lamp, wire thimble etc complete all as per sample all as specified & directed by Engr-in-Charge. |
| 151 | Earthing complete with GIearth plate electrode 600cmX600cmX3.15mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to GI strip earth lead strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC type B2 in pit PCC Cover & other arrangement complete all as directed. |
| 152 | M&L in repairs for Earthing complete with galvanizedsteel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc. |
| 153 | Servising of Diesel engine Generating sets 63 KVA to 100 KVA Rating to be carried out as per schedulegiven as under. B - check :- (Every 100 Hrs or 6 months whichever is earlier) (i)Change lubricating oil (ii) change lubricating oil filters (iii)change fuel filters(iv) Change coolant (v)check Engine wiring for damage (vi)Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x)Change fuel water seperator. C - Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii)Steam clean engine (iii)Replace hoses if required (iv) Check turbo charger mounting nuts (v )cCheck engine oil heater (vi) clean rediator (vii) Inspect following parts and replace if required (Alternator,starter etc ) (viii)Clean fuel from inside (ix) Change engine oil. Note :(i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) |
| 154 | Supply and fixs new air filters cartridge elements with \"O\" ring for 15 to 30 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 155 | Supply and fixs new air filters cartridge elements with \"O\" ring for 30 to 63 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 156 | Supply and fixs new air filters cartridge elements with \"O\" ring for 63 to 100 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 157 | Supply only fuel oil filter cartridge elements with \"O\" ring for 15 to 30 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 158 | Supply only fuel oil filter cartridge elements with \"O\" ring for 30 to 63 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 159 | Supply only fuel oil filter cartridge elements with \"O\" ring for 63 to 100 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 160 | Supply only lubricant oil filter cartridge elements with \"O\" ring for 15 to 25 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 161 | Supply only lubricant oil filter cartridge elements with \"O\" ring for 30 to 63 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 162 | Supply only lubricant oil filter cartridge elements with \"O\" ring for 63 to 100 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 163 | Supply onlyfuel water separator filters cartridge elements with \"O\" ring for 63 to 100 KVA DG set complete all as specified and as directed.(Make : Kirlosker/cummins/fleetguard) |
| 164 | Material and labour distilled water for battery complete all as directed. |
| 165 | Supply and fix V-Belt off sizes Make :- Fenner or equivalent as approved by GE complete all as per site requirement complete all as specified and direceted. |
| 166 | Supply and fix Oil pressure gauge ISI marked complete all as specified and as directed. |
| 167 | Supply and fix Oil temparature gauge ISI marked complete all as specified and as directed. |
| 168 | Supply anf fix Fuel gaugemeter ISI marked operated on 24 V DC complete all as specified and as directed. |
| 169 | Sully and fix RPM Meter complete all as specified and directed by Engr-in-Charge. |
| 170 | Supply and fix AVRas per site requirment complete all as specified and directed by Engr-in-Charge. |
| 171 | S&F in replacement of MCCB 415 Volt 16 KA, 4 Pole 63 Amps Capacity complete including taking down old unserviceable MCCBs complete all as specified and as directed. |
| 172 | All as per item No. 171 here-in-before above but 100A, 25KA complete all as specified and as directed. |
| 173 | All as per item No. 171 here-in-before above but 125A, 35KA complete all as specified and as directed. |
| 174 | All as per item No. 171 here-in-before above but 160A, 36KA complete all as specified and as directed. |
| 175 | All as per item No. 171 here-in-before above but 200A, 36KA complete all as specified and as directed. |
| 176 | Taking out Diesel Tank of any capacity carefully including disconnection from system, descaling the diesel tank with water pressure and removing the complete deposited, drying the tank and painting two coat with super enmelled paint out side the tank size, replacement of gate valve and fixing the tank in original location and connection with existing diesel line withreplacement GI/MS fittiing replacement of diesel indicator glass/PVC tube with necessary fitting,repair to any leakage,cleaning and testing of fuel line upto FIP inlet including making of locking arrangements complete up to 600 Ltrs capacity. |
| 177 | Dismantlingof defective alternator/dynamofrom engine supplyingand fixing new alternator24 volts DC Make : TVC Lucas or equivalentas approved by GE including replacementof worn out nuts, bolts mounting clamps etc complete all as specified and as directed. |
| 178 | M&L for filling /toping up of oil in servo voltage stabilizer having dielectric strength upto 35KVA at 2.5mm gap high voltage as per IS/IEC specification ofl low viscosity complete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy