Construction Of Boundary Wall Iron Gate Guest House And Ashram Building Toilet With Running Water Drainage System And Earth Filling Etc. At Bengtol Kumguri Rupamoni Ashram Chirang District Btc Assam. ( Tn_30_9 ) , Bengtal, Chirang-Assam

Bodoland Territorial Council has published Construction Of Boundary Wall Iron Gate Guest House And Ashram Building Toilet With Running Water Drainage System And Earth Filling Etc. At Bengtol Kumguri Rupamoni Ashram Chirang District Btc Assam. ( Tn_30_9 ) . Submission Date for this Tender is 26-11-2021. Wall construction Tenders in Bengtal, Chirang Assam. Bidders can get complete Tender details and download the document.




Tender Notice

29811634
Corrigendum : Construction Of Boundary Wall Iron Gate Guest House And Ashram Building Toilet With Running Water Drainage System And Earth Filling Etc. At Bengtol Kumguri Rupamoni Ashram Chirang District Btc Assam. ( Tn_30_9 )
Open Tender
Indian
Assam
Bengtal, Chirang
26-11-2021

Tender Details

Construction Of Boundary Wall Iron Gate Guest House And Ashram Building Toilet With Running Water Drainage System And Earth Filling Etc. At Bengtol Kumguri Rupamoni Ashram Chirang District Btc Assam. ( Tn_30_9 )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Nov-2021 Corrigendum Date 26-11-2021

Key Value

Document Fees
INR 4300 /-
EMD
INR 283800.0 /-
Tender Value
INR 1.41 Crore /-

BOQ Items

Name of Work: Construction of Boundary Wall, Iron Gate, Guest House & Ashram building, Toilet with running water drainage system and earth filling etc. at Bengtol Kumguri Rupamoni Ashram, Chirang District, BTC, Assam.
Sl. No. Item Description
1(A) Cost of Brick Boundary Wall: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
2Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
3Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
4Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)
5Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0 M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
6Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, columns with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
7Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In Super-Structure from plinth level upto 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
8Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
9112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112mm thick btick wall b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
1015mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 Cement : 4 sand)
11(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
12(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after thouroughly all dirt and remains of loose powered materials.
13Supply fitting fixing M.S angles,M.S. flat ,M.S bolt and nuts including painting with red lead paint one coat complete as directed (a) M.S angles
14Providing barbed wire on the existing barbed wire fencing with seven strands wire 12.S.W.G.X2plies x 4 points at 75mm apart including supplying fitting and fixing with galvanished staples 38mm x 3mm sizes with existing posts of the fencing including removing rotten barbed wire as directed, complete with strengthening of post and tightening of the old barbed wire and joining old serviceable pieces on remaining lines as and where necessary and as directed.
15Supplying fitting and fixing double leaf heavy duty iron gate frame made from 50mm x 6mm M.S flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top and 20mm dia M.S bars 200mm apart from bottom flat to middle flat including drilling welding etc. complete.
16(B) Construction of Mandir (Ground & First Floor): Ground Floor Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
17Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
18Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
19Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) a) From Primary Producer: TATA/SAIl/Esser Steel/Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reinforcement bar
20Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1. Foundation, footing, base of colums, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
21Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.1. Colums, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
22Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.2. Sides and soffits of Beams, beams haunchings, cantilever girders, bressumers, lintels and horizontal ries. (a) For depth not exceeding 1.0M
23Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas,balconies and the like. (a) Floors etc. upto 200mm in thickness.
24Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.5. Sloping or battering surface such as sloped slabs etc. including folded plates. (a) Where inclination to horizontal plane does not exceed 30 requiring shuttering only on the underside.
25Providing and laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using mixture machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) With out admixture, plasticiser (b) M-20 grade concrete ro prop.1:1.5:3
26Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
27Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With silt (predominantly non plastic) by truck carriage including loading and unloading.
28Providing and laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using mixture machine (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. (N) With out admixture, plasticiser (b) M-20 grade concrete ro prop.1:1.5:3
29Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
30112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
31Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
32Providing and fixing in position collapsible M.S. Shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx 5mm size with top and bottom rails of T - iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint
33Providing, fitting and fixing M.S. plain grill of required pattern for windows/clerestory windows opening with M.S. flats at required spacing in frame all round, square or or round M.S. bars with round headed bolts and nuts or screws. I. Plain grill c) Fixed to Brickwork/PCC/RCC
34Providing, and fixing Stainless Steel (Godrej 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of Stainless Steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
35Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with agg. Of size 13mm to 32mm including dewatering if necessary and curing etc. complete. Ii) 50mm thick.
36Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) b) Executive Range (Somany/Orient/Nitco/Varma/VITA/Marbito/Make i) Of size 800mm x 800mm and above
3718mm thick marble stone slab flooring of size 1200 x 1200 including treads and risers of steps, skirting laid over 20mm thick base of cement plaster 1:6 (1cement: 6 coarse sand) laid and joined with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Dungri slab
3815mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 cement : 4sand)
39Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
40Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/Berger/ Dulux over concrete/cement plaster/brick walls and ceilling both internal and external after removing all the loosely adhering material from the wall/ceilling surface with the help of emery stone, putty blade or wire brush, moisterning the wall with the help of sufficient quantity of clear water as specified and directed by the department.
41Wall Painting (two coats) with plastic emulsion paint of approved brand and manufacture (Asian/paint/Berger paint/ICI paint/J & N /Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
42Applying one self- priming coat of acrylic emulsion paint of approved brand, thinning by adding water as per the specification of manufacturer over freshly plastered wall surface after throughly brooming the surfaces free mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. c) Asian paint
43Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade, thinning by adding water as per specification of manufacturer after throughly brooming the surfaces to removed all dirt and remains of loose powdered materials as specified and directed by the department. c) Asian paint
44Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine stees, wood scrapers and sand paper. a) With ready mixed red-lead/red oxide primer.
45Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth b) High gloss (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
46Providing drain with brick work in cement mortar in prop 1:5 with half brick thick side walls and 100mm thick CC (1:3:6) base over one brick flat soiling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shettering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (ii) 300 wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
47Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
48First Floor Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) a) From Primary Producer: TATA/SAIl/Esser Steel/Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reinforcement bar
493.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
503.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintel & horizontal ties. (a) For depth not exceeding 1.0M
513.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas,balconies and the like. (a) Floors etc. upto 200mm in thickness.
52Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In Super-Structure from plinth level upto 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
53Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
54112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112mm thick btick wall b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
55Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
56Providing and fixing in position collapsible M.S. Shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx 5mm size with top and bottom rails of T - iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
57Providing, fitting and fixing M.S. plain grill of required pattern for windows/clerestory windows opening with M.S. flats at required spacing in frame all round, square or or round M.S. bars with round headed bolts and nuts or screws. I. Plain grill c) Fixed to Brickwork/PCC/RCC
58Providing VITRIFIEDfloor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) b) Executive range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make i) Of size 800mm x 800mm and above
59Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mm x 450mm and above.
6015mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 Cement : 4 sand)
61Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
62Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/Berger/ Dulux over concrete/cement plaster/brick walls and ceilling both internal and external after removing all the loosely adhering material from the wall/ceilling surface with the help of emery stone, putty blade or wire brush, moisterning the wall with the help of sufficient quantity of clear water as specified and directed by the department.
63Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approvedbrand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
64Applying one self- priming coat of acrylic emulsion paint of approved brand, thinning by adding water as per the specification of manufacturer over freshly plastered wall surface after throughly brooming the surfaces free mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. c) Asian paint
65Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade, thinning by adding water as per specification of manufacturer after throughly brooming the surfaces to removed all dirt and remains of loose powdered materials as specified and directed by the department. c) Asian paint
66Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine stees, wood scrapers and sand paper. a) With ready mixed red-lead/red oxide primer.
67Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth. b) High Gloss (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
68(C) Construction of Guest House: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
69Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
70Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
71Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT bars
72Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1. Foundation, footing, base of colums, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
733.1.1.2. Sides and tie beams, grade beams etc. ground level. (b) Using 25mm thick plank.
743.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
753.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintel & horizontal ties. (a) For depth not exceeding 1.0M
763.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas,balconies and the like. (a) Floors etc. upto 200mm in thickness.
77Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, columns with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
78Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
79Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With silt (predominantly non plastic) by truck carriage including loading and unloading.
80Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In Super-Structure from plinth level upto 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
81Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
82112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112mm thick btick wall b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
83Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black-tubes conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
84Providing Bare Galvalume Sheet Roofing at all levels including fitting and fixingself drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iv) 0.60 mm thick
85Providing Bare Galvalume Sheet Roofing accessories (Ridges/Valley/Gutter/Flashing) at all levels including fitting and fixing self drilling self tapping screws complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement. (iv) 0.60 mm thick
8615mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4 (1 Cement : 4 sand)
87Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
88Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand (HINDALCO/NALCO/BALCO/JINDAL/Other equivalent primary producer) without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (b) 3 Track sliding window (i) 6mm clear glass
89Providing fitting and fixing coloured aluminium windows and ventilators of standard sections without horizontal glazing bars joints mitred and welded (manufactured to relevent IS specifivcations) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm in 1:3:6 mix including providing and fixing handles frictions stys, joining cleat, bolting device, locking arrangement, spring catch as required complete as specification and directed for all levels (Cement concrete to be measured and paid separately). (b) Fixed window and ventilator (ii) 5mm frosted glass.
90Providing fitting and fixing anodised aluminium glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section with door style of size 88mm x 45mm x 2.5mm top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bttom rails 100mm x 45mm x 2.5mm fitted with glazzing clip special type rubber gasket complete including including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, clear etc. complete as specified and directed by the department at all levels. (vi) Prelaminated Board
91Providing, fitting and fixing M.S grill of required pattern for windows/ clerestory windows/ opening with M.S flats at required spacing in frame all round square or round M.S bars with round headed bolts and nuts or screws. Ii) Ornamental grill C) Fixed to Brickwork/PCC/RCC
9265mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 25mm down) and 15mm thick wearing layer in cement concrete 1:1:2 (1 cement : 1 coarse sand : 2 coarse agg of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg per sqm of floor area) including curring etc.complete as directed.
93Providing and fixing in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with maon runner 38 x 24mm cross tec 29mm x 24mm & wall angle 24mm x 24mm Using 4mm/6mm thick High pressure steam cured Non Asbestos Fibre Cement Board as per IS 14862 to be placed in a grid of G.I system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkles, smoke detectors etc. The main runners to be secured to structural soffi byhanger @ 1120mm maxium c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. Finaly if specified boards are to be painted with 2 coats of achieve emulsion paint of approved shade/make cover a coat of cement primer before installing it on the qrid. (A) Standard Ceilings of Everest make or equivalent as directed by the department. (ii) Using 6mm thick FC Board.
94Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
95Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/Berger/ Dulux over concrete/cement plaster/brick walls and ceilling both internal and external after removing all the loosely adhering material from the wall/ceilling surface with the help of emery stone, putty blade or wire brush, moisterning the wall with the help of sufficient quantity of clear water as specified and directed by the department.
96Wall Painting (two coats) with plastic emulsion paint of approved brand and manufacture (Asian/paint/Berger paint/ICI paint/J & N /Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
97Applying one self- priming coat of acrylic emulsion paint of approved brand, thinning by adding water as per the specification of manufacturer over freshly plastered wall surface after throughly brooming the surfaces free mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. c) Asian paint
98Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade, thinning by adding water as per specification of manufacturer after throughly brooming the surfaces to removed all dirt and remains of loose powdered materials as specified and directed by the department. c) Asian paint
99Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
100(D) Construction of Kitchen & Dining: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
101Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
102Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
103Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT bars
104Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1. Foundation, footing, base of colums, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
1053.1.1.2. Sides and tie beams, grade beams etc. ground level. (b) Using 25mm thick plank.
1063.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
1073.2.1.2. Sides and soffits of beams,beam haunchings,cantilever, girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
1083.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas,balconies and the like. (a) Floors etc. upto 200mm in thickness.
109Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, columns with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
110Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
111Earth/ sand filling in plinth in layers not more than 150mm thick inch. necessary carriage, watering, ramming, etc. Complete as directed and specified including payment of land compensation forest royalty sales tax and other duties and raxes as may be necessary. (C) With silt (predominantly non plastic) by truck carriage including loading and unloading.
112Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In Super-Structure from plinth level upto 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
113Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
114112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112mm thick btick wall b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
115Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black-tubes conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
116Providing Bare Galvalume Sheet Roofing at all levels including fitting and fixingself drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iv) 0.60 mm thick
117Providing Bare Galvalume Sheet Roofing accessories (Ridges/Valley/Gutter/Flashing) at all levels including fitting and fixing self drilling self tapping screws complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement. (iv) 0.60 mm thick
11815mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4 (1 Cement : 4 sand)
119Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
120Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand (HINDALCO/NALCO/BALCO/JINDAL/Other equivalent primary producer) without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (b) 3 Track sliding window (i) 6mm clear glass
121Providing fitting and fixing coloured aluminium windows and ventilators of standard sections without horizontal glazing bars joints mitred and welded (manufactured to relevent IS specifivcations) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm in 1:3:6 mix including providing and fixing handles frictions stys, joining cleat, bolting device, locking arrangement, spring catch as required complete as specification and directed for all levels (Cement concrete to be measured and paid separately). (b) Fixed window and ventilator (ii) 5mm frosted glass.
122Providing fitting and fixing anodised aluminium glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section with door style of size 88mm x 45mm x 2.5mm top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bttom rails 100mm x 45mm x 2.5mm fitted with glazzing clip special type rubber gasket complete including including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, clear etc. complete as specified and directed by the department at all levels. (vi) Prelaminated Board
123Providing, fitting and fixing M.S grill of required pattern for windows/ clerestory windows/ opening with M.S flats at required spacing in frame all round square or round M.S bars with round headed bolts and nuts or screws. Ii) Ornamental grill C) Fixed to Brickwork/PCC/RCC
12465mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 25mm down) and 15mm thick wearing layer in cement concrete 1:1:2 (1 cement : 1 coarse sand : 2 coarse agg of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg per sqm of floor area) including curring etc.complete as directed.
125Providing and fixing in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with maon runner 38 x 24mm cross tec 29mm x 24mm & wall angle 24mm x 24mm Using 4mm/6mm thick High pressure steam cured Non Asbestos Fibre Cement Board as per IS 14862 to be placed in a grid of G.I system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkles, smoke detectors etc. The main runners to be secured to structural soffi byhanger @ 1120mm maxium c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. Finaly if specified boards are to be painted with 2 coats of achieve emulsion paint of approved shade/make cover a coat of cement primer before installing it on the qrid. (A) Standard Ceilings of Everest make or equivalent as directed by the department. (ii) Using 6mm thick FC Board.
126Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
127Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/Berger/ Dulux over concrete/cement plaster/brick walls and ceilling both internal and external after removing all the loosely adhering material from the wall/ceilling surface with the help of emery stone, putty blade or wire brush, moisterning the wall with the help of sufficient quantity of clear water as specified and directed by the department.
128Wall Painting (two coats) with plastic emulsion paint of approved brand and manufacture (Asian/paint/Berger paint/ICI paint/J & N /Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
129Applying one self- priming coat of acrylic emulsion paint of approved brand, thinning by adding water as per the specification of manufacturer over freshly plastered wall surface after throughly brooming the surfaces free mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. c) Asian paint
130Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade, thinning by adding water as per specification of manufacturer after throughly brooming the surfaces to removed all dirt and remains of loose powdered materials as specified and directed by the department. c) Asian paint
131Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
132(E) Construction of Toilet Block: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
133Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
134Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
135Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) a) From Primary Producer: TATA/SAIl/Esser Steel/Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reinforcement bar
136Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1. Foundation, footing, base of colums, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
1373.1.1.2. Sides and tie beams, grade beams etc. ground level. (b) Using 25mm thick plank.
1383.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
139Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, columns with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
140Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
141Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With silt (predominantly non plastic) by truck carriage including loading and unloading.
142Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In Super-Structure from plinth level upto 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
1433.1.1.4 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. (ii) Using 25mm thick plank
144Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
145112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112mm thick btick wall b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
146Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black-tubes conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
147Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick and purlin etc.(Roof trusses and purlin etc. to be measured and paid separately). (c) 0.55mm thick
14815mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 Cement : 4 sand)
149Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
150Providing fitting and fixing 40mm x 48mm wood reinforced PVC chowkhats foxed to the colums /stiffencrs/walls with necessary holdfast/sleeves etc. as specified and directed at all levels.
151Providing fitting and fixing 24mm x 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkhath with necessary hinges,screws,bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid separately) b) 29mm thick
152Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with agg. Of size 13mm to 32mm including dewatering if necessary and curing etc. complete. Ii) 50mm thick in prop.1:3:6
153Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) b) Executive Range (Somany Varma/Orient make) i) Of size 800mm x 800mm
154Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mm x 450mm and above.
155Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
156(a) Clour washing with lime on wall surface (two coats) over and including a priming coat of white washing to give an even shade afterthouroughly brooming the surface to remove all dirt, dust mortar drops and other foreign matter.
157Providing drain with brick work in cement mortar in prop 1:5 with half brick thick side walls and 100mm thick CC (1:3:6) base over one brick flat soiling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shettering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (ii) 300 wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
158Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
159Sanitary and Water Supply Works: Providing fitting and fixing vitreous water closet squatting pan (indian type W.C Orrisa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) 1.1.1 Indian type W.C Orrisa pattern of size 580 x 440mm a) White (ii) Hindware make
160Supplying, fiting and fixing PVC flushing cisternwith all internal fittingswith CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make a) White (viii) Tiger (Cat No.C8260)
161Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (A) Parryware make a) White (iv) Flat Back (Cat. No.C0501/72)
162Providing vitreous Chinawash basinwith CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) 1.13.2 Basin (without pedestal) (A) Parryware Make (ii) Tapti Basin 500 x 360 (Cat. No.C0424/410)
163Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
164Providing fitting and fixing recessed soap tray/soap dish complete as directed and specified. (a) Parryware make (iii) Corner Soap tray (Cat No.C9949)
165Providing fitting and fixing PVC cowel of ISI make complete as directed and specified (ii) 110mm dia PVC cowel of ISI make
166Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary "R" brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches d) 25 mm
167Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary "R" brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches e) 20 mm
168Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary "R" brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches f) 15 mm
169Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (I) Essco make (Delux/Sumthing spl./Tropical) (a) Bib cock short
170Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (ii)20mm dia
171Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (i) Sona make (b) Heavy type
172Supplying fitting and fixing Chrome Plated (C.P.) flush cock ofapproved brand as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (I) Agmeco brand a) Flush cock Economy Cat No.00506
173Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) vii) 63mm diameter
174Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) x) 110mm diameter
175Septic Tank: Earth work in excavation for foundation trenches of walls, retaining walls.footing of colums,steps and septic tank etc. including refiling (return filling) the quantity as necessary after completing of work. breaking clods in return filling dressing. watering and ramming etc and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
176Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
177Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
178Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (upto 1st floor level) c) ISI approved Mild steel reinforcement bar (M.S.Bar)
179Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. Upto 200mm in thickness (ii) Using 25mm thick plank.
180Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
181Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using Mixer Machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture plasticiser a) M-15 grade concrete or prop.1:2:4
18215mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 Cement : 4 sand)
183(F) Construction of Over Head Tank: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
184Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
185Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
186Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (Upto 1st floor level) a) from Primary Producer: TATA/SAIL/Esser Steel/Jindal (i) TMT Corrosion resistant steel(CRS) reinforcement bar.
187Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1. Foundation, footing, base of colums, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
1883.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
1893.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintel & horizontal ties. (a) For depth not exceeding 1.0M
1903.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas,balconies and the like. (a) Floors etc. upto 200mm in thickness.
191Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, columns with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
192Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
193Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With silt (predominantly non plastic) by truck carriage including loading and unloading.
194Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In Super-Structure from plinth level upto 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
195Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
196112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112mm thick btick wall b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
19715mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 Cement : 4 sand)
198Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
19965mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 25mm down) and 15mm thick wearing layer in cement concrete 1:1:2 (1 cement : 1 coarse sand : 2 coarse agg of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg per sqm of floor area) including curring etc.complete as directed.
200Providing fiting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigid ly fixed togheter by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be up with 1:4:4 PCC after fitting the frame with brick/concrete works etc. complete as directed for all levels. (PCC to be measured and paid for seperately) (b) 1.60mm thick sheet (ii) Size 105mm x 60mm (Single rebate)
201Providing fitting and fixing factory mado Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber , 25mm core battens.25mm to 35mm uniformaly thick cross bands style & rails made from hardwood timber of width not less than 50mm fixed to the door frames (chowkath) with necessary hings,screws,bolts etc as specified and directed at all levels (Door fixtures and fittings to be measured ann paid seperately) b) 35mm thick
202Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
203Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem ""Rakshak"" brand required shade by thining 1ltr of paint with 750ml of water to give an even shade throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
204Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches and fefilling the same etc complete as directed. A) G.I pipe with GI fittings a) TATA/SAIL (medium) v) 40mm diameter.
205Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches and fefilling the same etc complete as directed. A) G.I pipe with GI fittings a) TATA/SAIL (medium) iv) 32mm diameter.
206Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches and fefilling the same etc complete as directed. A) G.I pipe with GI fittings a) TATA/SAIL (medium) iii) 25mm diameter.
207Supplying fitting and fixing stop-cock of approved brand of size as mentioned and directed and specified (G.I & C.P pipes will be measured and paid separetely) I) Brass stop cock (heavy) of Sant make iv) 32mm dia.
208Supplying fitting and fixing pump for 40mm dia tube well with all accessories complete as directed. i) Maya popular 6
209Labour for boring hole for inserting tube well pipes through different soil/rockk media including hire charges of drill pipes,scaffolding,tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. i) Bore hole of 150mm diameter
210Supplying, fitting and fixing plain/bevel ended for casing, conforming to relevent IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign material in the annual space between the borehole and assembly pipes complete as directed by the Department. ii) PVC PIPE SUPREME/PRINCE/FUSION/SFMC Brand vi) 140m diameter
211Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B. PVC PIPE SUPREME / PRINCE / FUSION /SFMC Brand vi. 75mm diameter
212Supplyingfitting and fixing ISI approved PVC filter 3.00 metre long. V. 150mm diameter
213Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (I) 2000 Lt capacity (a)Sintex make
214Single phase Submersible motor pump set(Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guarsuitable for 100 mm bore well and above. 1.5 HP STAGE 5 to 26with control panel.
215(G) Construction of Garage: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
216Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
217Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
218Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) a) From Primary Producer: TATA/SAIl/Esser Steel/Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reinforcement bar
219Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0 M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
2203.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintel & horizontal ties. (a) For depth not exceeding 1.0M
221Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, columns with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
222Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
223Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With silt (predominantly non plastic) by truck carriage including loading and unloading.
224Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In Super-Structure from plinth level upto 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) With out admixture, plasticiser. (b) M20 Grade Concrete or prop 1:1.5:3
225Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
226112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112mm thick btick wall b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
227Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black-tubes conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
228Providing Bare Galvalume Sheet Roofing at all levels including fitting and fixingself drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iv) 0.60 mm thick
22915mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 Cement : 4 sand)
230Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
23165mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 25mm down) and 15mm thick wearing layer in cement concrete 1:1:2 (1 cement : 1 coarse sand : 2 coarse agg of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg per sqm of floor area) including curring etc.complete as directed.
232Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
233(a) Clour washing with lime on wall surface (two coats) over and including a priming coat of white washing to give an even shade afterthouroughly brooming the surface to remove all dirt, dust mortar drops and other foreign matter.
234Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
235Providing drain with brick work in cement mortar in prop 1:5 with half brick thick side walls and 100mm thick CC (1:3:6) base over one brick flat soiling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shettering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (ii) 300 wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
236(H) Construction of Approach Road: Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300.2 (including compensation of earth) (Including cost of testing of materials at site and laboratiry as directed by the deptt.) (i) From Private land
237Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300.2 (including compensation of earth) (Including cost of testing of materials at site and laboratiry as directed by the deptt.) (i) From Private land (c) Extra lead beyond initial lead of 3.00km
238Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve thedesired density, complete as per Clause 401 of MORTH Specifications (with an initial lead of 5 Km) (Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) Using Grading II Material.
239Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve thedesired density, complete as per Clause 401 of MORTH Specifications (with an initial lead of 5 Km) (Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) Using Grading II Material. (d) Extra lead beyond initial lead of 5.00km
240Providing and laying controlled cement concrete pavement of approved grade with 20mm down graded stone aggregate over a prepared sub-base including dewatering if necessary, spread, compacted and finished in acontinuous operation including provision of construction and expansion joints, plastering and curing compound of Fosroc/Sika/Choksey/Degusa and hardener of Recron/Degusa/Fosroc, finishing to lines and grades and curing complete as specification and directed complete. (from work and reinforcement shall be measured and paid separately) (b) M-25 Grade Concrete.
241Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
242Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
243Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
244Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
24515mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 Cement : 4 sand)
246(I) Construction of Drain: RCC Drain Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
247Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
248Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
249Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)
2503.3.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders and bressumers.
2513.3.1.3 Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
2523.3.1.5 Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
253Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) with out admixture, plasticiser (b) M20 grade concrete ro prop. 1:1.5:3
254Peripheral Drainage: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
255Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
256Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, bricks works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement : 3 coarse sand: 6 coarse aggregate by volume. (using mixture machine)
257Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)
258Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0 M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
259Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) with out admixture, plasticiser (b) M20 grade concrete ro prop. 1:1.5:3
260Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
26115mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 Cement : 4 sand)
262Supplying fitting and fixing M.S angles MS flat MS bolts and nut including painting with red lead paint one coat complete as directed.. b) MS flats.
263(J) Cost for Earth Filling: Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees if any monopoly duty etc. (profile meassurement to be taken and 12.5% deduction for shrinkage to be made from total quantuty) etc. complete as per directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned.
264(K) Electrification: Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing "n" capping (AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. Short point up to 3.00 metre. length.
265Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing "n" capping (AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. Medium point up to 6.00 metre. length.
266Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing "n" capping (AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. Long point up to 10.00 metre. length.
267Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing "n" capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) system including earth continuity. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing "n" capping system.
268Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing "n" capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) system including earth continuity. With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in flat 19 mm ISI marked casing "n" capping system.
269Wiring for 5 pin 6 amp plug with 1.5 sq mmP.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socketas required on the switch board in surface/ recessedP.V.C. conduit wiring system. When fitted on same board of light and fan.
270Supplying and fiixing of batten holder (Anchor Penta PC CHERRY/Gold medal/Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.) as required With out Lamp.
271Supplying and fixing of Jaquar or equivalent Philips/Wipro LED wall light fittings complete with Shade, back plate including connection cable, as approved by the Deptt. S etc. as required. LED Bulk Head 8W
272Supplying and fitting of 18/20 Watt LED/CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc. as specified and directed by the deptt.
273Supplying with fitting and fixing sheet steel, phosphatised, powder painted single door surface mounting MCB DB incorporated with bas-bar Neutral linl, Earth bar and din rail etc fitted on wall with grounting nuts & bolts as reqd. Complete with making necessary connection as approved, specified and directed by the deptt. 4 way SPN single door.
274Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. B Series 6 to 32A
275Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. B. Series 6 to 32A
276Supply installation & testing of G.I earth station with perforated 40 mm dia and 4.50 mt long heady duty G.I pipe with necessary 40 mm dia. G.I. Fitting such as Socket, tee, elbow, nipple and 50mm x 40mm G.I. reducing socket for funnel including locking arrangement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging earth pit, construction of brick chamber and plastering of both inner of outer surface of wall as specified and directed by the deptt.
277Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.)
278Supplying & laying of 8 SWG Copper. Earth from Earth Electrode (below G.L) to electrical switch gear or electrical machineries including making necessary connection as approved specified and directed by the deptt.
279Supplying with fitting fixing of LED/CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection cable, as approved by the Deptt.) with 1.5 sq mm P.V.C. insulated S.C.copper conductor as required and as directed by the department. Striplite luminaries complete with VPIT copper ballast/ Electronic ballast and decorative end cap and 1 X 36 / 40 wattFluorescent tube. (Crompton Greavesmake) Model- DSG1114LDB CROMGOLD / DSG1114LDBN CROM GOLD NEW / DSG1314EB CG GOLD / DSG 1414EB PLANET GOLD with Super Saver / Super Brite Lamp. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUARmake.
280Supplying including fitting fixing of followingA.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department [Without regulator]. Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 /1200 mm Sweep SS-390 Deco Havellsmake)
281Supplying fitting and fising of ceiling fan regulator including connection etc. complete as required. Electronic type.
282Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etc. to proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/Finolex make) 2 Core A2XWaY A2XFaY 16.00 Sq.mm 2 Core armoured U.G. cable (For service line)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail