| 1 | SCHEDULE \"A\" |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 4 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital orsimilarpattern roof coverings complete all as specified and directed. |
| 5 | S&F mild steel work as hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters,nosingtosteps includingembedinginconcrete and screwing etc. wind ties for roofincluding securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 6 | S&F mild steel work as framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 7 | S&F rolled mild steel plates (plain or chequered) channels,squarecutor notched (ordinaryand countersunk) forming holes, without any attachment complete all as specified and directed. |
| 8 | S&F rolled mild steel work as rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 9 | S&F rolled mild steel work as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 10 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240 complete all as specified and directed. |
| 11 | M&L prepartion of new steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome complete all as specified and directed. |
| 12 | Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and directed. |
| 13 | S&F in repairs stainless steel work including welding, polishing etc complete all as specified and directed. |
| 14 | M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed |
| 15 | M&L for Non - skid Ceramic colouredtiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 16 | M&L for Non - skid Ceramic colouredtiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed. |
| 17 | M&L for Vitrified Ceramic tiles, light shade, 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 18 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisescomplete all as specified and directed. |
| 19 | M&L for rendering 10mm thick on fair faces of brick work in CM 1:4 as backing coat complete all as specified and directed. |
| 20 | M&L for 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 21 | S&F in repairs 110mm bore PVC (SWR) pipe of pressure rating 10kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 22 | S&F in repairs 75mm bore PVC (SWR) pipe of pressure rating 10kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 23 | Dismantling water tanks and removing to store exc 250 ltr and not exc 500 ltr complete all as specified and directed. |
| 24 | Dismantling water tanks and removing to store exc 500 ltr and not exc 1000 ltr complete all as specified and directed. |
| 25 | S&F 250 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Partcomplete all as specified and directed. |
| 26 | S&F 500 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Partcomplete all as specified and directed. |
| 27 | S&F 750 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part complete all as specified and directed. |
| 28 | S&F 1000 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part complete all as specified and directed. |
| 29 | S&F in repairs aluminium weather strip with Nylon brush insert suitable for bottom of door shutters of wooden/aluminum all as specified and directed. |
| 30 | S&F in repairs Solar control film 50 micron reflective type sticked to glass panes as per instructions of manufacturers all as specified and directed. |
| 31 | S&F in repairs venetian blind using cotton/Nylon fabric of size 10cm wide and length as required including power coated aluminium channel, operating rope etc all as specified and directed. |
| 32 | S & F in repair alumimum die cast body door closer hydraulically regulated, designation No 2, universal type, suitable for door shutters of 801 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. |
| 33 | S & F in repairs double action floor spring hydraulically regulated, made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty suitable for aluminium doors openable in two directions complete all as specified and directed. |
| 34 | S&F in repairs 75mm long half folded auto hingescomplete all as specified and directed. |
| 35 | S&F 25mm dia decorative curtain rods powder coated MS of approved pattern / colour / design of including decorative end fittings , brackets etc. fixed in repairs. complete all as specified and directed. |
| 36 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground embedded in concrete, brick work, masonry etc complete all as specified and directed. |
| 37 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 38 | M&L for PCC 1:4:8 type D2, using 40mm graded stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 39 | S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 40 | M&L for Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sq. cm and not exc 250 sqcm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and directed. |
| 41 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 42 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 43 | Dismantling of chain link fencing any type and any size complete all as specified and directed. |
| 44 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, diameter of neck 11 to 15mm complete all as specified and directed. |
| 45 | S&F in repairs Galvanised. 2 strand, steel barbedwire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured complete all as specified and directed. |
| 46 | M&L for chequered cement concrete tiles 300x300x20mm thick set and jointed and pointed in neat cement slurry in floor with grey cement and no pigment complete all as specified and directed. |
| 47 | S&F Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment. complete all as specified and directed. |
| 48 | M&L for 20mm thick screed bed or bedding layer for laying floor finishes in CM 1:6 complete all as specified and directed. |
| 49 | Supply and spreading coarse aggregate from 12.5mm to 4.75mm not exc 25cm thick complete all as specified and directed. |
| 50 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 51 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. |
| 52 | Demolition ofConcrete of any description and in anypositionnot otherwise specifically provided for complete all as specified and directed. |
| 53 | M&L 75mm thick PCC 1:4:8 type D2, using 40mm graded stone aggregate as in floors complete all as specified and directed. |
| 54 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m meanradius built in CM 1:4, complete all as specified and directed. |
| 55 | Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, builtin CM 1:6 complete all as specified and directed. |
| 56 | Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, builtin CM 1:6 (Except stone) complete all as specified and directed. |
| 57 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius inhalf brick thick walls built in CM 1:4 complete all as specified and directed. |
| 58 | Demoitioin of brickwork or stone/ boulder masonry, built in cement or cement lime mortar including allquoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 59 | M&L for rendering 15mm thick on fair face of brick work or concrete surface in CM 1:6 complete all as specified and directed. |
| 60 | M&L for PCC 1:2:4 type B1 (20mm graded stone aggregate) as in coping complete all as specified and directed. |
| 61 | M&L for preparation of new plastered surface of wall and applying two coats of weather coat paint APEX over a coat of alkali resistance primer complete all as specified and directed. |
| 62 | M&L for Providing precast cement concrete 1:2:4 type B0 (12.5mm graded stone aggregate) louvres and jallies, 25mm thick(mea suredsolid), including all mould- ingsbut excluding frame set in CM 1:4.(Pre cast frame shall be measuredseparately and paid for under item 04032).complete all as specified and directed. |
| 63 | Providing 1:2:4, type B1 (20mm graded stone aggregate) precast cement concrete in win- dow or door cills,lintels, bressumers,steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks,ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, includingchamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified and directed. |
| 64 | Demolition/dismantloing of RCC louvers and jallies of any description and any type complete all as specified and directed. |
| 65 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses Hammer dressing with maximum depression on face from straight edge held against the dressed surface not exc 40mm granite or trap stone complete all as specified and directed. |
| 66 | M&L for surface dressing not exc 15cn deep in soft/loosed soil with grass around the manhole, soak well, drain and septic tank all as specified and directed. |
| 67 | Cleaning ofGulli trap/Nahani trap with cleaning tools and getting out sludge, mud, silt or other foregin materials complete all as specified and as directed by Engineer in Charge. Note :- Obtained waste materials shall be disposedto a distance not less than 100 mtrs as directed by Hygenic authorities) complete all as specified and directed. |
| 68 | M&L for making good damaged surfaces of sorroundings of nahani trap, Gulli trap/floor traps etc with CM 1:3 or white cement complete all as directed by Engineer in Charge. |
| 69 | Cleaning of septic tank by removing man hole cover including removing of earth/soil spread over the cover if any, from the frame of a septic tank and receiving chambers, pumping out liquid contents and excavating night soil sediments and waste materials etc, clearing off up to the bottom floor and dispose off the materialsto a distance not exceeding 100 mtrs from the septic tank to a pit suitably as directed by Hygenic authorities excavatedto contain night soil, place back the man hole cover to its original position and removing all vegetable roots if any and making good surroundings complete all as specified and directed, including the cost of excavating the pit and refilling back. Note:-The measurment shall be inclusive of water content from bottom of tank to the invert level of outlet pipe, complete all as specified and directed. |
| 70 | Opening manholes of septic tanks, removing night soil, other sediments, solid waste and liquid waste in any condition by pumping or any other mechanical means, cleaning internal surfaces of the tank with clean water and refixing the manhole on completion of work complete all as specified and directed.Notes:-(a)The night soil, sediments, solid and liquid waste in any condition removed from septic tank shall be taken away from respective vicinities and premised in closed containers/converyance and disposed off out of Defence land.(b)Disposal of the same shall be the responsibility of the Contractor. Disposal of waste shall be made in accordance with the regulations of authorities concerned without any extra expediture to the Government. |
| 71 | Cleaning Man holes of depth not exc 1.5m by removing man hole cover, dewatering and getting out sludge, deposit mud, silt or other foregin materials and vegetation and cleaning the sides and floors of the man hole, removing over flowed sulage from sorounding of man holes and removing the same outside the defence land including taking of manholes covers and refixing the same in position and testing of manholes by filling with water complete all as specified and as directed. |
| 72 | Cleaning Man holes of depth exc 1.5m but not exc 3.00mby removing man hole cover, dewatering and getting out sludge, deposit mud, silt or other foregin materials and vegetation and cleaning the sides and floors of the man hole, removing over flowed sulage from sorounding of man holes and removing the same outside the defence land including taking of manholes covers and refixing the same in position and testing of manholes by filling with water complete all as specified and as directed. |
| 73 | CleaningSWG/PVC/CI pipe sewage line manually or mechanically using cleaning rod or compressor and removing foreign material after clearing existing blockage for 75mm dia pipe in vertical walls/floors complete all as specified and directed. |
| 74 | CleaningSWG/PVC/CI pipe sewage line manually or mechanically using cleaning rod or compressor and removing foreign material after clearing existing blockage for 110mm dia pipe on vertical walls/floors complete all as specified and directed. |
| 75 | CleaningSWG/PVC/CI pipe sewage line manually or mechanically using cleaning rod or compressor and removing foreign material after clearing existing blockage for 150mm dia pipe complete all as specified and directed. |
| 76 | Excavation in trenches n.exc 1.5 M wide and n exc 1.5 M depth and getting out in hard/dense soil complete all as specified and directed. |
| 77 | M&L for PCC 1:4:8 type D2, using 40 mm graded aggregate in foundation, mass concrete complete all as specified and directed. |
| 78 | S&F in repairs150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed |
| 79 | M&L for cement concrete bed to drain pipe 150 mm dia in cement concrete 1:3:6 type C2 including packing under the haunching on sides all as directed and specified |
| 80 | S&F In reapirs PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement and making good the surfaces all as directed and specified |
| 81 | Returning, filling ramming etc in layers n.exc 25 cum including levelling, watering etc complete all as directed |
| 82 | Removing excavated materials not exc 50 Mtr and depositing where directed at level n. exc 1.5 Mtr above from the starting point complete all as specified and directed. |
| 83 | PCC 1:3:6type in foundation type C2 using 40mm graded aggregate in manhole foundation all as specified and directed |
| 84 | M&L for PCC Coping in PCC 1:2:4 type B1 using 20mm gradedaggrgateincluding chamfered edges all as specified and directed |
| 85 | M&L of cement concrete type B 1:2:4 20mm graded aggregate as in surface channels, benching inside manholes complete all as specified and directed |
| 86 | M&L for precast reinforced concrete 1:2:4 type B1 using 20 mm graded stone aggregate for cover slab set in and pointed in CM 1:6 including necessary formwork complete all as specified and directed. |
| 87 | Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed. |
| 88 | S&F anodised aluminium snap grid frame work of size 605mmx605mm snap grid for false ceiling all as specified including dhngers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 89 | Dismantling wallandceilingboards(fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets/aluminium frame work or grid |
| 90 | Dismantling wallandceilingboards(fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness |
| 91 | M&L for preparation of new ceiling or ceiling board and applying two coats of oil bound distemper over a coat of alkali resistance primer complete all as specified and directed. |
| 92 | M&L for roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed. |
| 93 | M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified and directed. |
| 94 | Dismantling of single layer Mangalore pattern or similar tiles in roofing complete all as specified and directed. |
| 95 | M&L for preparation of mangalore pattern tiles and applying applying two coats of weather proof paint/APEX Paint complete all as specified and directed. |
| 96 | Dismantling boarding including fittings, if any, any description fixed in any position with nails complete all as specified and directed. |
| 97 | M&L for 9mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination fixed with screws to timber frame work complete all as specified and directed. |
| 98 | M & L for 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work etc complete all as specified and directed. |
| 99 | M & L for 18/19 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination fixed with screws to timber frame work complete all as specified and directed. |
| 100 | S & F in repairs butt hinges medium weight cold rolled mild steel 100 mm long complete all as specified and directed. |
| 101 | S & F in repairs 150 mm long extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed. |
| 102 | S&F in repairs Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed |
| 103 | Sub Total of Schedule \"A\" |
| 104 | SCHEDULE OF CREDIT |
| 105 | Schedule of Credit (Minus) Rs.45564.00 B/F from Ser page No.120.NOTE: Bidder shall insert credit amount as rate Rs.45564.00 in Green field under Col-5. |
| 106 | Sub Total of Schedule of Credit |