Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #29787193

Bids Are Invited For Lcd Digital Magnetic Hotplate Stirrer With Timer - ? Heating Temperature Range Of Rt To 300° C With Hating Power Of 550 W Or More.? Integrated Temperature Control With Incl. Pt 1000 Temperature Sensor.? Digital Led Display For Both Sp

Issued by Boards / Undertakings / PSU · , Jammu And Kashmir
Tender Value
7.75 Lakhs
Estimated cost
Bid Submission
25 Nov 2021
0 days left
EMD
23250
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids Are Invited For Lcd Digital Magnetic Hotplate Stirrer With Timer - ? Heating Temperature Range Of Rt To 300° C With Hating Power Of 550 W Or More.? Integrated Temperature Control With Incl. Pt 1000 Temperature Sensor.? Digital Led Display For Both Speed And Set And Actual Temperature Of Medium.? Maximum Stirring Quantity Should Be 15 L Or More With Speed Range Of 50-1500 Rpm.? Adjustable Safety Temperature Limits ( 50 - 360 °C ) For Avoiding Flash Points Of Medium.? Hot Top Indicator >> Hot Surface Warning To Prevent Burns!? Digital Error Code Display.? Bushing According To Din 12878 For Connecting A Contact Thermometer With Capacity To Control Medium Temperature With Accuracy Of ±0.2 K And Measure The Ph Of Solution By Connecting An External Ph Electrode And Should Be Quoted Optionally.? Enclosed Assembly ( Ip 42 ) Guarantees Long Service Life, Should Incl. Protection Cover? Highly Polished Aluminium Heating Plate For Optimum Heat Transfer? The Device Shouldrestart Automatically After Power Goes Off And Comes Back And Also Saves The Last Setting For Longer Unsupervised Operation?Should Have Ce Certificate?Warranty : 3 Year , Water Bath - Double Walled Construction With Regular And Gmp Models.Outer & Inner:Sshole:12Working Temperature Oc:25 To 99Temperature Stability:+_0.3Temperature Display Resolution:0.1Safety Alarms : Dry Running Protectioncontroller:Pidwarranty:12Monthsbath Volume 20L Stainless Steel Cover With Concentric Rings.Temperature Digitally Controlled.Water Immersion Heaters.Working Size : 16 X 12 X 4 Holes : 12 Of 7.5 Cms Dia , Sonicator ( 1.5L ) - • Capacity 1.5L• Full Ss Body & Ss Tank• Digital Timer 0-30 / 0.99 Mins• Micro Controller Based Timer , • Tank Size :240 L X 135 B X 65H ( Mm ) • Operating Frequency 33 ±3 Khz, For All General Purpose Cleaning Is Highly Recommended. • Frequency Of 50 Khz Is Also Available•Input Voltage Range Of 170V Ac - 270V Ac, 50 Hz, L Ph.• Micro Controller Based Timer Range 0 To 15 Minutes Upto 1.5 Ltrs.• 30 / 99 Min. Timer Are Also Available.• Thermostatic Heating•Digital Temperature Controller , Heating Mental - For Flasks 250 Up To 1000 Ml.?? Spillproof–Stainless Steel Heater.?? Stepless– Heat Control.?? Operating Temp.: Up To 750°C.?? Includes 4 Support Rods And4 Clamps.?? Durable Housing Is Chemicallyresistant.?? Built-In Electronic Controllerregulates Element Temp. To750°C, 2 Ranges: Low & High.?? Robust Aluminium Constructionpermits Operation Of The Units Asrequired By Extraction Anddistillation Processes.?? “Heat On” Light For Each Recessindicates When Power Is Beingsupplied To The Heater.?? For Maximum Operatorprotection, Models Are Groundedshould Spillage Or Flask Breakageoccur.?? Units Are Designed With A Built-Instainless Steel Liner That Giveselectrical And Mechanicalprotection Against Spillage &Enables Easy Cleaning.?? Lower Profile For Space-Savingconvenience.?? Ideal For Repetitive Extracting ( Kjeldahl, Soxhlet, And Otherextraction Procedure ) , Refluxing &Distilling Laboratory Applications.?? Analog Controller Built-In System.?? Rods & Clamps Are Offered Asstandard.?? Ideal For All Brands Round Flasks.?? Highly-Processed Aluminiumcase Offers Robust Standing, Easy Handling. , Digital Abbe Refractometer - Measurement Range 1, 3000-1, 7200 Nd, 0-95 %Brixaccuracy ±0, 0002 Nd, ±0, 1 %Brixresolution 0, 0001 Nd, 0, 1 %Brixtemperature Range 0-99 °Ctemperature Resolution : 0, 1 °Cautom. Temperature Compensation: 0-90 °Cpower Supply 110 / 230 V, 50 / 60 Hz, 40 Wdimensions In Cm 12, 0 X 29, 0 X 25, 0 Weight 5 Kg? The Digital Abbe Refractometer Ar2008 With An Electronic Data Processing System.? The Refractive Index Or Brix Value Be Shown On An Lcd Display Together With The Temperature.? A Serial Interfacemeasuring Values With Date And Time To Be Transferred Directly To The Pc Or Printer.? An Automatic Temperature Compensation Feature? The Ar2008 With A Thermostat Connection For Prisms And A Built-In Light Source ( 589 Nm ) For The Measuring Prism.? Extremely Sturdy And Is Ideally Suited For Use In A Harsh Environment.? Supplied With A Glass Calibration Plate, Contact Fluid And A Screwdriver As Well As A Dust Hood. , Surface Tensiometer - Automatic Surface Tensiometer Liquid Interfacial Tension Meter With Platinum Plate And Platinum Ring Method 0 To 600Mn / M Range? Two Methods- Platinum Plate Method And Platinum Ring Method: In The Platinum Ring Method, The Value Displayed On The Screen Should Be Maximum Force Value. Size Of Platinum Ring: Radius Of Wire Is 0.185 Mm, Radius Of Ring Is 9.55Mm, Perimeter Of Ring Is 60 Mm.? Measuring Range: 0-600Mn / M Suitable For Measuring Liquid Containing Surfactant Or Volatile Substance And Sample Whose Surface Tension Will Change With Time.?Data Accuracy And Reliability: The Deviation Of The Instrument Should Be Very Low ? Simple Operating: One-Key Resetting And One-Key Calibrating Can Be Realized Rapidly And Exactly, Without Being Controlled By Any External Computer.? Lcd Display: In Platinum Plate Method, The Value Of Surface Tension Should Be Displayed In Real Time, And If Necessary, The Related Data Can Be Printed By A Printer Connected Through The Rs232 Interface Or Be Acquired By A Computer.? Data Display: In The Platinum Ring Method, Display Maximum Force, Excel Compatible Data Collection. , Microprocessor Flame Photometer - Range Na, K, Ca, Li 0-100Ppm Ba- 50 To 1000Ppmsensitivity: 0.5Ppmcurve Fit Accuracy: <2% Error When 3Ppm Na / K And 5Ppm Li Are Set As Maximum Standardsdisplay- Graphical Lcd With Backlitaverage Time-Inbuilt Software Flame System-Lpg And Dry Oil Free Airdetector-Silicon Photodiodecalibration-Upto 5-Point Calibration With Curve Fitting Softwaregas Control Adjustable With Knobs, Auto Ignition, Axial Flow Typeusb Port, 230V +-10%Ac. 50Hzair Supply-By Oil Free Mini Compressor Unit With Pressure Regulatorcombustion: Gas Lpg Controlled By Precision Regulator , Hydrothermal Auto Clave - Technical Specification Datasheetproduct Name: Hydrothermal Autoclaveproduct Series: Autoclave-Ptfeproperties: Safe Temperature: 200°C Maximum Operating Temperature - 220°C Working Pressure: = 3Mpa Heating And Cooling Rate: = 5°C / Min Material: Shell Made Of High-Quality Stainless Steel ( Ss-316 ) Inner Ptfe ( Teflon Liner ) Chambercapacity500ml Total Quantity : 1

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Nov-2021 25-Nov-2021

BOQ

Sl. No. Item TitleItem Description
1LCD Digital Magnetic Hotplate Stirrer with Timer? Heating temperature range of RT to 300° C with hating power of 550 W or more.? Integrated temperature control with Incl. PT 1000 temperature sensor.? Digital LED display for both speed and set and actual temperature of medium.? Maximum stirring quantity should be 15 L or more with speed range of 50-1500 rpm.? Adjustable safety temperature limits (50 - 360 °C) for avoiding flash points of medium.? Hot Top indicator >> hot surface warning to prevent burns!? Digital error code display.? Bushing according to DIN 12878 for connecting a contact thermometer with capacity to control medium temperature with accuracy of ±0.2 K and measure the pH of solution by connecting an external pH electrode and should be quoted optionally.? Enclosed assembly (IP 42) guarantees long service life, Should Incl. protection cover? Highly polished aluminium heating plate for optimum heat transfer? The device shouldrestart automatically after power goes off and comes back and also saves the last setting for longer unsupervised operation?Should have CE certificate?Warranty : 3 Year
2Water bathDouble walled Construction with regular and GMP models.Outer & inner:SSHole:12Working Temperature oC:25 to 99Temperature stability:+_0.3Temperature display resolution:0.1Safety alarms : Dry running protectionController:PIDWarranty:12monthsBath volume 20L Stainless steel cover with concentric rings.Temperature digitally controlled.Water immersion heaters.Working size : 16\" x 12\" x 4\" Holes : 12 of 7.5 cms dia
3Sonicator (1.5L)• Capacity 1.5L• Full ss Body & SS Tank• Digital Timer 0-30 / 0.99 mins• Micro controller based timer ,• Tank size :240 L X 135 B X 65H (mm )• Operating frequency 33 ±3 KHz, for all general purpose cleaning is highly recommended. • Frequency of 50 KHz is also available•Input voltage range of 170V AC - 270V AC, 50 Hz, l Ph.• Micro controller based timer range 0 to 15 minutes upto 1.5 ltrs.• 30/99 min. timer are also available.• Thermostatic heating•Digital Temperature Controller
4Heating MentalFor flasks 250 up to 1000 ml.?? Spillproof–Stainless Steel Heater.?? Stepless– heat control.?? Operating temp.: up to 750°C.?? Includes 4 support rods and4 clamps.?? Durable housing is chemicallyresistant.?? Built-in electronic controllerregulates element temp. to750°C, 2 ranges: low & high.?? Robust aluminium constructionpermits operation of the units asrequired by extraction anddistillation processes.?? “Heat on” light for each recessindicates when power is beingsupplied to the heater.?? For maximum operatorprotection, models are groundedshould spillage or flask breakageoccur.?? Units are designed with a built-instainless steel liner that giveselectrical and mechanicalprotection against spillage &enables easy cleaning.?? Lower profile for space-savingconvenience.?? Ideal for repetitive extracting(kjeldahl, soxhlet, and otherextraction procedure), refluxing &distilling laboratory applications.?? Analog controller built-in system.?? Rods & clamps are offered asstandard.?? Ideal for all brands round flasks.?? Highly-processed aluminiumcase offers robust standing,easy handling.
5Digital Abbe RefractometerMeasurement range 1,3000-1,7200 nD, 0-95 %BrixAccuracy ±0,0002 nD, ±0,1 %BrixResolution 0,0001 nD, 0,1 %BrixTemperature Range 0-99 °CTemperature resolution : 0,1 °CAutom. Temperature compensation: 0-90 °CPower supply 110/230 V, 50/60 Hz, 40 WDimensions in cm 12,0 x 29,0 x 25,0 Weight 5 kg? The digital Abbe refractometer AR2008 with an electronic data processing system.? The refractive index or Brix value be shown on an LCD display together with the temperature.? A serial interfacemeasuring values with date and time to be transferred directly to the PC or printer.? An automatic temperature compensation feature? The AR2008 with a thermostat connection for prisms and a built-in light source (589 nm) for the measuring prism.? Extremely sturdy and is ideally suited for use in a harsh environment.? Supplied with a glass calibration plate, contact fluid and a screwdriver as well as a dust hood.
6Surface TensiometerAutomatic Surface Tensiometer Liquid Interfacial Tension Meter With Platinum Plate and Platinum Ring Method 0 to 600mN/m Range? Two methods- Platinum Plate Method and Platinum Ring Method: In the platinum ring method, the value displayed on the screen should be maximum force value. Size of platinum ring: radius of wire is 0.185 mm, radius of ring is 9.55mm, perimeter of ring is 60 mm.? Measuring range: 0-600mN/m suitable for measuring liquid containing surfactant or volatile substance and sample whose surface tension will change with time.?Data Accuracy and Reliability: The deviation of the instrument should be very low ? Simple Operating: One-key resetting and One-key calibrating can be realized rapidly and exactly, without being controlled by any external computer.? LCD Display: In Platinum Plate Method, the value of surface tension should be displayed in real time, and if necessary, the related data can be printed by a printer connected through the RS232 interface or be acquired by a computer.? Data Display: In the platinum ring method, display maximum force, excel compatible data collection.
7Microprocessor Flame PhotometerRange Na, K, Ca, Li 0-100ppm Ba- 50 to 1000ppmSensitivity: 0.5ppmCurve fit accuracy: <2% error when 3ppm Na/K and 5ppm Li are set as maximum standardsDisplay- Graphical LCD with backlitAverage Time-inbuilt software Flame system-LPG and dry oil free airDetector-Silicon photodiodeCalibration-upto 5-point calibration with curve fitting softwareGas control adjustable with knobs, auto ignition, axial flow typeUSB port, 230V +-10%AC. 50HzAir supply-By oil free mini compressor unit with pressure regulatorCombustion: Gas LPG controlled by precision regulator
8Hydrothermal Auto claveTechnical Specification DatasheetProduct Name: Hydrothermal AutoclaveProduct Series: AUTOCLAVE-PTFEProperties: Safe Temperature: 200°C Maximum Operating Temperature - 220°C Working Pressure: = 3MPa Heating and Cooling Rate: = 5°C/min Material: Shell made of high-quality stainless steel (SS-316) Inner PTFE (Teflon Liner) ChamberCapacity500mL

AI Tender Summary

OUR REF NO 29787193
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 7.75 Lakhs
LAST DATE 25-11-2021
Authority
Authority Name Islamic University Of Science And Technology
Work Description Bids Are Invited For Lcd Digital Magnetic Hotplate Stirrer With Timer - ? Heating Temperature Range Of Rt To 300° C With Hating Power Of 550 W Or More.? Integrated Temperature Control With Incl. Pt 1000 Temperature Sensor.? Digital Led Display For Both Speed And Set And Actual Temperature Of Medium.? Maximum Stirring Quantity Should Be 15 L Or More With Speed Range Of 50-1500 Rpm.? Adjustable Safety Temperature Limits ( 50 - 360 °C ) For Avoiding Flash Points Of Medium.? Hot Top Indicator >> Hot Surface Warning To Prevent Burns!? Digital Error Code Display.? Bushing According To Din 12878 For Connecting A Contact Thermometer With Capacity To Control Medium Temperature With Accuracy Of ±0.2 K And Measure The Ph Of Solution By Connecting An External Ph Electrode And Should Be Quoted Optionally.? Enclosed Assembly ( Ip 42 ) Guarantees Long Service Life, Should Incl. Protection Cover? Highly Polished Aluminium Heating Plate For Optimum Heat Transfer? The Device Shouldrestart Automatically After Power Goes Off And Comes Back And Also Saves The Last Setting For Longer Unsupervised Operation?Should Have Ce Certificate?Warranty : 3 Year , Water Bath - Double Walled Construction With Regular And Gmp Models.Outer & Inner:Sshole:12Working Temperature Oc:25 To 99Temperature Stability:+_0.3Temperature Display Resolution:0.1Safety Alarms : Dry Running Protectioncontroller:Pidwarranty:12Monthsbath Volume 20L Stainless Steel Cover With Concentric Rings.Temperature Digitally Controlled.Water Immersion Heaters.Working Size : 16 X 12 X 4 Holes : 12 Of 7.5 Cms Dia , Sonicator ( 1.5L ) - • Capacity 1.5L• Full Ss Body & Ss Tank• Digital Timer 0-30 / 0.99 Mins• Micro Controller Based Timer , • Tank Size :240 L X 135 B X 65H ( Mm ) • Operating Frequency 33 ±3 Khz, For All General Purpose Cleaning Is Highly Recommended. • Frequency Of 50 Khz Is Also Available•Input Voltage Range Of 170V Ac - 270V Ac, 50 Hz, L Ph.• Micro Controller Based Timer Range 0 To 15 Minutes Upto 1.5 Ltrs.• 30 / 99 Min. Timer Are Also Available.• Thermostatic Heating•Digital Temperature Controller , Heating Mental - For Flasks 250 Up To 1000 Ml.?? Spillproof–Stainless Steel Heater.?? Stepless– Heat Control.?? Operating Temp.: Up To 750°C.?? Includes 4 Support Rods And4 Clamps.?? Durable Housing Is Chemicallyresistant.?? Built-In Electronic Controllerregulates Element Temp. To750°C, 2 Ranges: Low & High.?? Robust Aluminium Constructionpermits Operation Of The Units Asrequired By Extraction Anddistillation Processes.?? “Heat On” Light For Each Recessindicates When Power Is Beingsupplied To The Heater.?? For Maximum Operatorprotection, Models Are Groundedshould Spillage Or Flask Breakageoccur.?? Units Are Designed With A Built-Instainless Steel Liner That Giveselectrical And Mechanicalprotection Against Spillage &Enables Easy Cleaning.?? Lower Profile For Space-Savingconvenience.?? Ideal For Repetitive Extracting ( Kjeldahl, Soxhlet, And Otherextraction Procedure ) , Refluxing &Distilling Laboratory Applications.?? Analog Controller Built-In System.?? Rods & Clamps Are Offered Asstandard.?? Ideal For All Brands Round Flasks.?? Highly-Processed Aluminiumcase Offers Robust Standing, Easy Handling. , Digital Abbe Refractometer - Measurement Range 1, 3000-1, 7200 Nd, 0-95 %Brixaccuracy ±0, 0002 Nd, ±0, 1 %Brixresolution 0, 0001 Nd, 0, 1 %Brixtemperature Range 0-99 °Ctemperature Resolution : 0, 1 °Cautom. Temperature Compensation: 0-90 °Cpower Supply 110 / 230 V, 50 / 60 Hz, 40 Wdimensions In Cm 12, 0 X 29, 0 X 25, 0 Weight 5 Kg? The Digital Abbe Refractometer Ar2008 With An Electronic Data Processing System.? The Refractive Index Or Brix Value Be Shown On An Lcd Display Together With The Temperature.? A Serial Interfacemeasuring Values With Date And Time To Be Transferred Directly To The Pc Or Printer.? An Automatic Temperature Compensation Feature? The Ar2008 With A Thermostat Connection For Prisms And A Built-In Light Source ( 589 Nm ) For The Measuring Prism.? Extremely Sturdy And Is Ideally Suited For Use In A Harsh Environment.? Supplied With A Glass Calibration Plate, Contact Fluid And A Screwdriver As Well As A Dust Hood. , Surface Tensiometer - Automatic Surface Tensiometer Liquid Interfacial Tension Meter With Platinum Plate And Platinum Ring Method 0 To 600Mn / M Range? Two Methods- Platinum Plate Method And Platinum Ring Method: In The Platinum Ring Method, The Value Displayed On The Screen Should Be Maximum Force Value. Size Of Platinum Ring: Radius Of Wire Is 0.185 Mm, Radius Of Ring Is 9.55Mm, Perimeter Of Ring Is 60 Mm.? Measuring Range: 0-600Mn / M Suitable For Measuring Liquid Containing Surfactant Or Volatile Substance And Sample Whose Surface Tension Will Change With Time.?Data Accuracy And Reliability: The Deviation Of The Instrument Should Be Very Low ? Simple Operating: One-Key Resetting And One-Key Calibrating Can Be Realized Rapidly And Exactly, Without Being Controlled By Any External Computer.? Lcd Display: In Platinum Plate Method, The Value Of Surface Tension Should Be Displayed In Real Time, And If Necessary, The Related Data Can Be Printed By A Printer Connected Through The Rs232 Interface Or Be Acquired By A Computer.? Data Display: In The Platinum Ring Method, Display Maximum Force, Excel Compatible Data Collection. , Microprocessor Flame Photometer - Range Na, K, Ca, Li 0-100Ppm Ba- 50 To 1000Ppmsensitivity: 0.5Ppmcurve Fit Accuracy: <2% Error When 3Ppm Na / K And 5Ppm Li Are Set As Maximum Standardsdisplay- Graphical Lcd With Backlitaverage Time-Inbuilt Software Flame System-Lpg And Dry Oil Free Airdetector-Silicon Photodiodecalibration-Upto 5-Point Calibration With Curve Fitting Softwaregas Control Adjustable With Knobs, Auto Ignition, Axial Flow Typeusb Port, 230V +-10%Ac. 50Hzair Supply-By Oil Free Mini Compressor Unit With Pressure Regulatorcombustion: Gas Lpg Controlled By Precision Regulator , Hydrothermal Auto Clave - Technical Specification Datasheetproduct Name: Hydrothermal Autoclaveproduct Series: Autoclave-Ptfeproperties: Safe Temperature: 200°C Maximum Operating Temperature - 220°C Working Pressure: = 3Mpa Heating And Cooling Rate: = 5°C / Min Material: Shell Made Of High-Quality Stainless Steel ( Ss-316 ) Inner Ptfe ( Teflon Liner ) Chambercapacity500ml Total Quantity : 1
Basic Detail
Tender No GEM/2021/B/1645558
Bidding Type Tender
Location
City
State Jammu And Kashmir
Key Dates
Publish Date 17 Nov 2021
Submission Date 25 Nov 2021
Open Date 25 Nov 2021
Finance
Tender Value 7.75 Lakhs
Tender Fee Ref. Documents
EMD 23250
Exemption Not Available
Document List
2816367_Boq_2.xlsx
d7cc7854-e966-45d8-9bf1-e827eeb49687.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 25, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 25, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xlsx

2816367_Boq_2.xlsx

pdf

d7cc7854-e966-45d8-9bf1-e827eeb49687.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders