Balance Electric Work Of Faculty Block Ist Floor At Skims Mch Bemina- 1 Providing, Fixing Of Fresh Lighting Point ( 5-6 Amp ) Exposed, Using Pvcin Double Locked Pvcchannel 25X1.6 Mm Thick And Partly Inpvc Conduit 1 Dia 1.5 Mm Thick With Accessories, SKIMS MCH Bemina-Jammu And Kashmir

Rural Development and Panchayat Raj Department has published Balance Electric Work Of Faculty Block Ist Floor At Skims Mch Bemina- 1 Providing, Fixing Of Fresh Lighting Point ( 5-6 Amp ) Exposed, Using Pvcin Double Locked Pvcchannel 25X1.6 Mm Thick And Partly Inpvc Conduit 1 Dia 1.5 Mm Thick With Accessories. Submission Date for this Tender is 15-12-2021. Coats and Jackets Tenders in SKIMS MCH Bemina Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

29778815
Corrigendum : Balance Electric Work Of Faculty Block Ist Floor At Skims Mch Bemina- 1 Providing, Fixing Of Fresh Lighting Point ( 5-6 Amp ) Exposed, Using Pvcin Double Locked Pvcchannel 25X1.6 Mm Thick And Partly Inpvc Conduit 1 Dia 1.5 Mm Thick With Accessories
Open Tender
Indian
Jammu And Kashmir
SKIMS MCH Bemina
15-12-2021

Tender Details

Balance Electric Work Of Faculty Block Ist Floor At Skims Mch Bemina- 1 Providing, Fixing Of Fresh Lighting Point ( 5-6 Amp ) Exposed, Using Pvcin Double Locked Pvcchannel 25X1.6 Mm Thick And Partly Inpvc Conduit 1 Dia 1.5 Mm Thick With Accessories To Be Fixed On The Surface Of The Wall With Rowel Plugs, Saddles, Screws, Using Multi-Strand 3 X1.5 Mm Sq. Pvc Insulated Copper Wire ( P+N+E ) ( Havells / Finolex / Polycab / Paramount Make Fr ) Complete With P / F Of Switch 5 / 6 Amps F / T ( Ssk / HavellS Reo Make ) To Be Fitted On 3Mm Bakelite Sheet Suitable Size, M.S / Wooden Box, Rowel Plugs & Screws Etc. Complete Point Lght, Fans And 6A Socket Out Let. 2 Wiring To Be Carried Out For Fresh Heating Point In Surface Manner Through Pvc Conduitof 25 Dia.2 Mm Thick And Partly In Pvc Channel 25X1.6 Mm Thickusing Multi Strand 3 X 2.5 Mm.Sqpvc Insulated Copper Wire ( Havells / Finolex / Polycab / Paramount Make Fr ) Complete With P / F Of Switch Socket Combine 15 / 16 Amps 5 Pin F / Tssk / HavellS Make To Be Fitted On Bakelite Sheet Suitable Size, M.S / Wooden Box, Rowel Plugs & Screws Etc. Complete Point With Civil Work ( Normal Poer Points And Dg Power Points ) . 3 Wiring To Be Carried Out For 16 A Power Point Using 4 Mm Sq. ( P+N+E ) Pvc Insulated Copper Conductor Single Core Cable ( Is Marked ) Through Pvc Conduit 1 1.5 Mm Thick With Accessories In Surface / Recessed Manner Required ( Excluding The Cost Of Switch Socket Combine 15 / 16 A & Pvc Pipefor 20 Heating Points. 4 Circuit Wire To Be Laid / Replacement Of Damaged Wire As Per Site Requirements Using Multi Strand Pvc Insulated Copper Wire ( Excluding The Cost Of Conduit ) 5 A ) 2.5 Mm² Multi Strand Pvc Insulated Copper. 6 B ) 6Mm 2Multi Strand Pvc Insulated Copper 7 C ) 16Mm 2Multi Strand Pvc Insulated Copper 8 A ) P / F Ofpvc Conduit 25 Mmdia 2 Mm Thick Ain Concealed Mannerfor Laying Of Circuit Wireitem No 3.4 9 P / F Of Led4feet Long Batten 6000 / 6500K Light Having Extruded Aluminium Heat Sink With Anti-Glare Diffuser With Energy Efficient Electronic Drivercri Greater Than 80 With Minimum Sytem Lumens 2000 And Maximum Wattage 22 Including Connection With Multistrand Copper Conductor 3 Core Cable Etc As Required At Site. 10 P / F Of Led2feet Long Batten 6000 / 6500K Light Having Extruded Aluminium Heat Sink With Anti-Glare Diffuser With Energy Efficient Electronic Drivercri Greater Than 80 With Minimum Sytem Lumens 1000 And Maximum Wattage 10 Including Connection With Multistrand Copper Conductor 3 Core Cable Etc As Required At Site. 11 Supply, Installation, Testing And Commissioning Of Cieling Fan 1200 Mm Sweep, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374- 2019 ) , Thd Less Than 10%, Controlled Byelectronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc.Complete As Required. 12 Providing And Fixing Of Fan Hooks Of Suitable Size Complete As Required. 13 Provinding And Fixing Of Fan Regulater Stepped Type One Way Complete As Required 14 P / Installation Of Exhaust Fans 250 Mm Plastic Shutter Type ( Isi Marked ) . 15 Providing And Fixing Of Ply Board12 Mm Thick Suitable Size For Above Mentioned Exhaust Fans With Central Holes & Screws Etc. Complete With Civil Work 16 P / F Of Bakelite / Phenolic Laminated Sheet 3 Mm Thick For Fixing Of S.S Comb.15 / 16 A Socket Outlet And Inspection Boxes / Computer System.. 17 Supply , Installation Testing & Commissioningof Fresh Geyser 50 Liters Alongwith Foundation Bolts, Top, Lead And Pvc Connection. 18 Supply , Installation Testing & Commissioningof Fresh Geyser 35 Liters Alongwith Foundation Bolts, Top, Lead And Pvc Connection. 19 Supplying And Fixing Tpn 6 Way, Single Pole And Neutral, Sheetsteel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Tinned Copper Insulated Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc.As Required.In Wards And Rooms . 20 Supplying And Fixing Following Rating, 240 / 415 Volts, “C”Curve, 10Ka Miniature Circuit Breaker Suitable For Inductive Load Themcb Db Should Be Complete With Connections, Testing And Commissioning Etc. As Required. 21 A ) P / F Of Mcb Tpn 63A240 / 415 VoltsC Curve 10 Kaas Main To Be Fixed In Above Mentioned Db. 22 B ) P / F Of Mcb Sp 10A 32A For Lighting And Heating Points In Existing Db For Above Two Rooms . 23 C ) P / F Of Rccbs 63A With Sensitivity Of 300 Ma240 / 415 Volts To Be Fixed In Above Mentioned DbS. For Heatingcircuits 24 Providing And Fixing 100Amps With 25 Ka Breaking Capacityfour Pole Mccbincluding Drilling Holes In Mccb Enclosure, Making Connections, Etc. As Required.. 25 A ) Providing And Fixing Sheet Steel Mccb Enclosure Suitable For 100 Amps, 25 Ka Breaking Capacity Four Pole Mccb Complete With Lockable Door, Dust / Vermin Proof, Hinged Type, Cable Entry Houles And Power Coated Painted. 26 P / F Of Tpn Bus Bar 100 A4way Wall Mounted ( Industrialswitch Gear Busbar Chamber ) 27 Providing And Laying Of Spans Of 70 Mm Sq. 3.5 Core Xlpe / Pvc Insulated Al. Cable Armoured From 200 A Main Bus Bar Of Ground Floor Faculty Block To Sub Db Of First Floor Faculty Blockon Wall 28 Fixing Of One Number Pvcinsulated And Pvc Sheated / Xlpe Power Cable Of 1.1 Kv Grade Of Above Mentioned On Wall 29 Providing And Making Of End Termination Of The 70 Mm Sq. 3.5 Core Lt Cable Including Thimbling , Crimping, Tapping , Testing & Connecting At Site. 30 Making Of Earth Points Includes Salt Charcoalgi Plate Size Gi 600 Mm X 600X5mmpit Should Be Dug 3 Mtr From The Surface And Providing And Fixing Gi Strip ( 25 Mmx 5Mm ) In 40 Mm Dia Gi . The Job Also Includes Providing & Laying Of Separate 40 Mm Gi Watering Pipe To The Plate Complete As Per Latest Specification 31 P / Laying Of 25 Mmx 5 Mm G.I Earthing Strips Including Nut , Bolts From Existing Earth Point Upto Db As Per Site Requirement 32 Providing And Fixing Of Switch5 / 6 A Ft / T For System 33 Providing And Fixing Of Switch Socket 5 / 6 A 5 Pin 5 Pin For System

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Nov-2021 Date Extension Date 22-11-2021
2 24-Nov-2021 Date Extension II Date 29-11-2021
3 01-Dec-2021 Date Extension III Date 06-12-2021
4 08-Dec-2021 Extension Date 15-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 8900.0 /-
Tender Value
INR 4.45 Lakhs /-

BOQ Items

Name of Work: Balance Electric work of Faculty blockIst floor atSKIMS MCH Bemina
Sl. No. Item Description
1Providing, fixing of fresh lighting point (5-6 amp) exposed,using PVCin double locked PVCchannel 25x1.6 mm thick and partly inPVC conduit 1" dia 1.5 mm thick with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 3 x1.5 mm sq. pvc insulated copper wire (P+N+E) (Havells/Finolex/ Polycab/Paramount make FR)complete with P/F of switch 5/6 amps F/T (SSK/Havell"s Reo make) to be fitted on 3mm Bakelite sheet suitable size,M.S/Wooden box, rowel plugs & screws etc. complete Point Lght, fans and 6A socket out let.
2Wiring to be carried out for fresh heating point in surface manner through pvc conduitof 25 dia.2 mm thick and partly in pvc channel 25x1.6 mm thickusing multi strand 3 x 2.5 mm.sqpvc insulated copper wire (Havells/Finolex/ Polycab/Paramount make FR) complete with P/F of switch socket combine 15/16 amps 5 pin F/TSSK/Havell"s make to be fitted on Bakelite sheet suitable size, M.S/Wooden box, rowel plugs & screws etc. complete Point with civil work ( Normal poer points and DG power points).
3Wiring to be carried out for 16 A power point using 4 mm sq. (P+N+E) PVC insulated copper conductor single core cable (IS marked) through PVC conduit 1" 1.5 mm thick with accessories in surface /recessed manner required (excluding the cost of switch socket combine 15/16 A & PVC pipefor 20 heating points.
4Circuit wire to be laid / Replacement of damaged wire as per site requirements using multi strand pvc insulated copper wire(excluding the cost of conduit)
5a) 2.5 mm² multi strand pvc insulated copper.
6b) 6mm 2multi strand pvc insulated copper
7c) 16mm 2multi strand pvc insulated copper
8a) P/F ofPVC conduit 25 mmdia 2 mm thick ain concealed mannerfor laying of circuit wireitem no 3.4
9P/F of Led4feet long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driverCRI greater than 80 with minimum sytem lumens 2000 and maximum wattage 22 including connection with multistrand copper conductor 3 core cable etc as required at site.
10P/F of Led2feet long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driverCRI greater than 80 with minimum sytem lumens 1000 and maximum wattage 10 including connection with multistrand copper conductor 3 core cable etc as required at site.
11Supply, Installation, Testing and Commissioning of Cieling Fan 1200 mm sweep,class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, controlled byelectronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
12Providing and fixing of Fan hooks of suitable size complete as required.
13provinding and fixing of Fan regulater stepped type one way complete as required
14P/installation of Exhaust fans 250 mm plastic Shutter type (ISI marked).
15providing and fixing of Ply board12 mm thick suitable size for above mentioned exhaust fans with central holes & screws etc. complete with civil work
16P/f of bakelite /Phenolic Laminated Sheet 3 mm thick for fixing of S.S comb.15/16 A socket outlet and inspection boxes/computer system..
17Supply ,Installation testing & commissioningof fresh Geyser 50 liters alongwith foundation bolts, top,lead and pvc connection.
18Supply ,Installation testing & commissioningof fresh Geyser 35 liters alongwith foundation bolts, top,lead and pvc connection.
19Supplying and fixing TPN 6 way, single pole and neutral, sheetsteel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper insulated bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required.in wards and rooms .
20Supplying and fixing following rating, 240/415 volts, “C”curve,10KA miniature circuit breaker suitable for inductive load theMCB DB should be complete with connections, testing and commissioning etc. as required.
21a) P/F of MCB TPN 63A240 /415 volts"C" curve 10 KAas main to be fixed in above mentioned DB.
22b) P/F of MCB SP 10A 32A for lighting and heating points in existing DB for above two rooms .
23c) P/F of RCCBs 63A with sensitivity of 300 MA240/415 volts to be fixed in above mentioned DB"s. For heatingcircuits
24Providing and fixing 100amps with 25 KA breaking capacityFour pole MCCBincluding drilling holes in MCCB enclosure, making connections, etc. as required..
25a) Providing and fixing sheet steel MCCB enclosure suitable for 100 amps,25 KA breaking capacity Four pole MCCB complete with lockable door, dust/vermin proof, hinged type, cable entry houles and power coated painted.
26P/f of TPN Bus bar 100 A4way wall mounted (industrialswitch gear busbar chamber)
27Providing and laying of spans of 70 mm sq. 3.5 core XLPE/PVC insulated Al. cable armoured from 200 A main Bus Bar of ground floor faculty block to sub DB of first floor faculty blockon wall
28Fixing of one number pVCinsulated and PVC sheated /XLPE power cable of 1.1 KV grade of above mentioned on wall
29Providing and making of End Termination of the 70 mm Sq. 3.5 core LT cable including thimbling ,crimping, tapping ,testing & connecting at Site.
30Making of earth points includes salt charcoalGI plate size GI 600 mm x 600x5mmpit should be dug 3 mtr from the surface and providing and fixing GI strip (25 mmx 5mm) in 40 mm dia GI . The job also includes providing & laying of separate 40 mm GI watering Pipe to the plate complete as per latest specification
31P/Laying of 25 mmx 5 mm G.I earthing strips including nut ,bolts from existing earth point upto DB as per site requirement
32Providing and fixing of Switch5/6 A FT/T for system
33Providing and fixing of Switch socket 5/6 A 5 pin 5 pin for system