}

Repair Maint Of Centrifugal Submersible Pump Sets Motors Starters And Cleaning Of Ug Sumps Storage Sumps Filters Of Water Supply Installation At Leimakhong Mil Stn Repair Maint Of Centrifugal Submersible Pump Sets Motors Starters And Cleaning Of Ug Sump, LEIMAKHONG-Manipur

Military Engineer Services-MES has published Repair Maint Of Centrifugal Submersible Pump Sets Motors Starters And Cleaning Of Ug Sumps Storage Sumps Filters Of Water Supply Installation At Leimakhong Mil Stn Repair Maint Of Centrifugal Submersible Pump Sets Motors Starters And Cleaning Of Ug Sump. Submission Date for this Tender is 29-11-2021. Starter Tenders in LEIMAKHONG Manipur. Bidders can get complete Tender details and download the document.




Tender Notice

29754940
Corrigendum : Repair Maint Of Centrifugal Submersible Pump Sets Motors Starters And Cleaning Of Ug Sumps Storage Sumps Filters Of Water Supply Installation At Leimakhong Mil Stn Repair Maint Of Centrifugal Submersible Pump Sets Motors Starters And Cleaning Of Ug Sump
Open Tender
Indian
Manipur
LEIMAKHONG
29-11-2021

Tender Details

Repair Maint Of Centrifugal Submersible Pump Sets Motors Starters And Cleaning Of Ug Sumps Storage Sumps Filters Of Water Supply Installation At Leimakhong Mil Stn Repair Maint Of Centrifugal Submersible Pump Sets Motors Starters And Cleaning Of Ug Sumps Storage Sumps Filters Of Water Supply Installation At Leimakhong Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Nov-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-11-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT OF CENTRIFUGAL PUMP SETS, MOTORS, STARTERS AND CLEANING OF UG SUMP, STORAGE SUMP, FILTER OF WATER SUPPLY INSTALLATION AT LEIMAKHONG MIL STN
Sl. No. Item Description
1B/R work
2Taking out old filter media of different grades/sizes of pressure filters one by one in layer and laying out manually including segregating useful materials etc complete all as specified and directed
3Cleaning & washing of old serviceable filter media of different grades (taken out under item No 2.00 here-in-before) and repacking the retrieved/cleaned media in different layers complete all as specified and directed
4M&L for new filter media/ferrimanex and repacking in different layers, sand of 16/30 mesh complete all as specified and directed.
5M&L for cleaning of inner surfaces of RCC under ground sump / semi under ground sump including floor of water intake sump and applying two coats of white wash after taking out and removing silt, sludge, moss, algae, dirt etc. complete all as specified and directed upto the entire satisfaction of Engineer-in-charge for the following :
6Semi under ground sump of capacity 75000 Gallon at High Lift Pump House
7Semi under ground sump of capacity 50000 Gallon at High Lift Pump House.
8Semi under ground sump of capacity 50000 Gallon Near Capt Qtr (High Lift Pump House) & KLP Pump House.
9Semi under ground sump of capacity 25000 Gallon at High Lift pump house-01, KLP pump house-01
10Semi under ground sump of capacity 6400 Gallon at High Lift Pump house.
11Semi under ground sump open type of capacity 50000 Gallon at Low Lift Pump house.
12Semi under ground sump open type of capacity 10000 Gallon at Low Lift Pump house.
13NOTE :(Applicable for Sl iterm No 5.01 to 5.07) (i) The unit rate quoted shall bedeemed to include draining of water with mechanical equipment and working in water and mud etc. (ii) The unit rate quoted shall be deemed toinclude all safety precautions which shall be taken while working on RCC underground sump/semi under ground sump. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that shall be deemed to be inclusive in the unit rate and electricity / diesel shall not be provided by the Department. (iv) Contractor will not be allowed more than one day to complete the work insideeach UG sump to prevent interruption of water supply to the users. (v)The date of cleaning and due date of cleaning must be painted with synthetic enamel paint on the out side of the front tank wall as specified and directed by Engr-in-Charge
14Dismantling and strip opening of pumps completely including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refitting/ re-assembling & connecting the same and testing of pumps complete all as specified and directed for the following capacities:- Note : (i) The rate considered is inclusive of T&P required for carrying out the repairs. (ii)The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables.(iii)The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv)The cost of spares for pump considered separately under appropriate items here-in-after. (v) The rate considered are inclusive of transporting the pumps to Wksp and back to installation site.
15Pump capacity 100 HP
16Pump capacity 60 HP
17Pump capacity 50 HP
18Pump capacity 20 HP
19Pump capacity 15 HP
20Pump capacity 7.5 HP
21Supply only the following spares for pump sets of capacity 100HP/60HP/50HP (Note: Make of spares shall be of the original make of the pump)
22Pump Shaft
23Bronze impeller 1st stage
24Bronze impeller 2nd stage
25Wear ring Bronze
26Inter stage ring Bronze
27Water deflector rubber
28Bearing cartridge cast iron drive end
29Bearing cartridge cast iron non drive end
30Shaft sleeve bronze drive end
31Shaft sleeve bronze non drive end
32Spacer sleeve drive end
33Spacer sleeve non drive end
34Key for impeller and sleeve
35Bearing lock nut
36Stuffing box bush
37O" ring for shaft sleeve
38Cast iron gland (Set of 2 halves)
39Eye bolt for gland with nut and washer
40Gland guide bush large
41Gland guide bush small
42Center link bush
43Check nut
44Shaft Pulley
45Supply only the following spares for pump sets of capacity 20HP/15HP (Note: Make of spares shall be of the original make of the pump)
46Pump Shaft
47Impeller
48Casing wear ring
49Casing cover
50Lantern ring
51Gland collar
52Liquid deflector
53Bearing housing
54Support foot
55Bearing cover
56Shaft sleeve
57Key for impeller
58Key for coupling
59Impeller nut
60Washer for impeller
61Gland packing
62Grease Nipple
63Gasket for casing cover
64Gasket for shaft sleeve and shaft
65O" ring for sleeves & impeller
66Tie rod
67Supply only the following spares for pump sets of capacity 7.5HP (Note: Make of spares shall be of the original make of the pump)
68Pump Shaft
69Impeller
70Rotor
71Spacer
72Gland Collar
73Lantern ring
74Water deflector
75Shaft Sleeve
76Key for impeller
77Gland packing
78Priming plug
79Washer for impeller nut
80Gasket for casing cover
81split cotter Pin
82Supply only Ball bearing/Roller bearing for the following pumpsets: (Make: SKF/FAG/Rolon/NRB)
83Pump Capacity 100HP
84Pump Capacity 60HP
85Pump Capacity 50HP
86Pump Capacity 20HP
87Pump Capacity 15HP
88Pump Capacity 7.5HP
89Supply only drive end bearing for the following pumpsets: (Make: SKF/FAG/Rolon/NRB)
90Pump Capacity 100HP
91Pump Capacity 60HP
92Pump Capacity 50HP
93Pump Capacity 20HP
94Pump Capacity 15HP
95Pump Capacity 7.5HP
96Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Note : (i)The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii)The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii)The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting.(iv) The rate considered are inclusive of transporting the motors to Wksp and back.(v)The cost of spares for pump considered separately under appropriate items here-in-after.
97Motor capacity 100HP
98Motor capacity 60HP
99Motor capacity 50HP
100Motor capacity 20HP
101Motor capacity 15HP
102Motor capacity 7.5HP
103Motor capacity 5HP
104Motor capacity 3HP
105Motor capacity 1HP
106Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelledcopper winding wire complete including varnishing and heating all as specified anddirected of the following sizes:
107Electric motor, 3 phase 100 HP capacity
108Electric motor, 3 phase 60 HP capacity
109Electric motor, 3 phase 50 HP capacity
110Electric motor20 HP capacity
111Electric motor15 HP capacity
112Submersible Electric motor7.5 HP capacity
113Electric motor5 HP capacity
114Electric motor3 HP capacity
115Electric motor of pressure pump 1 HP capacity
116Supply only ball bearing/ roller bearing (Non drive end bearing) for the following electric motor. (Make: SKF/FAG/Rolon/NRB)
117Electric motor, 3 phase 100 HP capacity
118Electric motor, 3 phase 60 HP capacity
119Electric motor, 3 phase 50 HP capacity
120Electric motor20 HP capacity
121Electric motor15 HP capacity
122Electric submersible motor7.5 HP capacity
123Electric motor5 HP capacity
124Electric motor3 HP capacity
125Supply only ball bearing/ roller bearing (Drive end bearing) for the following electric motor. (Make: SKF/FAG/Rolon/NRB)
126Electric motor, 3 phase 100 HP capacity
127Electric motor, 3 phase 60 HP capacity
128Electric motor, 3 phase 50 HP capacity
129Electric motor20 HP capacity
130Electric motor15 HP capacity
131Electric Submersible motor7.5 HP capacity
132Electric motor5 HP capacity
133S&F rubber coupling high speed PHF 110 suitable for centrifugal pumpset
134M & Lfor painting of pump set of capacity 15HP to 100HP, including connected starter inside pump house with two coats of anti corrosive synthetic enamel paint over a coat of red oxide primeras per existing colour after preparation of old painted surfaces complete all as specified and directed.
135Testing of water for potability test by chemical and bacteriological from any Govt. laboratory such as PH value, Total dissolved solids, hardness as CaCO?, Calcium, Magnesium, Chlorides, Sulphates, Nitrate, Alkalinity, Iron, Turbidity NTU, Mineral oil, Colur hazen units, Taste, Odour, Residual free Chlorine, Total Coliform per 100ml (Microbiologocal test) & E Coli per 100ml (Microbiological test) complete and report to be submitted to the department in triplicate in hard bound copy complete all as specified and as directed
136S&F in repairs cast iron flanged type foot valve 200mm dia bore as per IS 4038 with Cast Iron strainer in two parts, mushroom valve gun metal seat and perforated CI/MS strainercomplete all as specified and directed. (Make: Kirloskar (KBL)/L&T/Leader)
137S&F in repairs cast iron flanged type foot valve 150mm dia bore as per IS 4038 with Cast Iron strainer in two parts, mushroom valve gun metal seat and perforated CI/MS strainercomplete all as specified and directed. (Make: Kirloskar (KBL)/L&T/Leader)
138S&F in repairs cast iron flanged type foot valve 100mm dia bore as per IS 4038 with Cast Iron strainer in two parts, mushroom valve gun metal seat and perforated CI/MS strainercomplete all as specified and directed. (Make: Kirloskar (KBL)/L&T/Leader)
139S&F in repair fully automatic star delta motor starter in sheet enclosure or fix type ML-03 suItable for 100 HP electric motor 3 phase, 440 volts and 50 HZ complete all as specified and directed. Make : BCH / Havells / L&T / Siemens / Crompton Greaves
140S&F in repair fully automatic star delta motor starter in sheet enclosure or fix type ML-03 suItable for 60/50 HP electric motor 3 phase, 440 volts and 50 HZ complete all as specified and directed. Make : BCH / Havells / L&T / Siemens / Crompton Greaves
141S&F in repair fully automatic star delta motor starter in sheet enclosure or fix type ML-03 suItable for 20/15 HP electric motor 3 phase, 440 volts and 50 HZ complete all as specified and directed. Make : BCH / Havells / L&T / Siemens / Crompton Greaves
142S&F in repair MCCB AC 415 volts, 125 Amp rating, breaking capacity of 35 KA,4 Pole, Conforming to IEC:60947-II / IS:13947-II) all as specified and directed (Make Havells cat No - IHLANF0125 or equivalent ofL&T / Legrand / Schneider)
143S&F in repair MCCB AC 415 volts, 200 Amp rating, breaking capacity of 35 KA,4 Pole, Conforming to IEC:60947-II / IS:13947-II) all as specified and directed (Make Havells cat No - IHLFNF0200 or equivalent ofL&T / Legrand / Schneider))
144S&F in repair MCCB AC 415 volts, 250 Amp rating, breaking capacity of 35 KA,4 Pole, Conforming to IEC:60947-II / IS:13947-II) all as specified and directed (Make Havells cat No - IHLFNF0250 or equivalent ofL&T / Legrand / Schneider)
145S&F in repair MCCB AC 415 volts, 630 Amp rating, breaking capacity of 36 KA,4 Pole, Conforming to IEC:60947-II / IS:13947-II) all as specified and directed (Make Havells cat No - IHLLSEBF0630 or equivalent ofL&T / Legrand / Schneider)
146M&L for earthing complete with galvanized steel plate electrode 600 X 600 X 6 mm thick buried directely in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GE earth strip of size 25 x 3mm as earthing lead by means of galvanized steel bolts,nuts check nuts and washers and other end connected with to Transformer, DG sets, Pannel board etc as directed including funnel, 20 mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50 mm thick pre cast RCC 1:2:4 type B1 with 8mm dia cover slab set in CM (1:4) reinforcement with 8mm dia deformed bars @ 15 cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No. 5 of MES schedule Part I and testing complete all as specified and as directed. (Note: GI Earthing strip upto 7.5m in lenght is deemed to be included in the unit rate. The Strip required beyond 7.5m shall be measured and paid for separately)
147S&F 25 x 3mm aluminium strip in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.complete all as specified and directed.
148M & L for preparation of old plastered surface including necessary scaffolding and applying twocoats of acrylic exterior paint over a coat of primer (brand apcolite Apexmanufactured by Asian or Brand weather coat manufactured by Berger or equivalent as approved by GE ) complete all as per manufactures instructions.complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail