| 1 | Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m |
| 2 | Carriage of Materials by mechanical transport including loading, unloading and stacking ::earth 2km lead |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:5:10 |
| 4 | Supplying and stacking good earth at site of workNote: 1) Loading, unloading and carriage to be paid extra as per actual lead. 2)Earth measured in stacks will be reduced by 20% foe payment |
| 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Foundation |
| 7 | Providing and laying TMT bar reinforcement at any level in foundation/ pile/ pile cap complete as per drawing and clause 1600 of MoRT&H Specification including all material, labour and machinery. |
| 8 | Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 9 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work |
| 10 | P/ F IP-65/ IP-66 protected street light luminaries on existing bracket. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance.LED street light fixture60 Watt |
| 11 | Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. 8 Mtr |
| 12 | Supply, Erection and Fixing of hot dipped galvanised Overhang (60 X 3.25 mm) with cap (250 x 137.9 x 4.05 mm) over the existing poles. Double arm overhang |
| 13 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 16.0 Sq.mm 4 core |
| 14 | 35.0 Sq.mm 3.5 core |
| 15 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required.2 x 1.5 sq.mm |
| 16 | S & Laying following size ‘B’ Class G.I. Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required. 50 mm dia. |
| 17 | P & F of IP 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch OFF at preselected time. Switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose Suitable for 15 kw load (three phase) including contactor, MCB, cable glands, terminal block and locking arrangement |
| 18 | P&F TP&N 415 V side handle operated double break fuse switch unit in sheet steel enclosure conforming to IS: 13947 P-III and IS:4064(W/o HBC fuses)including making connections with suitable lugs, testing etc. as required. 100 A rating |
| 19 | Supply and planting following speciesbest quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes,1 m deep dug in the ground,mixing the soil with decayed farm yard/sludge manure,backfilling the hole watering etc as required. Plumeria alba ( Champa) |
| 20 | Gulmohar (Delonix Regia) |
| 21 | Neem(Azadirachta indica) |