Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-11-2021 | Clause 29 | Other | 22-11-2021 |
| Sl. No. | Item Description |
| 1 | Building ZONE -1 |
| 2 | EARTH WORK |
| 3 | Supplying and filling cinder on roof (Ist story) including light ramming |
| 4 | CENTRING AND SHUTTERING WORK |
| 5 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 6 | Centering and shuttering for flat surfaces such assuspended floors, roofs, landings, chajjas, shelves etc. |
| 7 | CONCRETE WORK |
| 8 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concretemixer volumetric type |
| 9 | BRICK WORK |
| 10 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 11 | HOISTING AND ROOFING WORK |
| 12 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allowmovement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 13 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 14 | Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
| 15 | FLOORING AND CLADDING WORK |
| 16 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 17 | Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 18 | 50mm thick ironite ( Metallic Floor Hardner to be mixed with Granolithic topping for heavy duty floors) floor consisiting of 40mm thick cement concrete 1:2:4 base and top layer 10mm thick laid with one part of ironite and grey cement mixed together in the ratio of 1:4 by weight to two parts of hard granite chippings 6mm gauge by volume finished smooth with hard rubbing |
| 19 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Makrana, Doongri, Adanga viened and chack Doongri with grey stretches. Slabs sizes above 0.50 sqm |
| 20 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 21 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 22 | Providing and fixing copper pins 7.5 cm long 6mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases |
| 23 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 24 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 25 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 26 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 27 | Plain Cement Concrete Pavement Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 gradeconforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications |
| 28 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Bansi Paharpur Stone - Exposed face machine cut & table rubber with rough backing40mm thick |
| 29 | PLASTER AND POINTING WORK |
| 30 | 10mm thick Cement Plaster 1:4 |
| 31 | 12.5 mm thick cement plaster 1:5 |
| 32 | 20mm thick cement plaster 1:5 in two coat work |
| 33 | PAINTING WORK |
| 34 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 35 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 36 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior / internal surface |
| 37 | Spirit polishing two coats including a coat of wood filler on wood work |
| 38 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 39 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 40 | WOOD WORK |
| 41 | Chowkats of Imp. Teak Wood confirming to ISI specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops bolts for hold fasts etc, complete fixed in position (Section 60mm x 150mm) Double Rebate (60mm x 150mm) (60mm x 150mm) |
| 42 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing thesame in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 43 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 44 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sideswith required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointedmechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats |
| 45 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug /neoprene gasket required |
| 46 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle boardconforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 47 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thickness |
| 48 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 4 mm thickness |
| 49 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, fordoors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single pieceMS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin-charge. |
| 50 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm |
| 51 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer\"s specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 52 | Providing & fixing 30mm thick factory made Hollow PVC Profile PVC Flush door shutter consisting of panel of of 20mm thickness,frame made out of M.S. tubes of size of 19mm x 19mm x19 guage inserted inside the hollow section of stiles, top and bottom rails and two 19mm x 19mm MS tubes inserted horizontally inside the hollow profile section using 5mm thick PVC sheet using screws. Hollow PVC profile shall be lipped with 10mm (5mm x 2) thick x 20mm width on stiles and rails using solvent cement. the inner panel shall be laminated with 5mm thick termite proof, water proof and fire retardant Prelam PVC sheet using solvent cement on both the sides of panel etc. complete as per manufacturer\"s specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 53 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casementhandles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall bepaid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension on higher side shall be accepted but no extra payment on this account shall be made. |
| 54 | Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series)frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and singleglazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). |
| 55 | Providing and Fixing Single Glazing with 6mm thick glass with high perfromance coating as per relevent codal provisions as per satisfaction of Engineer-in-Charge. |
| 56 | Providing and fixing aluminum grill 6.3 mm including cost of necessary fittings i.e. screws,u Type Beading etc. complete |
| 57 | Providing and fixing aluminum Wire Mesh including cost of necessary fittings i.e. screws,u Type Beading etc. complete |
| 58 | STEEL WORK |
| 59 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 60 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 61 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 62 | Extra rate for steel reinforcement produced by primary producer |
| 63 | BUILDINGZONE -2A |
| 64 | BRICK WORK |
| 65 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 66 | HOISTING AND ROOFING WORK |
| 67 | Providing and fixing polycarbonate sheet sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws with EPDM seal, and the joints shall beprovided with aluminium strips at top and bottom as a seal complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Pollycarbonate sheet Multiwalled 12mm thick |
| 68 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allowmovement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 69 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 70 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary |
| 71 | cross \"T\" of length 600 mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the1200x600 mm panel to form grids of 600x600 mm and wallangle of size 24x24x0.3 mm and laying false ceiling tiles ofapproved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 72 | Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
| 73 | FLOORING AND CLADDING WORK |
| 74 | Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately).Udaipur Green Marble Tiles ofthickness 12mm to 15mmSlabs sizes above 0.50 Sqm |
| 75 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 76 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 77 | Providing and fixing copper pins 7.5 cm long 6mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases |
| 78 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Bansi Paharpur Stone - Exposed face machine cut & table rubber with rough backing40mm thick |
| 79 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone |
| 80 | PLASTER AND POINTING WORK |
| 81 | 12.5 mm thick cement plaster 1:5 |
| 82 | PAINTING WORK |
| 83 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 84 | Spirit polishing two coats including a coat of wood filler on wood work |
| 85 | Finishing walls with textured exterior / interior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 86 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 87 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 88 | WOOD WORK |
| 89 | Teak wood wrought planed and fixed in position (Chowkats) |
| 90 | Imported Teak Wood doors shutter windows shutter including hinges, screw and cords etc. Complete fixed in position Panelled, glazed or glazed and panelled. 40mm thick (Single / Double Leaf) |
| 91 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminum doors including necessary cutting and making good etc. complete. |
| 92 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect 8.0mm thick Plate glass(weight not less than 20 kg/ sqm) |
| 93 | Providing and fixing teak wood beading to door windows chowkats with iron screws fixed in position complete as per design and shape required 50mmx12mm |
| 94 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000/3000mm) |
| 95 | Providing & fixing 1\"-6\" stainless steel handles ISI marked on door & window frames complete in all respect as per thedirections of Engineer-in-charge. |
| 96 | Providing & fixing 12\" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per thedirections of Engineer-in-charge. |
| 97 | STEEL WORK |
| 98 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 99 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 100 | Extra rate for steel reinforcement produced by primary producer |
| 101 | BUILDING ZONE -2B |
| 102 | EARTH WORK |
| 103 | Supplying and filling sand on roof (Ist story) including light ramming |
| 104 | CENTRING AND SHUTTERING WORK |
| 105 | Centering and shuttering for flat surfaces such assuspended floors, roofs, landings, chajjas, shelves etc. |
| 106 | CONCRETE WORK |
| 107 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concretemixer volumetric type |
| 108 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 109 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the sameshall be deducted ) |
| 110 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 111 | BRICK WORK |
| 112 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 113 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 114 | HOISTING AND ROOFING WORK |
| 115 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allowmovement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 116 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 117 | Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
| 118 | FLOORING AND CLADDING WORK |
| 119 | 50mm thick ironite ( Metallic Floor Hardner to be mixed with Granolithic topping for heavy duty floors) floor consisiting of 40mm thick cement concrete 1:2:4 base and top layer 10mm thick laid with one part of ironite and grey cement mixed together in the ratio of 1:4 by weight to two parts of hard granite chippings 6mm gauge by volume finished smooth with hard rubbing |
| 120 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 121 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Makrana, Doongri, Adanga viened and chack Doongri with grey stretches. Slabs sizes above 0.50 sqm |
| 122 | Marble work of thickness 18-20 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Udaipur Green Marble Tiles of thickness 15mm to 20mm Slabs sizes above 0.50 sqm |
| 123 | Kota stone slab 20-25 mm thick flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 124 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, includingrubbing and polishing |
| 125 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 126 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 127 | Providing and fixing copper pins 7.5 cm long 6mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases |
| 128 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 129 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 130 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 131 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 132 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Bansi Paharpur Stone - Exposed face machine cut & table rubber with rough backing40mm thick |
| 133 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone |
| 134 | Providing and Fixing Toilet Cubicles System made of 12mm thick compact laminated board size as per drawing x 2100mm, door siize 600mm x 1750mm over all height cubicals 2100mm including bottom gap of 150mm excessary SS 304 Grade such as U channel, F Channel, SS Top rail, SS coat huk, SS Privacy thumb turn SS Door Knob, SS Hing with cover, SS adjustable foot, rubber linning for groove screws and PVC Wall plug merino Make or euivalantcomplege in all respect as per specification and as desired by engineer in charge] (Payment to be made per square meter of the partition including doors) |
| 135 | PLASTER AND POINTING WORK |
| 136 | 10mm thick Cement Plaster 1:4 |
| 137 | 12.5 mm thick cement plaster 1:5 |
| 138 | 20mm thick cement plaster 1:5 in two coat work |
| 139 | PAINTING WORK |
| 140 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 141 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 142 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior / internal surface |
| 143 | Spirit polishing two coats including a coat of wood filler on wood work |
| 144 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 145 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 146 | WOOD WORK |
| 147 | Chowkats of Imp. Teak Wood confirming to ISI specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops bolts for hold fasts etc, complete fixed in position (Section 60mm x 150mm) Double Rebate (60mm x 150mm) (60mm x 150mm) |
| 148 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing thesame in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 149 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 150 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sideswith required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointedmechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats |
| 151 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug /neoprene gasket required |
| 152 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle boardconforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 153 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thickness |
| 154 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 4 mm thickness |
| 155 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, fordoors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single pieceMS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin-charge. |
| 156 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm |
| 157 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer\"s specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 158 | Providing & fixing 30mm thick factory made Hollow PVC Profile PVC Flush door shutter consisting of panel of of 20mm thickness,frame made out of M.S. tubes of size of 19mm x 19mm x19 guage inserted inside the hollow section of stiles, top and bottom rails and two 19mm x 19mm MS tubes inserted horizontally inside the hollow profile section using 5mm thick PVC sheet using screws. Hollow PVC profile shall be lipped with 10mm (5mm x 2) thick x 20mm width on stiles and rails using solvent cement. the inner panel shall be laminated with 5mm thick termite proof, water proof and fire retardant Prelam PVC sheet using solvent cement on both the sides of panel etc. complete as per manufacturer\"s specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 159 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casementhandles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall bepaid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension on higher side shall be accepted but no extra payment on this account shall be made. |
| 160 | Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series)frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and singleglazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). |
| 161 | Providing and Fixing Single Glazing with 6mm thick glass with high perfromance coating as per relevent codal provisions as per satisfaction of Engineer-in-Charge. |
| 162 | Providing and fixing aluminum grill 6.3 mm including cost of necessary fittings i.e. screws,u Type Beading etc. complete |
| 163 | Providing and fixing aluminum Wire Mesh including cost of necessary fittings i.e. screws,u Type Beading etc. complete |
| 164 | STEEL WORK |
| 165 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 166 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 167 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 168 | Extra rate for steel reinforcement produced by primary producer |
| 169 | Building ZONE -3A |
| 170 | Earth Work |
| 171 | Earth filling under floors with surplus soil containing more than 40% taking outside the premises in 15 cm layers including ramming watering and consolidated lead upto 1000 metres |
| 172 | Fine grassing including uprooting rank vegetation and weeds by digging the area to a depth of 30 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days, mixing fertilizer and then fine dressing for planting new grass, including disposal of allrubbish with all leads and lifts, watering, weeding and maintenance for 30 days or till thick lawn is formed. Planting Selection no. 1 grass roots in rows 10 cm apart in both directions. |
| 173 | CENTRING AND SHUTTERING WORK |
| 174 | Centering and shuttering for flat surfaces such assuspended floors, roofs, landings, chajjas, shelves etc. |
| 175 | CONCRETE WORK |
| 176 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 177 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the sameshall be deducted ) |
| 178 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 179 | BRICK WORK |
| 180 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 181 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 182 | HOISTING AND ROOFING WORK |
| 183 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allowmovement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 184 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 185 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary |
| 186 | cross \"T\" of length 600 mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the1200x600 mm panel to form grids of 600x600 mm and wallangle of size 24x24x0.3 mm and laying false ceiling tiles ofapproved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 187 | Waterproofing of wet areas ( Concrete/ Masonary Surface ) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionouscoating ( DR. FIXIT FASTFLEX / Equivalent ) to provide tough film build-up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface preprationand cleaning, washing and removing dust,dirt and loose particles from concrete / masonary surface complete in all respects. |
| 188 | FLOORING AND CLADDING WORK |
| 189 | Precast chequred tiles of 20mm minimum thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base for floors, treads of steps and landings |
| 190 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 191 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Makrana, Doongri, Adanga viened and chack Doongri with grey stretches. Slabs sizes above 0.50 sqm |
| 192 | Marble work of thickness 18-20 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Udaipur Green Marble Tiles of thickness 15mm to 20mm Slabs sizes above 0.50 sqm |
| 193 | Kota stone slab 20-25 mm thick flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 194 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, includingrubbing and polishing |
| 195 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 196 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 197 | Providing and fixing copper pins 7.5 cm long 6mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases |
| 198 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 199 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 200 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 201 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Bansi Paharpur Stone - Exposed face machine cut & table rubber with rough backing40mm thick |
| 202 | Providing and Fixing Toilet Cubicles System made of 12mm thick compact laminated board size as per drawing x 2100mm, door siize 600mm x 1750mm over all height cubicals 2100mm including bottom gap of 150mm excessary SS 304 Grade such as U channel, F Channel, SS Top rail, SS coat huk, SS Privacy thumb turn SS Door Knob, SS Hing with cover, SS adjustable foot, rubber linning for groove screws and PVC Wall plug merino Make or euivalantcomplege in all respect as per specification and as desired by engineer in charge] (Payment to be made per square meter of the partition including doors) |
| 203 | PLASTER AND POINTING WORK |
| 204 | 10mm thick Cement Plaster 1:4 |
| 205 | 12.5 mm thick cement plaster 1:5 |
| 206 | 20mm thick cement plaster 1:5 in two coat work |
| 207 | PAINTING WORK |
| 208 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 209 | Spirit polishing two coats including a coat of wood filler on wood work |
| 210 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 211 | WOOD WORK |
| 212 | Chowkats of Imp. Teak Wood confirming to ISI specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops bolts for hold fasts etc, complete fixed in position (Section 60mm x 150mm) Double Rebate (60mm x 150mm) (60mm x 150mm) |
| 213 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing thesame in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 214 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 215 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sideswith required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointedmechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats |
| 216 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug /neoprene gasket required |
| 217 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle boardconforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 218 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thickness |
| 219 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 4 mm thickness |
| 220 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, fordoors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single pieceMS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin-charge. |
| 221 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm |
| 222 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer\"s specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 223 | Providing & fixing 30mm thick factory made Hollow PVC Profile PVC Flush door shutter consisting of panel of of 20mm thickness,frame made out of M.S. tubes of size of 19mm x 19mm x19 guage inserted inside the hollow section of stiles, top and bottom rails and two 19mm x 19mm MS tubes inserted horizontally inside the hollow profile section using 5mm thick PVC sheet using screws. Hollow PVC profile shall be lipped with 10mm (5mm x 2) thick x 20mm width on stiles and rails using solvent cement. the inner panel shall be laminated with 5mm thick termite proof, water proof and fire retardant Prelam PVC sheet using solvent cement on both the sides of panel etc. complete as per manufacturer\"s specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 224 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casementhandles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall bepaid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension on higher side shall be accepted but no extra payment on this account shall be made. |
| 225 | Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series)frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and singleglazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). |
| 226 | Providing and Fixing Single Glazing with 6mm thick glass with high perfromance coating as per relevent codal provisions as per satisfaction of Engineer-in-Charge. |
| 227 | Providing and fixing aluminum grill 6.3 mm including cost of necessary fittings i.e. screws,u Type Beading etc. complete |
| 228 | Providing and fixing aluminum Wire Mesh including cost of necessary fittings i.e. screws,u Type Beading etc. complete |
| 229 | STEEL WORK |
| 230 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 231 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 232 | Extra rate for steel reinforcement produced by primary producer |
| 233 | ZONE -3B |
| 234 | HOISTING AND ROOFING WORK |
| 235 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allowmovement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 236 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 237 | FLOORING AND CLADDING WORK |
| 238 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 239 | Lvl. 85.05 |
| 240 | Lvl. 94.3 |
| 241 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 242 | Providing and fixing copper pins 7.5 cm long 6mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases |
| 243 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Bansi Paharpur Stone - Exposed face machine cut & table rubber with rough backing40mm thick |
| 244 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone |
| 245 | PLASTER AND POINTING WORK |
| 246 | 20mm thick cement plaster 1:5 in two coat work |
| 247 | PAINTING WORK |
| 248 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 249 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 250 | STEEL WORK |
| 251 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 252 | BUILDING ZONE -3C |
| 253 | EARTH WORK |
| 254 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 255 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outsidethe building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 256 | Earth filling under floors with surplus soil containing more than 40% taking outside the premises in 15 cm layers including ramming watering and consolidated lead upto 1000 metres |
| 257 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer\"s specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 258 | CENTRING AND SHUTTERING WORK |
| 259 | Shuttering for faces of concrete foundations and foundationbeam & plinth beam (vertical or battering) |
| 260 | Centering and shuttering for faces of walls, partitions,retaining walls and the like (vertical or battering) includingattached pilasters, buttresses etc when curved. |
| 261 | Below Ground Floor |
| 262 | Ground Floor |
| 263 | Centering and shuttering for columns (Square or rectangularor poly gonal in plain) |
| 264 | Below Ground Floor |
| 265 | Ground Floor |
| 266 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 267 | Below Ground Floor |
| 268 | Ground Floor |
| 269 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 270 | Below Ground Floor |
| 271 | Ground Floor |
| 272 | Centring and shuttering for stair cases with sloping withsoffits including risers and stringers. |
| 273 | Below Ground Floor |
| 274 | CONCRETE WORK |
| 275 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 276 | Cement concrete 1:3:6 with stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type |
| 277 | Conglomerate floor 50mm thick cement concrete rete 1:2:4 on 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material |
| 278 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibratedby needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 279 | Reinforced cement concrete M-40 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibratedby needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 280 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibratedby needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 281 | Below Ground Floor |
| 282 | Ground Floor |
| 283 | Reinforced cement concrete M-40 mechanically batch mixed using batch mixed using concrete mixer and vibrated by needlevibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 284 | Below Ground Floor |
| 285 | Ground Floor |
| 286 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the sameshall be deducted ) |
| 287 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 288 | BRICK WORK |
| 289 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 290 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 291 | Extra for c above 4 meters (where any single storey exceeds 4 metres in height) for every additional height of 2 metres or part thereof for Brick Work/ Concrete Block/ Clay Block. |
| 292 | 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in foundations and plinth |
| 293 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 294 | Extra for 115mm/100mm thick of walls done above 4 meters (where any single storey exceeds 4 meters in height) for every additional height of 2 meters or parts thereof for Brick Work/ Concrete Block/ Clay Block. |
| 295 | HOISTING AND ROOFING WORK |
| 296 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mmthick cement concrete 1:8:16 |
| 297 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 298 | Supplying and filling cinder on roof (Ist story) including light ramming |
| 299 | Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings specifications and to the entire satisfaction of engineer-in- charge. |
| 300 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 301 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction ofEngineer-in- charge. |
| 302 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend |
| 303 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction ofEngineer- in- charge. |
| 304 | Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer. |
| 305 | Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to befixed in horiziontal direction at 600mm center to centerso as to form a grid of 600mm x 600mm. |
| 306 | Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles areto be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre ) roll and two coats of primersuitable for panelling as per manufacturer\"s specificationas per direction of Engineer-in-Charge all complete. |
| 307 | Water proofing treatment of RCC structures (after making the surface clean, dry & free from all internal voids or honey combs ), with Zycosil /equivalent water proofing Solution (1 litre of Zycosil / equivalent & 20 litres of potable waterstirred first & 2 litres of Zycoprime / equivalent added and stirred (total 23 litres)) using two coats till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls. |
| 308 | Water proofing of roof terraces, Basements, Retaining Walls, Water tanks etc with Zydex Zycoprime / Elastobar / Equivalent solution so as to form a water-resistant cementitious bondingcoat and to form on-site seamless cross-linked elastomeric membrane on the concrete surface to reduce its porosity. Creating a cementitious elastomeric polymeric membrane of Elastobar and Zycoprime/Equivalent after application ofZycosil & Zycoprime Solution in New Construction. Take equal parts of Elastobar and Cement and form a paste. Add little water to the paste to make it brushable. Apply the paste on surface with brush. Leave the surace for drying for at least 4 - 6 hours to get elastomeric membrane. After this application, make one more layer of rough cementatios membrane using mixture of 1Part of Zycoprime + 1 Part of Cement + 1 Part of fine sand. Apply paste on the surface with a brush to make a rough texture. Now your surface is ready to bond well with tiles/screed. |
| 309 | Waterproofing of wet areas ( Concrete/ Masonary Surface ) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating ( DR. FIXIT FASTFLEX / Equivalent ) to provide tough film build-up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface prepration and cleaning, washing and removing dust,dirt and loose particles from concrete / masonary surface complete in all respects. |
| 310 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 20 mm thick beveled tegular mineral fibre false ceilingtile (NRC 0.7) |
| 311 | FLOORING AND CLADDING WORK |
| 312 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 313 | Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 314 | Below Ground Floor |
| 315 | Ground Floor |
| 316 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material |
| 317 | Below Ground Floor |
| 318 | Ground Floor |
| 319 | 40mm thick grey polished flooring cement concrete 1:2:4 toping finished with 3mm thick neat coat of cement rubbed and polished using mechanical mixer for mixing of material |
| 320 | Extra labour for projected nosing of stair case of any shape and design. |
| 321 | Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. |
| 322 | Precast chequred tiles of 20mm minimum thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base for floors, treads of steps and landings |
| 323 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 324 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Makrana, Doongri, Adanga viened and chack Doongri with grey stretches. Slabs sizes above 0.50 sqm |
| 325 | Marble work of thickness 18-20 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Udaipur Green Marble Tiles of thickness 15mm to 20mm Slabs sizes above 0.50 sqm |
| 326 | Kota stone slab 20-25 mm thick flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbingand polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 327 | Below Ground Floor |
| 328 | Ground Floor |
| 329 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, includingrubbing and polishing |
| 330 | Below Ground Floor |
| 331 | Ground Floor |
| 332 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 333 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 334 | Providing and fixing copper pins 7.5 cm long 6mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases |
| 335 | Providing and laying Laminate wooden flooring (Grade AC4 or AC4+ laminates) 6 mm to 12 mm thick, having a good backing layer made up of plastic laminate or melamine, core made up of medium-density fiberboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top wear layer having clear aluminum oxide finish that protects the decorative layer & imparts thedesired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacturer. |
| 336 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 337 | Below Ground Floor |
| 338 | Ground Floor |
| 339 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 340 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 341 | Providing & fixing of 4.5 mm thick Carpet tile flooring not made of 100 % polyfine polypropleyne natural with dual baching, Primary baching with PVC & Secondary with fibar glass form approved make in required colours, shades, Complete as per manufacture\"s specification including cost of special quality adhesive complete fixed in position to the entire satisfaction of engineer in charge. |
| 342 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Bansi Paharpur Stone - Exposed face machine cut & table rubber with rough backing40mm thick |
| 343 | PLASTER AND POINTING WORK |
| 344 | 10mm thick Cement Plaster 1:4 |
| 345 | Below Ground Floor |
| 346 | Ground Floor |
| 347 | 12.5 mm thick cement plaster 1:5 |
| 348 | Below Ground Floor |
| 349 | Ground Floor |
| 350 | 20mm thick cement plaster 1:5 in two coat work |
| 351 | Below Ground Floor |
| 352 | Ground Floor |
| 353 | External wall surface |
| 354 | PAINTING WORK |
| 355 | White washing (Three coat) |
| 356 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 357 | Below Ground Floor |
| 358 | Ground Floor |
| 359 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 360 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 361 | Spirit polishing two coats including a coat of wood filler on wood work |
| 362 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 363 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 364 | WOOD WORK |
| 365 | Chowkats of Imp. Teak Wood confirming to ISI specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops bolts for hold fasts etc, complete fixed in position (Section 60mm x 150mm) Double Rebate (60mm x 150mm) (60mm x 150mm) |
| 366 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1) (1999)Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 367 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 368 | Providing and fixing teak wood beading to door windows chowkats with iron screws fixed in position complete as per design and shape required 50mmx12mm |
| 369 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 370 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sideswith required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointedmechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats |
| 371 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug /neoprene gasket required |
| 372 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle boardconforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 373 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thickness |
| 374 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 4 mm thickness |
| 375 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, fordoors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single pieceMS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin-charge. |
| 376 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm |
| 377 | Providing & fixing 46mm thick fully flush double skin fire door shutter of 120 minutes fire rating confirming to IS:3614(Part II),tested & certified by CBRI (Roorki). Door frame & leaf shall be manufactured from 1.6mm (16 gauge) & 1.2mm (18guage) minimum thick galvanised steel sheet.The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. The edges should be interlocked with lock seam. All doors shall be finished with polyurethane aliphatic grade paint of approved colour. The door shall have passed minimum 250 hours of salt spray test. |
| 378 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casementhandles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall bepaid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension on higher side shall be accepted but no extra payment on this account shall be made. |
| 379 | Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series)frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and singleglazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). |
| 380 | Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension.(Area upto 0.75 sqm) |
| 381 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. |
| 382 | For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 383 | Providing and fixing aluminum grill 6.3 mm including cost of necessary fittings i.e. screws,u Type Beading etc. complete |
| 384 | Providing and fixing aluminum Wire Mesh including cost of necessary fittings i.e. screws,u Type Beading etc. complete |
| 385 | Providing & Fixing AMBRE-FAMELINE Aluminium 750 AF Louvre is a special type of louver with width of 150mm. The thickness of the aluminium sheet is 1.2mm and with the total length of 0.6meters of each panel. The Aluminium 750 AF Louvre then attached to the special extruded frame with length of 6meters support which incorporated to the main frame of glass to provide firmness and stability. The panel are locked by a special pin in Stainless Steel 304, in a module of C/C finalize by the architect. PAINT FINISH: Electrostatically Polyester Powder Coating Gloss Level 35%, minimum Thickness 60 micron tested according to ASTM B 117. Or Electrostatically Baked Enamel Spray Painting (Acrylic resin) Gloss Level 35%, minimum Thickness 30 micron. Paint is as per AMBRE-FAMELINE exterior paint finish as per manufacturer\"s specification. |
| 386 | Providing and Fixing Toilet Cubicles System made of 12mm thick compact laminated board size as per drawing x 2100mm, door siize 600mm x 1750mm over all height cubicals 2100mm including bottom gap of 150mm excessary SS 304 Grade such as U channel, F Channel, SS Top rail, SS coat huk, SS Privacy thumb turn SS Door Knob, SS Hing with cover, SS adjustable foot, rubber linning for groove screws and PVC Wall plug merino Make or euivalantcomplege in all respect as per specification and as desired by engineer in charge] (Payment to be made per square meter of the partition including doors) |
| 387 | STEEL WORK |
| 388 | Structural steel work in angles, tees, flats, riveted, including cutting, fixing all gusset plates, bolts, nuts, rivets etc. with hoisting and erecting in position. For plates and trussed girders etc. for bridge of span more than 15 metres but upto 30 mts. Span including cost of all machinery i.e hydra crane etc |
| 389 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 390 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 391 | Below Ground Floor |
| 392 | Ground Floor |
| 393 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 394 | Extra rate for steel reinforcement produced by primary producer |
| 395 | ZONE -4 |
| 396 | EARTH WORK |
| 397 | Eaxcavation in Soil(any type) using Hydraulic Excavator CK 90 Excavation with hydraulic excavator of 0.9 cum bucket capacity including cutting trimming bottom sand side slopes, in accordance with requirements of lines, grades and cross sections, including all lift and combined lead up to 60 mtr. |
| 398 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth In 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 399 | ProvidingandapplyingAntiTermite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containing chloropyrifos systemic insecticide diluted to manufacturer\"sspecifications(i)In foundationpits,bytreatingthebottom& sides up to height of 300mm by uniformly spraying solution @ 5 Litre / sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter (width - 300 mm, depth - 450 mm) (iii)Before laying the floor, by uniformly sprinkling the top surface oftheconsolidated earthwithintheouter perimeter @ 5 Litre solution per sqm. |
| 400 | CONCRETE WORK |
| 401 | Cement concrete 1:4:8 with stone ballast of 40mm guage. Using volumetric type concrete mixer |
| 402 | Cement concrete 1:3:6 with stone ballast or shingle 40 mm guage. using concrete mixing volumetric type |
| 403 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrated by needle vibrater but excludingsteel reinforcement,centring and shuttering in foundation and plinth. |
| 404 | Reinforced cement concrete M-30 mechanicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrated by needle vibrater but excludingsteel reinforcement,centring and shuttering in superstructure. |
| 405 | Ground floor |
| 406 | First Floorwith Extra cost of subsequent storey |
| 407 | Second Floor with Extra cost of subsequent storey |
| 408 | Third Floor with Extra cost of subsequent storey |
| 409 | FourthFloor with Extra cost of subsequent storey |
| 410 | 5th Floor with Extra cost of subsequent storey |
| 411 | 6th Floor with Extra cost of subsequent storey |
| 412 | 7th Floor with Extra cost of subsequent storey |
| 413 | 8th Floor with Extra cost of subsequent storey |
| 414 | 9th Floor with Extra cost of subsequent storey |
| 415 | 10th Floor with Extra cost of subsequent storey |
| 416 | 11th Floor with Extra cost of subsequent storey |
| 417 | Extra for using computerized concrete batch mixingplant includingcarriage by transitmixerwith in1 km lead. (Note- Where concrete mixer is already included in the rate the same shall be deductedbefore adding this item) |
| 418 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 419 | CENTRING AND SHUTTERING WORK |
| 420 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 421 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc when curved. |
| 422 | Basement Floor |
| 423 | Ground floor |
| 424 | First Floor |
| 425 | Second floor |
| 426 | Thrid Floor |
| 427 | Fourth Floor |
| 428 | 5th Floor |
| 429 | 6th Floor |
| 430 | 7th Floor |
| 431 | 8th Floor |
| 432 | 9th Floor |
| 433 | 10th Floor |
| 434 | 11th Floor |
| 435 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 436 | Basement Floor |
| 437 | Ground floor |
| 438 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 439 | Basement Floor |
| 440 | Ground floor |
| 441 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 442 | Basement Floor |
| 443 | Ground floor |
| 444 | First Floor |
| 445 | Second floor |
| 446 | Thrid Floor |
| 447 | Fourth Floor |
| 448 | 5th Floor |
| 449 | 6th Floor |
| 450 | 7th Floor |
| 451 | 8th Floor |
| 452 | 9th Floor |
| 453 | 10th Floor |
| 454 | 11th Floor |
| 455 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
| 456 | Basement Floor |
| 457 | Ground floor |
| 458 | First Floor |
| 459 | Second floor |
| 460 | Thrid Floor |
| 461 | Fourth Floor |
| 462 | 5th Floor |
| 463 | 6th Floor |
| 464 | 7th Floor |
| 465 | 8th Floor |
| 466 | 9th Floor |
| 467 | 10th Floor |
| 468 | 11th Floor |
| 469 | BRICK WORK |
| 470 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 471 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 472 | ground Floor |
| 473 | First Floorextra for additional story uptu 4 mtrs abovethe top of structural roof of story |
| 474 | Second Floorextra for additional story uptu 4 mtrs abovethe top of structural roof of story |
| 475 | Third Floorextra for additional story uptu 4 mtrs abovethe top of structural roof of story |
| 476 | fourth Floorextra for additional story uptu 4 mtrs abovethe top of structural roof of story |
| 477 | 5thfloor extra for additional story uptu 4 mtrs abovethe top of structural roof of story |
| 478 | 6thfloor extra for additional story uptu 4 mtrs abovethe top of structural roof of story |
| 479 | 7thfloor extra for additional story uptu 4 mtrs abovethe top of structural roof of story |
| 480 | 8thfloor extra for additional story uptu 4 mtrs abovethe top of structural roof of story |
| 481 | 9thfloorextra for additional story uptu 4 mtrs abovethe top of structural roof of story |
| 482 | 10thfloorextra for additional story uptu 4 mtrs abovethe top of structural roof of story |
| 483 | 115 mm thick brick wall laid in cement mortar 1:4withoutreinforcement infoundationand plinth. |
| 484 | FLOORING AND CLADDING WORK |
| 485 | Screed 50mm thick of cement concrete 1:8:16 to be laid below the toping. |
| 486 | Basement Floor |
| 487 | Ground floor |
| 488 | First Floor |
| 489 | Second floor |
| 490 | Thrid Floor |
| 491 | Fourth Floor |
| 492 | 5th Floor |
| 493 | 6th Floor |
| 494 | 7th Floor |
| 495 | 8th Floor |
| 496 | 9th Floor |
| 497 | 10th Floor |
| 498 | 11th Floor |
| 499 | Kotah stone tile flooring 20mm to 30mm thick over 12.5mm thick base of cement mortar 1:3 laid and jointed with neat cemetn slurry mixed with pigment to match the shade of stone including rubbing & polishing. |
| 500 | Basement Floor |
| 501 | Ground floor |
| 502 | Kotah stone tile 20mm thick in skirting riser of steps dado walls and pillars laid in 12.5mm thick base of cement mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing & polishing . |
| 503 | Basement Floor |
| 504 | Ground floor |
| 505 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. |
| 506 | Basement Floor |
| 507 | Ground floor |
| 508 | First Floor |
| 509 | Second floor |
| 510 | Thrid Floor |
| 511 | Fourth Floor |
| 512 | 5th Floor |
| 513 | 6th Floor |
| 514 | 7th Floor |
| 515 | 8th Floor |
| 516 | 9th Floor |
| 517 | 10th Floor |
| 518 | 11th Floor |
| 519 | Extra labour for projected nosing of stair case of any shape and design. |
| 520 | Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. |
| 521 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 522 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 523 | Providing and fixing copper pins 7.5 cm long 6mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases |
| 524 | PLASTER AND POINTING WORK |
| 525 | 12.5mm thick cement plaster 1:5 (for internal wall) |
| 526 | Basement Floor |
| 527 | Ground floor |
| 528 | First Floor |
| 529 | Second floor |
| 530 | Thrid Floor |
| 531 | Fourth Floor |
| 532 | 5th Floor |
| 533 | 6th Floor |
| 534 | 7th Floor |
| 535 | 8th Floor |
| 536 | 9th Floor |
| 537 | 10th Floor |
| 538 | 11th Floor |
| 539 | 10mm thick Cement Plaster 1:4 |
| 540 | Basement Floor |
| 541 | Ground floor |
| 542 | First Floor |
| 543 | Second floor |
| 544 | Thrid Floor |
| 545 | Fourth Floor |
| 546 | 5th Floor |
| 547 | 6th Floor |
| 548 | 7th Floor |
| 549 | 8th Floor |
| 550 | 9th Floor |
| 551 | 10th Floor |
| 552 | 11th Floor |
| 553 | 20mm thick cement plaster 1:5 in two coat work |
| 554 | Basement Floor |
| 555 | Ground floor |
| 556 | First Floor |
| 557 | Second floor |
| 558 | Thrid Floor |
| 559 | Fourth Floor |
| 560 | 5th Floor |
| 561 | 6th Floor |
| 562 | 7th Floor |
| 563 | 8th Floor |
| 564 | 9th Floor |
| 565 | 10th Floor |
| 566 | 11th Floor |
| 567 | PAINTING WORK |
| 568 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 569 | Basement Floor |
| 570 | Ground floor |
| 571 | First Floor |
| 572 | Second floor |
| 573 | Thrid Floor |
| 574 | Fourth Floor |
| 575 | 5th Floor |
| 576 | 6th Floor |
| 577 | 7th Floor |
| 578 | 8th Floor |
| 579 | 9th Floor |
| 580 | 10th Floor |
| 581 | 11th Floor |
| 582 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 583 | Basement Floor |
| 584 | Ground floor |
| 585 | First Floor |
| 586 | Second floor |
| 587 | Thrid Floor |
| 588 | Fourth Floor |
| 589 | 5th Floor |
| 590 | 6th Floor |
| 591 | 7th Floor |
| 592 | 8th Floor |
| 593 | 9th Floor |
| 594 | 10th Floor |
| 595 | 11th Floor |
| 596 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 597 | Basement Floor |
| 598 | Ground floor |
| 599 | First Floor |
| 600 | Second floor |
| 601 | Thrid Floor |
| 602 | Fourth Floor |
| 603 | 5th Floor |
| 604 | 6th Floor |
| 605 | 7th Floor |
| 606 | 8th Floor |
| 607 | 9th Floor |
| 608 | 10th Floor |
| 609 | 11th Floor |
| 610 | Applying pink primer or aluminium priming coaton wood work including preparation of surface knothing and stopping etc.(with special quality paint) |
| 611 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 612 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. (with special quality paint) |
| 613 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 614 | Spirit polishing two coats including a coat of wood filler on wood work |
| 615 | WOOD WORK |
| 616 | Chowkats of Imp. Teak Wood confirming to ISI specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops bolts for hold fasts etc, complete fixed in position (Section 60mm x 150mm) Double Rebate (60mm x 150mm) (60mm x 150mm) |
| 617 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1) (1999)Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 618 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 619 | Providing and fixing teak wood beading to door windows chowkats with iron screws fixed in position complete as per design and shape required 50mmx12mm |
| 620 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 621 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm |
| 622 | Providing & fixing 46mm thick fully flush double skin fire door shutter of 120 minutes fire rating confirming to IS:3614(Part II),tested & certified by CBRI (Roorki). Door frame & leaf shall be manufactured from 1.6mm (16 gauge) & 1.2mm (18guage) minimum thick galvanised steel sheet.The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. The edges should be interlocked with lock seam. All doors shall be finished with polyurethane aliphatic grade paint of approved colour. The door shall have passed minimum 250 hours of salt spray test. |
| 623 | STEEL WORK |
| 624 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 625 | Gr. Floor |
| 626 | First Floor |
| 627 | Second floor |
| 628 | Thrid Floor |
| 629 | Fourth Floor |
| 630 | 5th Floor |
| 631 | 6th Floor |
| 632 | 7th Floor |
| 633 | 8th Floor |
| 634 | 9th Floor |
| 635 | 10th Floor |
| 636 | 11th Floor |
| 637 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 638 | Wroughtironandmildsteelladders,framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 639 | Providing and fixing Alloy steel Anchor bolt plates, dashfasteners, angles, channels, shelves and fabrication for Fixing pre -cast slab in fins |
| 640 | Extra rate for steel reinforcement produced by primary producer |
| 641 | Structural Steel Work in highrise fins |
| 642 | Providing, fabricating and erecting in position Structural steel work for girders , beams, trusses , portals, columns, stairs, runners, purlins, bracings, using the rolled steel structural members conforming to grade 355 (Yield Strength in N/mm2) of TATA / CORUS / JINDAL / ESSAR make (conforming to BS EN 100025) in rolled sections such as universal beams, universal columns, channels etc, and in built-up sections including straightening, welding , insert plates and angles with hold fasts etc., of all sizes and shapes and as per detail design, drawings andspecifications for various spans, fillet welding, butt welding as specified in drawings, butt weld splicing, necessary edge preparation for butt welding, etc., all as per specifications and drawings. The weight of bolts and nuts will be paid separately. The rate includes necessarymachining/grinding/smoothening of membersand all weld joints before grid/shot blasting to give a neat and clean appearance. The rate also includes the erection machinery/equipment, temporary supporting structures and members required for erection etc complete. The rate shall include preparation of detail shop drawings on 3D Software TEKLA Structures (X-steel) & Revit .Fabrication can only be taken after approval of shop drawings by Consultant. The contactor shall prepare the connection design calculation and fabrication shop drawings, based on the forces given on the drawings for all the connections / splices, discussing with Architects regardingaesthetics. These shall be approved by the structural consultant before proceeding further.Contactor has also to submitt a complete erection methology of the buiding considering thestability during erection. |
| 643 | Providing, fabricating and erecting in position Structural steel work for girders , beams, trusses , portals, columns, stairs, runners, purlins, bracings, using the rolled steel structural members conforming to grade 355 (Yield Strength in N/mm2) of TATA / CORUS / JINDAL / ESSAR make (conforming to BS EN 100025) in rolled sections such as universal beams, universal columns, channels etc, and in built-up sections including straightening, welding, bending as per architectural radius , insert plates and angles with hold fasts etc., of all sizes and shapes and as per detail design, drawings andspecifications for various spans, fillet welding, butt welding as specified in drawings, buttweld splicing, necessary edge preparation for butt welding, etc., all as per specificationsand drawings. The weight of bolts and nuts will be paid separately. The rate includes necessary machining/grinding/smoothening of members and all weld joints before grid/shot blasting to give a neat and clean appearance. The rate also includes the erection machinery/equipment, temporary supporting structures and members required for erection etc complete. The rate shall include preparation of detail shop drawings on 3D Software TEKLA Structures (X-steel) & Revit .Fabrication can only be taken after approval of shop drawings by Consultant. The contactor shall prepare the connection design calculation andfabrication shop drawings, based on the forces given on the drawings for all theconnections / splices, discussing with Architects regarding aesthetics. These shall beapproved by the structural consultant before proceeding further. Contactor has also tosubmitt a complete erection methology of the buiding considering the stability duringerection. |
| 644 | All steel surfaces shall be abrasive blast cleaned to Sa 2.5(ISO8501-1:1988) or SSPCSP6, using a blend of shot and grit. If oxidation has occurred between blasting and paint application, the surface should be reblasted to the specified visual standard. Any surface defects revealed by the blast cleaning process should be filled/ ground or treated suitably. Surface profile of 40-50 microns (1.5-2 mils) is recommended. Before blasting, surfaces shall be washed and cleaned by waterjet / Solvent to remove surface contamination/ grease etc. The painting work shall be carried out by applicator, approved bymanufacturer. Also manufacturer shall depute their technical representative to inspect andcertify the workmanship & quality of the work at every stage. Contractor shall submit guarantee on Rs.100 Stamp Paper from manufacturer for the executed work for the specified period, against deterioration, loss of gloss, colour, retention etc., as per approved format erection.Painting system for steel structures 2 coat of Zinc rich primer and 2 coat of PU paint colour as per approvals |
| 645 | Providing fabricating and fixing for all connections of steel members MS galvanized bolts, nuts washers, etc of grade 10.9/12.6, of any diameter between M-20 mm to M-40 dia 500mm long with nut and viser etc of grade 10.9 as per IS:1367, this include drill of holes, chemical anchor and chemical from Hilti/Dwalt/Qwik |
| 646 | Providing fabricating and fixing for all connections of steel members MS bolts, nuts washers, etc of grade 10.9/12.6, of any diameter between M20 to M-32 and long 800mm to 1000mm long using for foundationa as per IS:1367. Includes drilling of holes, grouting of |
| 647 | Scaffolding, supports, zigs and fixtures |
| 648 | BUILDING ZONE -5 |
| 649 | EARTH WORK ZONE-5 |
| 650 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 651 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outsidethe building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 652 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer\"s specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 653 | CENTRING AND SHUTTERING WORK |
| 654 | Shuttering for faces of concrete foundations and foundationbeam & plinth beam (vertical or battering) |
| 655 | Centering and shuttering for faces of walls, partitions,retaining walls and the like (vertical or battering) includingattached pilasters, buttresses etc when curved. |
| 656 | Below Ground Floor |
| 657 | Centering and shuttering for columns (Square or rectangularor poly gonal in plain) |
| 658 | Below Ground Floor |
| 659 | Ground Floor |
| 660 | Terrace Floor |
| 661 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 662 | Below Ground Floor |
| 663 | Ground Floor |
| 664 | Terrace Floor |
| 665 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 666 | Below Ground Floor |
| 667 | Ground Floor |
| 668 | Terrace Floor |
| 669 | Centring and shuttering for stair cases with sloping withsoffits including risers and stringers. |
| 670 | Below Ground Floor |
| 671 | Ground Floor |
| 672 | Terrace Floor |
| 673 | CONCRETE WORK |
| 674 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 675 | Conglomerate floor 50mm thick cement concrete rete 1:2:4 on 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material |
| 676 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibratedby needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 677 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibratedby needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 678 | Ground Floor |
| 679 | Terrace Floor |
| 680 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the sameshall be deducted ) |
| 681 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 682 | BRICK WORK |
| 683 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 684 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 685 | Extra for c above 4 meters (where any single storey exceeds 4 metres in height) for every additional height of 2 metres or part thereof for Brick Work/ Concrete Block/ Clay Block. |
| 686 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 687 | Extra for 115mm/100mm thick of walls done above 4 meters (where any single storey exceeds 4 meters in height) for every additional height of 2 meters or parts thereof for Brick Work/ Concrete Block/ Clay Block. |
| 688 | HOISTING AND ROOFING WORK |
| 689 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mmthick cement concrete 1:8:16 |
| 690 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 691 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 692 | Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings specifications and to the entire satisfaction of engineer-in- charge. |
| 693 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allowmovement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 694 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 695 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction ofEngineer-in- charge. |
| 696 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend |
| 697 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction ofEngineer- in- charge. |
| 698 | Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer. |
| 699 | FLOORING AND CLADDING WORK |
| 700 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 701 | Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 702 | Ground Floor |
| 703 | Terrace Floor |
| 704 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material |
| 705 | Ground Floor |
| 706 | Terrace Floor |
| 707 | Extra labour for projected nosing of stair case of any shape and design. |
| 708 | Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. |
| 709 | Precast chequred tiles of 20mm minimum thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base for floors, treads of steps and landings |
| 710 | Ground Floor |
| 711 | Terrace Floor |
| 712 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 713 | Ground Floor |
| 714 | Terrace Floor |
| 715 | Kota stone slab 20-25 mm thick flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbingand polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 716 | Ground Floor |
| 717 | Terrace Floor |
| 718 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, includingrubbing and polishing |
| 719 | Ground Floor |
| 720 | Terrace Floor |
| 721 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 722 | Ground Floor |
| 723 | Terrace Floor |
| 724 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 725 | Providing and fixing copper pins 7.5 cm long 6mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases |
| 726 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 727 | Ground Floor |
| 728 | Terrace Floor |
| 729 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 730 | Ground Floor |
| 731 | Terrace Floor |
| 732 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 733 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 734 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Bansi Paharpur Stone - Exposed face machine cut & table rubber with rough backing40mm thick |
| 735 | PLASTER AND POINTING WORK |
| 736 | 10mm thick Cement Plaster 1:4 |
| 737 | Ground Floor |
| 738 | Terrace Floor |
| 739 | 12.5 mm thick cement plaster 1:5 |
| 740 | Ground Floor |
| 741 | Terrace Floor |
| 742 | 20mm thick cement plaster 1:5 in two coat work |
| 743 | Ground Floor |
| 744 | Terrace Floor |
| 745 | PAINTING WORK |
| 746 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 747 | Ground Floor |
| 748 | Terrace Floor |
| 749 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 750 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 751 | Ground Floor |
| 752 | Terrace Floor |
| 753 | Spirit polishing two coats including a coat of wood filler on wood work |
| 754 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 755 | Ground Floor |
| 756 | Terrace Floor |
| 757 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 758 | WOOD WORK |
| 759 | Chowkats of Imp. Teak Woodconfirming to ISI specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops bolts for hold fasts etc, complete fixed in position (Section 60mm x 150mm)Double Rebate (60mm x 150mm) (60mm x 150mm) |
| 760 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1) (1999) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 761 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 762 | Providing and fixing teak wood beading to door windows chowkats with iron screws fixed in position complete as per design and shape required 50mmx12mm |
| 763 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 764 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and makingnecessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge |
| 765 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm |
| 766 | Providing & fixing 46mm thick fully flush double skin fire door shutter of 120 minutes fire rating confirming to IS:3614(Part II),tested & certified by CBRI (Roorki). Door frame & leaf shall be manufactured from 1.6mm (16 gauge) & 1.2mm (18guage) minimum thick galvanised steel sheet.The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. The edges should be interlocked with lock seam. All doors shall be finished with polyurethane aliphatic grade paint of approved colour. The door shall have passed minimum 250 hours of salt spray test. |
| 767 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casementhandles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall bepaid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension on higher side shall be accepted but no extra payment on this account shall be made. |
| 768 | Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series)frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and singleglazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). |
| 769 | Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension.(Area upto 0.75 sqm) |
| 770 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. |
| 771 | For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 772 | Providing and fixing aluminum grill 6.3 mm including cost of necessary fittings i.e. screws,u Type Beading etc. complete |
| 773 | Providing and fixing aluminum Wire Mesh including cost of necessary fittings i.e. screws,u Type Beading etc. complete |
| 774 | Providing & Fixing AMBRE-FAMELINE Aluminium 750 AF Louvre is a special type of louver with width of 150mm. The thickness of the aluminium sheet is 1.2mm and with the total length of 0.6meters of each panel. The Aluminium 750 AF Louvre then attached to the special extruded frame with length of 6meters support which incorporated to the main frame of glass to provide firmness and stability. The panel are locked by a special pin in Stainless Steel 304, in a module of C/C finalize by the architect. PAINT FINISH: Electrostatically Polyester Powder Coating Gloss Level 35%, minimum Thickness 60 micron tested according to ASTM B 117. Or Electrostatically Baked Enamel Spray Painting (Acrylic resin) Gloss Level 35%, minimum Thickness 30 micron. Paint is as per AMBRE-FAMELINE exterior paint finish as per manufacturer\"s specification. |
| 775 | Providing and Fixing Toilet Cubicles System made of 12mm thick compact laminated board size as per drawing x 2100mm, door siize 600mm x 1750mm over all height cubicals 2100mm including bottom gap of 150mm excessary SS 304 Grade such as U channel, F Channel, SS Top rail, SS coat huk, SS Privacy thumb turn SS Door Knob, SS Hing with cover, SS adjustable foot, rubber linning for groove screws and PVC Wall plug merino Make or euivalantcomplege in all respect as per specification and as desired by engineer in charge] (Payment to be made per square meter of the partition including doors) |
| 776 | STEEL WORK |
| 777 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 778 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 779 | Below Ground Floor |
| 780 | Ground Floor |
| 781 | Terrace Floor |
| 782 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 783 | Extra rate for steel reinforcement produced by primary producer |
| 784 | BUILDING NAME : EXTERNAL DEVELOPMENT WORK |
| 785 | Earth Work |
| 786 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 787 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating leadupto 30 metres |
| 788 | Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications. |
| 789 | CONCRETE WORK |
| 790 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concretemixer volumetric type |
| 791 | Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type |
| 792 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steelreinforcement centring and shuttering in foundation and plinth |
| 793 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steelreinforcement centring and shuttering in superstructure. |
| 794 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded |
| 795 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone |
| 796 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted ) |
| 797 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 798 | CENTRING AND SHUTTERING |
| 799 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 800 | Centering and shuttering for faces of walls, partitions,retaining walls and the like (vertical or battering) includingattached pilasters, buttresses etc when curved. |
| 801 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 802 | Centering and shuttering for flat surfaces such assuspended floors, roofs, landings, chajjas, shelves etc. |
| 803 | BRICK WORK |
| 804 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 805 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 806 | HOISTING AND ROOFING WORK |
| 807 | Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
| 808 | Sand filling under floor and in wells of bridge foundation including handling withing 100 metres |
| 809 | Corrugated G.I. Sheet roofing 0.80 mm thick fixedwith galvanized iron J or L hooks 10mm dia, G.I.Limpot and bitumen washers complete excludingthe cost of purling rafters and trusses |
| 810 | FLOORING AND CLADDING WORK |
| 811 | SLOPE/PROTECTION SCREED OF 75 MM :Providing and laying weld-mesh reinforced or on renforced depending on site condition screed over the boards The slope built-up cum protection layer shall have a average thickness of 75 mm with a slope gradient of 1:100. It shall be laid to the required slope, level and finish as directed including curing by ponding for a minimum of 7 days. Of mini M20 grade concrete screed to be used. |
| 812 | Kota stone slab 20-25 mm thick flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 813 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 814 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 815 | Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved byEngineer-in-Charge: |
| 816 | Providing and fixing of white river (Stone) pebbles size of 2\" to 2.50\" dia in natural colour at site of work including loading, unloading and carriage |
| 817 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Bansi Paharpur Stone - Exposed face machine cut & table rubber with rough backing40mm thick |
| 818 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 819 | Providing and fixing copper pins 7.5 cm long 6mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases |
| 820 | PLASTER WORK |
| 821 | 20mm thick cement plaster in 1:5 in two coats work. |
| 822 | PAINTING WORK |
| 823 | Finishingwallswithacrylic smoothexterior paint of required shade with two coats applied @ 1.67 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm |
| 824 | Applying priming coat with metal primer onnew steel or iron work including preparation of surface. (with special quality paint) |
| 825 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 826 | STEEL WORK |
| 827 | Structural steel work in angles, tees, flats, riveted, including cutting, fixing all gusset plates, bolts, nuts, rivets etc. with hoisting and erecting in position. For plates and trussed girders etc. for bridge of span more than 15 metres but upto 30 mts. Span including cost of all machinery i.e hydra crane etc |
| 828 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 829 | Extra rate for steel reinforcement produced by primary producer |
| 830 | ROAD WORK |
| 831 | Compaction of earth work & Preparation of subgrade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers) |
| 832 | Construction of embankment with good quality earth obtainedfromborrowpitsincluding compensationofearth,loading,unloading, carriage to siteof work, spreading, grading to requiredslope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications (Lead-5.00km) |
| 833 | Construction of granular sub-base by providing material, spreading in uniform layers with motorgrader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications |
| 834 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications |
| 835 | Providing and applying primer coat with bitumenemulsion SS on prepared surface of granularbase including cleaning of road surface andspraying primer at the rate of 0.85kg/sqmcomplete as per technical clause 502 of MORT&Hspecifications |
| 836 | Providing and applying tack coat with penetration grade bitumen VG-10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical specifications |
| 837 | Providing and laying bituminous macadam 50mm to 75mm thick with batch type hot mix plant using crushed aggregates of specified grading premixedwith bituminous binder VG-30 @3.4%, laid over a previously prepared surface with hydrostatic paver finisher with sensor control to the required grade, level and alignment and rolled to achieve the desired compaction complete as per technical clause 504 of MORT&H specifications |
| 838 | Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified gradingpremixed in a Continuous type hot mix plant with bituminous binder VG-30 @ 1.46kg per sqm, laid with Paver Finisher Mechanical and rolling with asmooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 510 of MORT&H specifications |
| 839 | Providing and laying of premix sand seal coat premixed in Continuous type hot mix plant using specified fine aggregates and penetration grade bitumen VG-30 @ 0.68kg per sqm, laid to the specified levels, grade and cross fall complete as per technical clause 511 of MORT&H specifications |
| 840 | Providing & erecting \"W\" type metal beam crash barrier single sided comprising of 3mm thick corrugated sheet metal beam rail 70cm aboveroad or ground level fixed on channel vertical post 150x75x5mm spaced 2mtr centre to centre 1.80mtr high, 1.1mtr below road or ground level,all steel parts and fitments to be galvanized by hot dip process, all fittings to conform to IS:1367 & IS:1364, metal beam rail to be fixed on the verticalpost with a spacer of channel section 150x75x5mm, 330mm long fixed firmly into ground with vertical hydraulic self driving machine forvertical post complete as per approved drawings and technical clause IRC: 119-2015. |
| 841 | Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications |
| 842 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 843 | Extra rate for steel reinforcement produced by primary producer such as SAIL/TATA/RINL |
| 844 | Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
| 845 | Sand filling under floor and in wells of bridgefoundation including handling withing 100 metres |
| 846 | HORTICULTURE WORK |
| 847 | Fine grassing including uprooting rank vegetation and weeds by digging the area to a depth of 30 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days, mixing fertilizer and then fine dressing forplanting new grass, including disposal of allrubbish with all leads and lifts, watering, weeding and maintenance for 30 days or till thick lawn is formed. Planting Selection no. 1 grass roots in rows 10 cm apart in both directions. |
| 848 | MS circular tree guard with wire mesh, having 4 No. legs of angle iron size 25x25x3mm, 1.80 mtr. height, 3 No rings of M.S Flats of 25 x 6 mm, 60cm dia andfixing of wire mesh size 50x75mm. Tree guard in two halves bolted together with 8mm dia & 30 mm long bolts, and fixing 250 mm X 100 mm iron plate, fixed inground with 1:2:4 cement concrete, complete in all respects. |
| 849 | Supplying and planting permanent trees in prepared pits and watering |
| 850 | Supplying and planting permanent shrubs in prepared pits and watering |
| 851 | Supplying and planting of ornamental trees (1\"-0\" height sapling) includingfilling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . |
| 852 | Azadirachtha indica/Neem |
| 853 | Delonix regia/ Gulmohur |
| 854 | Kigelia pinnata/ Sausage tree |
| 855 | Peltophorum ferrugineum |
| 856 | Spathodea campanulate/ Fountain tree |
| 857 | Plumeria alba/ Temple tree, Champa |
| 858 | Maintenance of tree including fertilization, application of insecticide, watering, weeding, training, pruning, disposal of debris and other activities. |
| 859 | Maintenance of trees for the 1st year |
| 860 | Maintenance of trees for the 2nd year |
| 861 | Maintenance of trees for the 3rd year |
| 862 | Maintenance of trees for the 4th and 5th year (Cost per year) |
| 863 | Supplying and planting ofshrubs includingfilling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . |
| 864 | Barleria cerstata |
| 865 | Dwarf allamanda |
| 866 | Dwarf nerium oleander |
| 867 | Dwarf hibiscus |
| 868 | Lemonia |
| 869 | Tab verigated |
| 870 | Ficus Longisland |
| 871 | Maintenance of shrubs for one year including training, pruning, fertilization, application of insecticide, watering and weeding. |
| 872 | Individual shrubs |
| 873 | Providing and fixing of white river (Stone) pebbles size of 2\" to 2.50\" dia in natural colour at site of work including loading, unloading and carriage |
| 874 | Substation |
| 875 | EARTH WORK |
| 876 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 877 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outsidethe building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 878 | Earth filling under floors with surplus soil containing more than 40% taking outside the premises in 15 cm layers including ramming watering and consolidated lead upto 1000 metres |
| 879 | CENTRING AND SHUTTERING WORK |
| 880 | Shuttering for faces of concrete foundations and foundationbeam & plinth beam (vertical or battering) |
| 881 | Centering and shuttering for columns (Square or rectangularor poly gonal in plain) |
| 882 | Ground Floor |
| 883 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 884 | Ground Floor |
| 885 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 886 | Ground Floor |
| 887 | CONCRETE WORK |
| 888 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 889 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibratedby needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 890 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the sameshall be deducted ) |
| 891 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 892 | BRICK WORK |
| 893 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 894 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 895 | HOISTING AND ROOFING WORK |
| 896 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mmthick cement concrete 1:8:16 |
| 897 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction ofEngineer-in- charge. |
| 898 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend |
| 899 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction ofEngineer- in- charge. |
| 900 | Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer. |
| 901 | FLOORING AND CLADDING WORK |
| 902 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 903 | Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 904 | Ground Floor |
| 905 | PLASTER AND POINTING WORK |
| 906 | 12.5 mm thick cement plaster 1:5 |
| 907 | Ground Floor |
| 908 | 20mm thick cement plaster 1:5 in two coat work |
| 909 | Ground Floor |
| 910 | PAINTING WORK |
| 911 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 912 | Ground Floor |
| 913 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 914 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 915 | WOOD WORK |
| 916 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sideswith required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointedmechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats |
| 917 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thickness |
| 918 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. |
| 919 | For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 920 | STEEL WORK |
| 921 | Supplying and fixing rolling shutters, ofapproved make, made of 80mmx1.25mm,M.S. Laths, interlocked together throughtheir entire length and jointed together, atthe end, by end locks, mounted onspecially designed pipe shaft, withbrackets, side guides, 27.5cm long wirespring grade No. 2 and arrangement forinside and outside locking with push andpull operation complete, including topcover 0.80mm thick (payment is to be made for the exact size of opening whererolling shutter is to be fixed)c |
| 922 | Extra for providing mechanical device,chain and crank operation, for operatingrolling shutter, exceeding 11.20 sqm inarea, of the rolling shutter |
| 923 | Wroughtironandmildsteelladders,framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 924 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 925 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 926 | Below Ground Floor |
| 927 | Meter Room |
| 928 | EARTH WORK |
| 929 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 930 | CENTRING AND SHUTTERING WORK |
| 931 | Shuttering for faces of concrete foundations and foundationbeam & plinth beam (vertical or battering) |
| 932 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 933 | Ground Floor |
| 934 | CONCRETE WORK |
| 935 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 936 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 937 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the sameshall be deducted ) |
| 938 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 939 | BRICK WORK |
| 940 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 941 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 942 | HOISTING AND ROOFING WORK |
| 943 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mmthick cement concrete 1:8:16 |
| 944 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction ofEngineer-in- charge. |
| 945 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend |
| 946 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction ofEngineer- in- charge. |
| 947 | Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer. |
| 948 | FLOORING AND CLADDING WORK |
| 949 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 950 | Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 951 | PLASTER AND POINTING WORK |
| 952 | 12.5 mm thick cement plaster 1:5 |
| 953 | 20mm thick cement plaster 1:5 in two coat work |
| 954 | PAINTING WORK |
| 955 | White washing (Three coat) |
| 956 | STEEL WORK |
| 957 | Wroughtironandmildsteelladders,framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 958 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 959 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 960 | PUBLIC HEALTH |
| 961 | PART-I INTERNAL WORKS (A) CSR ITEM |
| 962 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm diaincluding cost ofseat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 963 | Providing and fixing jet spray with 2\"-6\" long PVC pipe.With C.P. Brass nut |
| 964 | Providing and fixingin position CP Brass Grab Barof approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect. |
| 965 | Providing and fixingin position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge)consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.Size 550 mm x 400 mm x 815 mm |
| 966 | Providing and fixing in position C.P brass basin mixer without pop-up waste system with 450 mm long flexible hose of approved make (to the approval of Engineer-in-charge) instead of C.P. brass pillar tap complete in all respect. |
| 967 | Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-in-charge)complete in all respect. |
| 968 | Providing & fixing in position C.P brass Sink mixer swivel spout (Wall mounted) of approved make (to the approval of Engineer-in-charge)complete in all respect. |
| 969 | Providing and fixingin position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inletof approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 970 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backingfixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on topcomplete in all respect (as required by the Engineer-in- Charge) Size 550mmx400mm |
| 971 | Providing and fixingin position stainless steel sinksof approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.Rectangular Sink with Deluxe Border Single Bowl Overall Size 555 mm x 475mm x 200 mm |
| 972 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 973 | Providing and fixingin position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.C.P. brass toilet paper holder |
| 974 | Providing and fixingin positiontowel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 975 | C.P. brass towel Rails size 15mm dia 610mm long |
| 976 | C.P brass towel ring |
| 977 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 3 pegs |
| 978 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 979 | C.P. brass Bib cock long nose/ long body foam flow without flange |
| 980 | C.P. brass Bib cock foam flow without flange |
| 981 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 982 | C.P.brass 15mm Concealed stop cock with flange. |
| 983 | C.P.brass 15mm Angle valve without flange |
| 984 | Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. brass liquid soap container |
| 985 | Providing & fixing in position PVC flexible tube connectionof approved make (to the approval of Engineer-in-charge ) complete in all respect.PVC tube connection of size 15 mm x 375 mm with PTMT nut |
| 986 | Providing and fixingin position C.P. brass soap dishof approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 987 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge)consisting of C.P. brass Urinal waste Couplingdome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm longcomplete. |
| 988 | Vitreous white Chinaware PartitionSmall partitions size 69x 16.5 x 32.5 cm |
| 989 | Providing and fixing in postion storage type automatic electric water heater pressure / non pressure type thermostatically controlled, single phase, vertical wall mounted of approved make (to the approval of Engineer-in-charge)with thermostats, inner container of stainless steel complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. |
| 990 | 25 litre capacity water heater |
| 991 | 50 litre capacity water heater |
| 992 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 993 | Sub Work-2 Soil Waste, Vent & Fittings |
| 994 | Providing lead caulked joints to H.C.I. pipes and specials conforming to I.S.I. Specification of E.L.C. manufacture or any other reputed firm including cost of lead yarn,fuel and toolsetc. |
| 995 | 100mm i/d (1.36 kg.) |
| 996 | 75mm i/d (1.13 kg.) |
| 997 | Providing & Fixing in position M.S or heavy flat iron clamps made out ofM.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. M.S. Holder bats clamps for 100mm i/d H.C.I. pipes |
| 998 | Providing and fixing in position H.C.I special for soil waste vent or anti syphonage pipes to I.S.I specifications of E.L.C manufacture or any other reputed firm including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 100mm i/d pipes |
| 999 | 100mm i/d door Bend |
| 1000 | 100mm i/d Bend plain |
| 1001 | 100mm i/d H.C.I. Heal Rest Bend |
| 1002 | 100mm i/d Door Tee |
| 1003 | 100mm i/d Plain Tee |
| 1004 | 100mm i/d Cowls |
| 1005 | 100mm i/d Collars |
| 1006 | 100mm i/d P-Trap |
| 1007 | Providing ,laying, jointing, fixing and testing ISI MarkedG.I. Pipe (as per IS 1239) B-Class including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. |
| 1008 | 32mm i/d |
| 1009 | 50mm i/d |
| 1010 | Providing drip seal joint to H.C.I. pipes and specials including cost of drip seal, yarn and tool etc. of approved mate to the approval of Engineer in Charge. 100mm i/d |
| 1011 | Sub Work-3 Rain Water Pipes and Fittings |
| 1012 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type A |
| 1013 | 160mm o/d single socket SWR UPVC pipe lines laid complete |
| 1014 | 110mm o/d single socket SWR UPVC pipe lines laid complete |
| 1015 | Providing & Fixing in position M.S or heavy flat iron clamps made out ofM.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. |
| 1016 | M.S. Holder bats clamps for 100mm i/d H.C.I. pipes |
| 1017 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm o/d pipesElbow 90 Degree (All side socketed) |
| 1018 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. DSR-2014 12.44 |
| 1019 | Sub Work-4 Water Supply |
| 1020 | INTERNAL -EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 1021 | SDR 11 CPVC pipes & fittings 16mm o/d |
| 1022 | SDR 11 CPVC pipes & fittings 20mm o/d |
| 1023 | SDR 11 CPVC pipes & fittings 25mm o/d |
| 1024 | SDR 11 CPVC pipes & fittings 32mm o/d |
| 1025 | SDR 11 CPVC pipes & fittings 40mm o/d |
| 1026 | SDR 11 CPVC pipes & fittings 50mm o/d |
| 1027 | Providing ,laying, jointing, fixing and testing ISI MarkedG.I. Pipe (as per IS 1239) B-Class including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. |
| 1028 | 15mm i/d |
| 1029 | 20mm i/d |
| 1030 | 25mm i/d |
| 1031 | 32mm i/d |
| 1032 | 40mm i/d |
| 1033 | 50mm i/d |
| 1034 | Providing and laying, jointing, fixing, testing ISI MarkedG.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. |
| 1035 | 25mm i/d |
| 1036 | 32mm i/d |
| 1037 | 40mm i/d |
| 1038 | 50mm i/d |
| 1039 | 65mm i/d |
| 1040 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879in G.I. Pipe lines complete in all respect. |
| 1041 | 15mm i/d G.I. Union |
| 1042 | 20mm i/d G.I. Union |
| 1043 | 25mm i/d G.I. Union |
| 1044 | 32mm i/d G.I. Union |
| 1045 | 40mm i/d G.I. Union |
| 1046 | 50mm i/d G.I. Union |
| 1047 | Providing, fixing and jointing ISI MarkedGun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. |
| 1048 | 15mm i/d Gun Metal peet valve heavy pattern. |
| 1049 | 20mm i/d Gun Metal peet valve heavy pattern. |
| 1050 | 25mm i/d Gun Metal peet valve heavy pattern. |
| 1051 | 32mm i/d Gun Metal peet valve heavy pattern. |
| 1052 | 40mm i/d Gun Metal peet valve heavy pattern. |
| 1053 | 50mm i/d Gun Metal peet valve heavy pattern. |
| 1054 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. Size 75 mm x 50 mm |
| 1055 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 1056 | Through wall 11.43 cm thick |
| 1057 | Through wall 22.86 cm thick |
| 1058 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 1059 | Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal |
| 1060 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 1061 | Sub Work-5 Internal Works |
| 1062 | INTERNAL WORKS ALL N.S. ITEMSProviding and fixing to the basement ceiling M.S. clamps/supports fabricated form M.S. structural steel consisting of channels, angle iron, M.S. rods, nuts, bolts and washers, fixed to the basement ceiling with expansion fasteners including painting of supports with an enamel paint over a coat of primer complete in all respects.(Sample of structural clamp to be submitted for approval before installation). (Soil, Water & Fire Pipes) |
| 1063 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B160mm o/d SWR UPVC pipe lines laid complete |
| 1064 | Providing and laying, jointing, fixing, testing ISI MarkedG.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. |
| 1065 | 65mm i/d |
| 1066 | 80mm i/d |
| 1067 | Constructing brick masonry water tight grease trap (with three chambers , each of 0.4 M X 0.6 M in plan) with 75 class designation bricks in cement mortar 1 : 5 ( 1 cement : 5 fine sand ) earth work, excavation in all kinds of soil, foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including constructing baffle wall, stainless steel angles on corners, stainless steel perforated plates with stainless steel lifting handles in each chamber,inlet and outlet fittings in UPVC, double seal C.I. covers complete as per standard design: |
| 1068 | Inside size 2.0m x 1.5m and 1.0m deep including two nos. 60x60 cm. C.I. Cover and frame (double seal weight of cover and frame not less than 75 kg) |
| 1069 | PART-I EXTERNAL WORKS (A) CSR ITEM |
| 1070 | Sub Work-1 Water Supply |
| 1071 | Providing and laying, jointing, fixing, testing ISI MarkedG.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. |
| 1072 | 25mm i/d |
| 1073 | 32mm i/d |
| 1074 | 40mm i/d |
| 1075 | 50mm i/d |
| 1076 | 65mm i/d |
| 1077 | 80mm i/d |
| 1078 | Providing, fixing and jointing ISI MarkedGun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. |
| 1079 | 25mm i/d Gun Metal peet valve heavy pattern. |
| 1080 | 32mm i/d Gun Metal peet valve heavy pattern. |
| 1081 | 40mm i/d Gun Metal peet valve heavy pattern. |
| 1082 | 50mm i/d Gun Metal peet valve heavy pattern. |
| 1083 | 65mm i/d Gun Metal peet valve heavy pattern. |
| 1084 | Supplying, Laying, Testing and Commissioning ofISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked completewith rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 1085 | 80 mm i/d |
| 1086 | 100 mm i/d |
| 1087 | 150 mm i/d |
| 1088 | Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring. |
| 1089 | D.I. Pipe as per IS 8329 DI-K7 |
| 1090 | 80mm i/d pipe lines laid complete |
| 1091 | 100mm i/d pipe lines laid complete |
| 1092 | Supplying andlaying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding, tools and plants, ropes, guys, etc. Complete in all respects.D.I. specials upto 300mm i/d |
| 1093 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 1094 | Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal |
| 1095 | 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal |
| 1096 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cuttingin streets or open areaincluding trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.Earth work upto 1.5 m. Depth forAll classes of soil except rocky |
| 1097 | Sub Work-2 Sewerage System |
| 1098 | Providing, Laying , fixing & jointing ofP.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. |
| 1099 | 110mm o/d pipe of 8 Kgf. / sqcm |
| 1100 | 160mm o/d pipe of 8 Kgf. / sqcm |
| 1101 | 200mm o/d pipe of 8 Kgf. / sqcm |
| 1102 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc.as per standard design minimumdepth of water should be 150 mm with a minimum seal 50mm. |
| 1103 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 1104 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards,fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works,upto one chain (15m) complete in all respects.Depth not exceeding 3 m. BGLAll kinds of soil except rocky |
| 1105 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 1106 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 1107 | 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal |
| 1108 | Extra for every 0.30 metre depth of inspection chamber. |
| 1109 | 450mm x 600mm inside |
| 1110 | 600mm x 900mm inside |
| 1111 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 1112 | Inside size 75x120 cm and 120 cm deep |
| 1113 | Inside size 90x150 cm and 120 cm deep |
| 1114 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 upto1.80 m increase in depth. |
| 1115 | Inside size 75x120 cm |
| 1116 | Inside size 90x150 cm |
| 1117 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 beyond 1.80 m upto 3.60 m beyond addiational depth.Inside size 90x150 cm |
| 1118 | Sub Work-3 Storm Water Drainage System |
| 1119 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards,fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works,upto one chain (15m) complete in all respects. |
| 1120 | Depth not exceeding 3 m. BGLAll kinds of soil except rocky |
| 1121 | Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting ofreinforced cement concrete spigot and socketedpipes and specials with rubber ringISI marekd as per IS code IS 458-2003into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc.R.C.C. Pipe NP -3 |
| 1122 | 150mm i/d pipe |
| 1123 | 250mm i/d pipe |
| 1124 | 300mm i/d pipe |
| 1125 | 400mm i/d pipe |
| 1126 | 450mm i/d pipe |
| 1127 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 1128 | Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal |
| 1129 | 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal |
| 1130 | Extra for every 0.30 metre depth of inspection chamber. |
| 1131 | 450mm x 450mm inside |
| 1132 | 600mm x 900mm inside |
| 1133 | Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick C.C 1:6:12in foundation, first class brick work laid in cement sand mortar 1:5, 40mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12.50mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1mm thick left absolutely smooth polished and correct to template including cost of precasted RCC road gully grating and frame including paint with coal tar (as specified in item No. 29.49)complete and to the requirement of the Engineer-In-Charge. Single Road Gully chamberSize 610mm x 457mm x 800mm |
| 1134 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 1135 | Inside size 75x120 cm and 120 cm deep |
| 1136 | Inside size 90x150 cm and 120 cm deep |
| 1137 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 upto1.80 m increase in depth. |
| 1138 | Inside size 75x120 cm |
| 1139 | Inside size 90x150 cm |
| 1140 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 beyond 1.80 m upto 3.60 m beyond addiational depth.Inside size 90x150 cm |
| 1141 | Sub Work-4 Pumping System |
| 1142 | PUMPING SYSTEMProviding, fixing, testing and commissioning of Vertical in line type pump set with SS casing, SS impeller and SS shaft suitable for operation on 400/440 volts, 3 phase 2900 RPM, TEFC electric motor mounted on a common channel base plate with coupling guard, 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster complete as required.( Including control panel board cosisting ofvoltmete,r amps MCB etc. and earthing as per speicification complete in all respects.) a) Irrigation water supply pumpsPump capacity - 400 lpmHead- 40 mRPM - 2900 |
| 1143 | Providing, fixing and commissioning non clog type mono block submersible drainage pumps suitable for handling solids of 12 mm size with totally water and dust proof motor as specified.( Including control panel board cosisting ofvoltmete,r amps MCB etc. and earthing as per speicification complete in all respects.) |
| 1144 | Capacity 500 lpm & Head 15 m (in basement)(9 nos. working + 1 no. spare) |
| 1145 | Capacity 300 lpm & Head 15 m (in pumproom) |
| 1146 | Providing, fixing and commissioning non clog type mono block submersible sewage pumps suitable for handling solids of 32 mm size with totally water and dust proof motor as specified . |
| 1147 | Capacity 100 lpm & Head 15 m (in basement)(2 nos. working + 1 no. spare) |
| 1148 | Supplying and laying the PVC insulated & sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor on prelaid cabel trays including supplying and making and termination with brass compression glands: (cabel trays shall be installed by electrical cotrator). |
| 1149 | 3 Core x 4 sq.mm |
| 1150 | 3 Core x 6 sq.mm |
| 1151 | Supply, assembly, erection, testing and commissioning ofdiaphragn type dosing chlorinator with metering pump mounted on 500 litres capacity HDPE tank and suitable for operation on 220 ± 5% single phase, 50 Hz AC supply, competein all respects. a)Suitable for flow rate 18000 lph |
| 1152 | Sub Work-5 SUCTION AND DELIVERY PIPES AND VALVES FOR WATER SUPPLY PUMPS |
| 1153 | Providing, laying, fixing, testing and commissioning of \"C\" Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 1154 | 50mm internal diameter |
| 1155 | 80mm internal diameter |
| 1156 | 100mm internal diameter |
| 1157 | Supplying, Laying, Testing and Commissioning ofISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked completewith rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 1158 | 50 mm i/d |
| 1159 | 80 mm i/d |
| 1160 | 100 mm i/d |
| 1161 | Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines includingjointing & cost of Nut Bolt , rubber insertion etc.complete. |
| 1162 | 50 mm nominal bore |
| 1163 | 80mm i/d check valve . |
| 1164 | 100mm i/d check valve |
| 1165 | Sub Work-6 Tubewell & Tubewell Pumps (1 Nos) |
| 1166 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. |
| 1167 | 200mm nominal diameter (weight 41.6 kg per metre) 8.0 mmthickness |
| 1168 | Supplying at siteofgravel of 1/16\" to 1/8\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) |
| 1169 | Supplying, commissioning and testing of submersible pumping set suitable for bore 200 mm dia, discharge 300 LPM including cost of supplying and lowering double flanged G.I. \"B\"class column pipe of suitable size (upto 170 metre length)The rate shall also including cost of submerssible 4 sqmm cooper cable 3 core of approved make from ground with submersible pumpingset complete in all respect .(NOTE:- This rate is only for estimate / BOQ Purpose. Payment will be made as per rate approved by Engineer in Charge as per actual strata chart approved) |
| 1170 | 1 No. of pump set head 200 Mtr , Discharge 300 LPM. (1 no. working & 1 no. stand by) |
| 1171 | Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 1172 | Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 1173 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cuttingin streets or open areaincluding trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.Earth work upto 1.5 m. Depth forAll classes of soil except rocky |
| 1174 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879in G.I. Pipe lines complete in all respect.80mm i/d G.I. Union |
| 1175 | Providing, fixing and jointing ISI MarkedGun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.80mm i/d Gun Metal peet valve heavy pattern. |
| 1176 | GALVANIZED IRON PIPES AND G.I. EARTHING:Earthing of Sheet metal/ iron clad Switches and metallic cases etc ., with No. 7/12 S.W.G. (7/2.18mm dia.) G.I. wire in20mmdiaG.I.pipepartlyrecessedandpartlyon surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling). |
| 1177 | Supplying and laying C.I. specials as per IS:1538 complete as desired by Engineer-in-Charge conforming to ISI specifications.Note: If C.I specials of ISI Marked is used intead of specials confirming to ISI Specifications , than 10% extra on ratesof this item will be paid.C.I. specials upto 300mm i/d |
| 1178 | Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing , cost of nut bolts & rubber insertion all carriages complete.C.I Single air valve screwed (Size 25mm) |
| 1179 | Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004in pipe lines includingjointing & cost of Nut Bolt , rubber insertion etc.complete.Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5%will be paid extra.Class PN-1.0 as per ISI with rubber Flap80mm i/d Non-return valve |
| 1180 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working partsSluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet,all carriage complete (with the approval of Engineer in-charge).Class PN-1 as per ISI80mm i/d Sluice Valves flanged |
| 1181 | Providing and laying, jointing, fixing, testing ISI MarkedG.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.40mm i/d |
| 1182 | Providing, fixing and jointing ISI MarkedGun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.40mm i/d Gun Metal peet valve heavy pattern. |
| 1183 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standarddesign & drawings of public health department.Size 0.9 m. x 0.9 m. |
| 1184 | Sub Work-7 Sewerage Treatment Plant |
| 1185 | SEWAGE TREATMENT PLANT 120 KLDDesign Supply, erection, testing and commissioning of sewage treatment plant based on attached Growth system working on the principle of Fluidized Aerobic Bio-reactor process based on the FAB processPH : 7.0 - 8.0S. Solids : 250 mg/lCOD : 450 mg/lOil & Grease: 15 mg/lColiform: 10^6- 10^7 counts / 100 mlEffluent discharge standard after treatment:Conforming to requirement approved standardsPH : 7.0 - 8.0BOD 5: Less than 6 mg/lS. solids : Less than 30mg/lCOD : Less than 150 mg/lOil & Grease: Less than 10 mg/lOutlet Coliform : < 1000 counts / 100 ml |
| 1186 | Sewage treatment plant shall include supply erection, testing & commissioning of the following items: Ssuch as bar screen, sewage lifting pumps of designed capacity and speicification, submersible drainage pumps, air blowers including air grids, media for tube settler as per designed requirement, treated water pumps, filter press and filter press feed screw pumps, pipe lines and valves, waste water treatement of appropriet technology and any other item required as per design complete in all respect to be satisfection of engineer-in-charge. The cost also include O &M of STP for a period of one year after commissioning. All spares and replacement of any defective part shall be included in the controct. |
| 1187 | Sub Work-9.1 Recharging Well with Bore Hole |
| 1188 | Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopesto full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects.Depth upto 1.5 m B.G.LAll classes of soil except rocky |
| 1189 | Earth fillingEarth work (exclusive of compensation for earth) in excavation in ordinary soil or soil containing gravel or kankar upto 40% and filling in 15 cm layers in foundation and plinth including ramming watering and consolidating under floors with earth brought from a distance not exceeding 30 metres |
| 1190 | Sub Work-9.2 Concrete Work |
| 1191 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type |
| 1192 | Cement concrete 1:3:6 with stone ballast or shingle 40 mm guage. using concrete mixing volumetric type |
| 1193 | Reinforced cement concrete M-25mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 1194 | Sub Work 9.3 Centering and Shuttering |
| 1195 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 1196 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 1197 | Sub Work-9.4 Brick Work |
| 1198 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 1199 | Sub Work 9.5 Plaster Work |
| 1200 | 12.5mm thick cement plaster 1:5. |
| 1201 | Sub Work 9.6 Steel Work |
| 1202 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 1203 | Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).RCC Man hole cover with Frame560mm i/d RCC man hole cover with frame as per ISIHeavy duty |
| 1204 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 1205 | Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting ofreinforced cement concrete spigot and socketedpipes and specials with rubber ringISI marekd as per IS code IS 458-2003into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc.R.C.C. Pipe NP -3200mm i/d pipe |
| 1206 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer – in-charge, upto 90 metre depth below ground level.All types of soil.400 mm dia. |
| 1207 | Providing, laying in trenches to correct gradient and alignment and jointing ofUPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.160mm o/d pipe |
| 1208 | Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:-Third Layer :----- Bajri screened, cleaned and washed and graded from6mm to 20mm (from Pathankot or approved equivalent quarry). |
| 1209 | Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:-Second Layer :----- Coarse sand screened, cleaned and washed and graded from 3mm to 6mm (from Pathankot or approved equivalent quarry). |
| 1210 | Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:-Top Layer:Top layer :----- Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4mm with uniformity coefficient 2.00 to 3.00) from Pathankot or other approved source. |
| 1211 | Supplying at siteofgravel of 1/16\" to 1/8\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) |
| 1212 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer -in-charge. |
| 1213 | Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect.200mm internal diameter (weight 41.6 kg per metre) 8.0 mmthickness |
| 1214 | Sub Work 9.9 Water Features with 5 Nos Cascade Jet |
| 1215 | Water Features with 5 nos cascade JetSkimmer Type Area : 140 m2 x 0.3 m depthTotal Pool Volume: 42 m3Filteration Flow rate: 14.0m3/hr Filtration Plant with PumpBobbin Wound PolysterFibre Glass , Filtration Velocity : 30 m3/hr/m2 Dia. 750 mm working pressure 2.5 kg/cm2 Flow rate: 14 m3/hr outletconnection 63 mm , complete with pressure gauge,manual bleeder,water drain,empty drain for filter media with 500mm bed depth with media ( 450 Kgs) |
| 1216 | Make : AtecPool 6 Way side mountedMultiport valve with all acessoriesconnection size 63 mm |
| 1217 | Make : AtecPoolSelf Priming Pump ABS plastic impeller of polyperelene flow rate 14.0 m3/hr @10 mtrs head with inbuiltprefilter strainer 1.0 hp ,2850 rpm,230volts (1W+1S) |
| 1218 | Chemical Dosing systems |
| 1219 | Inline chlorine dispenser for chlorine |
| 1220 | Make : AtecPool |
| 1221 | Pool Basin Fittings |
| 1222 | ABS Square drain 300 mm x 300 mm in White plastic |
| 1223 | Make : AtecPool |
| 1224 | Floor inletsin ABS white plastic flow rate 2 m3/hr with 50 mm glue connection |
| 1225 | Make : AtecPool |
| 1226 | Suction Nozzle in ABS white plastic for suction sweeper with 2\" connection |
| 1227 | Make : AtecPool |
| 1228 | ABS white plastic skimmer with inbuilt basket , 2\" connection |
| 1229 | Make : AtecPool-CMP |
| 1230 | Cascade Jet |
| 1231 | Made of Cast BronzeProduce a graceful conical shaped Flow rate 3.0 m3/hr at 8 m head , Orifice : 50 mm , Spray height : 500 mm connection size : 1\" , water level dependent areated display |
| 1232 | Make :PF-3450 |
| 1233 | Chrome Body & spot mirror with polycarbon luminaire cover 8.0 W ( warm white ) 12 to 24 V DC Ø96 mm & depth 90 mm |
| 1234 | Make : Fiberli |
| 1235 | Driver for Underwater light 60 W ,12-24VDC, IP 67 |
| 1236 | Make : Meanwell |
| 1237 | Deck Box ABS for Underwater light |
| 1238 | Make : AtecPool |
| 1239 | Fountain Self Priming Pump ABS plastic impeller of polyperelene flow rate 15.0 m3/hr @8 mtrs head with inbuiltprefilter strainer 1.5 hp ,2850 rpm,230volts (1W+1S) |
| 1240 | Make: AtecPool |
| 1241 | Maintenance Kit |
| 1242 | suction sweeper 450 mm with 1-1/2\" connection size |
| 1243 | Reinforced telescopic Handle 1.2-2.4 mtrs long |
| 1244 | Make : AtecPool |
| 1245 | Deep Bag skimmer clip type |
| 1246 | Make : AtecPool |
| 1247 | Water surface skimmer clip type |
| 1248 | Make : AtecPool |
| 1249 | Curved brush clip type |
| 1250 | Make : AtecPool |
| 1251 | Test kit for pH and chlorine |
| 1252 | Make : AtecPool |
| 1253 | Sub Head 6 :- Plant Room within 20 mtr from water Feature |
| 1254 | uPVC Piping with complete fittings of 10 bar for water feature & Plant Room (3.5 mx 3.5 mx1.8m) min.750 mm lower than drain |
| 1255 | Ø 50 mm drain pipe |
| 1256 | Ø 50 mm Inlet pipe to floor inlet |
| 1257 | Ø 63 mm pump for skimmer |
| 1258 | Ø 50 mm from vacume pipe to pump header |
| 1259 | Ø 32 mm |
| 1260 | Ø 63 mm inlet pipe to fountain |
| 1261 | Ø 75 mm suction pipe to fountain pump |
| 1262 | UPVC paddle flange |
| 1263 | Ø 25 mm |
| 1264 | Ø 50 mm |
| 1265 | Ø 63 mm |
| 1266 | Ø 75 mm |
| 1267 | Ø 90 mm with end plug + pipe 25 mm for U/W Light |
| 1268 | UPVC Ball Valve solvent |
| 1269 | Ball Valve Solvent type Ø 50 mm |
| 1270 | Ball Valve Solvent type Ø 63 mm |
| 1271 | Ball Valve Solvent type Ø 75 mm |
| 1272 | Check valveØ 50 mm solvent type |
| 1273 | Check valveØ 63 mm solvent type |
| 1274 | Common Electrical Panel forrecirculation pumps( 02 nos.) , foutain pumps (02 nos.) `RCCB for underwater lights ,Panel 16 gauge powder coated, VAF, Indicator Lamp , MCB for pumps |
| 1275 | 3 core 2.5 mm2 PVC copper cable for pumps with PVC 20 mm conduit in mtrs |
| 1276 | 2 Core Copper cable with rigid conduit for Underwater light (2.5 mm2) |
| 1277 | Intial chemical charge for 7 days of working ( HCL/TCCA/ALUM/ALEGACIDE) |
| 1278 | Pipe support |
| 1279 | SWG 8 GI wire for pumps/panel |
| 1280 | Sub Work 7 Water Cascade-1 |
| 1281 | Water Cascade - 1Skimmer Type Area : 164 m2 x 0.5 m depthTotal Pool Volume: 82 m3Filteration Flow rate: 28.0 m3/hr |
| 1282 | Filtration Plant with Pump |
| 1283 | Bobbin Wound PolysterFibre Glass , Filtration Velocity : 30 m3/hr/m2 Dia. 750 mm working pressure 2.5 kg/cm2 Flow rate: 14 m3/hr outletconnection 63 mm , complete with pressure gauge,manual bleeder,water drain,empty drain for filter media with 500mm bed depth with media ( 450 kgs) |
| 1284 | Make : AtecPool |
| 1285 | 6 Way side mountedMultiport valve with all acessoriesconnection size 63 mm |
| 1286 | Make : AtecPool |
| 1287 | Self Priming Pump ABS plastic impeller of polyperelene flow rate 14.0 m3/hr @10 mtrs head with inbuiltprefilter strainer 1.0 hp ,2850 rpm,230volts (2W+1S) |
| 1288 | Make: AtecPool |
| 1289 | Chemical Dosing systems |
| 1290 | Dosing pump 0-5 LPH at 5 bar with 100 ltrs tank for pH & chlorine |
| 1291 | Make : AtecPool-Aqua |
| 1292 | Pool Basin Fittings |
| 1293 | ABS Square drain 300 mm x 300 mm in White plastic |
| 1294 | Make : AtecPool |
| 1295 | Floor inletsin ABS white plastic flow rate 2 m3/hr with 50 mm glue connection |
| 1296 | Make : AtecPool |
| 1297 | Suction Nozzle in ABS white plastic for suction sweeper with 2\" connection |
| 1298 | Make : AtecPool |
| 1299 | ABS white plastic skimmer with inbuilt basket , 2\" connection |
| 1300 | Make : AtecPool-CMP |
| 1301 | Water Wall 100 mtrs |
| 1302 | Perporated pipe in UPVC 110 mm with perforation |
| 1303 | Chrome Body & spot mirror with polycarbon luminaire cover 8.0 W ( warm white ) 12 to 24 V DC Ø96 mm & depth 90 mm |
| 1304 | Make : Fiberli |
| 1305 | Driver for Underwater light 60 W ,12-24VDC, IP 67 |
| 1306 | Make : Meanwell |
| 1307 | Deck Box ABS for Underwater light |
| 1308 | Make : AtecPool |
| 1309 | Fountain Self Priming Pump ABS plastic impeller of polyperelene flow rate 60.0 m3/hr @ 10 mtrs head with inbuiltprefilter strainer 5.5 hp ,2850 rpm, 400volts (3W+1S) |
| 1310 | Make: AtecPool |
| 1311 | Sub Work 8Plant Room Within 20 mtrs from Water Features |
| 1312 | Plant Room within 5 mtrs from Water Feature |
| 1313 | uPVC Piping with complete fittings of 10 bar for water feature & Plant Room (5 mx5 mx1.8m) min.750 mm lower than drain |
| 1314 | Ø 50 mm drain pipe |
| 1315 | Ø 75 mm Inlet pipe to floor inlet |
| 1316 | Ø 90 mm pump for skimmer |
| 1317 | Ø 50 mm from vacume pipe to pump header |
| 1318 | Ø 110 mm inlet pipe to water wall |
| 1319 | Ø 160 mm suction pipe for water wall |
| 1320 | UPVC paddle flange |
| 1321 | Ø 25 mm |
| 1322 | Ø 50 mm |
| 1323 | Ø 75 mm |
| 1324 | Ø 90 mm |
| 1325 | Ø 110 mm |
| 1326 | Ø 160 mm |
| 1327 | Ø 90 mm with end plug + pipe 25 mm for U/W Light |
| 1328 | UPVC Ball Valve solvent |
| 1329 | Ball Valve Solvent type Ø 50 mm |
| 1330 | Ball Valve Solvent type Ø 63 mm |
| 1331 | Ball Valve Solvent type Ø 75 mm |
| 1332 | Butterfly valve with Valve kitØ 90 mm |
| 1333 | Butterfly valve with Valve kitØ 110 mm |
| 1334 | Butterfly valve with Valve kitØ 110 mm |
| 1335 | Check valveØ 50 mm solvent type |
| 1336 | Check valveØ 75 mm solvent type |
| 1337 | wafertype Check valveØ 110 mm with valve kit |
| 1338 | Common Electrical Panel forrecirculation pumps( 03 nos.) , foutain pumps (03 nos.) `RCCB for underwater lights ,Panel 16 gauge powder coated, VAF, Indicator Lamp , MCB for pumps, with phase preventer |
| 1339 | 3 core 2.5 mm2 PVC copper cable for pumps with PVC 20 mm conduit in mtrs |
| 1340 | 3 core 4.05 mm2 PVC copper cable for pumps with PVC 20 mm conduit in mtrs |
| 1341 | 2 Core Copper cable with rigid conduit for Underwater light (2.5 mm2) |
| 1342 | Intial chemical charge for 7 days of working ( HCL/TCCA/ALUM/ALEGACIDE) |
| 1343 | Pipe support |
| 1344 | SWG 8 GI wire for pumps/panel |
| 1345 | Sub Work-9 Water Cascade |
| 1346 | Water Cascade - 2Skimmer Type Area : 164 m2 x 0.5 m depthTotal Pool Volume: 82 m3Filteration Flow rate: 28.0 m3/hr |
| 1347 | Filtration Plant with Pump |
| 1348 | Bobbin Wound PolysterFibre Glass , Filtration Velocity : 30 m3/hr/m2 Dia. 750 mm working pressure 2.5 kg/cm2 Flow rate: 14 m3/hr outletconnection 63 mm , complete with pressure gauge,manual bleeder,water drain,empty drain for filter media with 500mm bed depth with media ( 450 kgs) |
| 1349 | Make : AtecPool |
| 1350 | 6 Way side mountedMultiport valve with all acessoriesconnection size 63 mm |
| 1351 | Make : AtecPool |
| 1352 | Self Priming Pump ABS plastic impeller of polyperelene flow rate 14.0 m3/hr @10 mtrs head with inbuiltprefilter strainer 1.0 hp ,2850 rpm,230volts (2W+1S) |
| 1353 | Dosing pump 0-5 LPH at 5 bar with 100 ltrs tank for pH & chlorine |
| 1354 | ABS Square drain 300 mm x 300 mm in White plastic |
| 1355 | Floor inletsin ABS white plastic flow rate 2 m3/hr with 50 mm glue connection |
| 1356 | Suction Nozzle in ABS white plastic for suction sweeper with 2\" connection |
| 1357 | ABS white plastic skimmer with inbuilt basket , 2\" connection |
| 1358 | Perporated pipe in UPVC 110 mm with perforation |
| 1359 | Chrome Body & spot mirror with polycarbon luminaire cover 8.0 W ( warm white ) 12 to 24 V DC Ø96 mm & depth 90 mm |
| 1360 | Driver for Underwater light 60 W ,12-24VDC, IP 67 |
| 1361 | Deck Box ABS for Underwater light |
| 1362 | Fountain Self Priming Pump ABS plastic impeller of polyperelene flow rate 60.0 m3/hr @ 10 mtrs head with inbuiltprefilter strainer 5.5 hp ,2850 rpm, 400volts (3W+1S) |
| 1363 | Sub Work 6:-Plant Room within 5 mtrs from Water Feature |
| 1364 | Plant Room within 5 mtrs from Water Feature |
| 1365 | uPVC Piping with complete fittings of 10 bar for water feature & Plant Room (5 mx5 mx1.8m) min.750 mm lower than drain |
| 1366 | Ø 50 mm drain pipe |
| 1367 | Ø 75 mm Inlet pipe to floor inlet |
| 1368 | Ø 90 mm pump for skimmer |
| 1369 | Ø 50 mm from vacume pipe to pump header |
| 1370 | Ø 110 mm inlet pipe to water wall |
| 1371 | Ø 160 mm suction pipe for water wall |
| 1372 | UPVC paddle flange |
| 1373 | Ø 25 mm |
| 1374 | Ø 50 mm |
| 1375 | Ø 75 mm |
| 1376 | Ø 90 mm |
| 1377 | Ø 110 mm |
| 1378 | Ø 160 mm |
| 1379 | Ø 90 mm with end plug + pipe 25 mm for U/W Light |
| 1380 | UPVC Ball Valve solvent |
| 1381 | Ball Valve Solvent type Ø 50 mm |
| 1382 | Ball Valve Solvent type Ø 63 mm |
| 1383 | Ball Valve Solvent type Ø 75 mm |
| 1384 | Butterfly valve with Valve kitØ 90 mm |
| 1385 | Butterfly valve with Valve kitØ 110 mm |
| 1386 | Butterfly valve with Valve kitØ 110 mm |
| 1387 | Check valveØ 50 mm solvent type |
| 1388 | Check valveØ 75 mm solvent type |
| 1389 | wafertype Check valveØ 110 mm with valve kit |
| 1390 | Common Electrical Panel forrecirculation pumps( 03 nos.) , foutain pumps (03 nos.) `RCCB for underwater lights ,Panel 16 gauge powder coated, VAF, Indicator Lamp , MCB for pumps, with phase preventer |
| 1391 | 3 core 2.5 mm2 PVC copper cable for pumps with PVC 20 mm conduit in mtrs |
| 1392 | 3 core 4.05 mm2 PVC copper cable for pumps with PVC 20 mm conduit in mtrs |
| 1393 | 2 Core Copper cable with rigid conduit for Underwater light (2.5 mm2) |
| 1394 | Intial chemical charge for 7 days of working ( HCL/TCCA/ALUM/ALEGACIDE) |
| 1395 | Pipe support |
| 1396 | SWG 8 GI wire for pumps/panel |
| 1397 | PART - III FIRE FIGHTING PUMPS & EQUIPMENT |
| 1398 | Supply, installation, testing & commissioning of electric driven Hydrant Pump & Sprinkler pumpsuitable for automatic operation consisting of the following: Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pump Squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump. NSCommon bed plate of fabricated mild steel channel or cast iron type.Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required.NSThe pump shall be of the following specifications:Discharge- 2850 lpmHead - 70 mNo. of stage preferred - Single / DoubleSpeed RPM - 2900Material of construction a) Impeller - Bronzeb) Casing- C.I.c) Shaft & Shaft Sleeve- SS-410d) Bearing - Grease Lubicatede) Seal & Make- MechanicalType of pump - End suction |
| 1399 | Supply, installation, testing & commissioning of electric driven water curtain pumpsuitable for automatic operation consisting of the following: Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pumpSquirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump.Common bed plate of fabricated mild steel channel or cast iron type.Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. The pump shall be of the following specifications:Discharge- 2850 lpmHead - 40 mNo. of stage preferred - Single / DoubleSpeed RPM - 2900Material of construction a) Impeller - Bronzeb) Casing- C.I.c) Shaft & Shaft Sleeve- SS-410d) Bearing - Grease Lubicatede) Seal & Make- MechanicalType of pump - End suction |
| 1400 | Supply, installation, testing & commissioning of electric driven Jockey Pump suitable for automatic operation consisting of the following:Horizontally mounted centrifugal end suction pump complete with mechanical seal and including necessary arrangement for testing of pump.Squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump.Common bed plate of fabricated mild steel channel or cast iron type.Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. The pump shall be of the following specifications:Discharge- 300 lpmHead - 70 mNo. of stage preferred - MultistageSpeed RPM - 2900Mover- Electric Motor DrivenMaterial of construction a) Impeller - Bronzeb) Casing- C.I.c) Shaft & Shaft Sleeve- SS-410d) Bearing - Grease Lubicatede) Seal & Make- MechanicalType of pump - End suction |
| 1401 | Supply, installation, testing & commissioning of diesel engine Hydrant Pump suitable for automatic operation consisting of the following:Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pumpWater coolled Diesel Engine developing suitable BHP at 1500-2000 RPM for the Pump,common bed plate for mounting of engine and pump, RCC foundation and vibration damping arrangement by Cushy Foot and engine panel provided by engine manufacturer, connection to Engine Starting Panel as per item (4), sealed maintenance free batteries of 24 V, 88 AH. Rate shall include Exhaust pipe of required length with asbestos lagging, muffler, day oil tank of 400 lts with first charge and manual oil pump set. Flexible coupling and coupling guard with the Pump,Common bed plate of fabricated mild steel channel or cast iron type.Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. Engine panel Sealed maintenance free batteries of 24 V, 88 AHExhaust pipe of required length with asbestos lagging, muffler |
| 1402 | Day oil tank of 400 lts with first charge and manual oil pump set.The pump shall be of the following specifications:Discharge- 2850 lpmHead - 70 mNo. of stage preferred - Single / DoubleSpeed RPM - 1850Mover- Diesel engine drivenMaterial of construction a) Impeller - Bronzeb) Casing- C.I.c) Shaft & Shaft Sleeve- SS-410d) Bearing - Grease Lubicatede) Seal & Make- MechanicalType of pump - End Suction |
| 1403 | Supply, installation, testing & commissioning of diesel engine water curtain Pump suitable for automatic operation consisting of the following:Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pumpWater coolled Diesel Engine developing suitable BHP at 1500-2000 RPM for the Pump,common bed plate for mounting of engine and pump, RCC foundation and vibration damping arrangement by Cushy Foot and engine panel provided by engine manufacturer, connection to Engine Starting Panel as per item (4), sealed maintenance free batteries of 24 V, 88 AH. Rate shall include Exhaust pipe of required length with asbestos lagging, muffler, day oil tank of 400 lts with first charge and manual oil pump set.Flexible coupling and coupling guard with the Pump,Common bed plate of fabricated mild steel channel or cast iron type. |
| 1404 | Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. Engine panel Sealed maintenance free batteries of 24 V, 88 AHExhaust pipe of required length with asbestos lagging, mufflerDay oil tank of 400 lts with first charge and manual oil pump set.The pump shall be of the following specifications:Discharge- 2850 lpmHead - 40 mNo. of stage preferred - Single / DoubleSpeed RPM - 1850Mover- Diesel engine drivenMaterial of construction a) Impeller - Bronzeb) Casing- C.I.c) Shaft & Shaft Sleeve- SS-410d) Bearing - Grease Lubicatede) Seal & Make- MechanicalType of pump - End Suction |
| 1405 | Design,supply,installation,testing andcommissioningofnon draw out Cubical typesectionalised floor standing powder coated switch board of 31 MVA fault capacity at 415 V +/- 10% complete with 4 strip, 600 A capacity Aluminium Bus - Bar Electrolytic grade, cable alley & supplying & fixing of following switchgears including connections & interconnections complete as required for 1 No Hydrant Pump, 1 No sprinker pump, 1 No Water Curtain Pump, 2 Nos. Jockey Pump, 1 No Engine Starting Panel for Diesel Pump & 1 No Engine Starting Panel for Water Curtain Diesel Pump Details of requirements given in specs.CUBICAL FIRE PANEL BOARDi) For 1 x 55 KW Fire hydrant Pump ( or motor rating as per pump design)ii) For 1 x 55 KW Sprinkler Pump (motor rating as per pump design)iii) For 1 x 30 KW Water Curtain Pump (motor rating as per pump design)iv) For 2 x 15 KW Jockey Pumps ( Motor rating as per pump manufacturer design) |
| 1406 | INCOMER1 no. 500A TPN MCCBwith Thermal Magnetic Release & ROH, with 96 mm (0 -500 A) ammeter with 3 CT and selector switch, 96 mm (0 - 300 V) Voltmeter with selector switch, phase indication light withprotectionfuse-01 Set. |
| 1407 | OUTGOINGSi) For 2 x 55 KW Wet Riser, Sprinkler Pump.200 A TP MCCB with DOL starter, overload relay start / stop push buttons, 96 mm (0-200 A) ammeter with three CT & selector switch, on / off / trip indication light with protection fuses, single phase preventer. - 02 Setsii) For 1 x 30 KW water curtain pump.100 A TP MCCB with DOL starter, overload relay start / stop push buttons, 96 mm (0-100 A) ammeter with three CT & selector switch, on / off / trip indication light with protection fuses, single phase preventer. - 01 Setii) For 2 x 15 KW Jockey Pump63A TP MCB, 25 A DOL starter, overload relay, start/stop push buttons, ammeter (0-40A) with three CT & selector switch, on/off/trip indication lights with protection fuse, single phase preventer. - 02 Setsiii) 32 A MCB for battery charging alongwith engines start relay 24V DC with AMF Panel- 02 setsiv) Provision for starting the diesel engine fire pump with battery charger for trickle & boost charging. The diesel engine driven fire pump shall start automatically in the event of pressure drop beyong preset limit on mains faulure or failure of electrical driven pumps to start. |
| 1408 | Note:- CABEL CONNECTIONSeparate neutral link to be provided wherever TP MCCB are used.Following provisions to be made in the fire panel:Audio visual alarm & indications having disconnect / reset facility with a range of 1/2 km. Annunciator to be provided in the Fire panel with hooter and acknowledge, test and reset P Bs. The indication shall come on when electrical driven pump set fails to start on pressure drop or when there is power failure during pressure drop.Facility for mode selection ie auto or manual test & local/remote.Protection failure & control cabling.Panel shall be interlocked in such a way when fire pump startson pressure drop in the header, supply to working chiller A/c panel is disconnected.Remote indication of ON/OFF/TRIP shall be provided through potential free contact.Provision of remote starting/stopping (manuals) of the engine shall be made. |
| 1409 | NOTE:All pumps operation shallbe controled by flow switches.The logic of control panel based on specification attached.All pumps shall be works automatically or manually. |
| 1410 | (panel starter shall be based onpumps motor rating if any changes in motor rating the starter rating shall change and fabrication shall start only after approval of drawing) |
| 1411 | Supplying & fixing air vessel made out of 450mm,Dia, 8 mm thick MS sheet ,2000mm hight with air release valves on top and flanged connection to risers, drain arrangements with 50mm dia gunmental wheel valves,with required accessories,pressure gaguge and painting with synthetic enamel paint of approved shade as required. |
| 1412 | Providing and laying the PVC insulated & sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor including supplying and making end termination with brass compression glandsitem No. |
| 1413 | 3 core x 70 sq.mm |
| 1414 | 3 core x 25 sq.mm |
| 1415 | 4 core x 2.5 sq mm |
| 1416 | Providing and fixing pressure switches of approved make in MS pipe line suitable for line pressure up 15kg/cm2 & including connection with main panel etc. as required complete in all respect. |
| 1417 | Providing and fixing fire retardent / extinguishing electrical insulated synthetic mat of 3mm thick ±10% conforming to latest BIS doc no.-ET-02(5440) meeting requirements of IS 3043 / IS 5216 (Part I, II & III), IS 8437 & IEC 479 suitable for all voltages not exceeding 3.3 KV AC supply and having minimum width of 1000mm ± 20mm and including supply of required quantity of adhsive / compound and fixing the same at site as per site requirement. |
| 1418 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 1419 | Cable Tray Size 150mm x 50mm x 50mm (2mm thick) |
| 1420 | Earthing with GI Earth plate 600 mm x 600 mm x 6 mm th. including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) complete as required. ELECT. |
| 1421 | Providing & fixing 25 mm x 5 mm G.I. Strip in on surface or in recess for connections etc as required. ELECT. |
| 1422 | Providing & fixing 25 mm x 5 mm G.I. Strip in 40 mm dia GI pipe from earth electrode as required. ELECT. |
| 1423 | Providing and fixing ofS.S Pressure Gauge comlete as required complete in all respect. Dial diameter 100mm callbration 0-16 KG |
| 1424 | Sub Work -8 Suction and Delivery pipes and Valves for Fire fighting pumps |
| 1425 | Providing, laying, fixing, testing and commissioning of \"C\" Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 1426 | 50mm internal diameter |
| 1427 | 80mm internal diameter |
| 1428 | 100mm internal diameter |
| 1429 | 150mm internal diameter |
| 1430 | 200mm internal diameter |
| 1431 | Supplying, Laying, Testing and Commissioning ofISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked completewith rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 1432 | 80 mm i/d |
| 1433 | 100 mm i/d |
| 1434 | 150 mm i/d |
| 1435 | Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines includingjointing & cost of Nut Bolt , rubber insertion etc.complete. |
| 1436 | 80mm i/d check valve . |
| 1437 | 150mm i/d check valve |
| 1438 | 200mm i/d check valve |
| 1439 | Supplying, Installation, Testing and Commissioning ofcast iron flanged Y type strainer with stainless steelmesh in PN-1.0 including cost of Nut Bolt , rubber insertion complete in all respects. |
| 1440 | 200mm i/d |
| 1441 | Sub Work 9 Fire Hydrant System |
| 1442 | FIRE HYDRANT SYSTEM |
| 1443 | Providing, laying, fixing, testing and commissioning of \"C\" Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. |
| 1444 | 100 mm internal diameter |
| 1445 | 150 mm internal diameter |
| 1446 | Providing, laying, fixing, testing and commissioning of \"C\" Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surfaceandproviding angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 1447 | 100mm internal diameter |
| 1448 | 150mm internal diameter |
| 1449 | Providing, laying, fixing, testing and commissioning of \"C\" Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 1450 | 80mm internal diameter |
| 1451 | Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects. |
| 1452 | Supplying, Installation, Testing and Commissioning63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzleconfirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required. |
| 1453 | Providing and fixingfire brigade inlet connection of cast iron body with Gun metal63mm dia instantaneous type male coupling withbuilt in check valves and 150mm dia flanged outlet complete with bolts,nuts and rubber insertionsas per IS:904. (tobe connected to static tank). |
| 1454 | Four Way inlet connection |
| 1455 | Two Way inlet connection |
| 1456 | Supplying, Installation, Testing and Commissioning ofRRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required. |
| 1457 | Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type-2, hose reel Drum with bracket as per IS:884,20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect. |
| 1458 | Supplying, Installation, Testing and Commissioningstandard Fire Man\"s axe with heavy insulated rubber conforming to IS 936 complete in all respect. |
| 1459 | Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc. |
| 1460 | 900 mm wide x 600 mm high x 500 mm deep Size (for Yard Hydrant) |
| 1461 | 1200 mm wide x 900 mm high x 400 mm deep Size |
| 1462 | Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required |
| 1463 | Providing and fixing S.S Pressure Gaugecomplete as required complete in all respect. |
| 1464 | Dial diameter 100mm calibration 0-16 Kg |
| 1465 | Supplying, Laying, Testing and Commissioning ofISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked completewith rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 1466 | 80 mm i/d |
| 1467 | 100 mm i/d |
| 1468 | 150 mm i/d |
| 1469 | Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines includingjointing & cost of Nut Bolt , rubber insertion etc.Complete |
| 1470 | 100 mm i/d check valve |
| 1471 | 150 mm i/d check valve |
| 1472 | Providing ,laying, jointing, fixing and testing ISI MarkedG.I. Pipe (as per IS 1239) B-Class including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete |
| 1473 | 40mm i/d |
| 1474 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 1475 | 40mm i/d Brass Ball Valves |
| 1476 | Providing and fixing 6 mm thick stainless steel Orifice flange 80 mm dia x 50 mm minimum bore as per requirements to restric the pressure to 3.5 kg per sq cm at the point of branching off from Riser on lower floors. |
| 1477 | Providing and fixing suction coupling for fire brigade drawl of water from tank with 100 mm dia GI (Medium) pipe and foot valve (Pipe max 8 M long) |
| 1478 | Sub Head-10 Sprinker System |
| 1479 | Providing, laying, fixing, testing and commissioning of \"C\" Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. |
| 1480 | 100mm internal diameter |
| 1481 | 150mm internal diameter |
| 1482 | Providing, laying, fixing, testing and commissioning of \"C\" Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 1483 | 25mm internal diameter |
| 1484 | 32mm internal diameter |
| 1485 | 40mm internal diameter |
| 1486 | 50mm internal diameter |
| 1487 | 65mm internal diameter |
| 1488 | 80mm internal diameter |
| 1489 | 100mm internal diameter |
| 1490 | 150mm internal diameter |
| 1491 | Supplying and Installation control valveC/W water motor gong complete with alarm Valve, constant trim, water motor bell, 2No. Pressure Gauge. All parts UL listed. Make Newagecomplete in all respect. |
| 1492 | 150mm control valve |
| 1493 | Providing and fixing S.S Pressure Gaugecomplete as required complete in all respect. |
| 1494 | Dial diameter 100mm calibration 0-16 Kg |
| 1495 | Supplying an Fixing Pendant / Upright type sprinkler with quartzoid bulb, operating temperature 68 / 79 degree centigrade of 15 mm dia orifice sprinler head to approved by UL/SN |
| 1496 | Supplying an Fixing Pendant / Upright type sprinkler with quartzoid bulb, operating temperature 68 / 79 degree centigrade of 15 mm dia orifice sprinler head to approved by UL/SN |
| 1497 | Supplying and Fixing Sidewall Sprinkler rated at 68 / 79degree centigrade, quartzoid bulb type, 15 mm dia orificesprinler head to approved by UL/SN complete in all respect. |
| 1498 | Providing and fixing Vane type Water flow switch in MS Pipe line for a service pressure up to 450PSI , Minimum flow rate for alarm 10GPM (38 LPM ), Minimum surge 18 FPS (5.5 m/s ) including connection with panel complete in all respect |
| 1499 | For 50mm to 150mm pipe line |
| 1500 | For 200mm pipe line |
| 1501 | Supplying, Laying, Testing and Commissioning ofISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked completewith rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 1502 | 80 mm i/d |
| 1503 | 100 mm i/d |
| 1504 | 150 mm i/d |
| 1505 | Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines includingjointing & cost of Nut Bolt , rubber insertion etc.complete. |
| 1506 | 100 mm i/d check valve |
| 1507 | 150 mm i/d check valve |
| 1508 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 1509 | 50mm i/d Brass Ball Valves |
| 1510 | Providing, fixing, testing and commissioning of main control fire alarm panel suitable for 16 zones sprinkler system complete with indivisual indication for each zone with LED, Piezo Sounder and Acknowledge facility. |
| 1511 | Providing and laying 2 x 2.5 sq mm copper conductor PVC sheathed armoured cable for connecting fire alarm Panel to flow switch. |
| 1512 | Sub Work-11 Water Curtain System |
| 1513 | Supplying, Laying, Testing and Commissioning ofISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked completewith rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 1514 | 100 mm i/d |
| 1515 | Providing, laying, fixing, testing and commissioning of \"C\" Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surfaceandproviding angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 1516 | 100 mm internal diameter |
| 1517 | 150 mm internal diameter |
| 1518 | Providing, laying, fixing, testing and commissioning of \"C\" Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 1519 | 50mm internal diameter |
| 1520 | 65mm internal diameter |
| 1521 | 80mm internal diameter |
| 1522 | Providing and fixing S.S Pressure Gaugecomplete as required complete in all respect. |
| 1523 | Dial diameter 100mm calibration 0-16 Kg |
| 1524 | Providing, fixing, testing & commissioning of brass water Curtain Nozzles TAC/LPC approved K-30 having 15mm BSP threads. |
| 1525 | Motorized butterfly valves complete with actuator for water control application (ON/OFF) valves complete with suitable matching flanges, nuts, bolts & washers. Motor, cable connectores etc. |
| 1526 | 100 mm Dia |
| 1527 | HAND APPLIANCES |
| 1528 | Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure)as per IS: 15683complete with all accessories as per Manufactures Specification. ISI Markcomplete in all respect. |
| 1529 | 6 Kg.Capacity |
| 1530 | Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Markcomplete in all respect. |
| 1531 | 4.5 Kg. Capacity |
| 1532 | Providing and fixing of FIRE EXTINGUISHER, Mechanical Foam Type 9 ltrIS: 15683 Stored Pressure type complete with all accessories as per Manufactures Specification. ISI Mark of approved makecomplete in all respect. |
| 1533 | Providing and fixing Mechanicalfoam type (ISI marked) fire extinguishers consisting of weldedM.S. cylindricalbody squeeze lever dischargevalve 30 cm longhigh pressure dischargehose, discharge nozzle suspension bracketISI markedas per IS 933 finished externallywithredenamel paint and fixed to wall withbrackets complete with internal charger. (In Pump Room) |
| 1534 | 50 litres capacity (trolly mounted) |
| 1535 | Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked asper IS:2878 finished externallywith red enamel paint and fixed to wall with brackets complete with internal charge. (In Pump Room) |
| 1536 | Capacity 22.5 kg. IS 2878 |
| 1537 | Sub Work-12 Basement Ventilation Panel Zone-1 |
| 1538 | Axial Flow Fan |
| 1539 | Supply, installation, testing and commissioning of axial flow tube/vane type fresh/exhaust fan complete fan made out of M.S. / G.I. casing having cast aluminium alloy impeller with high efficiency Aero-foil section blade directly driven,with fan with motor, drive set, mounting frame, mounting accessories canvass connection, spring isolator, gravity damper of G.I. at fan outlet.All the fans are synthetic enamelled painted and complete with birdscreen at inlet as well as outlet. The electric motor coupler shall be squirrel cage induction motor confirming to IS - 325-IP-55 with class \"H\" insulation, motor shall be fire rated upto 250 degrees centigrade for 21/2 hour rating. Fan should be as per specification and drawings.Motor shall be suitable for 415V/50Hz/3 Phase power supply.( Fan to be suspended from ceiling/installed on wall required M.S. supports etc. and mounting accessories should be taken ). |
| 1540 | 36,000 cfm, 40 mmwg static pressure |
| 1541 | 34,500 cfm 40 mmwg static pressure |
| 1542 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.. |
| 1543 | G.I. Sheet Metal Ducting (Rectangular) |
| 1544 | 0.63 mm (24 Ga) |
| 1545 | 0.80 mm (22 Ga) |
| 1546 | 1.00 mm (20 Ga) |
| 1547 | 1.25 mm (18 Ga) |
| 1548 | Grilles/Diffusers Supply, installation, testing and commissioning of Aluminium extruted powder coated supplyand returnairgrilles/ diffusers as per specifications and drawings (Approval of colour shall be taken from Architects/Consultants). |
| 1549 | Supplying & fixing of powder coated extruded aluminium Supply / Exhaust Air Grills with aluminium volume control dampers as per specifications. |
| 1550 | Fresh air GrillesSupply and installation of Fresh air grille of 18 Ga G.I. withlouvers, bird Screen and damper as per specifications and drawings. |
| 1551 | Volume Control DamperSupply, installation, testing & commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. |
| 1552 | Electric Panel BoardBasement Ventilation PanelSupply, installation,testing & commissioning of sub panel board cubical compartmentalised, floor mounted made of2.0mmthick steel sheet duly painted complete withvoltmeter, ammeter, indicatinglights for selectorswitch,incoming/outgoingfeedersCTS contactorsfor complete asperspecifications andrequired.1 No. 630 Amps TPN incoming MCCB.1 Set 800 Amps TPN Aluminium conductor bus bar duly sleeved. |
| 1553 | 13 Nos. 63 Amps MCCB outgoing along with 13 Nos. star delta starter for axial fan 15.0 kw motor. (1 No. Spare) |
| 1554 | XLPE INSULATED ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 1555 | Overall size 400sq.mm (3½ Core) Armoured (Loose) |
| 1556 | Overall size 4sq.mm (3Core) Armoured (Loose) |
| 1557 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 1558 | Cable Tray Size 450mm x 50mm x 50mm (2mm thick) |
| 1559 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 1560 | EarthingSupply and laying of double earthing continuity conductors of G.I. /G.S.S between panel boards and equipments as drawings. (May be checked at site). |
| 1561 | Providing & fixing of 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1562 | Providing & fixing of 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 1563 | Sub Work-2 Sangat Hall Zone-2 |
| 1564 | Sangat Hall VentilationZone-2Propeller FanSupply, installation, testing and commissioning of propeller fans for exhaust air as shown on drawings. Each fan shall be complete with permanenet split capacitor, mounting plate and accessories like wire guard, bird screen for weather protection as required, complete MCB panel and cabling, earthing as per specifications and drawings.630 mm dia, 5000 cfm |
| 1565 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 1566 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 1567 | Sub Work-2 A. MUSEUM,INTERPRETATION CENTRE & LEVEL + 85.05M Zone-3 Water Chilling Unit |
| 1568 | A. MUSEUM,INTERPRETATION CENTRE & LEVEL + 85.05M Zone-3 Water Chilling UnitSupply Installation,testing and commissioning of Aircooled screw chilling unit complete with semi hermetic/hermetically sealed screw compressor single/multi circuit chiller, aircooled condenser, microprocessor based control panel,chiller shall have star delta starter, refrigerant controls & piping, mounting base frame, foundations, foundation shall be vibration with anti vibration pads etc. complete as per specifications and drawings.Chilled water out : 7.2O CChilled water in : 12.8O CChiller F.F. :As Per AHRIDesign Outside Air Ambient 43.3 Degree CelciusIKW shall be 1.41 (on tender condition)110 TR ( Actual ) |
| 1569 | Pump SetSupplying, installing, testing and commissioning of following Vertical Inline type chilled water PUMPS sets with bronze impeller fully enclosed type impeller shall be dynamically balanced, pump casing shall be cast iron suitable for 175 psig (12 bars) working pressure at 1400 F (600C). The casing shall be hydrostatically tested to 150% maximum working pressure. Mechanical seal shall be single spiring inside type with resin bonded carbon with stainless steel spring and hardware. TEFC squirrel cage, induction motor, base plate, pressure gauges at inlet and outlet, priming function.(Pumps shall be fitted with SS expansion joints on suction / discharge side, factory mounted on a common base with electric motor for recirculation of water for the central air conditioning system. Weather proof canopy shall be required. All pumps shall be aligned properly as required. The pump motor shall be suitable for 415 + 10% volts, 50 cycles, 3 phase power supply meeting criterion of ASHRAE standard 90.1 – 2007 and high efficiency.Pumps with performance characteristics as given below .Primary Chilled water pump, 264 USGPM at 12 mt. head |
| 1570 | SecondaryChilled WaterPumpswith Variable Speed Pumping System Supplying, installing, testing and commissioning of following Vertical Inline type chilled water PUMPS sets with bronze impeller fully enclosed type impeller shall be dynamically balanced, pump casing shall be cast iron suitable for 175 psig (12 bars) working pressure at 1400 F (600C). The casing shall be hydrostatically tested to 150% maximum working pressure. Mechanical seal shall be single spiring inside type with resin bonded carbon with stainless steel spring and hardware. TEFC squirrel cage, induction motor, base plate, pressure gauges at inlet and outlet, priming function.(Pumps shall be fitted with SS expansion joints on suction / discharge side, factory mounted on a common base with electric motor for recirculation of water for the central air conditioning system. Weather proof canopy shall be required. All pumps shall be aligned properly as required. The pump motor shall be suitable for 415 + 10% volts, 50 cycles, 3 phase power supply meeting criterion of ASHRAE standard 90.1 – 2007 and high efficiency.Pumps with performance characteristics as given below . |
| 1571 | Variable speed pumping system consisting of 1 No. (EFF-1 motor) pumps, 1 No. dedicated microprocessor based pump controller with parallel pumping software duly downloaded, 1 No. adjustable frequency drives and multiple differential pressure sensor/ transmitters as necessary and as described in the specifications. |
| 1572 | The entire system alongwith pumps must be sourced from single manufacturer only .The system shall be complete in all respects and suitable for following rating.Vertical inline secondary chilled water pump 264 USGPM at 25 mtr. Head. |
| 1573 | Variable Refrigerant Volume SystemSupply, installation, testing and commissioning of variable refrigerant volume modular typeairconditioning system complete with indoorand out door units with individual controller and with refrigerant piping, gas charging R-410, M.S. stand, control cabling asper detailgiven in specifications and having following items: |
| 1574 | Outdoor Unit14 HP(11.2 TR) |
| 1575 | Indoor UnitsVRV ductable unit 2047 cfm (6.36 Tons) . |
| 1576 | VRV ductable unit 1130 cfm (3.18 Tons) . |
| 1577 | VRV furredin unit 583 cfm (2.02 Tons) . |
| 1578 | Imported fittings Y-jointsand headers etc. |
| 1579 | Corded remote controls |
| 1580 | Airhandling Units(Floor Mounted Type)Supply, installation, testing and commissioning offactory builtfloor mounted chilled/hot water double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.8 mm precoated outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation of density not less than 38 kg/cum, factory injected between them by injection molding machine, complete with DIDW forward curved centrifugal fan section suitable for static pressure as detailed below, fire retardent flexible connection, cooling/heating coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm) cooling/heating coil, filter sections with 50 mm thick metal washable synthetic type air pre-filters,belt drive package with TEFC high efficiency motor type EFF-2 suitable for 415+-10% volts.50 HZ, 3 Phase, A.C. supply, drain connections, stainless steel drain pan complete with all fittings and accessories, necessary vibration isolation arrangement etc.complete as per specifications and of following capacities. |
| 1581 | AHU FM 17,000 CFM,6 Row Cooling/Heating Coil, 57 TR, 50 mmwg Static Pressure,Forward Curved Blower,Pre Filter. |
| 1582 | Airhandling Units(Ceiling Suspended Type) |
| 1583 | Supply, installation, testing and commissioning offactory built ceiling suspended type chilled/hot water double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.8 mm precoated outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation of density not less than 38 kg/cum, factory injected between them by injection molding machine, complete with DIDW forward curved centrifugal fan section suitable for static pressure as detailed below,fire retardent flexible connection,cooling/heating coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm) cooling/heating coil,filter sections with 50 mm thick metal washable synthetic type air pre-filters,belt drive package with TEFC high efficiency motor type EFF-2 suitable for 415+-10% volts.50 HZ, 3 Phase, A.C. supply,drain connections, stainless steel drain pan complete with all fittings and accessories, necessary vibration isolation arrangement etc.complete as per specifications and of following capacities. |
| 1584 | AHU CS 4,500 CFM,6 Row Cooling/Heating Coil, 15 TR, 40 mmwg Static Pressure,Forward Curved Blower,Pre Filter.(For Level +99.4M) |
| 1585 | AHU CS 3,000 CFM,6 Row Cooling/Heating Coil, 10 TR, 40 mmwg Static Pressure,Forward Curved Blower,Pre Filter.(For Level +94.6M) |
| 1586 | AHU CS 2,000 CFM,6 Row Cooling/Heating Coil, 7 TR, 32 mmwg Static Pressure,Forward Curved Blower,Pre Filter.(For Level +94.6M) |
| 1587 | PID ValvesSupply, installation, testing and commissioning of 2 way modulating valve cum pressure independent balancing valve along with actuator & proportionate thermostat, transformer complete as per specifications and drawings. |
| 1588 | 100 mm dia |
| 1589 | 50 mm dia |
| 1590 | 40 mm dia |
| 1591 | Insulated Chilled/HotWater Piping (Nitrile Rubber Insulation)Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled/hot water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastomeric nitrile rubber of class \"O\" insualtion applied by adhesive cofirming to standard specifications and finally applying 0.63 mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS : 1322 as amended upto date) at joints and repairing of damage to building etc. as per specifications and as required complete in all respect.Note : The pipes size 150 mm and below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS : 3589 from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm dia and for minimum 7 mm thick M.S. sheet for pipes for 400 mm dia and above. |
| 1592 | Piping |
| 1593 | 100 mm (32 mm thick insulation) |
| 1594 | 80 mm (32 mm thick insulation) |
| 1595 | 65 mm (32 mm thick insulation) |
| 1596 | 50 mm (32 mm thick insulation) |
| 1597 | 40 mm (32 mm thick insulation) |
| 1598 | Insulated ValvesSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled/hot water plumbing duly insulated tothe same specifications as the connected piping andadequately supported as per specifications. |
| 1599 | Supply, installation, testing and commissioning of Motorized Butterfly Valves along with Controls Actuators, Control Wiring,Transformer etc. |
| 1600 | 125 mm dia |
| 1601 | Butterfly Valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled/hot wate circulation as specified. |
| 1602 | 125 mm |
| 1603 | 100 mm |
| 1604 | 50 mm |
| 1605 | Balancing Valve with Built in Measuring Facility with C I body flanged construction with EPDM coated disc with longpitch with protected out pipe insulation & PN 16 pressure rating for chilled/hot water circulation as specified. |
| 1606 | 125 mm |
| 1607 | 100 mm |
| 1608 | Non Return ValvesNon return valve with dual plate of CI body and SS plates vulcanized NBR seal flanged and PN 16 pressure rating for chilled/hotwater circulation including insulation as specified. |
| 1609 | 125 mm |
| 1610 | Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation includinginsulation as specified. |
| 1611 | 125 mm |
| 1612 | 100 mm |
| 1613 | 50 mm |
| 1614 | Pot Strainer |
| 1615 | 125 mm |
| 1616 | Ball Valves |
| 1617 | 40 mm with strainer |
| 1618 | 40 mm without strainer |
| 1619 | Flexible Connection |
| 1620 | 125 mm |
| 1621 | Water flow switch |
| 1622 | Providing and fixing of in position the industrial type pressure gauges with gun metal / brass valves complete as required. |
| 1623 | Providing and fixing of in position the mercury in glass industrialtype thermometers. |
| 1624 | Auto Airvent 25 mm dia |
| 1625 | Burried Chilled/Hot Water PipingSuppluing, laying / fixing, testing and commissioning of following nominal sizes of chilled/hot water piping outside the builiding (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with PUF insualtion 36+2 kg /cum density, pipe section insulation covered with two layer of 120 gm/sqm polythene sheet (vapour barrier), chicken wire mesh and finished with tow coat PARACOAT- BPC of density 1.12 to 1.2 / kg.Note : The pipes size 150 mm and below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS : 3589 from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm dia and for minimum 7 mm thick M.S. sheet for pipes for 400 mm dia and above. |
| 1626 | 125 mm |
| 1627 | 100 mm |
| 1628 | Exposed Chilled / Hot Water Piping |
| 1629 | Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled / hot water piping outside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainer, gauges etc.) duly insulated with PUF insulation 36+2 kg/cum density, pipe section insulation covered with two layer of 120 gm/sqm polythene sheet (vapour barrier) chicken wire mesh and finished with 26 ga aluminium cladding.Note : The pipes size 150 mm and below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS : 3589 from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm dia and for minimum 7 mm thick M.S. sheet for pipes for 400 mm dia and above. |
| 1630 | 125 mm |
| 1631 | Refrigerant Piping |
| 1632 | Supply and installaiton of Interconnecting copper, refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor & outdoor units as perspecifications, all piping inside the buildingshallbe properlysupportedwith MS hanger and shall run in cable trayand all external piping shall run in covered cable tray. |
| 1633 | 28.6 mm O.D.(insulation : 19 mm) (1.00 mm thickness) |
| 1634 | 22.2 mm O.D.(insulation : 13 mm) (1.00 mm thickness) |
| 1635 | 19.1 mm O.D.(insulation : 13 mm) (1.00 mm thickness) |
| 1636 | 15.9 mm O.D.(insulation : 13 mm) (1.00 mm thickness) |
| 1637 | 12.7 mm O.D.(insulation : 13 mm) (0.80 mm thickness) |
| 1638 | 9.5 mm O.D.(insulation : 13 mm) (0.80 mm thickness) |
| 1639 | Air & Dirt Separator |
| 1640 | Supply, installation, testing and commissioning of Air & dirt separator mild steel construction, unit shall be able to remove free air and micro bubbles as well as remove solid particles upto 10 microns. Unit shall be as per specifications & drawings. |
| 1641 | 125 mm dia (Working pressure 3.5 bar) |
| 1642 | Hot Water Generator |
| 1643 | Supply, installation,testing and commissioning of electrical HW generator with sufficient number of electrical imersion heaters. The pressure vessel shall be constructed as per ASME standards and insulated on all sides with 100 mm thick fiber glass and cladded with 0.80 mm aluminium sheet in a neat and clean manner. The generator shall be equipped with all automatic and safety controls such as manual reset high temperature water outlet,step controller and recycling relay,\"ON\" \"OFF\" switch thermostats,pilot light,low water cutoff and other controls as per manufacturers recommendations. All basic controls and terminals shall be located in an integral control cabinet factory wired and tested. The generator shall be suitable for 415(+) (-) 10% volts,50 cycle,3 phase power supply. The entire generator shall be factory assembled and tested at 350 PSI pressure.Brand/model shall be approved by the engineer.Hot waterWater IN45.0O CWater OUT50.5O CWater flow rate504 lit/m180 kw |
| 1644 | Expansion Tank |
| 1645 | Supply,installation,testing and commissioning of PVC expansion tank 200 Liters complete with 50 mm thick expanded polystyrene (TF quality) insulation covered with vapour barrier, 0.5 mm x 20 mm GI wire mesh netting and finished with 0.5 mm thick GI cladding duly plastered and complete with vent and drain connections with float valve, quick fill and control valves etc.as required.Brand/model shall be approved by the engineer incharge. |
| 1646 | 200 litres capacity |
| 1647 | Inline Fans |
| 1648 | Supply, installation, testing and commissioning of inline ducted fans of G.I. construction complete with centrifugal fan with motor, drive, canvassconnection at inlet & outlet complete with MCB panel with cabling and earthing(with 5 Rm). Fan shall be suitable for operation on 220+6% volts, 50 Hz, 1 Phase AC power supply. All single phase inline fans shall be provided with factory filled speed regulation and as per specification and drawings. |
| 1649 | 3,800 cfm, 15 mmwg S.P. |
| 1650 | 2,800 cfm,15 mmwg S.P. |
| 1651 | 1,200 cfm,10 mmwg S.P. |
| 1652 | 1,000 cfm,10 mmwg S.P. |
| 1653 | 800 cfm,10 mmwg S.P. |
| 1654 | 350 cfm,10 mmwg S.P. |
| 1655 | 250 cfm,10 mmwg S.P. |
| 1656 | 100 cfm,10 mmwg S.P. |
| 1657 | Axial Flow Fan |
| 1658 | Supply, installation, testing and commissioning of axial flow tube/vane type fresh/exhaust fan complete fan made out of M.S. / G.I. casing having cast aluminium alloy impeller with high efficiency Aero-foil section blade directly driven,with fan with motor, drive set, mounting frame, mounting accessories canvass connection, gravity damper of G.I. at fan outlet.All the fans are synthetic enamelled painted and complete with birdscreen at inlet as well as outlet. The electric motor coupler shall be squirrel cage induction motor confirming to IS - 325-IP-55 with class \"H\" insulation, motor shall be fire rated upto 250 degrees centigrade for 21/2 hour rating. Fan should be as per specification and drawings.Motor shall be suitable for 415V/50Hz/3 Phase power supply.( Fan to be suspended from ceiling/installed on wall required M.S. supports etc. and mounting accessories should be taken ). |
| 1659 | 11,000 cfm, 40 mmwg static pressure |
| 1660 | 10,500 cfm, 40 mmwg static pressure |
| 1661 | 5,500 cfm, 40 mmwg static pressure |
| 1662 | Packaged Type Airwasher |
| 1663 | Providing, fixing, testing and commissioning packaged type airwasher in double skin construction comprising of DIDW backward curved centrifugal blower, TEFC energy efficient motor, belt, drive packaged, 50 mmthick 7 layer aluminium wire meshfilters, stainless steel 18 Gwetsection, 16 G SS bottom panel of blower section, locable volume control damper of G.I. at fan outlet, 200 mm cellulose paper pads of 90% efficiency, with 100 mm wide PVC eleminator, M.S. reinforced, piping, FRP distributor, double layer canvas connections 1 No. monobloc pump set along with fittings for capacities Mentioned below, M.S. frame for supports as per specification & drawings. |
| 1664 | 13,500 CFMat 40 mmwg static pressure |
| 1665 | Exhaust Scrubber |
| 1666 | Providing, fixing, testing and commissioning of weather proof double skin DIDW centrifugal exhaust scrubber with fan with motor and drive (both fan and motor shall be mounted on a common frame using cushy foot mounting) with back suction and frontdischarge including vibration isolator, water tank with float valve, pump, distributor, nozzels, eleminator, piping & valve from tank to pump to distributor and M.S. frame for supports etc. as per specifications and drawings. |
| 1667 | 15,000 cfm, 40 mm static pressure |
| 1668 | Supply and Installation ofPVC piping complete withfittings, supports as per specifications and dulyinsulated with6 mmthick closed cell nitrile rubber insulation. |
| 1669 | 50 mm dia |
| 1670 | 40 mm dia |
| 1671 | 32 mm dia |
| 1672 | 25 mm dia |
| 1673 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 1674 | G.I. Sheet Metal Ducting (Rectangular) |
| 1675 | 0.63 mm (24 Ga) |
| 1676 | 0.80 mm (22 Ga) |
| 1677 | 1.00 mm (20 Ga) |
| 1678 | 1.25 mm (18 Ga) |
| 1679 | Supplying and fixing of following thickness duly laminated aluminum foilof mat finish closed cell Nitrile rubber (class \"O\") insulation on existing duct after applying two coats of coldsetting adhesive (CPRXcompound). The joints shall sealed with50 mm wide and 3 mm thick self adhesive nitrile rubber tapeinsulation complete as per specifications and as required.19 mm thick |
| 1680 | Duct Acoustic Lining |
| 1681 | Supply & installation ofduct acoustic lining with open cell nitrile rubber insulation of below mention thickness as per specifications and drawings.15 mm |
| 1682 | Grilles/Diffusers |
| 1683 | Supply, installation, testing and commissioning of Aluminium extruted powder coated supplyand returnairgrilles/ diffusers as per specifications and drawings (Approval of colour shall be taken from Architects/Consultants). |
| 1684 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. |
| 1685 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers butwithout volume control dampers complete as required. |
| 1686 | Supplying, fixing testing commissioning of supply / return air diffusersof powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. |
| 1687 | Supplying, fixing testing commissioning of Returnair diffusers of powder coated aluminium without volume control damperswith anti smudge ring & removable core. |
| 1688 | Fresh air Grilles |
| 1689 | Supply and installation of Fresh air grille of 18 Ga G.I. withlouvers, bird Screen and damper as per specifications and drawings. |
| 1690 | Acoustic Insulation for AHU Room |
| 1691 | Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25 X 50 X50 X 50 X 25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc.complete as required and as per specifications. |
| 1692 | Volume Control Damper |
| 1693 | Supply, installation,testing & commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. |
| 1694 | Flexible Duct Connection |
| 1695 | Supply and installaiton ofFire retardant non porous doublelayerflexible connectionbetweeneach indoor unit and duct. |
| 1696 | Fire Damper |
| 1697 | Supplying, fixing, testing and commissioning of fire dampers insupply air duct/main branch and return air path as and wherere quired of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signalcomplete as required and as per specifications. |
| 1698 | Fire dampers |
| 1699 | Actuator assembly (10 NM) |
| 1700 | Electric Panel Board |
| 1701 | Supply, installation,testing & commissioning of sub panel board cubical compartmentalised, floor mounted made of 2.0 mm thick steel sheet duly painted complete with voltmeter, ammeter, indicating lights for selector switch, incoming/outgoing feeders CTS contactors for complete as per specifications and required.1 No. 630 Amps TPN incoming MCCB.1 set 800 Amps TPN Aluminium conductor bus bar duly sleeved.2 Nos. 630 Amps MCCB outgoing for chilling unit. (One Standby)2 Nos. 16 Amps MCB outgoing along with 2 Nos. DOL starter for primary chilled water pump (3.7 kw) (One Standby).2 Nos. 63 Amps MCCB outgoing for secondary pumpand space for VFD (11.0 kw) (One Standby).2 Nos. 630 Amps TPN MCCB outgoing for Hot water generator of 180 kw along with mechanical interlocking with chiller i.e. either chiller or Hot water generator will run. (One Standby) |
| 1702 | Supply, installation, testing & commissioning of sub panel board cubical compartmentalised, floor mounted made of2.0mmthick steel sheet duly painted complete withvoltmeter, ammeter, indicatinglights for selectorswitch,incoming/outgoingfeedersCTS contactorsfor complete asperspecifications andrequired. |
| 1703 | 3 Nos. 63 Amps MCCB outgoing along with 3 Nos. star deltastarter for AHU 11.0 kw motor. (One Spare) |
| 1704 | 3 Nos. 16 Amps MCB outgoing along with 3 Nos. DOL starter for AHU 2.2 kw motor. (One Spare) |
| 1705 | 3 Nos. 10 Amps MCB outgoing along with 3 Nos. DOL starter for AHU 1.5 kw motor. (One Spare) |
| 1706 | 2 Nos. 10 Amps MCB outgoing along with 2 Nos. DOL starter for AHU 1.1 kw motor. (One Spare) |
| 1707 | Supply, installation, testing & commissioning of sub panel board cubical compartmentalised, floor mounted made of2.0mmthick steel sheet duly painted complete withvoltmeter, ammeter, indicatinglights for selectorswitch,incoming/outgoingfeedersCTS contactorsfor complete asperspecifications andrequired. |
| 1708 | 3 Nos. 25 Amps MCB outgoing along with 3 Nos. DOL starter for Axial fan 5.5 kw motor. (One Spare) |
| 1709 | 2 Nos. 16 Amps MCB outgoing along with 2 Nos. DOL starter for Axial fan 3.7 kw motor. (One Spare) |
| 1710 | Supply, installation, testing & commissioning of sub panel board cubical compartmentalised, floor mounted made of2.0mmthick steel sheet duly painted complete withvoltmeter, ammeter, indicatinglights for selectorswitch,incoming/outgoingfeedersCTS contactorsfor complete asperspecifications andrequired. |
| 1711 | 3 Nos. 32 Amps MCB outgoing along with 3 Nos. star delta starter for airwasher and scrubber 7.5 kw motor. (One spare)3 Nos. 5 Amps MCB outgoing for Airwasher &Scrubber pump.(One Spare) |
| 1712 | Electrical Panle For Level 88.65 M (VRV) |
| 1713 | Supply, installation, testing & commissioning of sub panel board cubical compartmentalised, floor mounted made of2.0mmthick steel sheet duly painted complete withvoltmeter, ammeter, indicatinglights for selectorswitch,incoming/outgoingfeedersCTS contactorsfor complete asperspecifications andrequired. |
| 1714 | INCOMING:1 No.63A 415 volt 10 kA 4P MCCB with microprocessor based release. |
| 1715 | BUS BAR:Electrolyte high conductivity aluminium three phase and neutral busbars rated at 100 A. having a maximum current density of 1 amp. Per sq.mm. Suitable to with stand symmetrical fault level of 25 MVA at 415 volts. The netutral busbars is to be of 50% capacity.INDICATING PANEL:Incomer shall have the following indicating panel.Single phase Digital Voltmeter, 96mm sq., 0-100 volt with 3 way ON/OFF selector switch.Three nos. 100/5 class 1.0 accuracy 15 VA burden C.T.s for metering.Single phase Digital Ammeter 0-100 amps for CT ratio 100/5A with 3 way ON/OFF selector switch.Three phase indicating lights.LED type with control fuses for protection |
| 1716 | OUTGOING UNITS:2 Nos. 40A. 415 volts 4P RCBO. (25 kA) with thermal magnetic release - for Outdoor Unit.(1 No.Spare)2 Nos. 6A. 220-240 volts 2P MCB - (10 kA) with thermal magnetic release - for Indoor unit 3.1 TR, 2.02 TR(1 No.Spare)The switchboard shall be complete with all interconnection risers internal wiring lables etc. complete as required. |
| 1717 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 1718 | Overall size 400sq.mm (3½ Core) Armoured (Loose) |
| 1719 | 4 C - 10 sqmm (Copper for VRV Outdoor Unit) |
| 1720 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 6sq.mm (4Core) Armoured (Loose) |
| 1721 | Overall size 4sq.mm (3Core) Armoured (Loose) |
| 1722 | 4 C - 1.5 sqmm |
| 1723 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 1724 | Overall size 2.5sq.mm (50/0.25mm), 3Core |
| 1725 | Cable Tray |
| 1726 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 1727 | Cable Tray Size 450mm x 50mm x 50mm (2mm thick) |
| 1728 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 1729 | PVC Pipe / PVC Tray |
| 1730 | Supply and installaiton of150 mm dia PVC pipes / tray for running refrigerant pipes thru shaft. |
| 1731 | Control & Transmission Wiring |
| 1732 | Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (48/0.20mm), 2Core |
| 1733 | Controller Wiring |
| 1734 | Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (48/0.20mm), 2Core |
| 1735 | Switchgear |
| 1736 | Supply and installaiton of 63 Amps 4P MCCB near each outdoor unit. |
| 1737 | Earthing |
| 1738 | Supply and laying of double earthing continuity conductors of G.I. /G.S.S between panel boards and equipments as drawings. (May be checked at site). |
| 1739 | Providing & fixing of 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1740 | Providing & fixing of 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 1741 | Total; |
| 1742 | PID Valves |
| 1743 | Supply, installation, testing and commissioning of 2 way modulating valve cum pressure independent balancing valve along with actuator & proportionate thermostat, transformer complete as per specifications and drawings. |
| 1744 | 100 mm dia |
| 1745 | 65 mm dia |
| 1746 | 50 mm dia |
| 1747 | Insulated Chilled / HotWater Piping (Nitrile Rubber Insulation) |
| 1748 | Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled/hot water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastomeric nitrile rubber of class \"O\" insualtion applied by adhesive cofirming to standard specifications and finally applying 0.63 mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS : 1322 as amended upto date) at joints and repairing of damage to building etc. as per specifications and as required complete in all respect. |
| 1749 | Note : The pipes size 150 mm and below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS : 3589 from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm dia and for minimum 7 mm thick M.S. sheet for pipes for 400 mm dia and above. |
| 1750 | Piping |
| 1751 | 125 mm (32 mm thick insulation) |
| 1752 | 100 mm (32 mm thick insulation) |
| 1753 | 80 mm (32 mm thick insulation) |
| 1754 | 65 mm (32 mm thick insulation) |
| 1755 | 50 mm (32 mm thick insulation) |
| 1756 | Insulated Valves |
| 1757 | Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled/hot water plumbing duly insulated tothe same specifications as the connected piping andadequately supported as per specifications. |
| 1758 | Supply, installation, testing and commissioning of Motorized Butterfly Valves along with Controls Actuators, Control Wiring,Transformer etc. |
| 1759 | 125 mm dia |
| 1760 | Butterfly Valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled/hot wate circulation as specified. |
| 1761 | 125 mm |
| 1762 | 100 mm |
| 1763 | 65 mm |
| 1764 | 50 mm |
| 1765 | Balancing Valve with Built in Measuring Facility with C I body flanged construction with EPDM coated disc with longpitch with protected out pipe insulation & PN 16 pressure rating for chilled/hot water circulation as specified. |
| 1766 | 125 mm |
| 1767 | Non Return Valves |
| 1768 | Non return valve with dual plate of CI body and SS plates vulcanized NBR seal flanged and PN 16 pressure rating for chilled/hotwater circulation including insulation as specified. |
| 1769 | 125 mm |
| 1770 | Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation includinginsulation as specified. |
| 1771 | 125 mm |
| 1772 | 100 mm |
| 1773 | 65 mm |
| 1774 | 50 mm |
| 1775 | Pot Strainer |
| 1776 | 125 mm |
| 1777 | Flexible Connection |
| 1778 | 125 mm |
| 1779 | Water flow switch |
| 1780 | Providing and fixing of in position the industrial type pressure gauges with gun metal / brass valves complete as required. |
| 1781 | Providing and fixing of in position the mercury in glass industrialtype thermometers. |
| 1782 | Auto Airvent 25 mm dia |
| 1783 | Burried Chilled/Hot Water Piping |
| 1784 | Suppluing, laying / fixing, testing and commissioning of following nominal sizes of chilled/hot water piping outside the builiding (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with PUF insualtion 36+2 kg /cum density, pipe section insulation covered with two layer of 120 gm/sqm polythene sheet (vapour barrier), chicken wire mesh and finished with tow coat PARACOAT- BPC of density 1.12 to 1.2 / kg. |
| 1785 | Note : The pipes size 150 mm and below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS : 3589 from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm dia and for minimum 7 mm thick M.S. sheet for pipes for 400 mm dia and above. |
| 1786 | 125 mm |
| 1787 | Exposed Chilled / Hot Water Piping |
| 1788 | Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled / hot water piping outside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainer, gauges etc.) duly insulated with PUF insulation 36+2 kg/cum density, pipe section insulation covered with two layer of 120 gm/sqm polythene sheet (vapour barrier) chicken wire mesh and finished with 26 ga aluminium cladding.Note : The pipes size 150 mm and below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS : 3589 from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm dia and for minimum 7 mm thick M.S. sheet for pipes for 400 mm dia and above. |
| 1789 | 125 mm |
| 1790 | Air & Dirt Separator |
| 1791 | Supply, installation, testing and commissioning of Air & dirt separator mild steel construction, unit shall be able to remove free air and micro bubbles as well as remove solid particles upto 10 microns. Unit shall be as per specifications & drawings. |
| 1792 | 125 mm dia (Working pressure 3.5 bar) |
| 1793 | Drain Piping |
| 1794 | Supply and Installation ofPVC piping complete withfittings, supports as per specifications and dulyinsulated with6 mmthick closed cell nitrile rubber insulation. |
| 1795 | 50 mm dia |
| 1796 | 40 mm dia |
| 1797 | 32 mm dia |
| 1798 | Sarai BuildingZone-5 |
| 1799 | Variable Refrigerant Volume System |
| 1800 | Supply, installation, testing and commissioning of variable refrigerant volume modular typeairconditioning system complete with indoorand out door units with individual controller and with refrigerant piping, gas charging R-410, M.S. stand, control cabling asper detailgiven in specifications and having following items: |
| 1801 | Outdoor Unit |
| 1802 | 36 HP(28.8 TR) |
| 1803 | 12 HP(9.6 TR) |
| 1804 | 10 HP(8.0 TR) |
| 1805 | Indoor Units |
| 1806 | Vertical floor standing duct type / floor stanidng AHU type 6072 cfm (15.9 Tons). |
| 1807 | Vertical floor standing duct type / floor stanidng AHU type 4730 cfm (12.8 Tons). |
| 1808 | VRV ductable unit 2542 cfm (7.95 Tons) |
| 1809 | VRV round flow cassette unit 1130 cfm (3.18 Tons) |
| 1810 | Imported fittings Y-jointsand headers etc. |
| 1811 | Corded remote controls |
| 1812 | Main centrallised controller suitable for groups of indoor units. |
| 1813 | HRV Unit |
| 1814 | Supply, installation, testing and commissioning of heat reclaim ventilation unit with inlet and exhaust blower with fan (Inlet & exhaust) desiccant absorption material non contact seal, modular design with Aluminium supports of extruded section, galvanized steel plate casing, self extinguishable polyurethene foam insulation, multi-directional fibrous fleeces air filtercomplete as per requirements. |
| 1815 | 2000 CMH |
| 1816 | Refrigerant Piping |
| 1817 | Supply and installaiton of Interconnecting copper, refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor & outdoor units as perspecifications, all piping inside the buildingshallbe properlysupportedwith MS hanger and shall run in cable trayand all external piping shall run in covered cable tray. |
| 1818 | 41.3 mm O.D.(insulation : 19 mm) (1.2 mm thickness) |
| 1819 | 34.9 mm O.D.(insulation : 19 mm) (1.2 mm thickness) |
| 1820 | 28.6 mm O.D.(insulation : 13 mm) (1.00 mm thickness) |
| 1821 | 22.2 mm O.D.(insulation : 13 mm) (1.00 mm thickness) |
| 1822 | 19.1 mm O.D.(insulation : 13 mm) (1.00 mm thickness) |
| 1823 | 15.9 mm O.D.(insulation : 13 mm) (1.00 mm thickness) |
| 1824 | 12.7 mm O.D.(insulation : 13 mm) (0.80 mm thickness) |
| 1825 | 9.5 mm O.D.(insulation : 13 mm) (0.80 mm thickness) |
| 1826 | Packaged Type Airwasher |
| 1827 | Providing, fixing, testing and commissioning packaged type airwasher in double skin construction comprising of DIDW backward curved centrifugal blower, TEFC energy efficient motor, belt, drive packaged, 50 mmthick 7 layer aluminium wire meshfilters, stainless steel 18 Gwetsection, 16 G SS bottom panel of blower section, locable volume control damper of G.I. at fan outlet, 200 mm cellulose paper pads of 90% efficiency, with 100 mm wide PVC eleminator, M.S. reinforced, piping, FRP distributor, double layer canvas connections 1 No. monobloc pump set along with fittings for capacities Mentioned below, M.S. frame for supports as per specification & drawings. |
| 1828 | 10,000 CFMat 30 mmwg static pressure |
| 1829 | Exhaust Scrubber |
| 1830 | Providing, fixing, testing and commissioning of weather proof double skin DIDW centrifugal exhaust scrubber with fan with motor and drive (both fan and motor shall be mounted on a common frame using cushy foot mounting) with back suction and frontdischarge including vibration isolator, water tank with float valve, pump, distributor, nozzels, eleminator, piping & valve from tank to pump to distributor and M.S. frame for supports etc. as per specifications and drawings. |
| 1831 | 11,000 cfm, 30 mm static pressure |
| 1832 | Inline Fans |
| 1833 | Supply, installation, testing and commissioning of inline ducted fans of G.I. construction complete with centrifugal fan with motor, drive, canvassconnection at inlet & outlet complete with MCB panel with cabling and earthing(with 5 Rm). Fan shall be suitable for operation on 220+6% volts, 50 Hz, 1 Phase AC power supply. All single phase inline fans shall be provided with factory filled speed regulation and as per specification and drawings. |
| 1834 | 400 cfm, 10 mmwg S.P. |
| 1835 | Drain Piping |
| 1836 | Supply and Installation ofPVC piping complete withfittings, supports as per specifications and dulyinsulated with6 mmthick closed cell nitrile rubber insulation. |
| 1837 | 50 mm dia |
| 1838 | 40 mm dia |
| 1839 | 32 mm dia |
| 1840 | Ducting |
| 1841 | Supply and installaiton ofsheet metal ducting complete with supports, neoprone gaskets, vanes, dampers etc.as per specifications & drawings. |
| 1842 | G.I. Sheet Metal Ducting (Rectangular) |
| 1843 | 0.63 mm (24 Ga) |
| 1844 | 0.80 mm (22 Ga) |
| 1845 | 1.00 mm (20 Ga) |
| 1846 | 1.25 mm (18 Ga) |
| 1847 | Insulation |
| 1848 | Supplying and fixing of following thickness duly laminated aluminum foilof mat finish closed cell Nitrile rubber (class \"O\") insulation on existing duct after applying two coats of coldsetting adhesive (CPRXcompound). The joints shall sealed with50 mm wide and 3 mm thick self adhesive nitrile rubber tapeinsulation complete as per specifications and as required. |
| 1849 | 19 mm thick |
| 1850 | Supply and installation of nitrile rubber insulation on ducts complete as per specifications and drawings. |
| 1851 | 9 mm thick |
| 1852 | Acoustic Insulation for AHU Room |
| 1853 | Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25 X 50 X50 X 50 X 25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc.complete as required and as per specifications. |
| 1854 | Duct Acoustic Lining |
| 1855 | Supply & installation ofduct acoustic lining with open cell nitrile rubber insulation of below mention thickness as per specifications and drawings. |
| 1856 | 15 mm thick |
| 1857 | Grills/Diffusers |
| 1858 | Supply, installation, testing and commissioning of Aluminium extruted powder coated supplyand returnairgrilles/ diffusers as per specifications and drawings (Approval of colour shall be taken from Architects/Consultants). |
| 1859 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. |
| 1860 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers butwithout volume control dampers complete as required. |
| 1861 | Supplying, fixing testing commissioning of supply / return air diffusersof powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. |
| 1862 | Volume Control Damper |
| 1863 | Supply, installation,testing & commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. |
| 1864 | Flexible Duct |
| 1865 | Supply and installaiton ofaluminium wired flexible insulated duct complete as per specifications and drawings. |
| 1866 | 350 mm dia |
| 1867 | Fresh air Grilles |
| 1868 | Supply and installation of Fresh air grille of 18 Ga G.I. withlouvers, bird Screen and damper as per specifications and drawings. |
| 1869 | Flexible Duct Connection |
| 1870 | Supply and installaiton ofFire retardant non porous doublelayerflexible connectionbetweeneach indoor unit and duct. |
| 1871 | Fire Damper |
| 1872 | Supplying, fixing, testing and commissioning of fire dampers insupply air duct/main branch and return air path as and wherere quired of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signalcomplete as required and as per specifications. |
| 1873 | Fire dampers |
| 1874 | Actuator assembly (10 NM) |
| 1875 | PVC Pipe / PVC Tray |
| 1876 | Supply and installaiton of150 mm dia PVC pipes / tray for running refrigerant pipes thru shaft. |
| 1877 | Control & Transmission Wiring |
| 1878 | Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (48/0.20mm), 2Core |
| 1879 | Controller Wiring |
| 1880 | Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (48/0.20mm), 2Core |
| 1881 | Switchgear |
| 1882 | Supply and installaiton of 63 Amps 4P MCCB near each outdoor unit. |
| 1883 | Cable Tray |
| 1884 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 1885 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 1886 | Electrical Panel Board (Airconditioning) |
| 1887 | Distribution Boards and Panels |
| 1888 | Design, fabrication, assembling, wiring and supply installation, connecting, testing & commissioning of following totaly enclosed, compartmentalized, indoor mounting, free standing, front operated, dust & vermin proof IP 42, distribution panels fabricated out of 14/16 gauge CRCA sheet steel in cubicle formation with reinforcement of suitable size angle iron, channels irons, flats wherever necessary for large distribution panels. The boards shall be treated with all anticorrosive process before painting as per standards with Powder coated with seven tank process with final approved shade of enameled paint, 2 Nos. earthing terminals shall be provided for 3 phase distribution panels. The panels shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall be fabricated in easily transportable sections & length, height, depth etc to match with site conditons, including the cost of interconnections with heavy duty copper crimping lugs, bonding to earth suitable for a fault level of 25 MVA symmetrical at 415 volts, as per the technical specification complete in all respect as required. Prior approval of GA drawing and scheme of panel shall be taken for each panel before final manufacture. Galvanized hardware with zinc passivation shall be used in fabrication of boards. Suitable earth bus to be provided throughout length of Panels. |
| 1889 | All switchboardshall have provision for entry of cables from the top and bottom as required. |
| 1890 | All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves. SMC / DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders; doors and switch handles shall be lockable in OFF position. |
| 1891 | AC MAIN PANEL INCOMING:1 No. 250A 415 volt 35 kA 4P MCCB with microprocessor based release. |
| 1892 | BUS BAR:Electrolyte high conductivity aluminium three phase and neutral busbars rated at 400 A. having a maximum current density of 1 amp. Per sq.mm. Suitable to with stand symmetrical fault level of 25 MVA at 415 volts. The netutral busbars is to be of 50% capacity. |
| 1893 | INDICATING PANEL:Incomer shall have the following indicating panel.Single phase Digital Voltmeter, 96mm sq., 0-400 volt with 3 way ON/OFF selector switch.Three nos. 400/5 class 1.0 accuracy 15 VA burden C.T.s for metering.Single phase Digital Ammeter 0-400 amps for CT ratio 400/5A with 3 way ON/OFF selector switch.Three phase indicating lights.LED type with control fuses for protection |
| 1894 | OUTGOING UNITS:5 Nos. 40A. 415 volts 4P, RCBO - (300 mAsensitivity) (1 No.Spare).3 Nos. 25A. 415 volts 4P RCCB - (10 kA) with thermal magnetic release - for Floor Standing Unit / AHU (1 No.Spare)3 Nos. 16A. 220-240 volts 2P MCB - (10 kA) with thermal magnetic release - for Ductable Unit / HRV Unit (1 No.Spare)4 Nos. 6A. 220-240 volts 2P MCB - (10 kA) with thermal magnetic release - for Cassette Unit (1 No.Spare)The switchboard shall be complete with all interconnection risers internal wiring lables etc. complete as required. |
| 1895 | Supply, installation, testing & commissioning of sub panel board cubical compartmentalised, floor mounted made of2.0mmthick steel sheet duly painted complete withvoltmeter, ammeter, indicatinglights for selectorswitch,incoming/outgoingfeedersCTS contactorsfor complete asperspecifications andrequired. |
| 1896 | 3 Nos. 16 Amps MCB outgoing along with 3 Nos. DOL starter for airwasher and scrubber 3.7 kw motor. (One spare) |
| 1897 | 3 Nos. 5 Amps MCB outgoing for Airwasher &Scrubber pump.(One Spare) |
| 1898 | Power Cabling |
| 1899 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 1900 | Overall size 50sq.mm (3½ Core) Armoured (Loose) |
| 1901 | 4 C - 10 sqmm (Copper for VRV Outdoor Unit) |
| 1902 | 4 C - 6 sqmm (Copper) |
| 1903 | 4 C - 4 sqmm (Copper) |
| 1904 | Overall size 4sq.mm (3Core) Armoured (Loose) |
| 1905 | 4 C - 1.5 sqmm |
| 1906 | Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 1907 | Overall size 1.0sq.mm (32/0.20mm), 2Core |
| 1908 | Earthing |
| 1909 | Supply and laying of double earthing continuity conductors of G.I. /G.S.S between panel boards and equipments as drawings. (May be checked at site). |
| 1910 | Providing & fixing of 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1911 | Providing & fixing of 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 1912 | SEWERAGE AND DRAINAGE WORK |
| 1913 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths asshown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boningrods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. Depth not exceeding 3 m. BGL For Semi Conglomerate soil having gravel/boulder above 40% up to 50% |
| 1914 | For depth exceeding 3.00 m but not exceeding 4.5 B.G.L For Semi Conglomerate soil having gravel/boulder above 40% up to 50% |
| 1915 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concretemixer volumetric type |
| 1916 | Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as perIS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing ofrubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc. R.C.C. Pipe NP -3 600mm i/d pipe |
| 1917 | Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as perIS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing ofrubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc. R.C.C. Pipe NP -4 1000mm i/d pipe |
| 1918 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard designcomplete in all respects. Inside size 150x180 cm and 120 cm deep |
| 1919 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 upto 1.80 m increase in depth. Inside size 150x180 cm |
| 1920 | 1.2m to 1.5m |
| 1921 | 1.5m to 1.8m |
| 1922 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 beyond 1.80 m upto 4.5 m beyond addiational depth. Inside size 150x180 cm |
| 1923 | 1.8m to 2.1m |
| 1924 | 2.1m to 2.4m |
| 1925 | 2.4m to 2.7m |
| 1926 | 2.7m to 3.0m |
| 1927 | 3.0m to 3.3m |
| 1928 | 3.3m to 3.6m |
| 1929 | 3.6m to 3.9m |
| 1930 | 3.9m to 4.2m |
| 1931 | 4.2m to 4.5m |
| 1932 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) infoundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 600mm x 900mm inside with 455mm x455mm cover and frame light duty double seal |
| 1933 | Extra for filling earth in 15 cm layers and compaction |
| 1934 | ELECTRICAL SERVICES |
| 1935 | ENTRANCE PLAZA, BASEMENT (ZONE-1): |
| 1936 | POINT & SUBMAIN WIRING: |
| 1937 | REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point)and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01) |
| 1938 | Wiring fan point with sheet metal fan box |
| 1939 | Wiring light point |
| 1940 | Wiring call-bell point |
| 1941 | Wiring 3 pin 6 Amp. wall socket point |
| 1942 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket point |
| 1943 | Wiring 3 pin 16/20 amp. power plug control point |
| 1944 | COPPER WIRES & CONDUIT PIPE: |
| 1945 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 1946 | Overall size 1sq.mm (Un-sheathed) |
| 1947 | Overall size 1.5sq.mm (Un-sheathed) |
| 1948 | Overall size 2.5sq.mm (Un-sheathed) |
| 1949 | Overall size 4sq.mm (Un-sheathed) |
| 1950 | Overall size 6sq.mm (Un-sheathed) |
| 1951 | Overall size 10sq.mm (Un-sheathed) |
| 1952 | Overall size 16sq.mm (Un-sheathed) |
| 1953 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 1954 | Heavy Gauge PVC Conduit Pipe 20mm dia. (Flushed) |
| 1955 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 1956 | Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) |
| 1957 | Heavy Gauge PVC Conduit Pipe 20mm dia. (On-surface) |
| 1958 | Heavy Gauge PVC Conduit Pipe 25mm dia. (On-surface) |
| 1959 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 1960 | PVC flexible pipe 40mm dia. |
| 1961 | Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:- |
| 1962 | PVC compression Socket gland 40mm dia. |
| 1963 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Casing \"n\" Capping (Double Lock) ISI markedfor wiring purposes including cost of bends (L), (U), (T) & inspection boxes etc., where necessary including other petty material:- |
| 1964 | PVC Casing \"n\" Capping Size 20mm x 12mm |
| 1965 | PVC Casing \"n\" Capping Size 25mm x 16mm |
| 1966 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):- |
| 1967 | Powder Coated Concealed Metal Box with Brass Lugs One/Two Module |
| 1968 | Powder Coated Concealed Metal Box with Brass Lugs Three Module |
| 1969 | Powder Coated Concealed Metal Box with Brass Lugs four Module |
| 1970 | Powder Coated Concealed Metal Box with Brass Lugs Six Module |
| 1971 | Powder Coated Concealed Metal Box with Brass Lugs Eight Module |
| 1972 | Powder Coated Concealed Metal Box with Brass Lugs Twelve Module |
| 1973 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 1974 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 1975 | MAIN /SUB DISTRIBUTION BOARDS & DISTRIBUTION BOARDS: |
| 1976 | ZONE-1 |
| 1977 | LT PANELS & MCCB\"s (MOULDED CASE CIRCUIT BREAKERS):Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication: Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . |
| 1978 | Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB\"s. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following:- |
| 1979 | MDB-ENTRANCE PLAZA, UPPER BASEMENT: |
| 1980 | LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB\"s40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm) (DETAIL SEE IN THE PANEL INVENTORY) |
| 1981 | MCCB\"s (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevantPWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc |
| 1982 | MCCB Four Pole 100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 1983 | MCCB Four Pole 80amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 1984 | MCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 1985 | EMDB- ENTRANCE PLAZA, UPPER BASEMENT: |
| 1986 | Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP44).Fabrication: Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS:8623. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The base channel will be made out of 75mm x 40mm x 5mm rolled channel. \"The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. |
| 1987 | Painting:The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work. Busbars: The panel shall be provided with TPN copper busbar of suitable size according to the size of MCCB\"s.All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard). The Concerned contactor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of ACB/MCCB\"s to be installed in the cubical panel Enclosure (including the cost of MCCB\"s+E.R.H.) as per following. |
| 1988 | Incomer:¦ MCCB 630A, 415V breaking capacity =36kA 4P microprocessor based adjustable thermal and magnetic protection= 1No.Outgoings: ¦ MCCB 250A, 415V breaking capacity =36kA 4P microprocessor based adjustable thermal and magnetic protection= 3Nos.¦ MCCB 200A, 415V breaking capacity =25kA 4P microprocessor based adjustable thermal and magnetic protection= 4Nos.¦ MCCB 100amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 3Nos.¦ MCCB 40amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 9Nos.¦All Incomers & Out going With Extendable Rotary Handle with adjustable depth complete as per schematic diagram attached & Satisfaction of the Engineer in charge at site.Enclosure:Panel Size: As per NormsPanel builders Make: Kalyani Switchgear, ETE Electrogears, Power Associates, Unix, CMKL |
| 1989 | ESDB- UPPER BASEMENT: |
| 1990 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB\"s as incomer and outgoings SP/TPminiature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 1991 | TP&NDouble Door Vertical DB\"s 4 way each (With provision of FP MCCB upto 125amp) |
| 1992 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 1993 | MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 1994 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 1995 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 1996 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 1997 | SP&N Double Door Distribution Board 8 way each |
| 1998 | TP&N Vertical Double Door Distribution Board4 way each. |
| 1999 | TP&N Vertical Double Door Distribution Board 8 way each. |
| 2000 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 2001 | Cable End Box for SPN 8 Way |
| 2002 | Cable End Box for TPN Vertical 4/8/12Way |
| 2003 | MCB\"S & MCB DISTRIBUTION BOARDS: |
| 2004 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 2005 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 2006 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 2007 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 2008 | RCCB\"s:Supply and erection of RCCB (Residual Current Circuit Breaker) for Earth leakage protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kAas per IEC 61008-1 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 2009 | RCCB Double Pole 32/40amp., Sensitivity 100mA |
| 2010 | CABLES & SUBMAIN WIRING: |
| 2011 | XLPE INSULATED ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 2012 | Overall size 25sq.mm (3½ Core) Armoured (On-Surface) |
| 2013 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 2014 | Aluminium thimble cable Core size 10 -16sq.mm |
| 2015 | Aluminium thimble cable Core size 25 -35sq.mm |
| 2016 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections |
| 2017 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 25-35sq.mm |
| 2018 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 2019 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 2020 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 2021 | Heavy Gauge PVC Conduit Pipe 50mm dia. (Flushed) |
| 2022 | CABLE TRAY: |
| 2023 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 2024 | Cable Tray Size 150mm x 50mm x 50mm (2mm thick) |
| 2025 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 2026 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 2027 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 2028 | Double walled corrugated (DWC) HDPE pipe 90/76mm (outer/ inner dia.) |
| 2029 | Double walled corrugated (DWC) HDPE pipe160/136mm (outer/ inner dia.) |
| 2030 | EARTHING SYSTEM: |
| 2031 | G.I. EARTHING:Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 2032 | Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length) |
| 2033 | COPPER EARTHING (Upto 8 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc.,up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 2034 | Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) |
| 2035 | COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 2036 | Additional Length 20mm x 3mm thick Copper Tape |
| 2037 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc. |
| 2038 | Additional length G.I. rope 7/14 S.W.G. (7/2.18mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 2039 | LIGHT FIXTURES AND FANS: |
| 2040 | Supply and erection of LED batten 20watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Philips BN02IC LED20S PSU CW GRS2, Havell\"s ENDURALINEARNEOBS20WLED865SPCWH,Crompton CCS-103-20-65-SL-DP-NWH, Wipro LL20-281-XXX-65 ALI, Panasonic PBTM08208, Bajaj BCLAB 20W WH LED P |
| 2041 | S/E of LED 18 watt surface mounted downlighter (including LED driver) with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Crompton Cat No.LCDSPLN-R-18CDL, WIPRO Cat No. LD80-171-XXX-60-SM, Bajaj Cat No-BZSLOS NXT 18L LED WH SD |
| 2042 | Supply, installation, testing and commissioning of 6 watt LED (including LED driver) burried in ground light fixture complete as required and all accessories as required. Wipro LI20-600-030-30-XX or its equivalent |
| 2043 | Supply, Installation, Testing and Commissioning of 35W, 24V DC Driver suitable for under water luminaires complete in all respect with satisfaction of the Engineer-in-charge.MAKE: WIPRO Cat. No.LPV-35-12/24 (For IN Ground Burried Fixtures) or its equivalent |
| 2044 | Supply and erection of LED batten 10watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Wipro Cat. No.LL20-111-XXX-65NE3, Bajaj Cat No.BCLSB10NW, Crompton Cat. No.CCS-103-10-65-SL-DP-NWH |
| 2045 | S/E of LED 12 watt recessed mounted downlighter (including LED driver) with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Crompton Cat No.CDR-205-12-57-SL-NWH, WIPRO Cat No. LD90-141-XXX-65-XX, Bajaj Cat No-BZSLO NXT 12L LED WH SD |
| 2046 | Supply and erection ofLEDBulk Head 9/10 wattIP65 surface mounted, pressure die cast housing complete in all respects as approved. and desired by the Engineer in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATBP/20/GL Dated 30/11/2017Make:-CROMPTON Cat No. LBHE10CDL, Philips Cat. No.WT202W LED6S NW PSU S2 PC,WIPRO Cat. No. LW07-141-XXX-57-XX, Bajaj Cat. No. BIBWP 10W LED. |
| 2047 | Supply, installation, testing and commissioning of Step light recess mounted 4-6W LED fixture (including driver) and all accessories as required. Make: Crompton Cat. No. LSL-6-CDL, Bajaj Cat. No.BLSGV 4W LED WH, Havell\"s Cat. No. RADIANTNEOFT07WLED830SASYMBOPC |
| 2048 | S/E of M S powder coated & glass finsihed 5 x 9 W Surface mounted cluster light fixture with 9W LED Lamp and all accessories as required with complete satisfaction of Engineer-in-charge.Decon Cata. Ref. 03RN. or its equivalent |
| 2049 | Supply, installation, testing and commissioning of 5-6 watt per meter (Low) Flexible strip light with Driver and all accessories as required of Bajaj Cat. No. .NXT 25W PROFESSIONAL LED STRIP IP20 WH, Wiro Cat. No. LS06-005-120-65-50, Havell\"s Cat. No. FLEXISTRIP5MIP2024V/1ALED865S |
| 2050 | SUPPLY AND ERECTION OF WIRING ACCESSORIES: |
| 2051 | Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,:- |
| 2052 | Bakelite Batten Holder (Large size) |
| 2053 | Supply and erection of Ceiling Fan 1200mm (48\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High SpeedOpel White, Orient- New Breeze, Havell\"s Velocity HS or equivalent. |
| 2054 | Supply and erection of Ceiling Fan 900mm (36\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High SpeedOpel White, Orient- New Breeze, Havell\"s Velocity HS |
| 2055 | Supply and erection of Heavy duty Exhaust Fans 300mm, 900RPM with aluminium louver shutter, double ball bearinglonger life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make: Crompton EXHD300-6-1, Havells Turbo Force SP, Orient (Heavy Duty) |
| 2056 | TELEPHONE & EPABX SYSTEM: |
| 2057 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 2058 | Wiring Telephone socket point RJ11 (one module) |
| 2059 | Supply & erection of20 Pair 0.5mm jelly filled Armored cable manufactured as per ITD specification with up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton, Finolex, RR kabel, Polycab, Shalimar. |
| 2060 | Supply and erection of 30 pairs MDF with krone modules & lockable box complete in all respect as desired by the engineer in charge at site. Make: Krone, M-Tel, Reliance, A-Tel, Airtele |
| 2061 | SANGAT HALL (ZONE-2): |
| 2062 | POINT & SUBMAIN WIRING: |
| 2063 | REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point)and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01) |
| 2064 | Wiring fan point with sheet metal fan box |
| 2065 | Wiring light point |
| 2066 | Wiring call-bell point |
| 2067 | Wiring 3 pin 6 Amp. wall socket point |
| 2068 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket point |
| 2069 | Wiring 3 pin 16/20 amp. power plug control point |
| 2070 | COPPER WIRES & CONDUIT PIPE: |
| 2071 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 2072 | Overall size 1sq.mm (Un-sheathed) |
| 2073 | Overall size 1.5sq.mm (Un-sheathed) |
| 2074 | Overall size 2.5sq.mm (Un-sheathed) |
| 2075 | Overall size 4sq.mm (Un-sheathed) |
| 2076 | Overall size 6sq.mm (Un-sheathed) |
| 2077 | Overall size 10sq.mm (Un-sheathed) |
| 2078 | Overall size 16sq.mm (Un-sheathed) |
| 2079 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 2080 | Heavy Gauge PVC Conduit Pipe 20mm dia. (Flushed) |
| 2081 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 2082 | Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) |
| 2083 | Heavy Gauge PVC Conduit Pipe 20mm dia. (On-surface) |
| 2084 | Heavy Gauge PVC Conduit Pipe 25mm dia. (On-surface) |
| 2085 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 2086 | PVC flexible pipe 40mm dia. |
| 2087 | Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:- |
| 2088 | PVC compression Socket gland 40mm dia. |
| 2089 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Casing \"n\" Capping (Double Lock) ISI markedfor wiring purposes including cost of bends (L), (U), (T) & inspection boxes etc., where necessary including other petty material:- |
| 2090 | PVC Casing \"n\" Capping Size 20mm x 12mm |
| 2091 | PVC Casing \"n\" Capping Size 25mm x 16mm |
| 2092 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):- |
| 2093 | Powder Coated Concealed Metal Box with Brass Lugs One/Two Module |
| 2094 | Powder Coated Concealed Metal Box with Brass Lugs Three Module |
| 2095 | Powder Coated Concealed Metal Box with Brass Lugs four Module |
| 2096 | Powder Coated Concealed Metal Box with Brass Lugs Six Module |
| 2097 | Powder Coated Concealed Metal Box with Brass Lugs Eight Module |
| 2098 | Powder Coated Concealed Metal Box with Brass Lugs Twelve Module |
| 2099 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 2100 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 2101 | MAIN /SUB DISTRIBUTION BOARDS & DISTRIBUTION BOARDS: |
| 2102 | ZONE-2 |
| 2103 | LT PANELS & MCCB\"s (MOULDED CASE CIRCUIT BREAKERS):Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication: Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . |
| 2104 | Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB\"s. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following:- |
| 2105 | EMDB-SANGAT HALL: |
| 2106 | LT Panel enclosure having space for 1No. Incomer MCCB 400Amp. and 10Nos. outgoing MCCB\"s40amp. to 160amp. according to the requirement at site (Approx. size 2025 x 1800 x 400mm) |
| 2107 | SDB-SANGAT HALL: |
| 2108 | LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCB\"s40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm) |
| 2109 | MCCB\"s (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevantPWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc. |
| 2110 | MCCB Four Pole 250amp., 415volts, =36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 2111 | MCCB Four Pole 100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2112 | MCCB Four Pole 63amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2113 | MCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2114 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 2115 | TP&N Vertical Double Door Distribution Board4 way each. |
| 2116 | TP&N Vertical Double Door Distribution Board 8 way each. |
| 2117 | TP&NVertical Double Door Distribution Board 12 way each |
| 2118 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 2119 | Cable End Box for TPN Vertical 4/8/12Way |
| 2120 | MCB\"S & MCB DISTRIBUTION BOARDS: |
| 2121 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 2122 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 2123 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 2124 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 2125 | RCCB\"s:Supply and erection of RCCB (Residual Current Circuit Breaker) for Earth leakage protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kAas per IEC 61008-1 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 2126 | RCCB Double Pole 32/40amp., Sensitivity 100mA |
| 2127 | RCCB Double Pole 63amp., Sensitivity 100mA |
| 2128 | CABLES & SUBMAIN WIRING: |
| 2129 | XLPE INSULATED ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 2130 | Overall size 6sq.mm (4Core) Armoured (On-Surface) |
| 2131 | Overall size 10sq.mm (4Core) Armoured (On-Surface) |
| 2132 | Overall size 16sq.mm (4Core) Armoured (On-Surface) |
| 2133 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 2134 | Aluminium thimble cable Core size 10 -16sq.mm |
| 2135 | Aluminium thimble cable Core size 25 -35sq.mm |
| 2136 | Aluminium thimble cable Core size 50sq.mm |
| 2137 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections |
| 2138 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 25-35sq.mm |
| 2139 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 50sq.mm |
| 2140 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 2141 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 2142 | Heavy gauge PVC conduit pipe 40mm dia. (Flushed) |
| 2143 | Heavy gauge PVC conduit pipe 50mm dia. (Flushed) |
| 2144 | CABLE TRAY: |
| 2145 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 2146 | Cable Tray Size 150mm x 50mm x 50mm (2mm thick) |
| 2147 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 2148 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 2149 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 2150 | Double walled corrugated (DWC) HDPE pipe 90/76mm (outer/ inner dia.) |
| 2151 | Double walled corrugated (DWC) HDPE pipe160/136mm (outer/ inner dia.) |
| 2152 | EARTHING SYSTEM: |
| 2153 | G.I. EARTHING:Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 2154 | Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length) |
| 2155 | COPPER EARTHING (Upto 8 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc.,up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 2156 | Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) |
| 2157 | COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 2158 | Additional Length 20mm x 3mm thick Copper Tape |
| 2159 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc. |
| 2160 | Additional length G.I. rope 7/14 S.W.G. (7/2.18mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 2161 | LIGHT FIXTURES AND FANS: |
| 2162 | Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Philips RC380B LED36S-6500 G4 L60 W60 PSU OD WH OC, Crompton LCTLRNE-36-FO-CDL (2X2), Wipro CRCO10R038HP57GL1, Bajaj BZRSQL 36W GZi WH |
| 2163 | S/E of LED 24 watt recessed mounted downlighter (including LED driver) with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Crompton Cat No.LCDSPLN-R-18CDL, WIPRO Cat No. LD06-301-XXX-57-XX**, Bajaj Cat No-BZSLO NXT 24L LED NW SD |
| 2164 | SUPPLY AND ERECTION OF WIRING ACCESSORIES: |
| 2165 | Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,:- |
| 2166 | Bakelite Batten Holder (Large size) |
| 2167 | Supply and erection of Ceiling Fan 1400mm (48\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High SpeedOpel White, Orient- New Breeze, Havell\"s Velocity HS or equivalent. |
| 2168 | Supply and erection of Heavy duty Exhaust Fans 300mm, 900RPM with aluminium louver shutter, double ball bearinglonger life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make: Crompton EXHD300-6-1, Havells Turbo Force SP, Orient (Heavy Duty) |
| 2169 | TELEPHONE & EPABX SYSTEM: |
| 2170 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 2171 | Wiring Telephone socket point RJ11 (one module) |
| 2172 | Supply & erection of20 Pair 0.5mm jelly filled Armored cable manufactured as per ITD specification with up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton, Finolex, RR kabel, Polycab, Shalimar. |
| 2173 | Supply and erection of 10 pairs MDF with krone modules & lockable box complete in all respect as desired by the engineer in charge at site. Make: Krone, M-Tel, Reliance, A-Tel, Airtele |
| 2174 | MUSEUM (ZONE-3) & ICONIC TOWER (ZONE-4): |
| 2175 | POINT & SUBMAIN WIRING: |
| 2176 | REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point)and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01) |
| 2177 | Wiring fan point with sheet metal fan box |
| 2178 | Wiring light point |
| 2179 | Wiring 3 pin 6 Amp. wall socket point |
| 2180 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket point |
| 2181 | Wiring 3 pin 16/20 amp. power plug control point |
| 2182 | COPPER WIRES & CONDUIT PIPE: |
| 2183 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 2184 | Overall size 1sq.mm (Un-sheathed) |
| 2185 | Overall size 4sq.mm (Un-sheathed) |
| 2186 | Overall size 6sq.mm (Un-sheathed) |
| 2187 | Overall size 10sq.mm (Un-sheathed) |
| 2188 | Overall size 16sq.mm (Un-sheathed) |
| 2189 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 2190 | Heavy Gauge PVC Conduit Pipe 20mm dia. (Flushed) |
| 2191 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 2192 | Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) |
| 2193 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 2194 | Heavy Gauge PVC Conduit Pipe 50mm dia. (Flushed) |
| 2195 | Heavy Gauge PVC Conduit Pipe 20mm dia. (On-surface) |
| 2196 | Heavy Gauge PVC Conduit Pipe 25mm dia. (On-surface) |
| 2197 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 2198 | PVC flexible pipe 40mm dia. |
| 2199 | Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:- |
| 2200 | PVC compression Socket gland 40mm dia. |
| 2201 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Casing \"n\" Capping (Double Lock) ISI markedfor wiring purposes including cost of bends (L), (U), (T) & inspection boxes etc., where necessary including other petty material:- |
| 2202 | PVC Casing \"n\" Capping Size 20mm x 12mm |
| 2203 | PVC Casing \"n\" Capping Size 25mm x 16mm |
| 2204 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):- |
| 2205 | Powder Coated Concealed Metal Box with Brass Lugs One/Two Module |
| 2206 | Powder Coated Concealed Metal Box with Brass Lugs Three Module |
| 2207 | Powder Coated Concealed Metal Box with Brass Lugs four Module |
| 2208 | Powder Coated Concealed Metal Box with Brass Lugs Six Module |
| 2209 | Powder Coated Concealed Metal Box with Brass Lugs Eight Module |
| 2210 | Powder Coated Concealed Metal Box with Brass Lugs Twelve Module |
| 2211 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 2212 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 2213 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 2214 | AC Plug and Socket TP&N with provision of One Triple Pole MCB 20amp. |
| 2215 | MAIN /SUB DISTRIBUTION BOARDS & DISTRIBUTION BOARDS: |
| 2216 | ZONE- 3 &4 |
| 2217 | LT PANELS & MCCB\"s (MOULDED CASE CIRCUIT BREAKERS):Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication: Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . |
| 2218 | Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB\"s. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following:- |
| 2219 | EMDB-MUSEUM (ZONE-3 + ZONE-4): |
| 2220 | LT Panel enclosure having space for 1No. Incomer MCCB 400Amp. and 10Nos. outgoing MCCB\"s40amp. to 160amp. according to the requirement at site (Approx. size 2025 x 1800 x 400mm) |
| 2221 | ESDB- COOLLONADE & MDB-MUSEUM (ZONE-3 + ZONE-4): |
| 2222 | LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCB\"s40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm) |
| 2223 | SDB-MUSEUM, SDB-ZONE-4 (TOWER) & SDB- COOLLONADE: |
| 2224 | LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB\"s40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm) |
| 2225 | MCCB\"s (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevantPWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc. |
| 2226 | MCCB Four Pole 250amp., 415volts, =36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 2227 | MCCB Four Pole 160amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2228 | MCCB Four Pole 100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2229 | MCCB Four Pole 63amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2230 | MCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2231 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s: Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB\"s as incomer and outgoings SP/TPminiature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 2232 | SDB- PRESSURIZATION: |
| 2233 | TP&NDouble Door Vertical DB\"s 4 way each (With provision of FP MCCB upto 125amp) |
| 2234 | ESDB-MUSEUM & ESDB- ZONE-4 (TOWER): |
| 2235 | TP&NDouble Door Vertical DB\"s 8 way each (With provision of FP MCCB 160amp.) |
| 2236 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 2237 | MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2238 | MCCB Four Pole 160amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2239 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 2240 | MCB Triple Pole 40amp. (10kA, Curve-C) |
| 2241 | MCB Triple Pole 50, 63amp. (10kA, Curve-C) |
| 2242 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 2243 | TP&N Vertical Double Door Distribution Board 8 way each. |
| 2244 | TP&NVertical Double Door Distribution Board 12 way each |
| 2245 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 2246 | Cable End Box for TPN Vertical 4/8/12Way |
| 2247 | MCB\"S & MCB DISTRIBUTION BOARDS: |
| 2248 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 2249 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 2250 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 2251 | RCCB\"s:Supply and erection of RCCB (Residual Current Circuit Breaker) for Earth leakage protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kAas per IEC 61008-1 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 2252 | RCCB Double Pole 32/40amp., Sensitivity 100mA |
| 2253 | CABLES & SUBMAIN WIRING: |
| 2254 | XLPE INSULATED ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 2255 | Overall size 10sq.mm (4Core) Armoured (On-Surface) |
| 2256 | Overall size 16sq.mm (4Core) Armoured (On-Surface) |
| 2257 | Overall size 95sq.mm (3½ Core) Armoured (On-Surface) |
| 2258 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 2259 | Aluminium thimble cable Core size 10 -16sq.mm |
| 2260 | Aluminium thimble cable Core size 50sq.mm |
| 2261 | Aluminium thimble cable Core size 95sq.mm |
| 2262 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections |
| 2263 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 10sq.mm |
| 2264 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 16sq.mm |
| 2265 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 95-120sq.mm |
| 2266 | CABLE TRAY: |
| 2267 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 2268 | Cable Tray Size 150mm x 50mm x 50mm (2mm thick) |
| 2269 | COPPER EARTHING (Upto 8 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc.,up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 2270 | Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) |
| 2271 | COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 2272 | Additional Length 20mm x 3mm thick Copper Tape |
| 2273 | LIGHT FIXTURES AND FANS: |
| 2274 | Supply and erection of LED batten 20watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Philips BN02IC LED20S PSU CW GRS2, Havell\"s ENDURALINEARNEOBS20WLED865SPCWH,Crompton CCS-103-20-65-SL-DP-NWH, Wipro LL20-281-XXX-65 ALI, Panasonic PBTM08208, Bajaj BCLAB 20W WH LED P |
| 2275 | S/E of LED 18 watt surface mounted downlighter (including LED driver) with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Crompton Cat No.LCDSPLN-R-18CDL, WIPRO Cat No. LD80-171-XXX-60-SM, Bajaj Cat No-BZSLOS NXT 18L LED WH SD |
| 2276 | S/E ofSurface LED1\"x4\" 31-40Watt Panel Ceiling light with high performance, commercial grade full diffuser providing uniform light with efficacy of LED fixture 100 lumens per watt (Minimum) and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % including erection, connections (With PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete) & testing etc complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Crompton Cat No. LCTLSNE-40-TL(1x4) Model SPAN/ WIPRO - Cat No. CRCO13S038HP57G1 Model Aura Plus/ Bajaj Cat No-BZSSLL36W LED WH Model-SKYLUX LED or its equivalent cat. and model of approved make. |
| 2277 | Supply and erection of LED batten 10watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Wipro Cat. No.LL20-111-XXX-65NE3, Bajaj Cat No.BCLSB10NW, Crompton Cat. No.CCS-103-10-65-SL-DP-NWH |
| 2278 | S/E of LED 12 watt recessed mounted downlighter (including LED driver) with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Crompton Cat No.CDR-205-12-57-SL-NWH, WIPRO Cat No. LD90-141-XXX-65-XX, Bajaj Cat No-BZSLO NXT 12L LED WH SD |
| 2279 | Supply and erection ofLEDBulk Head 9/10 wattIP65 surface mounted, pressure die cast housing complete in all respects as approved. and desired by the Engineer in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATBP/20/GL Dated 30/11/2017Make:-CROMPTON Cat No. LBHE10CDL, Philips Cat. No.WT202W LED6S NW PSU S2 PC,WIPPRO Cat. No. LW07-141-XXX-57-XX, Bajaj Cat. No. BIBWP 10W LED. |
| 2280 | S/E of 1x10 watt wall mounted LED fixture complete with lamp, ballast and all accessories as required with complete satisfaction of Engineer-in-charge Make: PHILIPS, Cat. No.(DUO-1, Model No.58152) or equivalent. |
| 2281 | S/E ofSurface LED1\"x4\" 31-40Watt Panel Ceiling light with high performance, commercial grade full diffuser providing uniform light with efficacy of LED fixture 100 lumens per watt (Minimum) and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % including erection, connections (With PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete) & testing etc complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Crompton Cat No. LCTLSNE-40-TL(1x4) Model SPAN/ WIPRO - Cat No. CRCO13S038HP57G1 Model Aura Plus/ Bajaj Cat No-BZSSLL36W LED WH Model-SKYLUX LED or its equivalent cat. and model of approved make. |
| 2282 | S/E of surface mounted30-35W LED spot light fixture complete with all accessories as requried at site. Make: Crompton Cat. No.CDS-200-30-40-SL-NWH, Wipro Cat. No.LD30-301-36W-40-PL, Havell\"s Cat. No.CYLINDROPROSURFDLS35WLED840S45DWHT |
| 2283 | S/E of 1 Metre of Track light system of 3 wire move up of CRCA, powder coated complete with end caps and suspention sytem as required at site. Make: Havell\"s Cat. No.1MTR3PHASETRACKTSWHT, WIPRO Cat. No.XTS5100 or its equivalent |
| 2284 | S/E of 2 Metre of Track light system of 3 wire move up of CRCA, powder coated complete with end caps and suspention sytem as required at site. Make: Havell\"s Cat. No.2MTR3PHASETRACKTSWHT, WIPRO Cat. No.XTS5200 or its equivalent |
| 2285 | S/E of Track mounted 35-41W Spot light fixture complete with lamp, ballast and all accessories as required at site. Make: WIPRO Cat. No. LD57-501-024-40-XX, Havell\"s Cat. No. CYLINDROTS35WLED80S3WIRE38DWHT or its equivalent |
| 2286 | S/E of M S powder coated & glass finsihed 5 x 9 W Surface mounted cluster light fixture with 9W LED Lamp and all accessories as required with complete satisfaction of Engineer-in-charge.Decon Cata. Ref. 03RN. or its equivalent |
| 2287 | SUPPLY AND ERECTION OF WIRING ACCESSORIES: |
| 2288 | Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,:- |
| 2289 | Bakelite Batten Holder (Large size) |
| 2290 | Supply and erection of Ceiling Fan 1200mm (48\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High SpeedOpel White, Orient- New Breeze, Havell\"s Velocity HS or equivalent. |
| 2291 | Supply and erection of Ceiling Fan 1400mm (48\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High SpeedOpel White, Orient- New Breeze, Havell\"s Velocity HS or equivalent. |
| 2292 | TELEPHONE & EPABX SYSTEM: |
| 2293 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 2294 | Wiring Telephone socket point RJ11 (one module) |
| 2295 | Supply & erection of20 Pair 0.5mm jelly filled Armored cable manufactured as per ITD specification with up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton, Finolex, RR kabel, Polycab, Shalimar. |
| 2296 | Supply and erection of 10 pairs MDF with krone modules & lockable box complete in all respect as desired by the engineer in charge at site. Make: Krone, M-Tel, Reliance, A-Tel, Airtele |
| 2297 | SARAI BUILDING (ZONE-5) GROUND FLOOR: |
| 2298 | POINT & SUBMAIN WIRING: |
| 2299 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 2300 | Wiring fan point with sheet metal fan box |
| 2301 | Wiring light point |
| 2302 | Wiring call-bell point |
| 2303 | Wiring 3 pin 6 Amp. wall socket point |
| 2304 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket point |
| 2305 | Wiring 3 pin 16/20 amp. power plug control point |
| 2306 | COPPER WIRES & CONDUIT PIPE: |
| 2307 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 2308 | Overall size 1sq.mm (Un-sheathed) |
| 2309 | Overall size 1.5sq.mm (Un-sheathed) |
| 2310 | Overall size 2.5sq.mm (Un-sheathed) |
| 2311 | Overall size 4sq.mm (Un-sheathed) |
| 2312 | Overall size 6sq.mm (Un-sheathed) |
| 2313 | Overall size 10sq.mm (Un-sheathed) |
| 2314 | Overall size 16sq.mm (Un-sheathed) |
| 2315 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 2316 | Heavy Gauge PVC Conduit Pipe 20mm dia. (Flushed) |
| 2317 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 2318 | Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) |
| 2319 | Heavy Gauge PVC Conduit Pipe 20mm dia. (On-surface) |
| 2320 | Heavy Gauge PVC Conduit Pipe 25mm dia. (On-surface) |
| 2321 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 2322 | PVC flexible pipe 40mm dia. |
| 2323 | Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:- |
| 2324 | PVC compression Socket gland 40mm dia. |
| 2325 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Casing \"n\" Capping (Double Lock) ISI markedfor wiring purposes including cost of bends (L), (U), (T) & inspection boxes etc., where necessary including other petty material:- |
| 2326 | PVC Casing \"n\" Capping Size 20mm x 12mm |
| 2327 | PVC Casing \"n\" Capping Size 25mm x 16mm |
| 2328 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):- |
| 2329 | Powder Coated Concealed Metal Box with Brass Lugs One/Two Module |
| 2330 | Powder Coated Concealed Metal Box with Brass Lugs Three Module |
| 2331 | Powder Coated Concealed Metal Box with Brass Lugs four Module |
| 2332 | Powder Coated Concealed Metal Box with Brass Lugs Six Module |
| 2333 | Powder Coated Concealed Metal Box with Brass Lugs Eight Module |
| 2334 | Powder Coated Concealed Metal Box with Brass Lugs Twelve Module |
| 2335 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 2336 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 2337 | MAIN /SUB DISTRIBUTION BOARDS & DISTRIBUTION BOARDS: |
| 2338 | ZONE- 5 |
| 2339 | LT PANELS & MCCB\"s (MOULDED CASE CIRCUIT BREAKERS):Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication: Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . |
| 2340 | Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB\"s. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following:- |
| 2341 | MDB- SARAI BUILDING: |
| 2342 | LT Panel enclosure having space for 1No. Incomer MCCB 400Amp. and 10Nos. outgoing MCCB\"s40amp. to 160amp. according to the requirement at site (Approx. size 2025 x 1800 x 400mm) |
| 2343 | MCCB\"s (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevantPWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc. |
| 2344 | MCCB Four Pole 400amp., 415volts, =36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 2345 | MCCB Four Pole 100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2346 | MCCB Four Pole 63amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2347 | MCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2348 | EMDB- SARAI BUILDING: |
| 2349 | Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP44).Fabrication: Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS:8623. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The base channel will be made out of 75mm x 40mm x 5mm rolled channel. \"The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. |
| 2350 | Painting:The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work. Busbars: The panel shall be provided with TPN copper busbar of suitable size according to the size of MCCB\"s.All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard). The Concerned contactor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of ACB/MCCB\"s to be installed in the cubical panel Enclosure (including the cost of MCCB\"s+E.R.H.) as per following. |
| 2351 | Incomer:¦ MCCB 400A, 415V breaking capacity =36kA 4P microprocessor based adjustable thermal and magnetic protection= 1No.Outgoings: ¦ MCCB 250A, 415V breaking capacity =36kA 4P microprocessor based adjustable thermal and magnetic protection= 3Nos.¦ MCCB 200A, 415V breaking capacity =36kA 4P microprocessor based adjustable thermal and magnetic protection= 4Nos.¦ MCCB 100amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 3Nos.¦ MCCB 40amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 9Nos.¦All Incomers & Out going With Extendable Rotary Handle with adjustable depth complete as per schematic diagram attached & Satisfaction of the Engineer in charge at site.Enclosure:Panel Size: As per NormsPanel builders Make: Kalyani Switchgear, ETE Electrogears, Power Associates, Unix, CMKL |
| 2352 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 2353 | TP&N Vertical Double Door Distribution Board 8 way each. |
| 2354 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 2355 | Cable End Box for TPN Vertical 4/8/12Way |
| 2356 | MCB\"S & MCB DISTRIBUTION BOARDS: |
| 2357 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 2358 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 2359 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 2360 | RCCB\"s:Supply and erection of RCCB (Residual Current Circuit Breaker) for Earth leakage protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kAas per IEC 61008-1 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 2361 | RCCB Double Pole 32/40amp., Sensitivity 100mA |
| 2362 | CABLES & SUBMAIN WIRING: |
| 2363 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 2364 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 2365 | Heavy Gauge PVC Conduit Pipe 50mm dia. (Flushed) |
| 2366 | CABLE TRAY: |
| 2367 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 2368 | Cable Tray Size 150mm x 50mm x 50mm (2mm thick) |
| 2369 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 2370 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 2371 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 2372 | Double walled corrugated (DWC) HDPE pipe 90/76mm (outer/ inner dia.) |
| 2373 | Double walled corrugated (DWC) HDPE pipe160/136mm (outer/ inner dia.) |
| 2374 | EARTHING SYSTEM: |
| 2375 | G.I. EARTHING:Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 2376 | Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length) |
| 2377 | COPPER EARTHING (Upto 8 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc.,up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 2378 | Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) |
| 2379 | COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 2380 | Additional Length 20mm x 3mm thick Copper Tape |
| 2381 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc. |
| 2382 | Additional length G.I. rope 7/14 S.W.G. (7/2.18mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 2383 | LIGHT FIXTURES AND FANS: |
| 2384 | Supply and erection of LED batten 20watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Philips BN02IC LED20S PSU CW GRS2, Havell\"s ENDURALINEARNEOBS20WLED865SPCWH,Crompton CCS-103-20-65-SL-DP-NWH, Wipro LL20-281-XXX-65 ALI, Panasonic PBTM08208, Bajaj BCLAB 20W WH LED P |
| 2385 | S/E of LED 18 watt surface mounted downlighter (including LED driver) with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Crompton Cat No.LCDSPLN-R-18CDL, WIPRO Cat No. LD80-171-XXX-60-SM, Bajaj Cat No-BZSLOS NXT 18L LED WH SD |
| 2386 | S/E ofSurface LED1\"x4\" 31-40Watt Panel Ceiling light with high performance, commercial grade full diffuser providing uniform light with efficacy of LED fixture 100 lumens per watt (Minimum) and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % including erection, connections (With PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete) & testing etc complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Crompton Cat No. LCTLSNE-40-TL(1x4) Model SPAN/ WIPRO - Cat No. CRCO13S038HP57G1 Model Aura Plus/ Bajaj Cat No-BZSSLL36W LED WH Model-SKYLUX LED or its equivalent cat. and model of approved make. |
| 2387 | Supply and erection of LED batten 10watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Wipro Cat. No.LL20-111-XXX-65NE3, Bajaj Cat No.BCLSB10NW, Crompton Cat. No.CCS-103-10-65-SL-DP-NWH |
| 2388 | S/E of LED 12 watt recessed mounted downlighter (including LED driver) with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Crompton Cat No.CDR-205-12-57-SL-NWH, WIPRO Cat No. LD90-141-XXX-65-XX, Bajaj Cat No-BZSLO NXT 12L LED WH SD |
| 2389 | Supply and erection ofLEDBulk Head 9/10 wattIP65 surface mounted, pressure die cast housing complete in all respects as approved. and desired by the Engineer in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATBP/20/GL Dated 30/11/2017Make:-CROMPTON Cat No. LBHE10CDL, Philips Cat. No.WT202W LED6S NW PSU S2 PC,WIPRO Cat. No. LW07-141-XXX-57-XX, Bajaj Cat. No. BIBWP 10W LED. |
| 2390 | Supply and erection of Surface mounted 36watt LED panel(including LED driver) with CRCA sheet having efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Make:-Philips SM366C LED32-6500 PSU OD WH, CROMPTON Cat. No.LCTLSNE-36-FO-CDL (2X2), WIPRO Cat. No. CRCO10S038HP57GL1 |
| 2391 | SUPPLY AND ERECTION OF WIRING ACCESSORIES: |
| 2392 | Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,:- |
| 2393 | Bakelite Batten Holder (Large size) |
| 2394 | Supply and erection of Ceiling Fan 900mm (36\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High SpeedOpel White, Orient- New Breeze, Havell\"s Velocity HS |
| 2395 | Supply and erection of Ceiling Fan 1200mm (48\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High SpeedOpel White, Orient- New Breeze, Havell\"s Velocity HS or equivalent. |
| 2396 | Supply and erection of Heavy duty Exhaust Fans 300mm, 900RPM with aluminium louver shutter, double ball bearinglonger life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make: Crompton EXHD300-6-1, Havells Turbo Force SP, Orient (Heavy Duty) |
| 2397 | TELEPHONE & EPABX SYSTEM: |
| 2398 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 2399 | Wiring Telephone socket point RJ11 (one module) |
| 2400 | Supply & erection of20 Pair 0.5mm jelly filled Armored cable manufactured as per ITD specification with up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton, Finolex, RR kabel, Polycab, Shalimar. |
| 2401 | Supply and erection of 30 pairs MDF with krone modules & lockable box complete in all respect as desired by the engineer in charge at site. Make: Krone, M-Tel, Reliance, A-Tel, Airtele |
| 2402 | PROVIDING ADDRESSABLE FIRE DETECTION & FIRE ALARM SYSTEM: |
| 2403 | FIRE PANELS & ANNUNCIATORS: |
| 2404 | Supply,installation, testing & Commissioning of Minimum 2 loopUpgradable to 10 loops Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition.Designed to meet UL864, 10th Edition & FM Approved complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Notifier by Honeywell, Bosch UL, Fire Finder by Siemens |
| 2405 | Supply,installation, testing & Commissioning of Minimum 1 loop Microprocessor based, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition.Designed to meet UL864, 10th Edition & FM Approved complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Notifier by Honeywell, Bosch UL, Fire Finder by Siemens |
| 2406 | Supply, Installation, Testing & Commissioning of Amplifier 500W, Rated power output (sin.) 2 x 250 W, Voltage consumption (230 V AC) 2.8 A, (24 V DC / Sinus continuous tone*) 25 A, (24 V DC / Announcement / 1/3 load) * 8.75 A (24 V DC / Announcement / 1/8 load) * 3.6 A, Power consumption in standby mode (230 V), separated f. mains supply A`pprox. 0 VA, Rated power output (sin.) 2 X 400 W Voltage consumption (230 V AC) 4.5 A, (24 V DC / Sinus continuous tone*) 40.5 A (24 V DC / Announcement / 1/3 load) *13.9 A, (24 V DC / Announcement / 1/8 load) *5.6 A, Power consumption in standby mode (230 V), separated f. mains supply Approx. 0 VA, Nominal voltage 230 V AC, Nominal frequency 50 to 60 Hz, +10% / -5% Emergency power supply 24 V DC, Functional principle Class D, Transmission frequency band (-1 dB) 50 Hz to 22 kHz, Signal-to-noise ratio > 90 dB, A - unweighted Harmonic distortion at full load / 1 kHz < 0.03 %, Channel separation > 42 dB Input impedance 20 kO, el. balanced Specification 20 kO, el. balanced, Height, Width, Depth: 88mm, 402 mm / 2 HU, 19”mm, 483mm,Weight D250 approx. 16.5 kg, D400 approx. 19 kg. Makes : Honeywell, Johnson Control ( ifc series) |
| 2407 | Supply, Installing, testing and commissioning of same OEM make Cloud based service through universal gateway, which shall be enabled through internet. Remote health monitoring solution shall utilize cloud based software-as-a-service web application & supplementary network gateway hardware for all panels. System shall provide secure web access to cloud based web application using any of the web browsers like Google Chrome (preferable), Internet Explorer etc. from any computer/ tablet/ smartphone connected over internet via defined credentials – username and password. It shall also have the facility to monitor the cloud service over the mobile apps. The cloud based web application shall capture all fire alarm system data points as received from the system via supplementary gateway hardware of the same make as Fire Alarm Panel. The software shall display real time view of fire system effectiveness, multi-location unified view, custom dashboard, device level information, scheduled reporting, e-mail of critical alarms. The cloud service shall be capable of monitoring 250000 datapoints scattered accross multiple install bases spread accross multiple geographical locations. Make: Notifier by Honeywell, Bosch UL, Johnson Control ( IFC Series) |
| 2408 | DETECTORS: |
| 2409 | Supply, installation, testing & Commissioning of Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 4.0% obs/ft. The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photo electric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Designed to meet UL268, 7th Edition with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Notifier by Honeywell ( FSP/951T+B501/White),Fire Finder by Siemens,Bosch UL |
| 2410 | Supply,installation ,testing & Commissioning of Reponse Indicator for up side of ceiling complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Notifier by Honeywell ( FSP/951T+B501/White),Fire Finder by Siemens,Bosch UL |
| 2411 | Supply,installation ,testing & Commissioning of Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches including cost of petty material required to complete the work complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Notifier by Honeywell (FST/951R+B501/White),Fire Finder by Siemens,Bosch UL |
| 2412 | Supply,installation ,testing & Commissioning of Addressable Duct Smoke Detector. The duct detector shall have an air velocity rating from 100 to 4000 ft/min. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches including cost of petty material required to complete the work complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Notifier by Honeywell (DNR+FSP/951+DST1.5),Fire Finder by Siemens,Bosch UL |
| 2413 | Supply, installation, testing & Commissioning of Addressable High Sensitivity early warning Photo Detector with sensitivity level of 0.02% to 2% Obs/Feet. The detector shall have the optic block to amplify signals from smoke, but diminish stray internal reflections that can cause false alarms. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Designed to meet UL268, 7th Edition.Make: Notifier by Honeywell / XLS 3000 / Bosch UL/ Johnson Control ( IFC Series) complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Notifier by Honeywell, Vighanharta,Fire Finder by Siemens,Bosch UL |
| 2414 | MODULES: |
| 2415 | Supply, erection, testing & commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device including cost of petty material required to complete the work complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Notifier by Honeywell (F/MCP/GLASS), Fire Finder by Siemens,Bosch UL |
| 2416 | Supply, installation, testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes/ Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Notifier by Honeywell FCM/1,Fire Finder by Siemens,Bosch UL |
| 2417 | Supply, installation, testing & Commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete in all respects as approved and desired by the Engineer-in-charge at site. Make:Honeywell FRM/1,Fire Finder by Siemens,Bosch UL |
| 2418 | Supply, installation, testing & Commissioning of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Honeywell FMM/1, Fire Finder by Siemens,Bosch UL |
| 2419 | Supply, installation, testing and commissioning Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Notifier by Honeywell ISO/X,Fire Finder by Siemens,Bosch UL |
| 2420 | NOTIFICATION DEVICES: |
| 2421 | Supply, installation, testing & Commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication UL Listed complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Notifier by Honeywell SYS/HS, Fire Finder by Siemens,Bosch UL |
| 2422 | PUBLIC ADDRESS DEVICES: |
| 2423 | Supplying, installing, testing and commissioning of Box Speaker wall mounted, Rated power 6 W, 100 V line transformer, Technical Specification,Transformer power 3W -6W, Sensitivity 88 dB, SPL 1m/6 W 96 dB, Frequency response (-10 dB) 110 Hz ~13K Hz, Dimensions 260 x 180 x 120 mm, Weight 1.08 Kg, Material ABS, Color RAL 9003. Make:Honeywell, Bosch Praesideo, Johnson Control ( IFC Series) |
| 2424 | Supply, erection, testing & commissioning of 1KVA onlinesine wave UPS/ Power plant with in built SMF batteries having 30 minutes backup time complete in all respects as approved and desired by the Engineer-in-charge at site. Make: APC, Numeric, Uniline, Eaton, Aqua Power. |
| 2425 | CONDUIT & CABLES: |
| 2426 | Supply, installation, testing & Commissioning of fire resistance cable (Colour Red) (at 950° C for 180 minutes) of BS6387/BS7846 Fire Proof Cable, 2C X 1.5 sqmm, BS6387 & BS7846, annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke & zero halogen (LSZH) bedding, galvanized steel wire armour, low smoke & zero halogen (LSZH) red outer sheath. 600/1000 volts. Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3) complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton, Havell\"s, Rallison, Fusion, Polymair |
| 2427 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 2428 | Heavy gauge welded conduit pipe 25mm dia. (ISI marked 1.60mm thick) Flushed |
| 2429 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 2430 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 2431 | PVC CHANNEL (uPVC TRUNKING):Supply and erection ofPVC Channel (uPVC Trunking) with cover of various sizes (On Surface) on wall, Flat angle, internal & external angle, Flat Tee, End cap and mounting boxes including the cost of joint cover, fixing and other petty material etc.:- |
| 2432 | PVC Channel (uPVC Trunking) 50mm x 50mm |
| 2433 | End Cap50mm x 50mm |
| 2434 | PROVIDING CCTV ALONG WITH ALLIED ACCESSORIES: |
| 2435 | SITC of IP indoor Camera1/2.8\" SONY Starvis Back-illuminated CMOS Sensor 2 MP ,2.7-13.5mm Motor Zoom Auto Focus Lens ,AF,WDR; Super Starlight With Internal POE Main Stream: 1080P@30fps, 3M@15fps; 3MP HD Lens, With IR-CUT 2.7-13.5mm Motor Zoom Auto Focus Lens HDR, Defog, Flicker Control,2D DNR,3D DNR,Back Light control, Motion Deduction, Privacy Masking 3 Rectangular Zone, CompressionH.264/H.264+/ H.265/ H.265+/ JPEG/ AVI / MJPEG, Electronic Shutter Time Auto: PAL 1/25-1/10000Sec; NTSC 1/25-1/10000 Sec, Protocol:TCP/IP, ICMP, HTTP, HTTPS,FTP, DHCP , DNS, DDNS, RTP, RTSP,RTCP,NTP, SMTP, ONVIF 2.4, Camera makes Sony / Mobiteh, Mountxross, Bosch, Axis/Pelco should be compatable with same make of NVR. IE Brower IE8-11, Google Chrome, Firefox, Safari, Mac Safari, Smart PhoneiPhone, iPad, Android, Android Pad, Image ConfigSaturation/ Brightness/ Contrast /Sharpness, Mirror, 3D NR , White Balance, FLK(Flicker Control)Main Stream: 1080P/720P@30fps; 3MP HD Lens, With IR-CUT/(H.264/H.265) , IR range: 30M , Recording Mode NVR/NAS/CMS/Web completeApproved Make : Sony, Mobiteh, Bosch, Axis, Pelco |
| 2436 | SITC of 5MP Face Detection IP Network CameraOutdoor IP66 5X AF IR 60m, Face Detection and Recognition(max support 5000 faces) detection distance 12M, • 1/2.8\"SONY Starvis Back-illuminated CMOS sensor • H.264 /H.264 +/H.265 /H.265+ Compression Method • Lens: 2.7-13.5 [email protected] Motorized, Autofocus; 5MP HD Lens • IR Distance 40m Max.S/N Ratio=52dB,• IP66 Outdoor Metal Case,Infrared LED42µ x 4PCS,Infrared Distance 40M, Minimun Illumination 0.01Lux,ProtocolTCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, SMTP, ONVIF 2.4,Camera makes Sony / Mobiteh, Mountxross, Bosch, Axis/Pelco should be compatable with same make of NVR .Intelligent AnalysisIntrusion Detetion, Line Cross Detetion, Loiter Detetion, People Gather Detecion,DefogMode, ROI, BLC, Motion Detection, PrivacyMasking3 Rectangular Zone, Operation Temperature-20? ~ +60? RH95% Max Make : Sony, Mobiteh,Bosch, Axis, Pelco |
| 2437 | SITC of 5 MP IP PTZ camera 1/2.8\" SONY Starvis Back-illuminated CMOS Sensor Horizontal Resolution5MP, Compression H.264/H265, S/N Ratio>50db, PTZHorizontal Rotation Speed 45°/S, Horizontal Rotation Range 0°~360°, Tilt Rotation Speed 30°/s, Tilt Rotation Range 0°~93°, Preset Points 220, Guard Tours3 groups, Guard PointsMax.16 points, Lens, Focus Length3.9mm-85.5mm, Focus Control22X Optical Zoom, Night Vision, Infrared LED?42x6PCS, IR Range120m, Day-night modeAUTO, Smart image control, Licence reading plate mode, faceless explosure mode, WDR BLC, flicker control, privacy zone, motion detection, face detection,Network, Network protocolTCP/IP, HTTP, FTP, RTSP, UPnP, DNS, NTP, RTP, UDP, IGMP,P2P, ONVIFSupport, Network interfaceBuilt-in RJ45 network interface,support 10M/100M IP DATA, Main Stream12560*1920@20fps, Main Stream22560*1440@25fps, Main Stream32304*1296@25fps, Main Stream41920*1080@25fps, Main Stream51280*720@25fps, Main Stream6640*512@25fps, Sub Stream1800*448@25fps, Sub Stream2704*576@25fps, Sub Stream3640*360@25fps, Sub Stream4352*288@25fps, Alarm/, SD Card Slot/, WeatherproofIP66, Operating TemperatureIndoor: 0°~ +40° Outdoor:-40°~ +60°, Operating Humidity =90% Non Condensing, PowerDC12V 2A/3A, Lightning ProtectionTransient voltage 6000V. Approved Make : Sony, Mobiteh,Bosch, Axis, Pelco |
| 2438 | GI PIPE POLES: (FOR INSTALLATION OF PTZ CAMERAS)Supply and erection of G.I. pipe ‘A’ quality of suitable length and dia. confirming to IS:1239 (Part-I) 1979, including fixing up to a given depth below G/L, the hole of excavation about 30cm dia. and given depth to be filled in up to 15cm below G/Lwith 1:2:4 cement concrete including painting of pole with two coats of approved aluminiumpaint as required:- |
| 2439 | G.I. Pipe Pole 6.1 metre Long, Dia. 100mm, Planting Depth 120cm with Pit Depth 135cm. |
| 2440 | SITC of PoE Spliliter12 v 1 Amp, IP66 For High Voltage Protection complete in all respects as approved and desired by the Engineer in-charge at site. Make : Honeywell,Mountxross, Bosch, Axis/Pelco |
| 2441 | SITC of Power supply 12Volt 3 amp for PTZ complete in all respects as approved and desired by the Engineer in-charge at site.Make : Honeywell, Bosch, Axis/Pelco |
| 2442 | SITC of 64CH NVR with(4096×2160, 2592x1944, 2048x1536, 1920×1080, 1280×960, 1280×720, etc),1 VGA, 2 HDMI, Input1 Port RCA,Audio Bit Rate64kbps,Audio Compression standardG.711,Sensor Input-16,NVR should support Output Intelligent AnalysisIntrusion Detetion, Line Cross Detetion, Loiter Detetion, People Gather Detecion,DefogMode, ROI, BLC, Motion Detection, PrivacyMasking3 Rectangular Zone4, Motion Detection 64 Channel, MD Zones: 396 (22 × 18),Trigger EventsRecording, Email, FTP, Snapshot, Buzzer and Screen Tips, alarm output,HDMI14K (3840 × 2160)/60Hz, 4K (3840 × 2160)/30Hz, 1920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 × 768/60Hz, HDMI21920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 × 768/60Hz ,VGA1920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 × 768/60Hz,Display Split 4CHxD1/ 36CHxD1/ 25CHxD1/ 16CHxD1/ 9CHxD1/4CHxD1/1CHx1080P/ 1CHx3MP/ 1CHx4MP/1CHx5MP/1CHx4k,Digital ZoomYES,OSDCamera Title, Time, Recording, Motion Detection,Video CompressionH.264/H.265, Resolution 4k(4096×2160), 5MP(2592×1944), 4MP(2688×1520), 3MP(2048×1536), 1080P(1920×1080), 960P(1280x960), 720P(1280×720), D1 (720×576/720×480) RecordRatePAL:4k@ 30×25fp,5MP @ 50×25fp, 4MP@64x25fp, 3MP @ 64×25 fp, 1080P@64×25fp, 960P@64×25fp,720P@64×25fp, D1@64×25fp NTSC:4k @30×30fp, 5MP@ 50×30fp,4MP@64×30fp,3MP@64×30fp,1080P@64×30fp, 960P@64×30fp, 720P@ 64×30fp, D1@ 64×30 fp Record ModeManual\Timer\Motion Detection,Local Sync Playback4CH 4K@30fps, 6CH 5MP@ 30fps, 8CH 4MP@30fps, 10CH 3M@30fps, 16CH 1080P@30fps, 16CH 960P@30fps, 16CHP@ 30fps, Decode Capability4CH 4K(3840×2160)@30fps, NVR Make :Sony/Mobiteh,Mountxross, Bosch, Axis/Pelcoshould support IP camera Make Sony/Mobiteh,Mountxross, Bosch, Axis/Pelco. Remote Sync Playback Search ModeALL, Channel, Manual, Time, Date, Motion Detection,,Playback FunctionsPlay, Pause, Stop,Fast Play, Digital Zoom Backup ModeUSB Device/Network,Interface2 RJ-45 10/100/1000Mbps self-adaptive Ethernet interfaces Incoming Bandwidth300MB,Network FunctionsTCP/CP, HTTP, UPnP, DNS, NTP, SMTP, PPPoE, DHCP, FTP, DDNS, RTP, RTSP, RTCP Make Sony, Mobiteh, Bosch, Axis, Pelco |
| 2443 | SITC of Display Information sytem working on LAN ,55\" 4K , UHD, Digital Signage,4000;1DVI-D,DP1.2,HDMIX2, HDCP2.2, Stereo mini Jack,USBX2, RS232C(in/out),RJ45, 300NITS, MagicInfo Premium software, Multi Display Control Software, WI-FI,Auto Source recovery & switching, 8Gb with StandMemory. Make Samsung, Sony, LG, Toshiba, Hitachi |
| 2444 | SITC of L2+ Managed Industrial Grade POE Switch 12 Ports Gigabit Managed Industrial Grade POE Switch , 8 10/100/1000 Base- TX portand 2 Gigabit SFP slotand 1console port Network Protocols: Support , IEEE802.3, IEEE802.3u, IEEE802.3z , IEEE802.3ab , IEEE802.3x , IEEE802.1d , IEEE802.1w , support IP camera All Make. Netgear, Cisco. Mountxross, D link,should Working temperature:-40~75? Storage temperature:-40~85?, Relative Humidity : 5%~95% (no condensation), Shell : IP30 protectgrade, metal shell Installation : DIN- Railor Wallmounts, MTBF : 300,000 hours , Support L2+ Switching features including 802.1Q VLAN, Mirroring, Portisolation, IGMP Snooping, DHCP Snooping, LLDP, IP Source Guard, ARP inspection, ACL setc. Support spanning tree STP(802.1D) and RSTP(802.1W).802.1s(MSTP) way exchange time< 50ms Jumbo frames support upto 9.6 Kkilobytes Support enhanced managemen through WEB,CLI, TELNET, SSH, SNMP Ethernet portsupport 10/100/1000 Mself-adaption.Bandwidth: 24Gbps, Packet Buffer Memory: 4M Packet Forwarding Rate:1488000 pps /port Address Table : 8K. Make: Netgear, Cisco, Mountxross, Allied telesis |
| 2445 | SITC of 24 port POE switch IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, 802.3ae 10 GbE, IEEE 802.3x Flow Control for Full-Duplex Mode, Auto-negotiation,24 10/100/1000 Mbps PoE capable, 2 Gigabit SFP, 2 10GSFP+,Full/half duplex for 10/100 Mbps and Gigabit speed,Auto or configurable MDI/MDIX,Switching Capacity 92 Gbps,Transmission Method Store-and-forward,MAC Address Table 16,000 entries per device,Maximum 64 bytes PacketForwarding Rate 68.45 Mpps,PoE Standard IEEE 802.3af, 802.3at,Ports 1 to 24: Up to 30 W,PoE Power Budget Max. 193 W,Heat Dissipation 813.967 BTU/hr,Diagnostic LEDs Power/Stacking ID/Fan (per device), Link/Activity/Speed (per 10/100/1000 Mbps port), Link/ Activity/Speed (per Gigabit SFP port), Link/Activity/Speed (per 10G SFP+ port),L3 Features ARP• 256 Static ARP• Supports Gratuitous ARP• IPv6 Neighbour Discovery (ND)• Default Routing• Static Routing• 64 IPv4 Static Route Entries• 32 IPv6 Static Route Entries,• CLI• Telnet Server• TFTP Client• IPv6 Neighbor Discovery• Configurable MDI/MDIX• SNMP• Supports v1, v2c, v3• SNMP Trap• System Log• Max. 10,000 log entries• DHCP Client• D-Link Network Assistant support• SNTP• ICMPv6• IPv4/v6 Dual Stack• DHCP Auto Configuration• RMON v1 complete in all respects as approved and desired by the Engineer in-charge at site. Make Netgear, D-link |
| 2446 | SITC of 20 SFP ports• 4 Combo 10/100/1000BASE-T/SFP ports • 4 10 GbE SFP+ ports,Console Port • RJ45 and Mini USB console ports for out-of-band CLI management,Management Port • 10/100/1000BASE-T RJ-45 Ethernet for out-of-band IP management,• 1 RJ-45 port,1 USB 2.0 Type A port,Switching Capacity • 128 Gbps,Packet Forwarding Rate • 95.24 Mpps,Packet Buffer • 4 MBytes,MAC Address Table • 68K entries2,IPv4 Routing Table • 16K entries,IPv6 Routing Table • 7K entries,IPv4 Forwarding Table • 32K entries2,IPv6 Forwarding Table • 16K entries2,Jumbo Frame Size • 12 KBytes. Make: Cisco, D-Link, Extreme, Netgear |
| 2447 | SITC of Wall Mount 9U Rack ,Front Glass Door (tinted,Toughened) with Lock & Key,2 pairs of 19\" Mounting Rails with U-Marking,Welded Side Walls With Metal Logo,1U Cable Manager (1), Hardware Packet (1 Pkt),6 Socket 5 Amp. Power Distribution Unit (1 No),Roof Mounted Fan Unit / 90 CFM /230V AC (1 No) complete in all respects as approved and desired by the Engineer in-charge at site Make: DLink, Netrack |
| 2448 | SITC ofOutdoor Waterproof Pole Mount 9U Rack ,Front Door with Lock & Key,2 pairs of 19\" Mounting Rails with U-Marking,Welded Side Walls With Metal Logo,1U Cable Manager (1), Hardware Packet (1 Pkt),6 Socket 5 Amp. Power Distribution Unit (1 No), complete in all respects as approved and desired by the Engineer in-charge at site Make DLink/Netrack |
| 2449 | SITC of 27U Network Enclosure Frame-600X800-STEEL with accessories like fan, pdu, cable manager etc. SITC of 27U Enclosure Frame-800X1000-STEEL, Caster Wheels Set of 4 (2 with Brakes & 2 without Brakes),Adjustable Levellers set of 4, Glass Door-800-27U, Metal Door-800-27U-Vented, Side Panels-1000-27U-Vented, Mounting Hardware-(Pack of 20), FHU with 4 FAN 360CFM, Vertical Power Distribution Unit with 12 x 5/15 sockets Round Pin, 230 Volts AC, 32 Amp with Plug, Vertical Cable Manager-27U-Loop, Horz. Cable Manager-1U-Loop, Conforms to DIN 41494 OR equivalent ISO Standards, Adjustable 19” equipment mounting verticals provide the better mounting flexibility maximizing the usable mounting space, Depth adjustable mounting slots, Top and bottom Panel with ventilation and cable entry facility, Provision to mount the cooling fans on the top panel, Powder coated finish with pretreatment process meeting all industry standards, Grounding and Bonding Options can be provided, 100% assured compatibility with all equipment conforming to DIN 41494. General industrial standard for equipment, Conforms to DIN 41494 or equivalent standard, Welded Frame, Lockable Toughened Glass Door, Metal Vented Door Steel, DIN Standard 10mm Sq. Slots / Direct M6 Tap, 19” Mounting angles made of formed steel Powder Coated, Welded to Frame, Vented and Field Cable entry exit cut outs. Make: DLink, Netrack |
| 2450 | SITC of HDD Formatted capacity 6 TB,Data transfer rate (max) Buffer to host Host to/from drive (sustained) 6 Gb/s 171 MB/s,Cache (MB) 64,Rotational speed (RPM) IntelliPower ,Load/unload cycles4 300,000,Non-recoverable read errors per bits read <1 in 1014,Operating (2 ms, read/write) 30,Operating (2 ms, read)65, Non-operating (2 ms)250,Average power requirements (W) Read/Write 5.90,Idle 4.90,Standby and Sleep 0.40 complete in all respects as approved and desired by the Engineer in-charge at site. Make: WD, Toshiba |
| 2451 | SITC of Category 6 UTP, 4 Pair This cable well exceeds the requirements of TIA/EIA-568-C.2 and IEC/ISO 11801. Construction: 4 twisted pairs separated by cross separator, 4 channel, polymer spine / full separator. Half shall not be accepted. Cable should be Armoured. Operates at bandwidth of 250 MHz, Conductor Solid Bare Electronic Grade Copper. Inner jacket should be PVC and outer should be PE, suitable for direct burial. Insulation: Polyethylene, Attenuation (< 36 db/100m), Pair – to – pair and PS NEXT, ELFEXT and PSELFEXT, Return Loss, ACR and PS ACR., Nominal Outer Diameter of Cable should be 9.70 mm and Conductor Diameter 0.56 mm (23 AWG), Cable should support operating Temperature from -20° to +60°C, Cable should come with printed sequential Length Counter on each meter, Cable support Conductor Resistance 93.5 OHMS/1000MTR@20 Degree, Mutual Capacitance of cable should be < 5.6nF/100m, Max Resistance Unbalance of cable should be 5% Max, Capacitance Unbalance of cable should max 330pF/100m, Cable support Delay Skew: < 45nS, Operating Voltage: 72V and NVP: 69%, Shall Supports Gigabit Ethernet (1000 base-T) standard and Operates at bandwidth of 250MHz.complete in all respects as approved and desired by the Engineer in-charge at site. Make: D link, Molex |
| 2452 | Supply and laying of 6 Core Single Mode Optical Fiber Cable.The fiber type is a Matched Cladding Single Mode,Fiber dual coated with acrylate coating.The fiber is optimized for operation at 1310 nm and at 1550 nm.,Should fulfill the requirements of:IEC 793-2: 1992,EN 188101 andITU-T Recommendation G.652,Testing methods are in accordance with the following standards: ITU-T G.652.D, IEC 793-1 and Telecordia : GR-20 Core,ISO : 11801,Maximum induced permanent loss after 1000 h at 1 bar H2 at 70 °C and out gassing for 72 h at 70°C (valid both at 1310 nm and at 1550 nm): 0.2 dB/km .Manufacturer should have ISO 9001:2008 Certification for Quality Management System.Manufacturer should have ISO 14001:2004 Certification for Environmental Management System.All OFC and Components should be from same OEM. Make: Systemax, AMP, D-Link, R&M |
| 2453 | Supply, Installation, Testing and Commissioning of12 Port Rack Mount LIU loaded.LIU 12 PORT Rack Mount - Loaded (SC) SM,FIBER PATCH PANELS – RACK MOUNT Have sufficient slots accommodate Simplex/duplex SC adapters individually.Aluminum base material for light mounting,Should have Splice Tray & Cable Spoolprovision inside,Accessory kit consists of cable ties, mounting ear screw earthling and spiral wrap tube.Can Include 12SC Terminations ,Removable Rubber grommet to allow for pre-terminated fiber trunk installation,protect cable and minimize dust build up,Should have cable ties,mounting ear screws and spiral wrap tube. Make: Systemax, AMP, D-Link, R&M |
| 2454 | Supply, Installation, Testing and Commissioning of24 Port Rack Mount LIU loaded.LIU 12 PORT Rack Mount - Loaded (SC) SM,FIBER PATCH PANELS – RACK MOUNT Have sufficient slots accommodate Simplex/duplex SC adapters individually.Aluminum base material for light mounting,Should have Splice Tray & Cable Spoolprovision inside,Accessory kit consists of cable ties, mounting ear screw earthling and spiral wrap tube.Can Include 12SC Terminations ,Removable Rubber grommet to allow for pre-terminated fiber trunk installation,protect cable and minimize dust build up,Should have cable ties,mounting ear screws and spiral wrap tube. Make: Systemax, AMP, D-Link, R&M |
| 2455 | Supply, Installation, Testing and Commissioning ofLC-SC Single Mode Fiber Patch Cord - 2 Meter.PATCH CORD LC-SC SM DUPLEX,Optical Fiber Equipment Cords (minimum 2 meter) All optical fiber patch leads shall comprise of Single mode 9/125µm fiber with SC/LC/FC, fiber connectors terminated at each end. The optical fiber patch leads shall comply with the following specifications: Optical Fiber – Corning Single Mode,Connector: Zirconia ceramic ferrule,Pre-radiuses and pre-polished ferrule,Simplex / Duplex ,Color-codedYellow for SM ,Insertion Loss - <0.2 db,Cable:9/125, SM,Repeatability - < 0.2 db ,Durability – 1000 mating cycle ,Working Temp : -20 deg C.to + 65 deg. C,Standard : G652D, G 657A & G 657B. Make: Systemax, AMP, D-Link, R&M |
| 2456 | Supply, Installation, Testing and Commissioning of SC Pigtail, Simplex - Single Mode.PIGTAIL SC SM SIMPLEX LENGTH- 1m ,Pigtails Corning G652D, G657A, G657Bsingle-mode /Insertion Loss Typical:<0.2dB, Max. 0.3dB(MTRJ:Max. 0.5dB)/Return Loss PC>45dB, UPC>50 dB,APC>60dB /ConnectorFerrule Ceramic, (MTRJ: PS- Polyphenylene Sulphide )Apex Offset <50um / Fiber Height ±100nm , End-face Radius of Curvature 7mm < R < 25mm (Excluding MTRJ)/ Repeatability <0.2dB 1,000 times mating cycles / Working Temperature – 20C ~+ 65C. Make: Systemax, AMP, D-Link, R&M |
| 2457 | Supply, Installation, Testing and Commissioning of 1G Base-LR Single-Mode, 10KM, SFP+ (1310 nm).OEM Must have Local Office in Punjab/Chandigarh for Quick Support. All Switches and Networkiing Components from Same OEM.OEM should be present in Gartner Quadrant from last 5 years. Make: Cisco, Extreme, D-Link, Juniper |
| 2458 | Supply, Installation, Testing and Commissioning of 3 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 96v, Efficiency : Above 90%. With For 60 minutes SMF battery backup , rack/interlink cables. Make: Eaton, APC, Emerson |
| 2459 | Supply, erection, testing & commissioning of 1KVA onlinesine wave UPS/ Power plant with in built SMF batteries having 30 minutes backup time complete in all respects as approved and desired by the Engineer-in-charge at site. Make: APC, Numeric, Uniline, Eaton, Aqua Power. |
| 2460 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 2461 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 2462 | PVC CHANNEL (uPVC TRUNKING):Supply and erection ofPVC Channel (uPVC Trunking) with cover of various sizes (On Surface) on wall, Flat angle, internal & external angle, Flat Tee, End cap and mounting boxes including the cost of joint cover, fixing and other petty material etc.:- |
| 2463 | PVC Channel (uPVC Trunking) 50mm x 50mm |
| 2464 | End Cap50mm x 50mm |
| 2465 | PROVIDING SUBSTATION WORKS: |
| 2466 | HT CABLES & HT TERMINATION KIT: |
| 2467 | XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND):Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:- |
| 2468 | HT Cable Overall size 120sq.mm (3Core) |
| 2469 | XLPE INSULATED HT ARMOURED CABLES (LOOSE):Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:- |
| 2470 | HT Cable Overall size 120sq.mm (3Core) |
| 2471 | S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:- |
| 2472 | Heat Shrinkable End Termination for cable size 120-185 sq. mm, 3Core (Indoor Type) |
| 2473 | Heat Shrinkable End Termination for cable size 120-185 sq. mm, 3Core (Outdoor Type) |
| 2474 | 11KV HT SINGLE VACUUM CIRCUIT BREAKER SWITCHBOARD PANEL FOR INCOMING & OUTGOING: |
| 2475 | Supply, Erection, Testing and Commisioning of 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) switch board unit 630 Amp. which includes 630 Amp. Vacuum Circuit Breaker for Incoming/ Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of 25kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuitdead operation at rated short circuit current: 100 opeartion |
| 2476 | VCB parameters are as below: (a). Rated Voltage: 12kV(b). Rated short circuit breaking current withstand : Min. 25kA for 3sec.(c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak(d). Rated insulation voltage( Power frequency withstand) : Min. 28kV(e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO(f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz)(g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) (h). Earthing Switch : Mechanically interlocked device to prevent personnel from getting electric shock during breaker maintenance. VCB incorporating mechanical as well as electrical ON/OFF indiaction \"OFF\" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door. |
| 2477 | Incomer shall consist of:(a). Cast Resin CT\"s 11kV : 200-100/5+5A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA(b). Cast Resin PT\"s 11kV : PT Ratio 11kV/v3 / 110V/v3 / 110V/v3, Class 1, Class 0.5 Burden 50VA(c). Protections : Numerical instantaneous IDMTL mimic dispaly relay (230V, AC, 50Hz) : U/V, O/V, E/F, O/C, S/C & TCS with RS 485 Modbus protocol for communication & drawout type(d). Master Trip/ Anti pumping relay(e). Digital Voltmeter : Range 0-12kV with necessary voltmeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal.(f). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal.(g). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard(h). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operationsAll the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments. |
| 2478 | Outgoing shall consist of:(a). Cast Resin CT\"s 11kV : 200-100/5+5A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Protections : Numerical instantaneous IDMTL mimic dispaly relay : E/F, O/C, S/C & TCS with RS485 Modbus protocol for communication & drawout type for line feeder protection(c). Master Trip/ Anti pumping relay(d). Transformer Protection : 3 elements auxiliary relay (230V, AC, 50Hz) for transformer fault, Alarm for Buchholz, winding temperature & oil temperature (e). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 110V AC 96x96 sq.mm dial with shroded terminal(f). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard(g). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operationsAll the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments:- |
| 2479 | 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Switch board unit 630 Amp. which includes 1 No. 630 /800Amp. Vacuum Circuit Breaker for Incoming/ Out going feeder with in built power pack. Make: Schneider Electric, ABB, L&T, Siemens, Crompton Greaves |
| 2480 | Supply, Erection, Testing and Commisioning of 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) switch board unit 630 Amp. which includes 630 Amp. Vacuum Circuit Breaker for Incoming/ Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of 25kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuitdead operation at rated short circuit current: 100 opeartion |
| 2481 | VCB parameters are as below: (a). Rated Voltage: 12kV(b). Rated short circuit breaking current withstand : Min. 25kA for 3sec.(c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak(d). Rated insulation voltage( Power frequency withstand) : Min. 28kV(e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO(f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz)(g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) (h). Earthing Switch : Mechanically interlocked device to prevent personnel from getting electric shock during breaker maintenance. VCB incorporating mechanical as well as electrical ON/OFF indiaction \"OFF\" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door. |
| 2482 | Incomer shall consist of:(a). Cast Resin CT\"s 11kV : 200-100/5+5A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA(b). Cast Resin PT\"s 11kV : PT Ratio 11kV/v3 / 110V/v3 / 110V/v3, Class 1, Class 0.5 Burden 50VA(c). Protections : Numerical instantaneous IDMTL mimic dispaly relay (230V, AC, 50Hz) : U/V, O/V, E/F, O/C, S/C & TCS with RS 485 Modbus protocol for communication & drawout type(d). Master Trip/ Anti pumping relay(e). Digital Voltmeter : Range 0-12kV with necessary voltmeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal.(f). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal.(g). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard(h). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operationsAll the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments. |
| 2483 | Outgoing shall consist of:(a). Cast Resin CT\"s 11kV : 200-100/5+5A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Protections : Numerical instantaneous IDMTL mimic dispaly relay : E/F, O/C, S/C & TCS with RS485 Modbus protocol for communication & drawout type for line feeder protection(c). Master Trip/ Anti pumping relay(d). Transformer Protection : 3 elements auxiliary relay (230V, AC, 50Hz) for transformer fault, Alarm for Buchholz, winding temperature & oil temperature (e). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 110V AC 96x96 sq.mm dial with shroded terminal(f). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard(g). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operationsAll the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments:- |
| 2484 | 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Switch board unit 630 Amp. which includes 1 No. 630 /800Amp. Vacuum Circuit Breaker as Incomer, 2Nos. Vacuum Circuit Breaker as Out going feeder with in built power packs interconnected with Electrolytic Copper bus bars of suitable ratingMake: Schneider Electric, ABB, L&T, Siemns, Crompton Greaves |
| 2485 | TRANSFORMERS 800KVA: |
| 2486 | Supply, installation, testing and commissioning of 11KV/433V, 800KVA, Indoor/Outdoor type floor mounted Distribution Transformer, Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor cnforming to IS:1180 (2014) Level-3 & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV(c). Off Circuit Tap changer: +5% to -10% off circuit tapping in steps of 2.5%.(d). Vector group : Dyn11 (e). Ambient temperature: 50°C(f). Oil/ Winding temperature rise: As per IS:1180(g). Magnetic Core:Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side(j). Insulation Level: ? H.V. Power Frequency (KV rms) : 28 kV ? H.V. Impulse withstand voltage (KV peak): 75 kVpThe Tranformers shall fitted withaccesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay& Fixed/ Detachable Radiator. Note: Manufacturer testing labotatory to be NABL certified with in house core cutting facility for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer designed for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:- Make: Schneider, Kirloskar, Crompton Greaves, Voltamp |
| 2487 | APFC PANEL 300KVAR: |
| 2488 | Design, supply, installation, testing and commissioning of APFC Panel of 300 KVAR capacity with 7% detuned reactor suitable for operation on 415 ± 5% Volt, 3 Phase, 50 Hz, Ac supply, having MPP type resin bounded static capacitors (without oil) of suitable rating complete with MCCB Four Pole 630amp., 415volts, =36kA Microprocessor Based Adjustable Thermal and Magnetic Setting (Ics = 100%) capacity panel, 12step microprocessor based power factor controller relay capable to select the rating from1No.x 5KVAR, 2No.x 10KVAR, 2No.x 15KVAR, 1No. x 20KVAR, 5No. x 25KVAR, 2No. x 50KVAR capcitor bank, current limiting contactors for each capacitors protected with suitable rating MCCBs of minimum 25 KA breaking capacity having thermal magnetic release for over load & short circuit protection, cooling fans for panel and digital multifunction meter, Class-1.0 with RS485 communication port indicating lights, earthing the panel etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part of 300 KVAR capacity, automatically as and when required. Capacity of static capacitor should be accommodated from the overall rating of the panel and should be designed to switch in independently. The panel should be manufactured with1.6 mm thick CRCA sheet duly powder coated etc complete as per PWD specification complete as persatisfaction of the Engineer in charge at site.Panel builders Make: Kalyani Switchgear, ETE Electrogears, Power Associates, Unix, CMKL |
| 2489 | MAIN LT PANEL- NORMAL SUPPLY |
| 2490 | Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP44).Fabrication: Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS:8623. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The base channel will be made out of 75mm x 40mm x 5mm rolled channel. \"The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. |
| 2491 | Painting:The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work. Busbars: The panel shall be provided with TPN copper busbar of suitable size according to the size of MCCB\"s.All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard). The Concerned contactor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of ACB/MCCB\"s to be installed in the cubical panel Enclosure (including the cost of MCCB\"s+E.R.H.) as per following. |
| 2492 | Transformer Incomer: Air circuit-breaker of suitable ampere rating at 415V, 50Hz, 4 Pole Electrical draw-out type with inbuilt microprocessor based trip sytem with thermal memory, zone selective interlocking, pre trip alarm, individual fault indicating LED, O/C, S/C, Instantaneous & E/F internal protection, Impulse withstand voltage 12kV, rated insulation voltage 1000V, rated operational voltage 690V, fully rated neutral, protection against overload & shortcircuit with setting at 50%-100%-OFF,suitability for isolation as per IEC 60947-2. The ACB should be capable for recording 10 fault history, LCD Display of current & voltage, Icu = Ics = Icw (1 Sec.) = 50kA with no derating upto 50 degree celcius on the existing industrial panel (With terminal adapter on load and line side of breaker), including bonding to the existing earth and making necessary connections with suitable size of thimbles as required by the Engineer-in-Charge at site and as per PWD General Specifications¦ 1250 Amp.415volts 50KA,, 4P EDO ACB = 1No. (From Transformer-1, 800KVA)Under Voltage Release 220VAC for ACB Interlocking¦ 1250 Amp.415volts 50KA,, 4P EDO ACB = 1No. (Bus Coupler)Under Voltage Release 220VAC for ACB Interlocking¦1250 Amp.415volts 50KA,, 4P EDO ACB = 1No. (From Transformer-2, 800KVA) Under Voltage Release 220VAC for ACB InterlockingINTERLOCKING: Both incomer and Buscoupler electricaly interlocked at a time two breaker can be operate. (Electrically & Mechanical Interlocked) |
| 2493 | Outgoings from Transformer-1, 800KVA.:¦ 630amp. 415 volts breaking capacity =36kA, FP microprocessor based adjustable thermal and magnetic protection MCCB unit = 2Nos.¦ 400amp. 415 volts breaking capacity =36kA, FP microprocessor based adjustable thermal and magnetic protection MCCB unit = 1No.¦ 250amp. 415 volts breaking capacity =36kA, FP microprocessor based adjustable thermal and magnetic protection MCCB unit= 2Nos. ¦ 160amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 1No. ¦ 100amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 2Nos. ¦ 40-80amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 2Nos. Outgoings from Transformer-1, 800KVA :¦ 800amp. 415 volts breaking capacity =36kA, FP microprocessor based adjustable thermal and magnetic protection MCCB unit = 2Nos.¦ 400amp. 415 volts breaking capacity =36kA, FP microprocessor based adjustable thermal and magnetic protection MCCB unit = 2No.¦ 250amp. 415 volts breaking capacity =36kA, FP microprocessor based adjustable thermal and magnetic protection MCCB unit = 2Nos. ¦ 160amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 1No. ¦ 100amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 2Nos. ¦ 40-80amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 2Nos. ¦All Incomers & Out going With Extendable Rotary Handle with adjustable depth complete as per schematic diagram attached & Satisfaction of the Engineer in charge at site.Enclosure:Panel Size: As per NormsPanel builders Make: Kalyani Switchgear, ETE Electrogears, Power Associates, Unix, CMKL |
| 2494 | AMF PANEL (LOAD SHARING PANEL): |
| 2495 | Designing, Supply, Erection, Testing & commissioning of indoor Type AMF PANEL (LOAD SHARING PANEL) suitable for 2Nos. DG Set capacity 400 KVA enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP44).Fabrication: Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS:8623. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The base channel will be made out of 75mm x 40mm x 5mm rolled channel. \"The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. |
| 2496 | Painting:The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work. Busbars: The panel shall be provided with TPN copper busbar of suitable size according to the size of MCCB\"s.All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard). The Concerned contactor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of ACB/MCCB\"s to be installed in the cubical panel Enclosure (including the cost of MCCB\"s+E.R.H.) as per following. |
| 2497 | AMF Systemfor Load Sharing:AMF Relay, Start - Stop Push Buttons (Set), Auxiliary Relay - 220VAC - 10A, Auxiliary Relay - 12/24VDC - 10A, Control Selector Switch, Battery Charger 220V AC/12/24VDC-10A with Auto-Cut Booster,Terminal Blocks - Power and Control, Panel Mounted Hooter, Emergency Stop Push Buttons 220V AC, Hooter for Alarm - 24V DC, Hooter Accept Push Button, Voltage Monitoring RelayPLC System - For Interlocking & Load Shearing + Load Management: |
| 2498 | AMF PANEL (LOAD SHARING PANEL) suitable for 2Nos. DG Set capacity 400 KVA EACH:Air circuit-breaker of suitable ampere rating at 415V, 50Hz, 4 Pole Electrical draw-out type with inbuilt microprocessor based trip sytem with thermal memory, zone selective interlocking, pre trip alarm, individual fault indicating LED, O/C, S/C, Instantaneous & E/F internal protection, Impulse withstand voltage 12kV, rated insulation voltage 1000V, rated operational voltage 690V, fully rated neutral, protection against overload & shortcircuit with setting at 50%-100%-OFF,suitability for isolation as per IEC 60947-2. The ACB should be capable for recording 10 fault history, LCD Display of current & voltage, Icu = Ics = Icw (1 Sec.) = 50kA with no derating upto 50 degree celcius on the existing industrial panel (With terminal adapter on load and line side of breaker), including bonding to the existing earth and making necessary connections with suitable size of thimbles as required by the Engineer-in-Charge at site and as per PWD General SpecificationsIncomer Feeder From Transformer-1: ¦ 800 Amp.415volts 50KA,, 4P EDO ACB = 1No. (From Transformer-1, 800KVA) = 1No. Incomer Feeder: 400KVA¦ 800 Amp.415volts 50KA,, 4P EDO ACB = 1No. (From DG SET 800KVA) = 1No. Bus Coupler: ¦ 800 Amp.415volts 50KA,, 4P EDO ACB = 1No. Incomer Feeder From Transformer-2: ¦ 800 Amp.415volts 50KA,, 4P EDO ACB = 1No. (From Transformer-1, 800KVA) = 1No. Incomer Feeder: 400KVA ¦ 800 Amp.415volts 50KA,, 4P EDO ACB = 1No. (From DG SET 800KVA) = 1No. Outgoings Feeders: ¦ 400amp. 415 volts breaking capacity =36kA, FP microprocessor based adjustable thermal and magnetic protection MCCB unit = 5Nos.¦ 250amp. 415 volts breaking capacity =36kA, FP microprocessor based adjustable thermal and magnetic protection MCCB unit = 4Nos.¦ 160amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 1No. ¦ 125amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 1No. ¦ 100amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 3Nos. ¦ 40-80amp. 415 volts breaking capacity =25kA four pole fixed magnetic & adjustable thermalsetting MCCB unit = 2Nos. ¦All Incomers & Out going With Extendable Rotary Handle with adjustable depth complete as per schematic diagram attached & Satisfaction of the Engineer in charge at site.Enclosure:Panel Size: As per NormsPanel builders Make: Kalyani Switchgear, ETE Electrogears, Power Associates, Unix, CMKL |
| 2499 | SANDWICH TYPE ALUMINIUM BUS BAR TRUNKING: |
| 2500 | Supply, Installing testing and commissioning of 1250A, 3P + 100% Neutral, 50KA For 1 Sec, Sandwich Bus trunking Straight Feeder Length, Aluminium Conductor, IP 55 with GI Enclosure in 1.5mm Thick. continuous earthing with 2 Nos integral earth conductor and Suspension Hanging system etc along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Legrand, Schneider, L&T, C&S |
| 2501 | Supply, Installing testing and commissioning of 1600A, 3P + 100% Neutral, 50KA For 1 Sec, Sandwich Bus trunking Straight Feeder Length, Aluminium Conductor, IP 55 with GI Enclosure in 1.5mm Thick. continuous earthing with 2 Nos integral earth conductor and Suspension Hanging system etc along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Legrand, Schneider, L&T, C&S |
| 2502 | Supply, Installing, testing & commissioning of Elbow vertical/Horizontal /off set Bend 1250Amp / 3P+1N+E (Only fabrication charges) etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Legrand, Schneider, L&T, C&S |
| 2503 | Supply, Installing, testing & commissioning of Elbow vertical/Horizontal /off set Bend 1600Amp / 3P+1N+E (Only fabrication charges) etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Legrand, Schneider, L&T, C&S |
| 2504 | Supply, InstallingFlange End Unit 1250 Amp (Fabrication Charges only) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Legrand, Schneider, L&T, C&S |
| 2505 | Supply, InstallingFlange End Unit 1600 Amp (Fabrication Charges only) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Legrand, Schneider, L&T, C&S |
| 2506 | Supply, installation, Copper Flexible 1250Amp(1 Set of 4Nos. Copper Flexible) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Legrand, Schneider, L&T, C&S |
| 2507 | Supply, installation, Copper Flexible 1600Amp(1 Set of 4Nos. Copper Flexible) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Legrand, Schneider, L&T, C&S |
| 2508 | Supply, installation, ofAdopter Box/tap off box for Transformer side and panel side1250 Amp. etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Legrand, Schneider, L&T, C&S |
| 2509 | Supply, installation, ofAdopter Box/tap off box for Transformer side and panel side 1600 Amp. etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Legrand, Schneider, L&T, C&S |
| 2510 | SUB STATION SAFETY EQUIPMENTS: |
| 2511 | Supply of Rubber hand gloves suitable for 11KV. |
| 2512 | Supply & fixing of shock treatment chart both in Hindi & English for treating person suffering due to electricshock mounted on wall hooks. |
| 2513 | Providing and fixing H.T. danger notice plate of 250 mm x 200mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. |
| 2514 | Providing and fixing M.V. danger notice plate of 200 mm x 150mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. |
| 2515 | Providing and fixing of Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878-1976 and cylinder fully charged of 4.5 Kg capacity. |
| 2516 | Supply and fixing of foam fire extinguishers, Portable type 9 Litre capacity hanged on wall with bracket component as required. |
| 2517 | Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red - oxide paint and written with white paint \"Fire\" and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc. |
| 2518 | Supply of First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 -1963 |
| 2519 | Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of 2.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment), suitable for all voltages not exceeding 3.3 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments. |
| 2520 | Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of minimum 3.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment),, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments. |
| 2521 | Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:- (From VCB to Transformer for safety controls) |
| 2522 | Overall size 1.5sq.mm (10 Core) |
| 2523 | XLPEINSULATED ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 2524 | Overall size 35sq.mm (3½ Core) Un-armoured (Loose) |
| 2525 | Overall size 70sq.mm (3½ Core) Un-armoured (Loose) |
| 2526 | Overall size 95sq.mm (3½ Core) Un-armoured (Loose) |
| 2527 | Overall size 120sq.mm (3½ Core) Un-armoured (Loose) |
| 2528 | Overall size 185sq.mm (3½ Core) Un-armoured (Loose) |
| 2529 | Overall size 240sq.mm (3½ Core) Un-armoured (Loose) |
| 2530 | Overall size 300sq.mm (3½ Core) Un-armoured (Loose) |
| 2531 | Overall size 400sq.mm (3½ Core) Un-armoured (Loose) |
| 2532 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 2533 | Aluminium thimble cable Core size 10 -16sq.mm |
| 2534 | Aluminium thimble cable Core size 25 -35sq.mm |
| 2535 | Aluminium thimble cable Core size 50sq.mm |
| 2536 | Aluminium thimble cable Core size 70sq.mm |
| 2537 | Aluminium thimble cable Core size 95sq.mm |
| 2538 | Aluminium thimble cable Core size 120sq.mm |
| 2539 | Aluminium thimble cable Core size 150sq.mm |
| 2540 | Aluminium thimble cable Core size 185sq.mm |
| 2541 | Aluminium thimble cable Core size 240sq.mm |
| 2542 | Aluminium thimble cable Core size 300sq.mm |
| 2543 | Aluminium thimble cable Core size 400sq.mm |
| 2544 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 2545 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 25-35sq.mm |
| 2546 | Brass Gland for Aluminium cable 3/3½/4 Core size 70sq.mm |
| 2547 | Brass Gland for Aluminium cable 3/3½/4 Core size 95-120sq.mm |
| 2548 | Brass Gland for Aluminium cable 3/3½/4 Core size 185sq.mm |
| 2549 | Brass Gland for Aluminium cable 3/3½/4 Core size 240sq.mm |
| 2550 | Brass Gland for Aluminium cable 3/3½/4 Core size 300sq.mm |
| 2551 | Brass Gland for Aluminium cable 3/3½/4 Core size 400sq.mm |
| 2552 | CABLE TRAY: |
| 2553 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 2554 | Cable Tray Size 150mm x 50mm x 50mm (2mm thick) |
| 2555 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 2556 | Cable Tray Size 450mm x 50mm x 50mm (2mm thick) |
| 2557 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 2558 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 2559 | Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
| 2560 | Double walled corrugated (DWC) HDPE pipe90/76mm (outer/ inner dia.) |
| 2561 | Double walled corrugated (DWC) HDPE pipe120/103.5mm (outer/ inner dia.) |
| 2562 | Double walled corrugated (DWC) HDPE pipe160/136mm (outer/ inner dia.) |
| 2563 | EARTHING: |
| 2564 | COPPER EARTHING (Upto 14 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 2565 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 2566 | COPPER EARTHING (Upto 23 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 19.50 metre (63.96 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc.,up to 23metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 18metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 2567 | Earthing with 40mm x 5mm Copper Tape (upto 23Metre in Length) |
| 2568 | Additional Length 20mm x 3mm thick Copper Tape . |
| 2569 | Additional Length 40mm x 5mm thick Copper Tape |
| 2570 | PROVIDING SILENT DG SET & ACCESSORIES: |
| 2571 | Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 625 KVA /500KW .Itshould be air cooled/water coolednaturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard).ENGINE: The Diesel engine developing suitable BHP for giving a power rating as per ISO 8528- Part-1 ( With CPCB-II Norms) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements.Make :- Cummins, Koel Greeen (Kirloskar), Mahindra (perkins)ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. |
| 2572 | ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.Make :- Crompton Greaves, Stamford , Koel Green (Kirloskar) Lesoy Somes.ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteriesaccommodated in thebattery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 yearwarranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable sizeexistingplinth of RCC as per specifacationDG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge. MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:- |
| 2573 | EXHAUST PIPE: |
| 2574 | Supply and fixing of following sizes of MS \" B \" Class piping with bends etc. for Exhaust of DG Sets including providing suitable self supporting arrangement at suitable intervals, painting etc. and supplying & fixing 150 mm thick Rock wool matrix (3x50 mm. thick) insulation of density 150 Kg per cubic metre on all sides of Exhaust pipe and silencer with chicken mesh wrapping and 22 SWG aluminium sheet cladding, suitable for outdoor installation complete as required including guide support, expansion joint, SS bellows as required and as per specification. |
| 2575 | 250 mm dia (NB) |
| 2576 | PROVIDING EXTERNAL LIGHTING: |
| 2577 | POLES: |
| 2578 | GALVANIZED STEEL OCTAGONAL POLES FOR WIND VELOCITY OF 169 Km/ HOUR:Supply and erection ofGalvanized Steel Octagonal Pole (Sheet thickness 3mm) designed to withstand wind speed 169km/ hour of suitable length (Raw material confiming to IS-5986 (FE-510), BSEN-10025S-355J or ASTM-572A (GR-50)) and thickness of galvanization (70mm thick) conformingto IS:2629/ IS:2633/ IS:4759, BSEN-ISO-1461-1991 OR ASTM-A123/A123M-02. The pole shall be in single piece hot dip galvanized and shall be tapered towards the top. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangementfor housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The octagonal pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20with steel of given sizeas per design of original pole manufacturer to fixed up to a required planting depth below ground level as required:- |
| 2579 | Galvanized Octagonal Pole Overall Length 7 metre (Sheet thickness 3mm), Top dia.(A/F) 70mm and bottom dia. (A/F) 130mm, Foundation size below G/L 550mm x 550mm x 1400mm, 4Nos. Foundation Bolts size 20mm dia., Length=700mm with Base Plate Dimensions 240mm x 240mm x 16mm Thick |
| 2580 | Galvanized Octagonal Pole Overall Length 4 metre, Top dia.(A/F) 70mm & Bottom dia. (A/F) 130mm, Foundation size below G/L 550mm x 550mm x 900mm, 4Nos. Foundation Bolts size 16mm dia., Length=450mm with Base Plate Dimensions 200mm x 200mm x 12mm Thick |
| 2581 | GALVANIZED OCTAGONAL POLE BRACKETS:Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos. ½\" x 1½\" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thicktriangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:- |
| 2582 | Single arm bracket 0.5 metre long for galvanized octagonal pole |
| 2583 | DECORATIVE POLE WITH POST TOP FIXTURE: |
| 2584 | Supply, Erection, testing & commissioning of 4 Metre Decorative Steel Pole & Fixtures have following specification:Pole: 4 Metre Decorative Steel Pole are made of galvanized grooved steel tubes having bottom part of the pole 1000mm x 140mm x 4.8mm and upper part of the pole 3000mm x 90mm x 4mm made out of B class mild steel galvanized grooved tubes. The bottom and middle part of the poles are ?tted with cast aluminium embellishment and are ?tted and sealed by grub screws as shown in the drawing. The poles has a service window at the bottom containing 25Amp. connector terminal and MCB of the desired rating. The bottom cast aluminium embellishment cover the strengthening ribs and welding joints. The poles are primer coated and painted with polyurethane paint of the desired colour.Fixture : Urban Ornamental 40 Watt LED Post Top Luminaire made of aluminium housing duly powder coated/PU painted with PC/PMMA Clear/Frosted di?user with sturdy Twin arm. MCPCB having high Lumen LED’s are mounted on aluminium heat sinks. Foundation:Foundation size below G/L 550mm x 550mm x 900mm, 4Nos. Foundation Bolts size & rigid Base Plate suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20with steel of given sizeas per design of original pole manufacturer to fixed up to a required planting depth below ground level as required as per drawing attached.Make:Twinkle Lite (Pole Cat. No.SCRLT-E10-409040, Fixture Cat. No. Twinkle Lite-511 (PT-40)) Twinkle Luxmax (Pole Cat. No.SP-140-400, Pole Base Cat. No. Cast Aluminium Pole Base-140,Fixture Cat. No. Luxmax-PT-232-P-40W Post Top), Homedec, K-Lite (DESIGN AS PER DRAWING ATTACHED) |
| 2585 | NOTE: (COMMON FOR ITEM NO.1 & 3)Size & Reinforcement details of foundation mention in BOQ item is minimum requirement. Contractor to check & confirm design of foundation prior to quoting and shall account for actual requirement. Foundation of Pole shall be cast as per contractor\"s shop drawing duly design verified from structural / civil agency. |
| 2586 | LIGHT FIXTURES: |
| 2587 | Supply, Installation Testing and Commissioning of 10-11 Watt LED bollard (Including driver) of height 800-1000mm made of MS housing black matt powder coated, special translucent PMMA diffuser with IP-65 protection complete with electronic control gear, fixing screws and all accessories as required at site. Make: Crompton Cat. No. LBLSN-10-CDL, Wipro Cat. No.LB14-131-XXX-65-08, Havell\"s Cat. NO. MOUNTBL10WLED857PSYMTOPMMAM (1.0 M) |
| 2588 | Supply, installation, testing and commissioning of 1Watt asymmetrical inground driveover luminaire with driver with fixture body made of diecast aluminium integrated with toughened glass diffuser, beam angle 35º /45º shidding ring of stainless steel, ofprewired for operation on 240V, 50 Hz with IP-65 Protection complete with all accessories as required complete as required and all accessories as required. K-:Lite Cat. No.4107 |
| 2589 | Supply, installation, testing and commissioning of 7Watt symmetrical inground driveover luminaire with driver with fixture body made of diecast aluminium integrated with toughened glass diffuser, beam angle 10º /24º shidding ring of stainless steel, ofprewired for operation on 240V, 50 Hz with IP-65 Protection complete with all accessories as required complete as required and all accessories as required. K-:Lite Cat. No.4147 |
| 2590 | Supply and erection of LED street light 60 watt with pressure die cast aluminium housing with control gear (IP 66 protection), toughened glass fitting, surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt complete in all respects as approved and desired by the Engineer in-charge at site. The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Make: Havell\"s Cat. No. NDURAPEARLNEOSL60WLED757PASYTOPC, Crompton Cat. No. LST-60-CDL-M, Bajaj Cat. No. ENXT P 60L WW CR PC SD, Wipro Cat. No. LR13-671-XXX-57-XX |
| 2591 | Supply, Installation, Testing and Commissioning of 9Watt LED circular wall/ceiling mounting light fixture with housing made of ABS plastic with high efficency Translucence diffuser IP-54 protection rating, complete with driver & all accessories as required of Wipro Cat. No. MOON LED (LW01). |
| 2592 | Supply, Installation, Testing and Commissioning of 8-9Watt LED Integral bush light made of diecast aluminium, powder coated housing, high efficiency plastic reflector, 10/24/36/55 deg. Beam angle, IP-67 protection with inbuilt electronic driver complete with earth spike & all other accessories as requried of Wipro Cat. No.LF05-600-036-27-XX, Havell\"s Cat. No. LYCUSSPS9WLED730PSYMBOTG |
| 2593 | Supply, Installation, Testing and Commissioning of 6W LED Under water luminaires made out of marine grade 316 stainless steel, IP-68 protection, 24V DC operated voltage complete with wall recess box, screws, wire entry cutout, 5 meter Cable & all fixing accessories complete as required. MAKE: K-LITE Cat. No.4131 |
| 2594 | Supply, Installation, Testing and Commissioning of 12W LED Under water luminaires made out of marine grade 316 stainless steel, IP-68 protection, 24V DC operated voltage complete with wall recess box, screws, wire entry cutout, 5 meter Cable & all fixing accessories complete as required. MAKE: K-LITE Cat. No.4127 |
| 2595 | Supply, Installation, Testing and Commissioning of 18W LED Under water luminaires made out of marine grade 316 stainless steel, IP-68 protection, 24V DC operated voltage complete with wall recess box, screws, wire entry cutout, 5 meter Cable & all fixing accessories complete as required. MAKE: K-LITE Cat. No.4129 |
| 2596 | Supply, Installation, Testing and Commissioning of 60W, 24V DC 2.5 Amp., IP-67 Power supply suitable for under water luminaires complete in all respect with satisfaction of the Engineer-in-charge.MAKE: K-LITE Cat. No.8197 |
| 2597 | Supply and erection of LED Flood Light 80watt (including LED driver), IP-66 Pressure Die cast aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: WIPRO LF19-931-060-57-XX, Crompton LFL-80-CDL/60-HPM, BAJAJ BJFL 80W LED I |
| 2598 | Supply and erection of LED Flood Light 150watt (including LED driver), IP-66 Pressure Die cast aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: WIPRO LF19-931-060-57-XX, Crompton CFS-501-150-57-60D-SL-GL-NGG , BAJAJ BJFL 150W LED I |
| 2599 | Supply and erection of LED Flood Light 250watt (including LED driver), IP-66 Pressure Die cast aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: WIPRO LF30-342-060-57-XX, Crompton CFS-506-250-57-60D-HL2-GL-NBR, BAJAJ BJFL 250W LED WH MB |
| 2600 | Supply, installation, testing and commissioning of Step light recess mounted 4-6W LED fixture (including driver) and all accessories as required. Make: Crompton Cat. No. LSL-6-CDL, Bajaj Cat. No.BLSGV 4W LED WH, Havell\"s Cat. No. RADIANTNEOFT07WLED830SASYMBOPC |
| 2601 | XLPE INSULATED ARMOURED CABLES (ON SURFACE): |
| 2602 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 2603 | Overall size 16sq.mm (4Core) Un-armoured (On-Surface) |
| 2604 | Overall size 6sq.mm (3Core) Armoured (On-Surface) |
| 2605 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 2606 | Aluminium thimble cable Core size 4 - 6sq.mm |
| 2607 | Aluminium thimble cable Core size 10 -16sq.mm |
| 2608 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 2609 | Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm |
| 2610 | Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm |
| 2611 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 2612 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 2613 | Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed |
| 2614 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 2615 | Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed |
| 2616 | CABLE TRAY: |
| 2617 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 2618 | Cable Tray Size 150mm x 50mm x 50mm (2mm thick) |
| 2619 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 2620 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 2621 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 2622 | Double walled corrugated (DWC) HDPE pipe90/76mm (outer/ inner dia.) |
| 2623 | Double walled corrugated (DWC) HDPE pipe160/136mm (outer/ inner dia.) |
| 2624 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: |
| 2625 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 2626 | Overall size 1sq.mm (Un-sheathed) |
| 2627 | Overall size 1.5sq.mm (Un-sheathed) |
| 2628 | Overall size 2.5sq.mm (Un-sheathed) |
| 2629 | Overall size 4sq.mm (Un-sheathed) |
| 2630 | Overall size 6sq.mm (Un-sheathed) |
| 2631 | Overall size 10sq.mm (Un-sheathed) |
| 2632 | MDB & DB\"s EXTERNAL LIGHTING: |
| 2633 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s: Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB\"s as incomer and outgoings SP/TPminiature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 2634 | MDB-EXTERNAL LIGHTING: |
| 2635 | TP&NDouble Door Vertical DB\"s 8 way each (With provision of FP MCCB upto 125amp) |
| 2636 | DB-1 TYPICAL FOR DB-2, DB-3, DB-4, DB-5, DB-6 & DB-7 |
| 2637 | TP&NDouble Door Vertical DB\"s 4 way each (With provision of FP MCCB 125amp.) |
| 2638 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 2639 | MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2640 | MCCB Four Pole 125amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2641 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 2642 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 2643 | MCB Triple Pole 40amp. (10kA, Curve-C) |
| 2644 | EARTHING SYSTEM: |
| 2645 | G.I. EARTHING:Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 2646 | Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length) |
| 2647 | COPPER EARTHING (Upto 8 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc.,up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 2648 | Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) |
| 2649 | COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 2650 | Additional Length 20mm x 3mm thick Copper Tape |
| 2651 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc. |
| 2652 | Additional length G.I. rope 7/14 S.W.G. (7/2.18mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 2653 | PROVIDING ADVANCE LIGHTING PROTECTION SYSTEM: |
| 2654 | As per Drawing Attached: |
| 2655 | Supply, erection, testing & commisioning ofEarly Streamer Emission (ESE)type Lightning Protection Complete with Lightning Air Terminal. The System should be corrosion resistant stainless steel chrome bodycapable of working in hazardous atmosphere andprotecting against direct Lightning point as well conducting /diverting it to earth completely after tracing the Lightning in advance. As per NF C 17-102:2011 the air terminal should be tested for Lightning impulse current (10/350 micro sec) =100 KAand for local certification the air terminal should be tested forswitching impulse currentof 40 KA (8/20 micro sec) as per CPRIwith 5 positive and 5 negative impulse. The ESETerminals shall offer a protection radius of 79mtr., Level-1 High Protection and preferably to be mounted on roof top and center of the building / blocks with the highly insulated polyplastic adaptor with the Mast. (Its working principle evolves from local electrostatic field that develops naturally around the system as a thunderstorm begins to gather. In the event of descending lightning, an inbuilt triggering device generates high tension pulses at the conductor tip, causing a ‘corona effect’.) Protection radius of 79Mtr at level 1 & 107 Mtr at level 4 Make: JMV, LPI, Escoltrix |
| 2656 | Supply and fixing of GI Mast 5 mtr. height along with suitable base plate for mounting the terminal along with highly insulatedadopter to mount ESE Air Terminal with the Mast.The Adapter shall have suitable Metal connector /Connecting point in such a way the top portion shall be electrically connected to the central tip of the ESE terminal and bottom portion connected to the down conducto, stray wires along with support shall be securely fixed with base plate and gauge wires where ever required.Make: JMV, LPI, Escoltrix |
| 2657 | Supply and installation of Lightning Strike Counter (6 digit display) of non-resettable(electromechanical) type which allows the automatic counting of the strikes received by the lightning protection system. This information is used to enhance lightning protection security & increase the effectiveness of inspection & maintenance procedures. It should be in IP-65 enclosure with minimum sensitivity of 1KA and maximum capacity 100KA. No external power source is required. It should be installed always 2 mtrs. above the ground level.Make: JMV, LPI, Escoltrix |
| 2658 | Supply & erection of test Link of non-corroding, weather proof, water proof polycarbonate IP 65/55 enclosure including providing of 2 Nos. of insulated supports with suitable holes prefitted nuts & bolts to fix the down conductor & earth wire. The transparent cover fitted at approximately 500-1000mm from ground level shall be provided on each down conductor.Make: JMV, LPI, Escoltrix |
| 2659 | Supply, installation & testing of chemical earthing (Maintenance Free Earthing) system with UL approved copper bonded rod and exothermically welded copper busbar both tested by CPRI at 50kA Fault Current. A copper bonded steel rod shall have 3000 mm length and17.2 mm dia. with copper coating thickness of minimum 250 microns. Along with earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A copper clad steel solid ground wire of 8 mm dia. for interconnecting earth pits. Each earth pitshall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber. The grounding minerals should not be pollute the ground water. The grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr.Make: JMV, AI (Amiable Impex), Growth |
| 2660 | Cost of pole foundation with earth work in excavation in foundations trenches etc. 0.25 meter below ground level, Cement Concrete 1:4:8 with stone ballast, Reinforced cement concrete M-20,Cold twisted deformed (Ribbed/tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 complete in all respect as desired by engineer in charge. |
| 2661 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 2662 | Overall size 70sq.mm (Un-sheathed) (as down conductor to connect the air terminal and erthing) |
| 2663 | PROVIDING LIFTS 4NOS. 13 PASSENGER: |
| 2664 | ZONE-1 ENTRANCE PLAZA: |
| 2665 | 1No. Lift13 Passengers (3 Floors): For Lower Basement to Entrance Plaza (Ground floor) |
| 2666 | Supply, installation, testing and commissioning of 1 No. lift of 13 passengers machine room less.Type and Capacity :Approximately 884 Kg, 13 PassengersSpeed:1.0 Meter per secondType of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor.Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist wayTravel: Approximately 8.5 meter________Serving:_3 Floors _3 Stops_3 Openings_3 Levels (All on the same side)Hoist way Required: 2050mm (Wide) x 2500mm (Deep) Clear dimensionsHeadroom Height (HR): 5000 mm beyond finished floor level of last landing Pit Depth: 1600mm below the finish floor level of first landing Car Size Area: Minimum 2.06 square meter and Maximum 2.20 square meter Car Enclosure: Constructed out of stainless steelScratch proof Finish (Vandal Proof).Car Entrance: Center Opening Automatic Doors with vision panel (40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 900mm (wide) x 2000mm (high) Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdentOperation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating CurrentFlooring: Floor Skid - Resistant as per standardFan: Blower Fan in Car for ventilation with Auto cut offLighting: LED for Car LightingIndicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features. |
| 2667 | Other Features:1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons5. Door Open and Close buttons6. Emergency Intercom provided inside the elevator7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication9. Steel items, door frames sill angle\"s, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level\"s in english/regional language only and indication of door for entrance / exit is .either Open or Close19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.28. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight.29. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids.30. Elevator must compulsoy with the letterconstruction as desired in the disability set.Make: Otis, Schindler, Kone, Mitshubishi |
| 2668 | ZONE-3 COVERED COLLONADE: |
| 2669 | Supply, installation, testing and commissioning of 1 No. lift of 13 passengers machine room less.Type and Capacity :Approximately 884 Kg, 13 PassengersSpeed:1.0 Meter per secondType of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor.Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist wayTravel: Approximately 5.5 meter________Serving:_2 Floors _2 Stops_2 Openings_2 Levels (All on the same side)Hoist way Required: 2050mm (Wide) x 2500mm (Deep) Clear dimensionsHeadroom Height (HR): 5000 mm beyond finished floor level of last landing Pit Depth: 1600mm below the finish floor level of first landing Car Size Area: Minimum 2.06 square meter and Maximum 2.20 square meter Car Enclosure: Constructed out of stainless steelScratch proof Finish (Vandal Proof).Car Entrance: Center Opening Automatic Doors with vision panel (40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 900mm (wide) x 2000mm (high) Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdentOperation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating CurrentFlooring: Floor Skid - Resistant as per standardFan: Blower Fan in Car for ventilation with Auto cut offLighting: LED for Car LightingIndicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features. |
| 2670 | Other Features:1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons5. Door Open and Close buttons6. Emergency Intercom provided inside the elevator7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication9. Steel items, door frames sill angle\"s, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level\"s in english language only and indication of door for entrance / exit is .either Open or Close19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.28. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight.29. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids.30. Elevator must compulsoy with the letterconstruction as desired in the disability set.Make: Otis, Schindler, Kone, Mitshubishi |
| 2671 | ZONE-4 ICONIC TOWER: |
| 2672 | Supply, installation, testing and commissioning of 1 No. lift of 13 passengers machine room less.Type and Capacity :Approximately 884 Kg, 13 PassengersSpeed:1.0 Meter per second to 1.5 Mtr. per Second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor.Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist wayTravel: Approximately 44 meter________Serving:_12 Floors _12 Stops_12 Openings_12 Levels (All on the same side)Hoist way Required: 2050mm (Wide) x 2500mm (Deep) Clear dimensionsHeadroom Height (HR): 5000 mm beyond finished floor level of last landing Pit Depth: 1600mm below the finish floor level of first landing Car Size Area: Minimum 2.06 square meter and Maximum 2.20 square meter Car Enclosure: Constructed out of stainless steelScratch proof Finish (Vandal Proof).Car Entrance: Center Opening Automatic Doors with vision panel (40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 900mm (wide) x 2000mm (high) Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdentOperation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating CurrentFlooring: Floor Skid - Resistant as per standardFan: Blower Fan in Car for ventilation with Auto cut offLighting: LED for Car LightingIndicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features. |
| 2673 | Other Features:1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons5. Door Open and Close buttons6. Emergency Intercom provided inside the elevator7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication9. Steel items, door frames sill angle\"s, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level\"s in English / Regional language only and indication of door for entrance / exit is .either Open or Close19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.28. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight.29. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids.30. Elevator must compulsoy with the letterconstruction as desired in the disability set.Make: Otis, Schindler, Kone, Mitshubishi |
| 2674 | XLPEINSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 2675 | Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 2676 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 2677 | Overall size 16sq.mm (4Core) Un-armoured (On-Surface) |
| 2678 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 2679 | Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
| 2680 | COPPER EARTHING (8 SWG COPPER EARTHING): Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 2681 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 2682 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 2683 | MCCB\"s (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc. |
| 2684 | MCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 2685 | MS SHEET ENCLOSURE FOR MCCB\"s:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shallbe made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/topwith cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 2686 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 2687 | PROVIDING SOLAR POWER GENERATION SYSTEM: |
| 2688 | Supply, Installtion testing & commissioning of Grid Interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimum 19KWp including required quantities of SPV modules (Hight Power density Perc Bifacial Mococrytalline based) formed in to arrays, their mounting arrangement, Power conditioning units (i.e string Solar Inverter), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board throughcable tray Bi Directional Energy Meter required Earthing (i.e2 Nos GI strip earthing for GI Strcuture, 2 Nos GI Strip earthing for string inverter, AC & DC Distribution system) ESE stroke master (As per NFC 17 102 standard with suitable radius of protection) & 3 Nos chemical earthing with copper bonded rods along with high rise GPSP structure (Rated wind speed 170Kph) including mounting height up to 8 feet complete with transportaion, fabrication labour & civil work.Features: 1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 142862. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 605293. Structure 25 Years service life with AMC & certified under IS 2062 20114. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material)5. Annual Maintenance contract for the period of 5 YearsMake:1 Solar PV Module: EMBRO, VIKRAM, ADANI, WAREE2 Power Conditioning Unit: KEHUA, DELTA, LUMINOUS, SOLAX, TESA3 AC/DC Distribution Board: EMBRO, ABB, SCHNEIDER ELECTRIC, HAVELL\"S4 Fusion Mount structure: TATA GALVUME, POSMAC5 ESE Stroemaster with chemical Earthing: SABO, JMC, TP, HIGH GRIDThe work will got done from approved MNRE (Misitry of New and Renewable Energy) / PEDA (Punjab Energy Development Agency) contractorThe capacity of solar power plant may increase or decrease as availability of site it can also be totally removed by concerned Engineer-in-charge of work..The Rate are inclusive of all taxes including GST. |
| 2689 | Add extra cost of Cutlural Cess @ 1% |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy